Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Magnetic Sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Elastic-plastic conductor damage evaluation at over 0.4% strain using a high-stress REBCO coil

Abstract Recent reports on screening current stress simulations of high-field REBCO magnets frequently present peak stresses over 1 GPa. However, this result is probably an unrealistic artifact of purely elastic calculations, considering the macroscopic yield and fracture stresses of approximately 900 MPa and less than 1.1 GPa for Hastelloy substrate-coated conductors. Here, we evaluate elastic-plastic conductor damage at over 0.4% strain using a high-stress REBCO coil exposed to a high field to explore this elastic-plastic regime. The coil was located off-center in a low-temperature superconductor magnet so as to induce a significant screening current in the enhanced radial field. Voltage taps, a Hall sensor, and two strain gauges were used for the instrumentation. We obtained strains exceeding 0.4% near the outward edge during the coil current charge from 350 A to 390 A, where the coil was exposed to external axial and radial magnetic fields of 13 T and 0.5 T. Post mortem results showed wavy plastic deformation, electrical damage, and REBCO defects. An elastic-plastic simulation reproduced the measured strains and predicted that ∼1 GPa stress is sufficient to induce ∼0.9% strain, thus validating our initial concerns with purely elastic models. This paper provides our experimental and simulation results.

Bang, Jeseok (ORCID:0000000247616334)↗

Super resolution for magneto-optical microscopy

Sub-diffraction limited magneto-optical microscopy, such as Kerr or Faraday effect microscopy, provide many advantages to fields of science and technology for measuring, or imaging, the magnetization structures and magnetization domains of materials. Disclosed is a method and system for performing sub-diffraction limited magneto-optic microscopy. The method includes positioning a microlens or microlens layer relative to a surface of a sample to image the surface of the sample, forming a photonic nanojet to probe the surface of the sample, and receiving light reflected by the surface of the sample or transmitted through the sample at an imaging sensor. The methods and associated systems and devices enable sub-diffraction limited imaging of magnetic domains at resolutions 2 to 8 times the classical diffraction limit.

te Velthuis, Suzanne Gabriëlle Everdine↗

Eddy Current Model of a Coil Over An Infinite Perfectly Electrical Conductor (PEC) Half-Plane

Eddy current sensors measure the lift-off or distance between the sensor and a conducting surface. They operate on the principle of an alternating current in a conduction coil inducing a magnetic field within the surface. An eddy current is set up in the surface to counter the incident magnetic field which, in turn, sets up a magnetic field which counters that of the coil. This changes the coil impedance which is a function of the lift-off. As the lift-off increases, the effect of the eddy current magnetic field on the coil magnetic field weakens, resulting in a higher inductance and lower resistance. Thus, the lift-off may be derived from an impedance measurement. Dodd and Deeds developed an analytic model for an eddy current sensor coil impedance with an air core which has been implemented in MATLAB. LLNL assembled an eddy current sensor with a mu-metal core for which there is no analytic model. Rather than derive an analytic model which includes the mu-metal core, analytic empirically based functions are derived to map the Dodd and Deeds model to measured inductance and resistance.

42 ENGINEERING↗

Nanoscale covariance magnetometry with diamond quantum sensors

Nitrogen vacancy (NV) centers in diamond are atom-scale defects that can be used to sense magnetic fields with high sensitivity and spatial resolution. Typically, the magnetic field is measured by averaging sequential measurements of single NV centers, or by spatial averaging over ensembles of many NV centers, which provides mean values that contain no nonlocal information about the relationship between two points separated in space or time. In this work, we propose and implement a sensing modality whereby two or more NV centers are measured simultaneously, and we extract temporal and spatial correlations in their signals that would otherwise be inaccessible. We demonstrate measurements of correlated applied noise using spin-to-charge readout of two NV centers and implement a spectral reconstruction protocol for disentangling local and nonlocal noise sources.

47 OTHER INSTRUMENTATION↗

Signal amplification in a solid-state sensor through asymmetric many-body echo

Electronic spins of nitrogen–vacancy centres in diamond constitute a promising system for micro- and nanoscale magnetic sensing, because of their operation under ambient conditions, ease of placement in close proximity to sensing targets and biological compatibility. At high densities, the electronic spins interact through dipolar coupling, which typically limits but can also potentially enhance sensing performance. Here we report the experimental demonstration of many-body signal amplification in a solid-state, room-temperature quantum sensor. Our approach uses time-reversed two-axis-twisting interactions, engineered through dynamical control of the quantization axis and Floquet engineering in a two-dimensional ensemble of nitrogen–vacancy centres. We observe that optimal amplification occurs when the backward evolution time equals twice the forward evolution time, in sharp contrast to the conventional Loschmidt echo. These observations can be understood as resulting from an underlying time-reversed mirror symmetry of the microscopic dynamics, providing key insights into signal amplification and opportunities for practical entanglement-enhanced quantum sensing.

