Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MASS SPECTRA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

A comb-sampling method for enhanced mass analysis in linear electrostatic ion traps

In this paper an algorithm for extracting spectral information from signals containing a series of narrow periodic impulses is presented. Such signals can typically be acquired by pickup detectors from the image-charge of ion bunches oscillating in a linear electrostatic ion trap, where frequency analysis provides a scheme for high-resolution mass spectrometry. To provide an improved technique for such frequency analysis, we introduce the CHIMERA algorithm (Comb-sampling for High-resolution IMpulse-train frequency ExtRAaction). This algorithm utilizes a comb function to generate frequency coefficients, rather than using sinusoids via a Fourier transform, since the comb provides a superior match to the data. This new technique is developed theoretically, applied to synthetic data, and then used to perform high resolution mass spectrometry on real data from an ion trap. If the ions are generated at a localized point in time and space, and the data is simultaneously acquired with multiple pickup rings, the method is shown to be a significant improvement on Fourier analysis. The mass spectra generated typically have an order of magnitude higher resolution compared with that obtained from fundamental Fourier frequencies, and are absent of large contributions from harmonic frequency components.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nitrogen-Activated Oxidation in Nitrogen Direct Analysis in Real Time Mass Spectrometry (DART-MS) and Rapid Detection of Explosives Using Thermal Desorption DART-MS

Direct analysis in real time mass spectrometry (DART-MS) was used to analyze an array of explosives including nitro-based explosives, peroxide explosives, and energetic heterocyclic compounds with different DART discharge gases (helium, argon, and nitrogen). Profound analyte oxidation was observed for particular compounds (TNT (9) and 2, 4-DNT (10)), whose mass spectra were completely dominated by the oxidation products when nitrogen was substituted for helium in DART analysis. This interesting phenomenon suggested that a highly oxidative environment provided by N{sub 2} DART ion source. A possible mechanism involved in nitrogen DART was proposed which may help further understanding the different chemistry involved in the ionization process. This work also presents a thermal desorption DART (TD-DART) configuration that can enable rapid, specific analysis of explosives from swipes. The screening of swipes with three different compositions (fiberglass, Hybond N{sup +} membrane, and filter paper) showed that fiberglass swipe has the best performance which was then used for the subsequent TD-DART analysis. A direct comparison of TD-DART with traditional DART demonstrated that TD-DART indeed gives better response than traditional DART (provided that the distance between the DART source and mass spectrometer is the same) and will have wider applications than traditional DART. .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

First observation of γ γ → p p ¯ K + K - and search for exotic baryons in p K systems

The process γ γ → p p ¯ K + K - and its intermediate processes are measured for the first time using a 980 fb - 1 data sample collected with the Belle detector at the KEKB asymmetric-energy e + e - collider. The production of p p ¯ K + K - and a Λ ( 1520 ) 0 ( Λ ¯ ( 1520 ) 0 ) signal in the p K - ( p ¯ K + ) invariant mass spectrum are clearly observed. However, no evidence for an exotic baryon near 1540 MeV / c 2 , denoted as Θ ( 1540 ) 0 ( Θ ¯ ( 1540 ) 0 ) or Θ ( 1540 ) + + ( Θ ( 1540 ) - -- ), is seen in the p K - ( p ¯ K + ) or p K + ( p ¯ K - ) invariant mass spectra. Cross sections for γ γ → p p ¯ K + K - , Λ ( 1520 ) 0 p ¯ K + + c . c . and the products σ ( γ γ → Θ ( 1540 ) 0 p ¯ K + + c . c . ) B ( Θ ( 1540 ) 0 → p K - ) and σ ( γ γ → Θ ( 1540 ) + + p ¯ K - + c . c . ) B ( Θ ( 1540 ) + + → p K + ) are measured. We also determine upper limits on the products of the χ c 0 and χ c 2 two-photon decay widths and their branching fractions to p p ¯ K + K - at the 90% credibility level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Atomic-scale characterization of germanium isotopic multilayers by atom probe tomography

We report comparison of the interfacial sharpness characterization of germanium (Ge) isotopic multilayers between laser-assisted atom probe tomography (APT) and secondary ion mass spectrometry (SIMS). An alternating stack of 8-nm-thick naturally available Ge layers and 8-nm-thick isotopically enriched {sup 70}Ge layers was prepared on a Ge(100) substrate by molecular beam epitaxy. The APT mass spectra consist of clearly resolved peaks of five stable Ge isotopes ({sup 70}Ge, {sup 72}Ge, {sup 73}Ge, {sup 74}Ge, and {sup 76}Ge). The degree of intermixing at the interfaces between adjacent layers was determined by APT to be around 0.8 {+-} 0.1 nm which was much sharper than that obtained by SIMS.

