Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MCNP6”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

SU-F-T-111: Investigation of the Attila Deterministic Solver as a Supplement to Monte Carlo for Calculating Out-Of-Field Radiotherapy Dose

Purpose: To use the Attila deterministic solver as a supplement to Monte Carlo for calculating out-of-field organ dose in support of epidemiological studies looking at the risks of second cancers. Supplemental dosimetry tools are needed to speed up dose calculations for studies involving large-scale patient cohorts. Methods: Attila is a multi-group discrete ordinates code which can solve the 3D photon-electron coupled linear Boltzmann radiation transport equation on a finite-element mesh. Dose is computed by multiplying the calculated particle flux in each mesh element by a medium-specific energy deposition cross-section. The out-of-field dosimetry capability of Attila is investigated by comparing average organ dose to that which is calculated by Monte Carlo simulation. The test scenario consists of a 6 MV external beam treatment of a female patient with a tumor in the left breast. The patient is simulated by a whole-body adult reference female computational phantom. Monte Carlo simulations were performed using MCNP6 and XVMC. Attila can export a tetrahedral mesh for MCNP6, allowing for a direct comparison between the two codes. The Attila and Monte Carlo methods were also compared in terms of calculation speed and complexity of simulation setup. A key perquisite for this work was the modeling of a Varian Clinac 2100 linear accelerator. Results: The solid mesh of the torso part of the adult female phantom for the Attila calculation was prepared using the CAD software SpaceClaim. Preliminary calculations suggest that Attila is a user-friendly software which shows great promise for our intended application. Computational performance is related to the number of tetrahedral elements included in the Attila calculation. Conclusion: Attila is being explored as a supplement to the conventional Monte Carlo radiation transport approach for performing retrospective patient dosimetry. The goal is for the dosimetry to be sufficiently accurate for use in retrospective epidemiological investigations.

60 APPLIED LIFE SCIENCES↗

TH-CD-201-02: A Monte Carlo Investigation of a Novel Detector Arrangement for the Energy Spectrum Measurement of a 6MV Linear Accelerator

Purpose: Direct measurement of the energy spectrum of a 6MV linear accelerator has not been successful due to the high fluence rate, high energy nature of these photon beams. Previous work used a Compton Scattering (CS) spectrometry setup with a shielded spectrometer for spectrum measurements. Despite substantial lead shielding, excessive pulse pile-up was seen. MCNP6 transport code was used to investigate the feasibility and effectiveness of performing measurements using a novel detector setup. Methods: Simulations were performed with a shielded high-purity germanium (HPGe) semiconductor detector placed in the accelerator vault’s maze, with a 2 cm diameter collimator through a 92 cm thick concrete wall. The detector was positioned 660 cm from a scattering rod (placed at isocenter) at an angle of 45° relative to the central axis. This setup was compared with the shielded detector positioned in the room, 200 cm from the scattering rod at the same CS angle. Simulations were used to determine fluence contributions from three sources: (1) CS photons traveling through the collimator aperture, the intended signal, (2) CS scatter photons penetrating the detector shield, and (3) room-scattered photons penetrating the detector shield. Variance reduction techniques including weight windows, DXTRAN spheres, forced collisions, and energy cutoffs were used. Results: Simulations showed that the number of pulses per starting particle from an F8 detector tally for the intended signal decreased by a factor of 10{sup 2} when moving the detector out of the vault. This reduction in signal was amplified for the unwanted scatter signal which decreased by up to a factor of 10{sup 9}. Conclusion: This work used MCNP6 to show that using a vault wall to shield unwanted scatter and increasing isocenter-to-detector distance reduces unwanted fluence to the detector. This study aimed to provide motivation for future experimental work using the proposed setup.

