MCNP6 simulation of light and medium nuclei fragmentation at intermediate energies

Fragmentation reactions induced on light and medium nuclei by protons and light nuclei of energies around 1 GeV/nucleon and below are studied with the Los Alamos transport code MCNP6 and with its CEM03.03 and LAQGSM03.03 event generators. CEM and LAQGSM assume that intermediate-energy fragmentation reactions on light nuclei occur generally in two stages. The first stage is the intranuclear cascade (INC), followed by the second, Fermi breakup disintegration of light excited residual nuclei produced after the INC. CEM and LAQGSM account also for coalescence of light fragments (complex particles) up to sup>4 He from energetic nucleons emitted during INC. We investigate the validity and performance of MCNP6, CEM, and LAQGSM in simulating fragmentation reactions at intermediate energies and discuss possible ways of further improving these codes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The MCNP ® 6 code: A decade of progress

After several years of effort involved in merging the Los Alamos National Laboratory MCNP5 and MCNPX codes, in 2013 the first production release of version 6 of the Monte Carlo N-Particle ® , or MCNP ® , code MCNP6.1 was distributed publicly. Since then, three significant releases have been issued: MCNP6.1.1beta in 2014, MCNP6.2 in 2018, and MCNP6.3 in 2023. While each release always contains new features, code enhancements, and bug fixes, each version has had a different primary focus, ranging from improved calculational efficiency to new powerful utilities and tools, to software modernization of the code base. With all that has been learned over the first decade of the MCNP6 code, continuous progress is being made toward a modernized, general-purpose Monte Carlo radiation transport code that remains a trusted resource for the global community of practitioners. This paper describes these first 10+ years of the MCNP6 code and its continually improving data libraries, and gives some insight into how the next decade is expected to unfold.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A portable energy-sensitive cosmic neutron detection instrument

The construction and testing of a portable energy-sensitive neutron instrument are described. This instrument has been designed and constructed for the primary purpose of characterizing cosmic-ray neutron fields in the upper atmosphere and in cosmic reference field facilities. The instrument comprises a helium-3 proportional counter surrounded by 15 mm of lead and 140 mm of polyethylene creating a spherical structure with a diameter of 34 cm. The instrument also incorporates 12 boron-coated diodes, six on the outside of the polyethylene layer with six placed within the structure. The dimensions, materials, and arrangement of these in the instrument have previously been optimized with the MCNPX Monte Carlo simulation software to provide a compromise between the requirements of portability and spectral response. Testing took place at several locations and experimental data from the instrument's operation at the high-altitude Jungfraujoch laboratory in the Swiss alps are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Criticality Calculations for Step-2 GPHS Modules

The Multi-Mission Radioisotope Thermoelectric Generator (MMRTG) will use an improved version of the General Purpose Heat Source (GPHS) module as its source of thermal power. This new version, referred to as the Step-2 GPHS Module, has additional and thicker layers of carbon fiber material (Fine Weaved Pierced Fabric) for increased strength over the original GPHS module. The GPHS uses alpha decay of {sup 238}Pu in the oxide form as the primary source of heat, and small amounts of other actinides are also present in the oxide fuel. Criticality calculations have been performed by previous researchers on the original version of the GPHS module (Step 0). This paper presents criticality calculations for the present Step-2 version. The Monte Carlo N-Particle eXtended code (MCNPX) was used for these calculations. Numerous configurations of GPHS module arrays surrounded by wet sand and other materials (to reflect the neutrons back into the stack with minimal absorption) were modeled. For geometries with eight GPHS modules (from a single MMRTG) surrounded by wet sand, the configuration is extremely sub-critical; k{sub eff} is about 0.3. It requires about 1000 GPHS modules (from 125 MMRTGs) in a close-spaced stack to approach criticality (k{sub eff} = 1.0) when surrounded by wet sand. The effect of beryllium in the MMRTG was found to be relatively small.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Absolute calibration of image plates for electrons at energy between 100 keV and 4 MeV

We measured the absolute response of image plate (Fuji BAS SR2040) for electrons at energies between 100 keV and 4 MeV using an electron spectrometer. The electron source was produced from a short pulse laser irradiated on solid density targets. This paper presents the calibration results of image plate photon stimulated luminescence per electron at this energy range. The Monte Carlo radiation transport code MCNPX results are also presented for three representative incident angles onto the image plates and corresponding electron energy depositions at these angles. These provide a complete set of tools that allows extraction of our absolute calibration to other spectrometer setting at this electron energy range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron spectrometer for ITER using silicon detectors

