Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MASS RESOLUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Performance of the Dragonfly Mass Spectrometer (DraMS) Programmable UV Laser Source Engineering Test Unit (ETU)

NASA’s Dragonfly mission will sample surface materials from multiple sites on Saturn’s largest moon, Titan, in exploration of its potential for prebiotic chemistry. We report on the performance of our short-pulsed UV laser transmitter, developed for the Dragonfly’s on-board Mass Spectrometer (DraMS). Our engineering test unit (ETU) has completed flight qualification and demonstrated its operational science requirements, such that the final flight unit build can begin. The Titan Hydrocarbon Analysis Nanosecond Optical Source (THANOS) ETU laser produces 266 nm laser pulses at programmable energy levels in order to create high resolution laser desorption mass spectrometry (LDMS) measurements. The laser operates in short bursts of 1-50 pulses, each at < 2 ns pulse width, at a 100 Hz repetition rate. Creating a sealed Titanium unit, capable of operation on the extreme environment of Titan’s surface was a major engineering challenge. The laser successfully demonstrated its ability to meet all operational requirements in terms of pulse energy, beam pointing on target and repeatability even after extensive environmental testing.

Matthew W Mullin↗

Performance of the Dragonfly Mass Spectrometer (DraMS) Programmable UV Laser Source Engineering Test Unit (ETU)

NASA’s Dragonfly mission will sample surface materials from multiple sites on Saturn’s largest moon, Titan, in exploration of its potential for prebiotic chemistry. We report on the performance of our short-pulsed UV laser transmitter, developed for the Dragonfly’s on-board Mass Spectrometer (DraMS). Our engineering test unit (ETU) has completed flight qualification and demonstrated its operational science requirements, such that the final flight unit build can begin. The Titan Hydrocarbon Analysis Nanosecond Optical Source (THANOS) ETU laser produces 266 nm laser pulses at programmable energy levels in order to create high resolution laser desorption mass spectrometry (LDMS) measurements. The laser operates in short bursts of 1-50 pulses, each at < 2 ns pulse width, at a 100 Hz repetition rate. Creating a sealed Titanium unit, capable of operation on the extreme environment of Titan’s surface was a major engineering challenge. The laser successfully demonstrated its ability to meet all operational requirements in terms of pulse energy, beam pointing on target and repeatability even after extensive environmental testing.

Matthew Mullin↗

Measuring Greenland Ice Mass Variation With Gravity Recovery and the Climate Experiment Gravity and GPS

The response of the Greenland ice sheet to climate change could significantly alter sea level. The ice sheet was much thicker at the last glacial maximum. To gain insight into the global change process and the future trend, it is important to evaluate the ice mass variation as a function of time and space. The Gravity Recovery and Climate Experiment (GRACE) mission to fly in 2001 for 5 years will measure gravity changes associated with the current ice variation and the solid earth's response to past variations. Our objective is to assess the separability of different change sources, accuracy and resolution in the mass variation determination by the new gravity data and possible Global Positioning System (GPS) bedrock uplift measurements. We use a reference parameter state that follows a dynamic ice model for current mass variation and a variant of the Tushingham and Peltier ICE-3G deglaciation model for historical deglaciation. The current linear trend is also assumed to have started 5 kyr ago. The Earth model is fixed as preliminary reference Earth model (PREM) with four viscoelastic layers. A discrete Bayesian inverse algorithm is developed employing an isotropic Gaussian a priori covariance function over the ice sheet and time. We use data noise predicted by the University of Texas and JPL for major GRACE error sources. A 2 mm/yr uplift uncertainty is assumed for GPS occupation time of 5 years. We then carry out covariance analysis and inverse simulation using GRACE geoid coefficients up to degree 180 in conjunction with a number of GPS uplift rates. Present-day ice mass variation and historical deglaciation are solved simultaneously over 146 grids of roughly 110 km x 110 km and with 6 time increments of 3 kyr each, along with a common starting epoch of the current trend. For present-day ice thickness change, the covariance analysis using GRACE geoid data alone results in a root mean square (RMS) posterior root variance of 2.6 cm/yr, with fairly large a priori uncertainties in the parameters and a Gaussian correlation length of 350 km. Simulated inverse can successfully recover most features in the reference present-day change. The RMS difference between them over the grids is 2.8 cm/yr. The RMS difference becomes 1.1 cm/yr when both are averaged with a half Gaussian wavelength of 150 km. With a fixed Earth model, GRACE alone can separate the geoid signals due to past and current load fairly well. Shown are the reference geoid signatures of direct and elastic effects of the current trend, the viscoelastic effect of the same trend starting from 5 kyr ago, the Post Glacial Rebound (PGR), and the predicted GRACE geoid error. The difference between the reference and inverse modeled total viscoelastic signatures is also shown. Although past and current ice mass variations are allowed the same spatial scale, their geoid signals have different spatial patterns. GPS data can contribute to the ice mass determination as well. Additional information is contained in the original.