quantum information↗

Acoustic MEMS Sensor Array for Quench Detection of CICC Superconducting Cables

A novel quench detection method using microelectro- mechanical system (MEMS) sensor technology has been investigated in use for high temperature superconducting (HTS) conductors such REBCO tape cables. The sensor array along a superconducting cable, such as a cable-in-conduit-conductor (CICC), is installed in a cooling channel. It will allow sensitive and quick detection for a local quench of a superconducting cable. This work has confirmed that a quench of a single REBCO tape can be detected in liquid nitrogen by a MEMS piezoelectric microphone sensor. The quench detection design utilizing a MEMS sensor array method is discussed for the case of a toroidal field (TF) magnets of a fusion Tokamak device.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Functional metal–organic frameworks as effective sensors of gases and volatile compounds

Developing efficient sensor materials with superior performance for selective, fast and sensitive detection of gases and volatile organic compounds (VOCs) is essential for human health and environmental protection, through monitoring indoor and outdoor air pollutions, managing industrial processes, controlling food quality and assisting early diagnosis of diseases. Metal–organic frameworks (MOFs) are a unique type of crystalline and porous solid material constructed from metal nodes (metal ions or clusters) and functional organic ligands. They have been investigated extensively for possible use as high performance sensors for the detection of many different gases and VOCs in recent years, due to their large surface area, tunable pore size, functionalizable sites and intriguing properties, such as electrical conductivity, magnetism, ferroelectricity, luminescence and chromism. The high porosity of MOFs allows them to interact strongly with various analytes, including gases and VOCs, thus resulting in easily measurable responses to different physicochemical parameters. Although much of the recent work on MOF-based luminescent sensors have been summarized in several excellent reviews (up to 2018), a comprehensive overview of these materials for sensing gases and VOCs based on chemiresistive, magnetic, ferroelectric, and colorimertic mechanisms is missing. In this review, we highlight the most recent progress in developing MOF sensing and switching materials with an emphasis on sensing mechanisms based on electricity, magnetism, ferroelectricity and chromism. We provide a comprehensive analysis on the MOF–analyte interactions in these processes, which play a key role in the sensing performance of the MOF-based sensors and switches. We discuss in detail possible applications of MOF-based sensing and switching materials in detecting oxygen, water vapor, toxic industrial gases (such as hydrogen sulfide, ammonia, sulfur dioxide, nitrous oxide, carbon oxides and carbon disulfide) and VOCs (such as aromatic and aliphatic hydrocarbons, ketones, alcohols, aldehydes, chlorinated hydrocarbons and N,N'-dimethylformamide). Altogether, this review serves as a timely source of information and provides insight for the future development of advanced MOF materials as next-generation gas and VOC sensors.

36 MATERIALS SCIENCE↗

High-precision chemical quantum sensing in flowing monodisperse microdroplets

A method is presented for high-precision chemical detection that integrates quantum sensing with droplet microfluidics. Using nanodiamonds (ND) with fluorescent nitrogen-vacancy (NV) centers as quantum sensors, rapidly flowing microdroplets containing analyte molecules are analyzed. A noise-suppressed mode of optically detected magnetic resonance is enabled by pairing controllable flow with microwave control of NV electronic spins, to detect analyte-induced signals of a few hundredths of a percent of the ND fluorescence. Using this method, paramagnetic ions in droplets are detected with low limit-of-detection using small analyte volumes, with exceptional measurement stability over >10 3 s. In addition, these droplets are used as microconfinement chambers by co-encapsulating ND quantum sensors with various analytes such as single cells, suggesting wide-ranging applications including single-cell metabolomics and real-time intracellular measurements from bioreactors. Important advances are enabled by this work, including portable chemical testing devices, amplification-free chemical assays, and chemical imaging tools for probing reactions within microenvironments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thresholded quantum sensing with a frustrated Kitaev trimer

We investigate the response of a Ramsey interferometric quantum sensor based on a frustrated, three-spin system (a Kitaev trimer) to a classical time-dependent field (signal). The system eigenspectrum is symmetric about a critical point, |𝒃| = 0, with four of the spectral components varying approximately linearly with the magnetic field and four exhibiting a nonlinear dependence. Under the adiabatic approximation and for appropriate initial states, we show that the sensor's response to a zero-mean signal is such that below a threshold, |𝒃| <⁢ 𝑏 th , the sensor does not respond to the signal, whereas above the threshold, the sensor acts as a detector that the signal has occurred. This thresholded response is approximately omnidirectional. Moreover, when deployed in an entangled multisensor configuration, the sensor achieves sensitivity at the Heisenberg limit. Such detectors could be useful both as stand-alone units for signal detection above a noise threshold and in two- or three-dimensional arrays, analogous to a quantum bubble chamber, for applications such as particle track detection and long-baseline telescopy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

