Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “METROLOGY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Effect of Boron Doping on High-Resolution X-Ray Diffraction Metrology

The effect of boron (B) doping on high-resolution X-ray diffraction (HXRD) metrology has been investigated. Twelve samples of Si{sub 1–x}Ge{sub x} films were epitaxially grown on Si (100) substrates with different thicknesses, germanium (Ge) concentrations and with/without B dopants. Secondary ion mass spectroscopy (SIMS) and HXRD were employed for measurements of B doping, Ge concentration, strain, and thickness of the layers. The SIMS results show the absence of B in two samples while the rest of the samples have B doping in the range of 8.40 × 10{sup 18}–8.7 × 10{sup 20} atoms/cm{sup 3} with Ge concentration of 13.3–55.2 at.%. The HXRD measurements indicate the layers thickness of 7.07–108.13 nm along with Ge concentration of 12.82–49.09 at.%. The difference in the Ge concentration measured by SIMS and HXRD was found to deend on B doping. For the undoped samples, the difference is ~0.5 at.% and increases with B doping but with no linear proportionality. The difference in the Ge concentration was 7.11 at.% for the highly B-doped (8.7 × 10{sup 20} atoms/cm{sup 3}) sample. The B doping influences the Si{sub 1–x}Ge{sub x} structure, causing a change in the lattice parameter and producing tensile strains shifting Si{sub 1–x}Ge{sub x} peaks towards Si (100) substrate peaks in the HXRD diffraction patterns. As a result, Vegard’s law is no longer effective and makes a high impact on the HXRD measurement. The comparison between symmetric (004) and asymmetric (+113, +224) reciprocal space mappings (RSM) showed a slight difference in Ge concentration between the undoped and lower B-doped samples. However, there is a change of 0.21 at.% observed for the highly doped Si{sub 1–x}Ge{sub x} samples. RSM’s (+113) demonstrate the small SiGe peak broadening as B doping increases, which indicates a minor crystal distortion.

36 MATERIALS SCIENCE↗

Harnessing on-machine metrology data for prints with a surrogate model for laser powder directed energy deposition

In this study, we leverage the massive amount of multi-modal on-machine metrology data generated from Laser Powder Directed Energy Deposition (LP-DED) to construct a comprehensive surrogate model of the 3D printing process. By employing Dynamic Mode Decomposition with Control (DMDc), a data-driven technique, we capture the complex physics inherent in this extensive dataset. This physics-based surrogate model emphasizes thermodynamically significant quantities, enabling us to accurately predict key process outcomes. The model ingests 21 process parameters, including laser power, scan rate, and position, while providing outputs such as melt pool temperature, melt pool size, and other essential observables. Furthermore, it incorporates uncertainty quantification to provide bounds on these predictions, enhancing reliability and confidence in the results. We then deploy the surrogate model on a new, unseen part and monitor the printing process as validation of the method. Our experimental results demonstrate that the predictions align with actual measurements with high accuracy, confirming the effectiveness of our approach. Furthermore, this methodology not only facilitates real-time predictions but also operates at process-relevant speeds, establishing a basis for implementing feedback control in LP-DED.

Digital twins↗

Sub-shot-noise quantum metrology with entangled identical particles

The usual notion of separability has to be reconsidered when applied to states describing identical particles. A definition of separability not related to any a priori Hilbert space tensor product structure is needed: this can be given in terms of commuting subalgebras of observables. Accordingly, the results concerning the use of the quantum Fisher information in quantum metrology are generalized and physically reinterpreted.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Quantitative Method for In Situ Pump-Beam Metrology in 4D Ultrafast Electron Microscopy

In this work, we report a method for measuring spot size and focusing conditions of the femtosecond (fs) excitation laser in situ at the specimen location in 4D ultrafast electron microscopy (UEM). The method makes use of threshold laser ablation behaviors of thin amorphous carbon membranes. For Gaussian beam profiles and for ablation threshold fluence values, we analytically derive expressions describing the relationship between ablated hole size and the actual laser spot size. Using these expressions, we developed experimental procedures for characterizing the shape and spot size of the pump beam at the specimen. We demonstrate the viability of the approach for incident excitation wavelengths of 343 nm and 515 nm, thus illustrating the applicability of the method to a range of optical wavelengths without modification. Further, we show that by measuring ablated hole size as a function of focusing condition, a full metrological characterization of the Gaussian beam propagation properties can be performed. Finally, we find good agreement for spot sizes determined with this method and with those determined by extrapolation from measurements taken outside the microscope column. Overall, this method is a simple, cost-effective means for accurate and precise determination of key pump-beam parameters in situ at the specimen location in UEM experiments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High precision metrology based microwave effective linewidth measurement technique