Wu, Xiao-Ping↗

Measurement of polycyclic aromatic hydrocarbon (PAHs) in interplanetary dust particles

We report here the first definitive measurements of specific organic molecules (polycyclic aromatic hydrocarbons (PAH's)) in interplanetary dust particles (IDP's). An improved version of the microbeam-two-step laser mass spectrometer was used for the analysis. Two IDP's gave similar mass spectra showing an abundance of PAH's. Control samples, including particles of probable terrestrial origin from the same stratospheric collector, gave either null results or quite different spectra. We conclude that the PAH's are probably indigenous to the IDP's and are not terrestrial contaminants. The instrument used to study the particles is a two-step laser mass spectrometer. Constituent neutral molecules of the sample are first desorbed with a pulsed infrared laser beam focussed to 40 micrometers. In the second step, PAH's in the desorbed plume are preferentially ionized by a pulsed UV laser beam. Resulting ions produced by resonant absorption are extracted into a reflectron time-of-flight mass spectrometer. This instrument has high spatial resolution, high ion transmission, unlimited mass range, and multichannel detection of all ion masses from a single laser shot.

Clemett, S. J.↗

Portable mass spectrometer

Eighteen-pound unit gives real-time onsite sample analysis. Mass range is twelve to two hundred atomic mass units with resolution of two hundred. Device has biomedical application possibilities, such as determination of alcohol and gas content of blood and breath.

Giffin, C. E.↗

Research in particles and fields

The astrophysical aspects of cosmic radiation and the radiation and electromagnetic field environment of the Earth and other planets are investigated. Energetic particle and photon detector systems flown on spacecraft and balloons are used. Galactic, solar, interplanetary, and planetary energetic particles and plasmas are also studied with emphasis on precision measurements with high resolution in charge, mass, and energy.

Vogt, R. E.↗

Research in particles and fields

Research activities in Cosmic Rays Gamma Rays, and Astrophysical Plasmas are covered The investigation of the astrophysical aspects of cosmic rays and gamma rays and of the radiation and electromagnetic field environment of the Earth and other planets are studied. These investigations are carried ut by means of energetic particle and photon detector systems flown on spacecraft and balloons. The emphasis is on precision measurements with high resolution in charge mass and energy. An extensive bibliography is given.

Stone, E. C.↗

Superconducting techniques for gravity survey and inertial navigation

A three-axis gravity gradiometer is developed, in which the magnetic fields produced by persistent currents are modulated by motions of superconducting proof masses. The common-acceleration-induced errors are compensated for by a six-axis superconducting accelerometer with a single magnetically levitated proof mass, linear acceleration resolution of 4 x 10 to the -12th m/(s exp 2 Hz exp 1/2), and angular acceleration resolution of 3 x 10 to the -11th rad/(s exp 2 Hz exp 1/2). The testing of a prototype gradiometer revealed that the environment-induced noise limits the noise floor to 7 x 10 to the -10th/(s exp 2 Hz exp 1/2).

Chan, H. A.↗

The Giotto ion mass spectrometer

The Giotto Ion Mass Spectrometer (IMS) consists of two sensors: one optimized for the outer and the other for the inner coma, with each obtaining complementary information in the region for which it is not optimized. The outer coma is characterized by the interaction between solar wind and comentary plasmas, the inner coma by the outflow of cometary neutrals and their ionization products. Both sensors feature mass imaging characteristics, permitting simultaneous measurements of several ion species by multidetector arrays. Resultant mass-per-charge resolution is greater than or = 20. Energy per charge, and the elevation and aximuth of incident ions are measured. Calibration and in-flight solar-wind data show that the IMS will meet its scientific goals for the Halley encounter.

Balsiger, H.↗

Research in particle and gamma-ray astrophysics

This research program is directed toward the investigation of the astrophysical aspects of cosmic rays and gamma rays and of the radiation and electromagnetic field environment of the Earth and other planets. The emphasis was on precice measurements with high resolution in charge, mass and energy. These investigations were carried out by means of energetic particle and photon detector systems flown on spacecraft and balloons.