07 ISOTOPE AND RADIATION SOURCES↗

Poster - 08: Preliminary Investigation into Collapsed-Cone based Dose Calculations for COMS Eye Plaques

Purpose: To investigate the accuracy of model-based dose calculations using a collapsed-cone algorithm for COMS eye plaques loaded with I-125 seeds. Methods: The Nucletron SelectSeed 130.002 I-125 seed and the 12 mm COMS eye plaque were incorporated into a research version of the Oncentra® Brachy v4.5 treatment planning system which uses the Advanced Collapsed-cone Engine (ACE) algorithm. Comparisons of TG-43 and high-accuracy ACE doses were performed for a single seed in a 30×30×30 cm{sup 3} water box, as well as with one seed in the central slot of the 12 mm COMS eye plaque. The doses along the plaque central axis (CAX) were used to calculate the carrier correction factor, T(r), and were compared to tabulated and MCNP6 simulated doses for both the SelectSeed and IsoAid IAI-125A seeds. Results: The ACE calculated dose for the single seed in water was on average within 0.62 ± 2.2% of the TG-43 dose, with the largest differences occurring near the end-welds. The ratio of ACE to TG-43 calculated doses along the CAX (T(r)) of the 12 mm COMS plaque for the SelectSeed was on average within 3.0% of previously tabulated data, and within 2.9% of the MCNP6 simulated values. The IsoAid and SelectSeed T(r) values agreed within 0.3%. Conclusions: Initial comparisons show good agreement between ACE and MC doses for a single seed in a 12 mm COMS eye plaque; more complicated scenarios are being investigated to determine the accuracy of this calculation method.

60 APPLIED LIFE SCIENCES↗

Computational Assessment of Naturally Occurring Neutron and Photon Background Radiation Produced by Extraterrestrial Sources

In this study, a computational assessment of the variation in terrestrial neutron and photon background from extraterrestrial sources is presented. The motivation of this assessment is to evaluate the practicality of developing a tool or database to estimate background in real time (or near–real time) during an experimental measurement or to even predict the background for future measurements. The extraterrestrial source focused on during this assessment is naturally occurring galactic cosmic rays (GCRs). The MCNP6 transport code was used to perform the computational assessment. However, the GCR source available in MCNP6 was not used. Rather, models developed and maintained by NASA were used to generate the GCR sources. The largest variation in both neutron and photon background spectra was found to be caused by changes in elevation on Earth's surface, which can be as large as an order of magnitude. All other perturbations produced background variations on the order of a factor of 3 or less. The most interesting finding was that ~80% and 50% of terrestrial background neutrons and photons, respectively, are generated by interactions in Earth's surface and other naturally occurring and man-made objects near a detector of particles from extraterrestrial sources and their progeny created in Earth's atmosphere. In conclusion, this assessment shows that it will be difficult to estimate the terrestrial background from extraterrestrial sources without a good understanding of a detector's surroundings. Therefore, estimating or predicting background during a measurement environment like a mobile random search will be difficult.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calculation of neutron flux spectra of the VVER-1000 mock-up shielding benchmark with Monte Carlo code MCS utilizing mesh-based weight window

The measurements of neutron spectra compiled inside the NEA-1517/82 package from the Shielding Integral Benchmark Archive and Database (SINBAD) are chosen as benchmark cases to validate the variance reduction technique based on weight window in Monte Carlo Code MCS. A full 3D model for fixed source mode calculation with hexagonal lattice source definition is developed to simulate total of 6 points of measurements at the vicinity of the reactor and the reactor pressure vessel region. A code/code comparison against MCNP6 code is first conducted as verification element for the mesh-based weight window capability in MCS. Finally, the validation results are presented against measurements. The verification against MCNP6 code gives good agreement in addition of the insight to the importance of user understanding to determine proper reference point and reference lower weight bound for scaling which is not required in MCS code due to its capability of automatic scaling. The comparison of neutron spectra between MCS and measurements shows good agreement within 3 standard deviations for all of six detector positions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