36 MATERIALS SCIENCE↗

Investigation of the Ionization Mechanism of NAD{sup +}/NADH-Modified Gold Electrodes in ToF-SIMS Analysis

Analysis of nicotinamide adenine dinucleotide (NAD{sup +}/NADH)-modified electrodes is important for in vitro monitoring of key biological processes. In this work, time-of-flight secondary ion mass spectrometry (ToF-SIMS) was used to analyze NAD{sup +}/NADH-modified gold electrodes. Interestingly, no obvious characteristic peaks of nicotinamide fragment could be observed in the mass spectra of NAD{sup +}/NADH in their neutral sodium pyrophosphate form. However, after acidification, the characteristic peaks for both NAD{sup +} and NADH were detected. This was due to the suppression effect of inner pyrophosphoric salts in both neutral molecules. Besides, it was proved that the suppression by inner salt was intramolecular. No obvious suppression was found between neighboring molecules. These results demonstrated the suppression effect of inner salts in ToF-SIMS analysis, providing useful evidence for the study of ToF-SIMS ionization mechanism of organic molecule-modified electrodes. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gas-phase fragmentation studies of cyclic oligo-β-(1→6)-D-glucosamines by electrospray ionization mass spectrometry using a hybrid high-resolution mass spectrometer

Positive and negative ion high-resolution electrospray ionization mass spectra (MS and MS{sub 2}) of cyclooligo-β-(1→6)-D-glucosamines and cyclooligo-β-(1→6)-N-acetyl-D-glucosamines were acquired and interpret. It was shown that the cleavages of glycosidic bonds are the main processes in the decay of protonated and metallated molecules. In addition, elimination of the water molecules (and ammonia for cyclooligo-β-(1→6)-D-glucosamines) was observed along with other processes including the unknown skeletal rearrangement. A primary fragmentation of the negatively charged ions (deprotonated molecules) differed from that of the positively charged ones.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Imaging photoelectron circular dichroism of chiral molecules by femtosecond multiphoton coincidence detection

Here, we provide a detailed account of novel experiments employing electron-ion coincidence imaging to discriminate chiral molecules. The full three-dimensional angular scattering distribution of electrons is measured after photoexcitation with either left or right circular polarized light. The experiment is performed using a simplified photoelectron-photoion coincidence imaging setup employing only a single particle imaging detector. Results are reported applying this technique to enantiomers of the chiral molecule camphor after three-photon ionization by circularly polarized femtosecond laser pulses at 400 nm and 380 nm. The electron-ion coincidence imaging provides the photoelectron spectrum of mass-selected ions that are observed in the time-of-flight mass spectra. The coincident photoelectron spectra of the parent camphor ion and the various fragment ions are the same, so it can be concluded that fragmentation of camphor happens after ionization. We discuss the forward-backward asymmetry in the photoelectron angular distribution which is expressed in Legendre polynomials with moments up to order six. Furthermore, we present a method, similar to one-photon electron circular dichroism, to quantify the strength of the chiral electron asymmetry in a single parameter. The circular dichroism in the photoelectron angular distribution of camphor is measured to be 8% at 400 nm. The electron circular dichroism using femtosecond multiphoton excitation is of opposite sign and about 60% larger than the electron dichroism observed before in near-threshold one-photon ionization with synchrotron excitation. We interpret our multiphoton ionization as being resonant at the two-photon level with the 3s and 3p Rydberg states of camphor. Theoretical calculations are presented that model the photoelectron angular distribution from a prealigned camphor molecule using density functional theory and continuum multiple scattering X alpha photoelectron scattering calculations. Qualitative agreement is observed between the experimental results and the theoretical calculations of the Legendre moments representing the angular distribution for the two enantiomers. The electron-ion coincidence technique using multiphoton ionization opens new directions in table-top analytical mass-spectrometric applications of mixtures of chiral molecules.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects of optical dopants and laser wavelength on atom probe tomography analyses of borosilicate glasses