QUPITER -- Space Quantum Sensors for Jovian-Bound Dark Matter

We propose utilizing space quantum sensors to detect ultralight dark matter (ULDM) bound to planetary bodies, focusing on Jupiter as the heaviest planet in the solar system. Leveraging Jupiter's deep gravitational potential and the wealth of experience from numerous successful missions, we present strong sensitivity projections on the mass and couplings of scalar ULDM. Future space missions offer unique opportunities to probe the ULDM interactions using quantum sensors, including superconducting quantum interference device (SQUID) magnetometers. By measuring dark matter-induced magnetic field oscillations, we expect to achieve sensitivity orders of magnitude beyond the terrestrial probes and significantly improve detection prospects of theoretically motivated ULDM candidates.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nuclear spin metrology with nitrogen vacancy center in diamond for axion dark matter detection

We present a method to directly detect the axion dark matter using nitrogen vacancy centers in diamonds. In particular, we use metrology leveraging the nuclear spin of nitrogen to detect axion-nucleus couplings. This is achieved through protocols designed for dark matter searches, which introduce a novel approach of quantum sensing techniques based on the nitrogen vacancy center. Although the coupling strength of the magnetic fields with nuclear spins is three orders of magnitude smaller than that with electron spins for conventional magnetometry, the axion interaction strength with nuclear spins is the same order of magnitude as that with electron spins. Furthermore, we can take advantage of the long coherence time by using the nuclear spins for the axion dark matter detection. Our method has the potential to be sensitive to a broad frequency range ≲ 100 Hz corresponding to the axion mass m a ≲ 4 × 10 − 13 eV . We present the detection limit of our method for both the axion-neutron and the axion-proton couplings and discuss its significance in comparison with other proposed ideas. We also show that the sensitivities of the NV center sensor to various spin species will open up new directions for constructing protocols that can mitigate magnetic noise effects. Published by the American Physical Society 2025

Chigusa, So (ORCID:0000000160054447)↗

All-optical, Microwave-free NV-Diamond Magnetometer for Weak Magnetic Field Environments

Sensitive nitrogen-vacancy (NV) magnetometry typically requires a bias field to lift the spin level degeneracy and has commonly utilized microwave sources to selectively manipulate the sensor's spin state. However, this external bias field and microwave sources may perturb the sample of interest or be incompatible with operational conditions. Here, we demonstrate an all-optical, microwave-free NV-diamond magnetometer in the presence of weak or no bias magnetic field (<20 G). We experimentally measure photoluminescence spectra using diamonds with varying NV concentrations; and numerically simulate matching features due to cross-relaxation between NVs. Our results pave the way towards a sensitive probe to study magnetic systems that can be disrupted by microwave signals and can only tolerate weak bias magnetic field.

Ung, Kristine↗

A cryogenic white light absorption spectroscopy setup with in situ gamma irradiation and thermo-optical annealing for optical fiber radiation-induced attenuation characterization

Silica optical fiber sensors offer a fast, distributed measurement solution in various cryogenic and radiation environments, such as magnets for fusion power. Under these conditions, light-absorbing point defects limit lifetime via radiation-induced attenuation (RIA). To support RIA kinetics prediction, we present an in situ, broadband absorption spectroscopy setup combining gamma irradiation with liquid nitrogen cooling. The apparatus enables continuous monitoring of narrowband RIA levels and the use of secondary optical annealing light sources, alongside broadband spectrum measurements to characterize RIA defects through spectrum decomposition. Initial results confirm the inevitable photobleaching effect of the probe light source, which must be accounted for. In addition, we report RIA kinetics during cycles of gamma irradiation at 77 K and isochronal thermal annealing steps from liquid nitrogen to room temperature, showcasing the setup’s ability to replicate real fiber operation scenarios. These instruments form an ideal platform to further study the kinetics of RIA coupled with thermal and optical annealing.

Absorption spectroscopy↗

Fiber-Optic Silicon Fabry-Perot Interferometric Bolometer: The Influence of Mechanical Vibration and Magnetic Field

Plasma radiation plays an important role in the operation and control of magnetic confinement fusion and is typically measured by bolometers. Here, we study the influence of mechanical vibration and magnetic field, which are typically present in magnetic confinement fusion devices, on the performance of a fiber-optic bolometer (FOB) based on silicon Fabry-Perot interferometer (FPI) demodulated by a scanning diode laser. It is found that both the vibration and magnetic field could cause large noise due to the birefringence of the silicon FPI. To mitigate the birefringence effects, we demonstrated two effective methods: polarization maintaining FOB and polarization scrambling. We show that two methods can be effective in mitigating the effect caused by the sensor birefringence: (1) replacing the regular single-mode fiber in the FOB system with polarization-maintaining fiber and (2) using a polarization scrambler after the laser source. For both methods, no significant increase in the noise was observed in the vibration and magnetic field tests. Finally, our research highlights the importance of the polarization management for the FOB systems toward their practical applications in magnetic-confinement fusion systems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Flux Balancing Control of Ungapped Nanocrystalline Core-Based Transformer in Dual Active Bridge Converters