DHS Written Report

Recently, a new galactic cosmic-ray (GCR) source option [1] was implemented in the all-energy, all-particle transport code MCNP6 [2]. In this paper, we made use of this feature to calculate surface neutron and photon background fluxes on a terrestrial grid around the earth. These spectra have been incorporated into Release 2 of the 'background.dat' file, which is read and sampled by MCNP6 whenever a user invokes the background source option [2]. Cosmic radiation bombards Earth with various particles, such as protons and {alpha} particles, some of which are deflected by the Earth's shielding magnetic field. Particles that carry sufficient energy can overcome the deflection and penetrate into the atmosphere. The sufficient energy is dependent on the terrestrial coordinates due to the magnetic force's proportionality to the sine of the angle between the velocity vector of the incoming particle and the magnetic field. As the particles propagate through the atmosphere, collisions with atmospheric molecules generate new particles such as neutrons, protons, photons, muons, pions, and other exotic particles. These secondary often have sufficient energy to undergo additional nuclear interactions, and so on, forming what is known as a cascade shower. The tabulation of background particle fluxes on the surface of the earth is important for a variety of reasons, one of which is the design of nuclear material detection systems. The simulations used various models and formulations for the cosmic source spectra, atmosphere, and terrestrial conditions to correctly model the propagation of GCR particles through the atmosphere to surface level.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Preliminary Results of Investigating Precompound Emission of Light Fragments in Spallation Reactions, Summer 2012

Emission of light fragments (LF) from nuclear reactions is an open question. Different reaction mechanisms contribute to their production; the relative roles of each, and how they change with incident energy, mass number of the target, and the type and emission energy of the fragments is not completely understood. None of the available models are able to accurately predict emission of LF from arbitrary reactions. However, the ability to describe production of LF (especially at energies & 30 MeV) from many reactions is important for different applications, such as cosmic-ray induced Single Event Upsets (SEUs), radiation protection, and cancer therapy with proton and heavy-ion beams, to name just a few. The Cascade-Exciton Model (CEM), version 03.03 and the Los Alamos version of the Quark-Gluon String Model (LAQGSM), version 03.03 event generators in Monte Carlo N-Particle Transport Code version 6 (MCNP6), describe quite well the spectra of fragments with sizes up to 4 He across a broad range of target masses and incident energies (up to ∼ 5 GeV for CEM and up to ∼ 1 TeV/A for LAQGSM). However, they do not predict the high-energy tails of LF spectra heavier than 4 He well. Most LF with energies above several tens of MeV are emitted during the precompound stage of a reaction. The current versions of the CEM and LAQGSM event generators do not account for precompound emission of LF larger than 4 He. The aim of our work is to extend the precompound model to include such processes, leading to an increase of predictive power of LF-production in MCNP6. This entails upgrading the Modified Exciton Model currently used at the preequilibrium stage in CEM and LAQGSM. It will also include examination and extension of the coalescence and Fermi break-up models used in the precompound stages of spallation reactions within CEM and LAQGSM. Extending our models to include emission of fragments heavier than 4 He at the precompound stage has already provided preliminary results that have much better agreement with experimental data.

Atomic and Nuclear Physics↗

Adjoint-Based Uncertainty Quantification with MCNP

This work serves to quantify the instantaneous uncertainties in neutron transport simulations born from nuclear data and statistical counting uncertainties. Perturbation and adjoint theories are used to derive implicit sensitivity expressions. These expressions are transformed into forms that are convenient for construction with MCNP6, creating the ability to perform adjoint-based uncertainty quantification with MCNP6. These new tools are exercised on the depleted-uranium hybrid LIFE blanket, quantifying its sensitivities and uncertainties to important figures of merit. Overall, these uncertainty estimates are small (< 2%). Having quantified the sensitivities and uncertainties, physical understanding of the system is gained and some confidence in the simulation is acquired.