Atom probe tomography (APT) is a novel analytical microscopy method that provides three dimensional elemental mapping with sub-nanometer spatial resolution and has only recently been applied to insulating glass and ceramic samples. In this paper, we have studied the influence of the optical absorption in glass samples on APT characterization by introducing different transition metal optical dopants to a model borosilicate nuclear waste glass (international simple glass). A systematic comparison is presented of the glass optical properties and the resulting APT data quality in terms of compositional accuracy and the mass spectra quality for two APT systems: one with a green laser (532 nm, LEAP 3000X HR) and one with a UV laser (355 nm, LEAP 4000X HR). These data were also compared to the study of a more complex borosilicate glass (SON68). The results show that the analysis data quality such as compositional accuracy and total ions collected, was clearly linked to optical absorption when using a green laser, while for the UV laser optical doping aided in improving data yield but did not have a significant effect on compositional accuracy. Comparisons of data between the LEAP systems suggest that the smaller laser spot size of the LEAP 4000X HR played a more critical role for optimum performance than the optical dopants themselves. The smaller spot size resulted in more accurate composition measurements due to a reduced background level independent of the material’s optical properties.

Environmental Molecular Sciences Laboratory↗

Characterization of Ce SUP 3+-tributyl phosphate coordination complexes produced by fused droplet electrospray ionization with a target capillary

Coordination complexes containing Ce(III) and tri-n-butyl phosphate (TBP) in the 1+, 2+ and 3+ charge states were generated using desorption electrospray ionization (DESI) mass spectrometry, in which the analyte solutions were supplied via a target capillary orthogonally situated with respect to the electrospray. Comparison with direct electrospray (ESI) showed that the same coordination complexes were produced in each experiment, and could be described by the general formula [Ce(NO3)m=0-2(TBP)n](3-m)+. This result indicates that DESI has utility for measuring metal speciation for metal ligand solutions where the gas-phase complexes generated by ESI have been correlated with solution speciation. Such an application would be useful for analyses where it is desirable to limit the total amount of metal being handled, or that have solvent systems that are not readily amenable to ESI. Both the direct ESI and DESI mass spectra showed similar trends with respect to the TBP:Ce ratio, viz. high values tend to favor formation of a larger fraction of the 1+ species, and the 2+ and 3+ species become relatively more important as the ratio is decreased. Within individual charge state ion envelopes, lower TBP:Ce ratios produce coordination complexes with fewer ligands, a trend also seen using both approaches. These trends again point toward strong similarity between the direct ESI and DESI analyses of the metal-ligand solutions. The DESI experiments were less sensitive for measuring the coordination complexes compared to the direct ESI experiments, by a factor of 10 - 100 depending on whether minimum detectable concentration or absolute ion abundances were considered. Nevertheless, mid-picomolar quantities of coordination complexes were measured using the target capillary, indicating that sensitivity would be sufficient for measuring species in many industrial separations processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Unexpected methyl migrations of ethanol dimer under synchrotron VUV radiation

While methyl transfer is well known to occur in the enzyme- and metal-catalyzed reactions, the methyl transfer in the metal-free organic molecules induced by the photon ionization has been less concerned. Herein, vacuum ultraviolet single photon ionization and dissociation of ethanol dimer are investigated with synchrotron radiation photoionization mass spectroscopy and theoretical methods. Besides the protonated clusters cation (C{sub 2}H{sub 5}OH) ⋅ H{sup +} (m/z = 47) and the β-carbon-carbon bond cleavage fragment CH{sub 2}O ⋅ (C{sub 2}H{sub 5}OH)H{sup +} (m/z = 77), the measured mass spectra revealed that a new fragment (C{sub 2}H{sub 5}OH) ⋅ (CH{sub 3}){sup +} (m/z = 61) appeared at the photon energy of 12.1 and 15.0 eV, where the neutral dimer could be vertically ionized to higher ionic state. Thereafter, the generated carbonium ions are followed by a Wagner-Meerwein rearrangement and then dissociate to produce this new fragment, which is considered to generate after surmounting a few barriers including intra- and inter-molecular methyl migrations by the aid of theoretical calculations. The appearance energy of this new fragment is measured as 11.55 ± 0.05 eV by scanning photoionization efficiency curve. While the signal intensity of fragment m/z = 61 starts to increase, the fragments m/z = 47 and 77 tend to slowly incline around 11.55 eV photon energy. This suggests that the additional fragment channels other than (C{sub 2}H{sub 5}OH) ⋅ H{sup +} and CH{sub 2}O ⋅ (C{sub 2}H{sub 5}OH)H{sup +} have also been opened, which consume some dimer cations. The present report provides a clear description of the photoionization and dissociation processes of the ethanol dimer in the range of the photon energy 12-15 eV.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Power of Many: An Ensemble Approach to Spectral Similarity