A precision microwave effective linewidth measurement technique for magnetic samples has been developed. The measurement utilizes a high-Q cylindrical cavity that contains the sample of interest, a highly stable and programable static magnetic field source, a computer controlled network analyzer for cavity center frequency {omega}{sub c} and quality factor Q{sub c} determinations, and the standard metrological substitution ABA method for accurate relative {omega}{sub c} and Q{sub c} measurements. Sequential long term ABA measurements show that the time and temperature drifts and random errors are the dominant sources of error, with uncertainties in {omega}{sub c}/2{pi} and Q{sub c} in the range of 50 kHz and 25, respectively. The ABA method is applied to eliminate these drifts and minimize the random errors. For measurements over 25 ABA cycles, accuracy is improved to 0.14 kHz for {omega}{sub c}/2{pi} and 3 for Q{sub c}. The temperature variation over a single ABA cycle is generally on the order of 10{sup -3}-10{sup -5} deg. C and there is no need for any further temperature stabilization or correction measures. The overall uncertainty in the 10 GHz effective linewidth determinations for a 3 mm diam, 0.5 mm thick polycrystalline yttrium iron garnet (YIG) disk is 0.15 Oe or less, well below the intrinsic single crystal YIG linewidth. This represents a factor of 10 improvement in measurement accuracy over previous work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Metrology And Standardization For Nanotechnologies

Metrology and standardization have a crucial role in the development of nanotechnologies. First Russian standards for nanotechnologies are considered. These standards are based on the use of silicon test objects-measures of small length at the nanoscale level. Characteristics of these test objects are presented.

36 MATERIALS SCIENCE↗

Conformal Doping of FINFETs: a Fabrication and Metrology Challenge

Whereas the introduction of 3D-dimensional devices such as FINFETs may be a solution for next generation technologies, they do represent significant challenges with respect to the doping strategies and the junction characterization. Aiming at a conformal doping, classical beam implants fail due to the differences in impact angle, ion incorporation efficiency and the effect of wafer rotation. Moreover shadowing represents an additional limitation for larger tilt angles when considering closely spaced FINs. Plasma immersion doping is an alternative approach which holds the promise of conformality but is also quite challenging and relies on secondary processes such as resputtering, deposition and in diffusion etc. Its implementation is compromised by concurrent artifacts, sputter erosion being the most important one. In support of these developments the measurement of the 3D-dopant distribution and the identification of conformality is essential requiring adequate metrology such as Scanning Spreading Resistance Microscopy, SIMS through FINs, resistors and the Tomographic Atomprobe.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantum resistance metrology in graphene

We performed a metrological characterization of the quantum Hall resistance in a 1 {mu}m wide graphene Hall bar. The longitudinal resistivity in the center of the {nu}={+-}2 quantum Hall plateaus vanishes within the measurement noise of 20 m{omega} up to 2 {mu}A. Our results show that the quantization of these plateaus is within the experimental uncertainty (15 ppm for 1.5 {mu}A current) equal to that in conventional semiconductors. The principal limitation of the present experiments is the relatively high contact resistances in the quantum Hall regime, leading to a significantly increased noise across the voltage contacts and a heating of the sample when a high current is applied.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quantum metrology with Bose-Einstein condensates

We show how a generalized quantum metrology protocol can be implemented in a two-mode Bose-Einstein condensate of n atoms, achieving a sensitivity that scales better than 1/n and approaches 1/n{sup 3/2} for appropriate design of the condensate.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

IR and THz Beamlines at the Metrology Light Source of the PTB

The low-energy electron storage ring Metrology Light Source (MLS), a dedicated synchrotron radiation source, is in user operation since April 2008. As a special option it provides coherent synchrotron radiation (CSR) in the THz range when it is operated in a low-alpha mode with short electron bunches. At the MLS three beamlines dedicated to the use of IR and THz radiation were designed, built and commissioned.

43 PARTICLE ACCELERATORS↗

A heterodyne interferometer for angle metrology

We have developed a compact, high-resolution, angle measurement instrument based on a heterodyne interferometer. Common-path heterodyne interferometer metrology is used to measure displacements of a reflective target surface. In the interferometer set up, an optical mask is used to sample the laser beam reflecting back from four areas on a target surface. From the relative displacement measurements of the target surface areas, we can simultaneously determine angular rotations around two orthogonal axes in a plane perpendicular to the measurement beam propagation direction. The device is used in a testbed for a tracking telescope system where pitch and yaw angle measurements of a flat mirror are performed. Angle noise measurement of the device shows 0.1 nrad/{radical}(Hz) at 1 Hz, at a working distance of 1 m. The operation range and nonlinearity of the device when used with a flat mirror is approximately {+-}0.15 mrad, and 3 {mu}rad rms, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FinFET Doping; Material Science, Metrology, and Process Modeling Studies for Optimized Device Performance

In this review paper the challenges that face doping optimization in 3-dimensional (3D) thin-body silicon devices will be discussed, within the context of material science studies, metrology methodologies, process modeling insight, ultimately leading to optimized device performance. The focus will be on ion implantation at the method to introduce the dopants to the target material.