42 ENGINEERING↗

Production of Energetic Light Fragments in the Cascade Exciton Model (CEM)

Emission of light fragments (LF) from nuclear reactions is an open question because different reaction mechanisms contribute to their production, and the relative roles of each, and how they change with incident energy, mass number of the target, and the type and emission energy of the fragments is not completely understood. None of the available models are able to accurately predict emission of LF from arbitrary reactions. However, the ability to describe production of LF (especially at energies ≳ 30 MeV) from many reactions is important for different applications, such as cosmic-ray-induced Single Event Upsets (SEUs), radiation protection, and cancer therapy with proton and heavy ion beams, to name just a few. The Cascade-Exciton Model (CEM) version 03.03 and the Los Alamos version of the Quark-Gluon String Model (LAQGSM) version 03.03 event generators in Monte Carlo N-Particle Transport Code version 6 (MCNP6) describe well the spectra of fragments with sizes up to 4 He across a broad range of target masses and incident energies (up to ∼ 5 GeV for CEM and up to ∼ 1 TeV/A for LAQGSM). However, they do not predict the high-energy tails of LF spectra heavier than 4 He well because most LF with energies above several tens of MeV are emitted during the precompound stage of a reaction, and the current versions of the CEM and LAQGSM event generators do not account for pre compound emission of LF larger than 4 He. The aim of our work is to extend the precompound model in them to include emission of light fragments up to 28 Mg, leading to an increase of predictive power of LF-production in MCNP6. This entails upgrading the Modified Exciton Model currently used at the preequilibrium stage in CEM and LAQGSM. It will also include investigation and possible expansion of the coalescence and Fermi break-up models used in the precompound stages of spallation reactions within CEM and LAQGSM. Extending our models to include emission of fragments heavier than 4 He at the precompound stage has already provided preliminary results that have much better agreement with experimental data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

MCNP(TM) Release 6.1.1 beta: Creating and Testing the Code Distribution

This report documents the preparations for and testing of the production release of MCNP6™1.1 beta through RSICC at ORNL. It addresses tests on supported operating systems (Linux, MacOSX, Windows) with the supported compilers (Intel, Portland Group and gfortran). Verification and Validation test results are documented elsewhere. This report does not address in detail the overall packaging of the distribution. Specifically, it does not address the nuclear and atomic data collection, the other included software packages (MCNP5, MCNPX and MCNP6) and the collection of reference documents.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Methodology for Calculating Radiation Signatures

A rigorous formalism is presented for calculating radiation signatures from both Special Nuclear Material (SNM) as well as radiological sources. The use of MCNP6 in conjunction with CINDER/ORIGEN is described to allow for the determination of both neutron and photon leakages from objects of interest. In addition, a description of the use of MCNP6 to properly model the background neutron and photon sources is also presented. Examinations of the physics issues encountered in the modeling are investigated so as to allow for guidance in the user discerning the relevant physics to incorporate into general radiation signature calculations. Furthermore, examples are provided to assist in delineating the pertinent physics that must be accounted for. Finally, examples of detector modeling utilizing MCNP are provided along with a discussion on the generation of Receiver Operating Curves, which are the suggested means by which to determine detectability radiation signatures emanating from objects.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precompound Emission of Energetic Light Fragments in Spallation Reactions [Dissertation]

Emission of light fragments (LF) from nuclear reactions is an open question. Different reaction mechanisms contribute to their production; the relative roles of each, and how they change with incident energy, mass number of the target, and the type and emission energy of the fragments is not completely understood. None of the available models are able to accurately predict emission of LF from arbitrary reactions. However, the ability to describe production of LF (especially at energies ≳ 30 MeV) from many reactions is important for different applications, such as cosmic-ray-induced Single Event Upsets (SEUs), radiation protection, and cancer therapy with proton and heavy-ion beams, to name just a few. The Cascade-Exciton Model (CEM) version 03.03 and the Los Alamos version of the Quark-Gluon String Model (LAQGSM) version 03.03 event generators in Monte Carlo N-Particle Transport Code version 6 (MCNP6) describe quite well the spectra of fragments with sizes up to 4 He across a broad range of target masses and incident energies (up to ~ 5 GeV for CEM and up to ~ 1 TeV/A for LAQGSM). However, they do not predict the high energy tails of LF spectra heavier than 4 He well. Most LF with energies above several tens of MeV are emitted during the precompound stage of a reaction. The current versions of the CEM and LAQGSM event generators do not account for precompound emission of LF larger than 4 He. The aim of our work is to extend the precompound model in them to include such processes, leading to an increase of predictive power of LF-production in MCNP6. This entails upgrading the Modified Exciton Model currently used at the preequilibrium stage in CEM and LAQGSM. It also includes expansion and examination of the coalescence and Fermi break-up models used in the precompound stages of spallation reactions within CEM and LAQGSM. Extending our models to include emission of fragments heavier than 4 He at the precompound stage has indeed provided results that have much better agreement with experimental data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