Quantifying the similarity between two mass spectra─a known reference mass spectrum and an unidentified sample mass spectrum─is at the heart of compound identification workflows in gas chromatography–mass spectrometry (GC-MS). The reference spectrum most like the sample is assigned as its identification (provided some quantitative similarity threshold is met, e.g., 80%) and thus accurately measuring similarity is essential. Significant research has gone toward developing metrics for this purpose, each of which has attempted to improve upon existing methods by incorporating GC-MS-specific information (e.g., peak ratios or retention times) or adopting various statistical and algorithmic frameworks. While this active development has led to a plethora of similarity metrics with demonstrated value across different contexts, the unfortunate consequence has been confusion surrounding which metric should be used as a global standard. No such metric is currently accepted as the standard method because different metrics have demonstrated optimal performance in different contexts. In this work, we propose an ensemble approach to spectral similarity scoring that combines the collective information from across existing similarity metrics to form an improved, globally representative similarity metric as a step toward establishing a global standard method. In conclusion, the resulting ensemble metrics are evaluated on over 88,000 spectra of varying complexity and demonstrate improved abilities to accurately rank the correct reference spectrum as the top-matching candidate for a sample relative to the rankings generated by individual similarity scores.

Carbohydrates↗

Ion mobility spectrometry of hydrazine, monomethylhydrazine, and ammonia in air with 5-nonanone reagent gas

Hydrazine (HZ) and monomethylhydrazine (MMH) in air were monitored continuously using a hand-held ion mobility spectrometer equipped with membrane inlet, 63Ni ion source, acetone reagent gas, and ambient temperature drift tube. Response characteristics included detection limit, 6 ppb; linear range, 10-600 ppb; saturated response, >2 ppm; and stable response after 15-30 min. Ammonia interfered in hydrazines detection through a product ion with the same drift time as that for MMH and HZ. Acetone reagent gas was replaced with 5-nonanone to alter drift times of product ions and separate ammonia from MMH and HZ. Patterns in mobility spectra, ion identifications from mass spectra, and fragmentation cross-sections from collisional-induced dissociations suggest that drift times are governed by ion-cluster equilibria in the drift region of the mobility spectrometer. Practical aspects including calibration, stability, and reproducibility are reported from the use of a hand-held mobility spectrometer on the space shuttle Atlantis during mission STS-37.

Flight Experiment↗

Microwave assisted transformation of N,N-diphenylamine as precursors of organic light emitting diodes (OLED)

In this research, study on the transformation of N,N-diphenylamine (DPA) using iodine (I2) utilizing solid state Microwave Assisted Organic Synthesis (MAOS) method has been carried out. The reaction was performed by variations of three parameters namely the mole of reagents, the amount and type of solid support (alumina/Al2O3), and the reaction conditions. Experimental results showed that neutral-alumina was a better solid support than basic-alumina. The optimum temperature for the reaction was approximately at 125-133 °C with reaction time of 15 minutes and microwave reactor power at 500-600 W. The separation of the yellowish green product solution with preparative Thin Layer Chromatography (TLC) method using n-hexane:ethyl acetate = 4:1 (v/v) as eluent yielded two fractions (I and II) and both fractions can undergo fluorescence under 365 nm UV light. Based on the LC chromatogram with methanol:water = 95:5 (v/v) as eluent and its corresponding mass spectra (ESI+), fraction I contained three compounds, which were tetracarbazole A, triphenylamine, and impurities in the form of plasticizer such as bis(2-ethylhexyl) phthalate. Fraction II also contained three compounds, which were tetracarbazole C, tetraphenylhydrazine, and plasticizer such as bis(2-ethylhexyl) phthalate. Both FT-IR (KBr disks) and NMR (500 MHz, CDCl{sub 3}) spectra of fraction I and II confirmed the aromatic amine groups in those compounds. The observed fluorescence colors of fraction I and II were violet and violet-blue, respectively. Based on their structures and fluorescence characters, the compounds in fraction I and II have the potential to be used as Organic Light Emitting Diode (OLED) compound precursors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dielectron production in Ar + KCl collisions at 1.76A GeV