36 MATERIALS SCIENCE↗

Sub-Planck structures and Quantum Metrology

The significance of sub-Planck structures in relation to quantum metrology is explored, in close contact with experimental setups. It is shown that an entangled cat state can enhance the accuracy of parameter estimations. The possibility of generating this state, in dissipative systems has also been demonstrated. Thereafter, the quantum Cramer-Rao bound for phase estimation through a pair coherent state is calculated, which achieves the maximum possible resolution in an interferometer.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

TSOM Method for Nanoelectronics Dimensional Metrology

Through-focus scanning optical microscopy (TSOM) is a relatively new method that transforms conventional optical microscopes into truly three-dimensional metrology tools for nanoscale to microscale dimensional analysis. TSOM achieves this by acquiring and analyzing a set of optical images collected at various focus positions going through focus (from above-focus to under-focus). The measurement resolution is comparable to what is possible with typical light scatterometry, scanning electron microscopy (SEM) and atomic force microscopy (AFM). TSOM method is able to identify nanometer scale difference, type of the difference and magnitude of the difference between two nano/micro scale targets using a conventional optical microscope with visible wavelength illumination. Numerous industries could benefit from the TSOM method--such as the semiconductor industry, MEMS, NEMS, biotechnology, nanomanufacturing, data storage, and photonics. The method is relatively simple and inexpensive, has a high throughput, provides nanoscale sensitivity for 3D measurements and could enable significant savings and yield improvements in nanometrology and nanomanufacturing. Potential applications are demonstrated using experiments and simulations.

36 MATERIALS SCIENCE↗

Atomic Layer Deposited Al{sub 2}O{sub 3} as Characterized Reference Samples for Nanolayer Metrology

Plasma assisted Atomic Layer Deposition Al{sub 2}O{sub 3} samples were studied using an approach of complementary metrology using Ellipsometry, X-Ray Reflectivity, Atomic Force Microscopy, and Total Reflection X-Ray Fluorescence. For modeling the samples, an interfacial rough SiO{sub 2} layer has to be assumed. The excellent linearity of the ALD process was used to cross check Ellipsometry and X-Ray Reflectivity. In contrast to Ellipsometry, X-Ray Reflectivity showed a residual surface layer, identified as chlorine contaminated layer by TXRF. The samples are shown to be ideal candidates for calibration of X-ray fluorescence as the Al signal linearly depends on the film thickness or ALD cycles. Furthermore, the impact of self-absorption of thick layers for TXRF was shown by the samples.

36 MATERIALS SCIENCE↗

Laser triggered Z-pinch broadband extreme ultraviolet source for metrology

We compare the extreme ultraviolet emission characteristics of tin and galinstan (atomic %: Ga: 78.35, In: 14.93, Sn: 6.72) between 10 nm and 18 nm in a laser-triggered discharge between liquid metal-coated electrodes. Over this wavelength range, the energy conversion efficiency for galinstan is approximately half that of tin, but the spectrum is less strongly peaked in the 13-15 nm region. The extreme ultraviolet source dimensions were 110 {+-} 25 {mu}m diameter and 500 {+-} 125 {mu}m length. The flatter spectrum, and -19 Degree-Sign C melting point, makes this galinstan discharge a relatively simple high radiance extreme ultraviolet light source for metrology and scientific applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of a spectroscopic Mueller matrix imaging ellipsometer for nanostructure metrology

In this paper, we describe the development of a spectroscopic Mueller matrix imaging ellipsometer (MMIE), which combines the great power of Mueller matrix ellipsometry with the high spatial resolution of optical microscopy. A dual rotating-compensator configuration is adopted to collect the full 4 × 4 imaging Mueller matrix in a single measurement. The light wavelengths are scanned in the range of 400–700 nm by a monochromator. The instrument has measurement accuracy and precision better than 0.01 for all the Mueller matrix elements in both the whole image and the whole spectral range. The instrument was then applied for the measurement of nanostructures combined with an inverse diffraction problem solving technique. The experiment performed on a photoresist grating sample has demonstrated the great potential of MMIE for accurate grating reconstruction from spectral data collected by a single pixel of the camera and for efficient quantification of geometrical profile of the grating structure over a large area with pixel resolution. It is expected that MMIE will be a powerful tool for nanostructure metrology in future high-volume nanomanufacturing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of space instruments at the Metrology Light Source

PTB has more than 20 years of experience in the calibration of space-based instruments using synchrotron radiation to cover the UV, VUV and X-ray spectral range. New instrumentation at the electron storage ring Metrology Light Source (MLS) opens up extended calibration possibilities within this framework. In particular, the set-up of a large vacuum vessel that can accommodate entire space instruments opens up new prospects. Moreover, a new facility for the calibration of radiation transfer source standards with a considerably extended spectral range has been put into operation. Besides, characterization and calibration of single components like e.g. mirrors, filters, gratings, and detectors is continued.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