DNDO Report

My internship program was the Domestic Nuclear Detection Office Summer Internship Program. I worked at Los Alamos National Laboratory with Trevor A. Wilcox and Gregg W. McKinney in the NEN-5 group. My project title was “MCNP Physical Model Interoperability & Validation”. The goal of my project was to write a program to predict the solar modulation parameter for dates in the future and then implement it into MCNP6. This update to MCNP6 can be used to calculate the background more precisely, which is an important factor in being able to detect Special Nuclear Material. We will share our work in a published American Nuclear Society (ANS) paper, an ANS presentation, and a LANL student poster session. Through this project, I gained skills in programming, computing, and using MCNP. I also gained experience that will help me decide on a career or perhaps obtain employment in the future.

42 ENGINEERING↗

Photon Next-Event Estimator Implementation in MCATK

A photon next-event fluence estimator at a point has been implemented in the Monte Carlo Application Toolkit (MCATK). The next-event estimator provides an expected value estimator for the flux at a point due to all source and collision events. An advantage of the next-event estimator over track-length estimators, which are normally employed in MCATK, is that flux estimates can be made in locations that have no random walk particle tracks. The next-event estimator allows users to calculate radiographs and estimate response for detectors outside of the modeled geometry. The next-event estimator is not yet accessable through the MCATK FlatAPI for C and Fortran. The next-event estimator in MCATK has been tested against MCNP6 using 5 suites of test problems. No issues were found in the MCATK implementation. One issue was found in the exclusion radius approximation in MCNP6. The theory, implementation, and testing are described in this document.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using Machine Learning to Predict MCNP Bias

For many real-world applications in radiation transport where simulations are compared to experimental measurements, like in nuclear criticality safety, the bias (simulated - experimental k eff ) in the calculation is an extremely important quantity used for code validation. The objective of this project is to accurately predict the bias of MCNP6 [1] criticality calculations using machine learning (ML) algorithms, with the intention of creating a tool that can complement the current nuclear criticality safety methods. In the latest release of MCNP6, the Whisper tool is available for criticality safety analysts and includes a large catalogue of experimental benchmarks, sensitivity profiles, and nuclear data covariance matrices. This data, coming from 1100+ benchmark cases, is used in this study of ML algorithms for criticality safety bias predictions.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Preliminary Criticality and Radiation Shielding Analysis for the Storage and Transfer of MARVEL Reactor Spent Nuclear Fuel

This report documents the results of preliminary nuclear criticality and radiation shielding assessments during transfer and dry storage of irradiated Microreactor Applications Research Validation and Evaluation (MARVEL) reactor fuel at Idaho National Laboratory (INL). The assessments focus on transfer casks and storage canisters that are currently in use at INL, which may be compatible with the irradiated MARVEL reactor fuel. The criticality assessments were performed using the radiation transport code MCNP6 with 37 MARVEL reactor fuel elements in various configurations and scenarios. All transfer and storage configurations under dry conditions were below the assumed criticality safety limit of 0.93. Some storage and transfer configurations under wet conditions exceeded the criticality safety limit. This suggests that the appropriate administrative and engineering controls, in addition to reducing the number of MARVEL reactor fuel elements per transfer cask or storage canister, can be expected to ensure criticality safety under all scenarios. The radiation shielding assessments were performed by generating conservative neutron and photon source terms using the ORIGEN module in the SCALE suite of codes. These source spectra were used to estimate the dose equivalent rates using the radiation transport code MCNP6, both on contact and 1 m away from the fuel and transfer casks. The maximum estimated dose equivalent rate of 37 unshielded MARVEL reactor fuel elements on contact is approximately 42000 R/hr. The maximum estimated dose equivalent rates on contact to the ATR transfer cask, HFEF-5 transfer cask, and high load charger were approximately 233 mR/hr, 171 mR/hr, and 201 mR/hr, respectively. This suggests that with the appropriate administrative and engineering controls, all three transfer casks analyzed can be expected to provide sufficient radiation shielding to workers during transfer of irradiated MARVEL reactor fuel. These calculations are performed to support the planning and strategy for the MARVEL project and will demonstrate the technical viability of the different configurations discussed and help identify where engineered or administrative controls may be necessary. A complete criticality safety analysis and radiation shielding analysis, including validation and contingency and accident analysis must be completed by licensed and authorized personnel before any transfer or storage of MARVEL reactor nuclear fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Athena-I CUBIT Journal Files