Stone, E. C.↗

First results from the faint object camera - High-resolution observations of the central object R136 in the 30 Doradus nebula

R136 is the luminous central object of the giant H II region 30 Doradus in the LMC. The first high-resolution observations of R136 with the Faint Object Camera on board the Hubble Space Telescope are reported. The physical nature of the brightest component R136a has been a matter of some controversy over the last few years. The UV images obtained show that R136a is a very compact star cluster consisting of more than eight stars within 0.7 arcsec diameter. From these high-resolution images a mass upper limit can be derived for the most luminous stars observed in R136.

Weigelt, G.↗

A Low-cost, Lightweight, and Miniaturized Time-of-flight Mass Spectrometer (TOFMS)

Time-of-flight mass spectrometers (TOFMS) are commonly used for mass analysis and for the measurement of energy distributions of charged particles. For achieving high mass and energy resolution these instruments generally comprise long flight tubes, often as long as a few meters. This necessitates high voltages and a very clean environment. These requirements make them bulky and heavy. We have developed an instrument and calibration techniques that are based on the design principles of TOFMS. However, instead of one long flight tube it consists of a series of cylindrical electrostatic lenses that confine ions under study along the axis of the flight tube.

Srivastava, S. K.↗

Grazing Incidence Nickel Replicated Optics for Hard X-ray Telescopes

The requirements for future hard x-ray (up to 50 keV) telescopes are lightweight, high angular resolution optics with large collecting areas. Grazing incidence replicated optics are an excellent candidate for this, type of mission, providing better angular resolution, comparable area/unit mass, and simpler fabrication than multilayer-coated foils. Most importantly, the technology to fabricate the required optics currently exists. A comparison of several hard x-ray telescope designs will be presented.

Peturzzo, J. J., III↗

A Segmented Time-of-Flight Mass Spectrometer

The present paper describes the design of a time-of-flight mass spectrometer (TOFMS) in which the single flight tube of a conventional TOFMS has been replaced by several cylindrical electrostatic lenses in tandem. By a judicious choice of voltages on these lenses, an improved TOFMS has been realized which has a superior mass and energy resolution, shorter flight lengths, excellent signal-to-noise ratio and less stringent requirements on the bias voltages.

Srivastava, S. K.↗

The Constellation-X Spectroscopy X-Ray Telescope

The status of technology development for the Constellation-X Spectroscopy X-ray Telescope (SXT) mirror is presented. The SXT mirror combines a large (1.6 m) aperture with modest (12 arc sec half power diameter) angular resolution and low mass (750 kg). The overall collecting area, larger than 9,600 square cm at 0.25 keV, requires high throughput, and thus nesting of a substantial number of thin reflectors. A phased development program is underway to develop reflectors, mounting and alignment approaches, and metrology techniques for components and the mirror has a whole. The latest results in all these areas are summarized, along with an overview of results of optical testing of reflector performance.

Petre, Robert↗

Remote sensing of convective clouds with Microwave Limb Sounder

Deep convection lifts up many large ice particles to the upper troposphere where they can be detected with microwave sensors from space, using limb-viewing techniques. Microwave Limb Sounder (MLS) has unique advantages in measuring these high clouds and their ice mass with vertical resolution.

Microwave Limb Sounder↗

Compact Microwave Fourier Spectrum Analyzer

A compact photonic microwave Fourier spectrum analyzer [a Fourier-transform microwave spectrometer, (FTMWS)] with no moving parts has been proposed for use in remote sensing of weak, natural microwave emissions from the surfaces and atmospheres of planets to enable remote analysis and determination of chemical composition and abundances of critical molecular constituents in space. The instrument is based on a Bessel beam (light modes with non-zero angular momenta) fiber-optic elements. It features low power consumption, low mass, and high resolution, without a need for any cryogenics, beyond what is achievable by the current state-of-the-art in space instruments. The instrument can also be used in a wide-band scatterometer mode in active radar systems.

Savchenkov, Anatoliy↗

STEPS: JPL's Astrometric Exoplanet Survey

Presentation topics include: STEPS ground-based astrometry at Hale Telescope; the instrument; why astronomy and why M-dwarfs; motion of center of light about center of mass in photocentric orbit; photocentric motion vs. fractional mass; high-resolution imaging of STEPS targets; GU 802 p one possible orbit plotted with data, Keplerian frame; GJ 802 results; STEPS future; and a bibliography of STEPS papers.

astrometry↗