We present results on dielectron production in {sup 40}Ar+KCl collisions at 1.76A GeV. For the first time {omega} mesons could be reconstructed in a heavy-ion reaction at a bombarding energy which is well below the production threshold in free nucleon-nucleon collisions. The {omega} multiplicity has been extracted and compared to the yields of other particles, in particular of the {phi} meson. At intermediate e{sup +}e{sup -} invariant masses, we find a strong enhancement of the pair yield over a reference spectrum from elementary nucleon-nucleon reactions, suggesting the onset of nontrivial effects of the nuclear medium. Transverse-mass spectra and angular distributions have been reconstructed in three invariant mass bins. In the former unexpectedly large slopes are found for high-mass pairs. The latter, in particular the helicity-angle distributions, are largely consistent with expectations for a pair cocktail dominated at intermediate masses by {Delta} Dalitz decays.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Data acquisition techniques for exploiting the uniqueness of the time-of-flight mass spectrometer: Application to sampling pulsed gas systems

Mass spectra are produced in most mass spectrometers by sweeping some parameter within the instrument as the sampled gases flow into the ion source. It is evident that any fluctuation in the gas during the sweep (mass scan) of the instrument causes the output spectrum to be skewed in its mass peak intensities. The time of flight mass spectrometer (TOFMS) with its fast, repetitive mode of operation produces spectra without skewing or varying instrument parameters and because all ion species are ejected from the ion source simultaneously, the spectra are inherently not skewed despite rapidly changing gas pressure or composition in the source. Methods of exploiting this feature by utilizing fast digital data acquisition systems, such as transient recorders and signal averagers which are commercially available are described. Applications of this technique are presented including TOFMS sampling of vapors produced by both pulsed and continuous laser heating of materials.

Lincoln, K. A.↗

Search for new non-resonant phenomena in high-mass dilepton final states with the ATLAS detector

A search for new physics with non-resonant signals in dielectron and dimuon final states in the mass range above 2 TeV is presented. This is the first search for non-resonant signals in dilepton final states at the LHC to use a background estimate from the data. The data, corresponding to an integrated luminosity of 139 fb –1 , were recorded by the ATLAS experiment in proton-proton collisions at a center-of-mass energy of √s = 13 TeV during Run 2 of the Large Hadron Collider. The benchmark signal signature is a two-quark and two-lepton contact interaction, which would enhance the dilepton event rate at the TeV mass scale. To model the contribution from background processes a functional form is fit to the dilepton invariant-mass spectra in data in a mass region below the region of interest. It is then extrapolated to a high-mass signal region to obtain the expected background there. No significant deviation from the expected background is observed in the data. Upper limits at 95% CL on the number of events and the visible cross-section times branching fraction for processes involving new physics are provided. Observed (expected) 95% CL lower limits on the contact interaction energy scale reach 35.8 (37.6) TeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Autonomous Metabolomics for Rapid Metabolite Identification in Global Profiling

An autonomous metabolomic workflow combining mass spectrometry analysis with tandem mass spectrometry data acquisition was designed to allow for simultaneous data processing and metabolite characterization. Although previously tandem mass spectrometry data have been generated on the fly, the experiments described herein combine this technology with the bioinformatic resources of XCMS and METLIN. We can analyze large profiling datasets and simultaneously obtain structural identifications, as a result of this unique integration. Furthermore, validation of the workflow on bacterial samples allowed the profiling on the order of a thousand metabolite features with simultaneous tandem mass spectra data acquisition. The tandem mass spectrometry data acquisition enabled automatic search and matching against the METLIN tandem mass spectrometry database, shortening the current workflow from days to hours. Overall, the autonomous approach to untargeted metabolomics provides an efficient means of metabolomic profiling, and will ultimately allow the more rapid integration of comparative analyses, metabolite identification, and data analysis at a systems biology level.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spectra and mean multiplicities of $π^-$ in central 40 Ar+ 45 Sc collisions at 13A, 19A, 30A, 40A, 75A and 150A Ge V / c beam momenta measured by the NA61/SHINE spectrometer at the CERN SPS

The physics goal of the strong interaction program of the NA61/SHINE experiment at the CERN Super Proton Synchrotron (SPS) is to study the phase diagram of hadronic matter by a scan of particle production in collisions of nuclei with various sizes at a set of energies covering the SPS energy range. This paper presents differential inclusive spectra of transverse momentum, transverse mass and rapidity of π - mesons produced in central 40 Ar+ 45 Sc collisions at beam momenta of 13A, 19A, 30A, 40A, 75A and 150A Ge V /c. Energy and system size dependence of parameters of these distributions – mean transverse mass, the inverse slope parameter of transverse mass spectra, width of the rapidity distribution and mean multiplicity – are presented and discussed. Furthermore, the dependence of the ratio of the mean number of produced pions to the mean number of wounded nucleons on the collision energy was derived. The results are compared to predictions of several models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