Transformer flux dc bias is a critical issue, impacting the reliable operation of dual active bridge (DAB) converters especially when ungapped high permeability nanocrystalline core is used. Steady state current dc bias can easily saturate ungapped nanocrystalline transformers, and it is even more dangerous in transient conditions. A dc bias model is proposed to analyze steady state dc bias in different load conditions. The magnetizing current detection is necessary for closed-loop control of dc bias; conductors' position is shown to impact sensor noise, and it is analyzed in detail. To deal with both steady state and transient dc bias, a unified flux balancing control (UFBC) is proposed introducing a predictive bias suppression (PBS) method with closed-loop flux balancing control (CFBC). With the proposed PBS, both primary/secondary current balance and flux balance can be achieved within one switching cycle using UFBC. Power characteristics and interaction between power control and flux balancing control of DAB converters are analyzed, and the CFBC needs to work in a low bandwidth due to sensor bandwidth limitation and interaction between power control and flux balancing control. Lastly, the UFBC is verified on a 300-kW cascaded DAB converter prototype.

42 ENGINEERING↗

A rapid heating and high magnetic field thermal analysis technique

Abstract A new thermal analysis technique is described that allows measurements to be performed on bulk samples at extreme heating and cooling rates and in high magnetic fields. High heating rates, up to 1000 °C min −1 , are achieved through electromagnetic induction heating of a custom-built apparatus fitted with commercial thermal analysis heads and sensor. Rapid cooling rates, up to 100 °C min −1 , are enabled by gas quenching and the small thermal mass of the induction furnace. The custom apparatus is designed to fit inside a superconducting magnet capable of fields up to 9 Tesla. This study demonstrates that the instrument is capable of collecting accurate thermal analysis data in high magnetic fields and rapidly acquiring data for dynamic processes. While the full potential of the technique is still unrealized, currently, it can provide insight into phenomena at time scales relevant to heat treatment in many industrial processes and into little understood effects of high magnetic field processing.

47 OTHER INSTRUMENTATION↗

Probing many-body dynamics in a two-dimensional dipolar spin ensemble

Abstract The most direct approach for characterizing the quantum dynamics of a strongly interacting system is to measure the time evolution of its full many-body state. Despite the conceptual simplicity of this approach, it quickly becomes intractable as the system size grows. An alternate approach is to think of the many-body dynamics as generating noise, which can be measured by the decoherence of a probe qubit. Here we investigate what the decoherence dynamics of such a probe tells us about the many-body system. In particular, we utilize optically addressable probe spins to experimentally characterize both static and dynamical properties of strongly interacting magnetic dipoles. Our experimental platform consists of two types of spin defects in nitrogen delta-doped diamond: nitrogen-vacancy colour centres, which we use as probe spins, and a many-body ensemble of substitutional nitrogen impurities. We demonstrate that the many-body system’s dimensionality, dynamics and disorder are naturally encoded in the probe spins’ decoherence profile. Furthermore, we obtain direct control over the spectral properties of the many-body system, with potential applications in quantum sensing and simulation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simulation of a scintillator-based fast ion loss detector for steady-state operation in Wendelstein 7-X (invited)

A quantitative theoretical framework has been created to model neutral beam injection and fast ion losses in the Wendelstein 7-X (W7-X) stellarator, including a novel method to develop synthetic diagnostics for fast ion loss detectors (FILDs) of many types, such as scintillating and Faraday Cup FILDs. This is the first time that this has been done in stellarator geometry with this level of fidelity, providing a way for fast ion losses to be predicted more precisely in future stellarator experiments and in W7-X. Simulations of the signal seen by a Faraday Cup FILD have been completed for multiple W7-X plasmas and show close agreement with the measured signals. This method is now applied to an actively water-cooled, scintillator-based FILD, which is currently in development to measure the fast ion loss distribution in W7-X in greater detail. The design makes use of a double slit to measure energy-and-pitch-angle-resolved losses of both co-going and counter-going fast ions. The diagnostic, which can be inserted to different radial positions, has been designed to withstand steady-state heat fluxes of up to 120 kW/m 2 along with additional transient heat loads of 100 kW/m 2 lasting for up to 20 s at a time. Simulations of W7-X standard magnetic configuration show up to 8 × 10 13 (s –1 cm –2 ) ion fluxes onto the sensor from each neutral beam source and no signal from the counter-going slit. Finally, these simulations will help inform experimental proposals for future W7-X campaigns after installation of this diagnostic.

3D printing↗