High resolution neutron spectrometers provide information about plasma parameters at existing fusion experiments. Such a system may also be employed at ITER. Proton recoil telescopes have classically been used to detect neutrons with good energy resolution but poor efficiency. Using annular silicon detectors, it is possible to greatly increase the solid angle coverage and hence improve efficiency. Based on a simulation (MCNPX) study, the scaling of energy resolution, efficiency, and time to determine an ion temperature to 10% accuracy on foil thickness and detector location is shown. The latter quantity is used to determine the optimum foil thickness and detector geometry for specific plasma temperatures. For a 20 keV deuterium-tritium (DT) plasma, 5.3% resolution with efficiency of 2.9x10{sup -4} n cm{sup 2} is attainable using the available detectors. This gives a temperature measurement with 10% accuracy in 1.1 ms for a neutron flux of 2x10{sup 9} n cm{sup -2}. Multiple detectors can be used to further increase the efficiency if needed. A system of this kind could be tested in a future DT campaign at, for example, JET.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fluence-to-Absorbed Dose Conversion Coefficients for Use in Radiological Protection of Embryo and Foetus Against External Exposure to Muons from 20MeV to 50GeV

This study used the Monte-Carlo code MCNPX to determine mean absorbed doses to the embryo and foetus when the mother is exposed to external muon fields. Monoenergetic muons ranging from 20 MeV to 50 GeV were considered. The irradiation geometries include anteroposterior (AP), postero-anterior (PA), lateral (LAT), rotational (ROT), isotropic (ISO), and top-down (TOP). At each of these irradiation geometries, absorbed doses to the foetal body were calculated for the embryo of 8 weeks and the foetus of 3, 6 or 9 months, respectively. Muon fluence-to-absorbed-dose conversion coefficients were derived for the four prenatal ages. Since such conversion coefficients are yet unknown, the results presented here fill a data gap.

54 ENVIRONMENTAL SCIENCES↗

Out-of-field Dose for Scanned and Scattered Proton Beams

The dose delivered outside of the primary field to non-target tissues is of concern in all types of radiotherapy. For a given radiation type, this dose is dependent upon the delivery technique. Proton beams may be spread laterally to cover the target volume using scattering foils or magnetic scanning. Although scattered beams always use apertures or multi-leaf collimators to limit the radiation to normal tissues, scanning beams may or may not use them. A direct comparison of out-of-field dose for different proton delivery techniques has been thwarted because no institution had, as of April 2008, used multiple delivery techniques and comparisons have had to make extrapolations from measurements or calculations made using different field sizes, ranges, modulations, collimator-to-skin distances, and collimator materials. In this study, the Monte Carlo program MCNPX was used to simulate the dose deposited outside of the primary field for scattered/collimated (STC), scanned/collimated (SNC), and scanned/uncollimated (SNU) beams that have the same field size and penetration depth within a simulated patient. The out-of-field doses ranged from 10{sup -2} to 10{sup -7} of the prescribed dose. The ratio of STC to SNU dose varied from 2 to 420 depending upon the depth and distance off-axis while the SNC to SNU dose varied from 1.2 to 140. As the out-of-field doses are very small for all beam delivery techniques, decisions regarding which technique is appropriate for a given patient or facility should be based upon the magnitude of the out-of-field dose per unit prescribed dose and other issues rather than the ratio of doses for the different beam delivery techniques.

61 RADIATION PROTECTION AND DOSIMETRY↗

Development and Testing of Gallium Arsenide Photoconductive Detectors for Ultra Fast, High Dose Rate Pulsed Electron and Bremsstrahlung Radiation Measurements

Real time radiation dose measurements are challenging in high dose rate environments such as those used for testing electronic devices or biological agents. Dosimetry needs in pulsed reactor fields and particle accelerator facilities require development of dosimeters with fast (10 s of picoseconds) response to pulsed radiation, linear response over a wide range of dose rates (up to 10{sup 11} Gy/s), high resistance to radiation damage, and successful operation in mixed gamma and neutron environments. Gallium arsenide photoconductive detectors (GaAs PCD) have been shown to exhibit many of these desirable characteristics, especially fast time response. Less than 50 ps time resolution has been demonstrated when previously irradiated by fission neutrons. We have conducted a study of the response-time dependence on neutron fluence, starting with fluences at {approx}10{sup 14} n/cm{sup 2}. A 23-MeV electron beam was used to produce photoneutrons in a tungsten target for irradiation of a GaAs wafer from which PCDs were made. The process was modeled using MCNPX computer code and the simulation results were compared to the experimental measurements. GaAs PCDs were fabricated from both neutron-irradiated and non-irradiated GaAs samples. The results of the preliminary tests of these devices in accelerator-produced pulses of electron and bremsstrahlung radiation of various energies (13 to 35 MeV) and pulse lengths (100 ps to 4 {mu}s) are presented together with an overview of the future plans of continuing GaAs PCD research at Idaho State University.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of a Compact Gamma Tube Interrogation Source