The Monte Carlo N-Particle (MCNP)1 transport code version 6 (also known as MCNP6) has the capability for tracking particles on unstructured mesh (UM) geometry models embedded into con structive solid geometry (CSG) cells. This feature has been developed for performing calculations of complex geometry models because manually creating CSG models is a time-consuming and error prone process as the complexities of geometries increase. The UM capability was originally designed to work with UM models created with the Abaqus software and ASCII input files that it generates. The MCNP code version 6.0 and later can process UM models formatted as Abaqus input files. Starting with version 6.3, MCNP can also process HDF5 mesh input files. External codes must be used to generate Abaqus input files for MCNP UM calculations. CUBIT, the Sandia National Laboratory automated mesh generation toolkit, can generate a UM model formatted as an Abaqus input file. However, the Abaqus input files exported from CUBIT cannot be used for MCNP simulations because it lacks the proper syntax. A Python script was developed to convert an Abaqus file created by CUBIT to an Abaqus file format that MCNP can process. Creating UM models for complex geometries is not an easy task. The process of creating UM models in CUBIT for MCNP simulations is detailed in. CUBIT provides several user interface options including a graphical user interface (GUI) and a command line interface. A GUI provides an easy way to use CUBIT without learning the CUBIT command syntax. When using CUBIT with either interface option, command lines are written into an ASCII file known as a journal file; this journal file can be edited and archived so that it can be played back in CUBIT to automatically generate a UM model. This report describes the CUBIT journal files of the UM models developed for Athena-I. The Athena platform, an energy-tuning assembly, was developed to spectrally shape the National Ignition Facility (NIF) deuterium-tritium fusion neutron source to a thermonuclear (fusion) plus prompt fission neutron spectrum with capability to act as a short-pulse neutron source. MCNP6 was used for the Athena experiment design analysis.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Parametric Study of 239 Pu and 235 U Mass Equivalency in Spherical Geometries

In this technical document, parametric studies were performed to determine if a bounding mass equivalency can be used to simplify multi-material models in MCNP6 for criticality evaluations. The studies explored the simplification of MCNP6 models by substituting materials, particularly 239 Pu for 235 U. The initial hypothesis for the material simplification is based on the subcritical mass limits from the ANSI/ANS- 8.1 standard which states that for water reflected metal spheres the limits are 20.1 kg 235 U and 5.0 kg 239 Pu. Using those masses, it was hypothesized that a 20.1 kg sphere of 235 U and a 5.0 kg sphere of 239 Pu could be considered to have the same multiplication. Given that equivalency, 4kg 235 U could be modeled by 1kg 239 Pu (i.e., a mass ratio of 4:1). The parametric studies compare the materials 239 Pu and 235 U independently and in multi-material spherical models. Critical mass, critical thickness, critical mass ratio and critical thickness ratio values are presented as functions of inner radius. keff values are presented as a function of inner radius at different mass ratios and total masses. Results indicate that the conservative bounding mass equivalency is one. That is, if substituting 239 Pu for 235 U it should be done on a gram for gram basis.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