Active interrogation with high-energy monoenergetic gammas can induce photofission signals in fissile materials while minimizing absorbed radiation dose and background from surrounding materials. A first-generation axial-type gamma generator has been developed that utilizes the {sup 11}B(p,{gamma}){sup 12}C nuclear reaction at a 163 keV resonance to produce monoenergetic 12-MeV gamma-rays. The gamma tube employs a water-cooled cylindrical radio frequency (if) induction ion source capable of producing a proton current density of up to 100 mA/cm{sup 2}. The extracted proton beam bombards a lanthanum hexaboride (LaB{sub 6}) target at energies up to 200 keV. The 12-MeV gamma intensity was measured as a function of proton energy, beam current, and angle. Photofission-induced neutrons from depleted uranium (DU) were measured and compared to MCNPX calculations. After extended operation, the high power density of the proton beam was observed to cause damage to the LaB{sub 6} target and the gamma tube improvements currently being made to mitigate this damage are discussed.

07 ISOTOPE AND RADIATION SOURCES↗

14-MeV Neutron Generator Used as a Thermal Neutron Source

One of the most important applications of the general purpose Monte Carlo N-Particle (MCNP5 and MCNPX) codes is neutron shielding design. We employed this method to simulate the shielding of a 14-MeV neutron generator used as a thermal neutron source providing an external thermal neutron beam for testing large area neutron detectors developed for diffraction studies in biology and also useful for national security applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron and high energy deuteron anisotropy investigations in plasma focus device

The anisotropies of neutron and high energy deuteron emissions from the NX2 plasma focus device [M. V. Roshan et al., Phys. Lett. A 373, 851 (2009)] are studied. The nuclear activation of graphite targets is used to measure the fluences of high energy deuterons in the axial and radial directions. Two bismuth germanate scintillation detectors connected to multichannel analyzer systems are used for the detection of 511 keV gamma rays resulting from positron annihilation in the two targets. In addition, fast neutron activation detectors are employed to measure the axial and radial fluences of fusion neutrons. These detection systems are calibrated using the simulation code MCNPX[L. S. Waters et al., AIP Conf. Proc. 896, 81 (2007)]. Two distinct regimes of neutron and deuteron anisotropies are observed for the NX2 device. For deuterium gas pressures below 10 mbar, the neutron anisotropy increases with increasing pressure, while the overall neutron yield remains low. For gas pressures of 10-14 mbar, the neutron anisotropy is essentially constant, while, with increasing pressure, the neutron yield rises rapidly and the deuteron anisotropy falls.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparison of GEANT4 Simulations with Experimental Data for Thick Al Absorbers

Proton beams in medical applications deal with relatively thick targets like the human head or trunk. Therefore, relatively small differences in the total proton stopping power given, for example, by the different models provided by GEANT4 can lead to significant disagreements in the final proton energy spectra when integrated along lengthy proton trajectories. This work presents proton energy spectra obtained by GEANT4.8.2 simulations using ICRU49, Ziegler1985 and Ziegler2000 models for 19.68 MeV protons passing through a number of Al absorbers with various thicknesses. The spectra were compared with the experimental data, with TRIM/SRIM2008 and MCNPX2.4.0 simulations, and with the Payne analytical solution for the transport equation in the Fokker-Plank approximation. It is shown that the MCNPX simulations reasonably reproduce well all experimental spectra. For the relatively thin targets all the methods give practically identical results but this is not the same for the thick absorbers. It should be noted that all the spectra were measured at the proton energies significantly above 2 MeV, i.e., in the so-called 'Bethe-Bloch region'. Therefore the observed disagreements in GEANT4 results, simulated with different models, are somewhat unexpected. Further studies are necessary for better understanding and definitive conclusions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Optimization of Neutron Shielding for the PICASSO Experiment

The PICASSO experiment searches WIMPs via their spin-dependent interactions with nuclei. At their operating temperatures, PICASSO threshold detectors are not sensitive to {gamma}-rays, while it is necessary to suppress neutron and {alpha}-ray backgrounds. The different types of neutron shielding (water, polyethylene, borated water and polyethylene doped with different compounds of boron and lithium) were studied via the Monte Carlo method using MCNPX code. Efficiencies of these different types of neutron shielding were compared from the point of view of neutron suppression as well as number of newly born y-rays. The neutrons and {gamma}-rays were followed up to the PICASSO detector active material. The most suitable neutron shielding for the PICASSO experiment was determined following these simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reduced Calibration Curve for Proton Computed Tomography

The pCT deals with relatively thick targets like the human head or trunk. Thus, the fidelity of pCT as a tool for proton therapy planning depends on the accuracy of physical formulas used for proton interaction with thick absorbers. Although the actual overall accuracy of the proton stopping power in the Bethe-Bloch domain is about 1%, the analytical calculations and the Monte Carlo simulations with codes like TRIM/SRIM, MCNPX and GEANT4 do not agreed with each other. A tentative to validate the codes against experimental data for thick absorbers bring some difficulties: only a few data is available and the existing data sets have been acquired at different initial proton energies, and for different absorber materials. In this work we compare the results of our Monte Carlo simulations with existing experimental data in terms of reduced calibration curve, i.e. the range - energy dependence normalized on the range scale by the full projected CSDA range for given initial proton energy in a given material, taken from the NIST PSTAR database, and on the final proton energy scale - by the given initial energy of protons. This approach is almost energy and material independent. The results of our analysis are important for pCT development because the contradictions observed at arbitrary low initial proton energies could be easily scaled now to typical pCT energies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte Carlo and Analytical Calculation of Lateral Deflection of Proton Beams in Homogeneous Targets

Proton radiation therapy is a precise form of radiation therapy, but the avoidance of damage to critical normal tissues and the prevention of geographical tumor misses require accurate knowledge of the dose delivered to the patient and the verification of his position demand a precise imaging technique. In proton therapy facilities, the X-ray Computed Tomography (xCT) is the preferred technique for the planning treatment of patients. This situation has been changing nowadays with the development of proton accelerators for health care and the increase in the number of treated patients. In fact, protons could be more efficient than xCT for this task. One essential difficulty in pCT image reconstruction systems came from the scattering of the protons inside the target due to the numerous small-angle deflections by nuclear Coulomb fields. The purpose of this study is the comparison of an analytical formulation for the determination of beam lateral deflection, based on Moliere's theory and Rutherford scattering with Monte Carlo calculations by SRIM 2008 and MCNPX codes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Absolute measurements of fast neutrons using yttrium

Yttrium is presented as an absolute neutron detector for pulsed neutron sources. It has high sensitivity for detecting fast neutrons. Yttrium has the property of generating a monoenergetic secondary radiation in the form of a 909 keV gamma-ray caused by inelastic neutron interaction. It was calibrated numerically using MCNPX and does not need periodic recalibration. The total yttrium efficiency for detecting 2.45 MeV neutrons was determined to be f{sub n}{approx}4.1x10{sup -4} with an uncertainty of about 0.27%. The yttrium detector was employed in the NX2 plasma focus experiments and showed the neutron yield of the order of 10{sup 8} neutrons per discharge.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The EURISOL Multi-MW Target Unit: Neutronics, Dose Rate, Shielding and Activation Calculations

The EURISOL (The EURopean Isotope Separation On-Line Radioactive Ion Beam) project aims at designing a facility for producing high intensity radioactive ion beams, with unprecedented (two to three orders of magnitude higher) intensities, compared to the majority of the worldwide existing RIB facilities. For this purpose, a proton beam of energy 1 GeV and intensity up to 4 mA impinges on a liquid mercury target (the converter). The high neutron fluxes (in excess of 10{sup 15} n cm{sup -2} s{sup -1}) produced by spallation nuclear reactions in the converter induce fission on {sup 235}U targets surrounding the liquid mercury converter. In order to attain the intended high intensity radioactive ion beams, the appropriate configuration (geometry and materials) of the target unit components (converter, fission targets, moderators, reflectors) must be determined, to attain the highest possible fission rates in the uranium targets (in excess of 10{sup 15} fissions per second). The extremely high neutron and photon fluxes resulting from the operation of the target unit impose, for radiological protection and safety purposes, a careful assessment of the dose rates in the surrounding areas. Activation of the structural components must be studied. Thick shielding barriers must be designed. In this work, the so-called MAFF inspired target configuration, allowing a versatile operation, maintenance, remote control and storage of the fission targets is considered. The results obtained using the state-of-the-art Monte Carlo codes MCNPX and FLUKA are presented. The neutronics, dose rate, shielding and activation calculations, needed for radiological protection and safety assessment purposes are discussed.

43 PARTICLE ACCELERATORS↗