Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETOMETERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Parallel high-frequency magnetic sensing with an array of flux transformers and multi-channel optically pumped magnetometer for hand MRI application

Here, we investigate an approach for parallel high-frequency magnetic sensing based on a multi-channel radio frequency (RF) optically pumped magnetometer (OPM) coupled to multiple flux transformers (FTs) with a focus on hand magnetic resonance imaging (MRI) application at ultra-low field (ULF). Multiple RF OPM sensing channels are realized by using a single large-area alkali-metal vapor cell and two laser beams for pumping and probing, shared for all the channels. This design leads to significant cost reduction when multi-channel sensing is desirable, as in the case of ULF MRI. The FT, composed of two connected coils, serves as a transmitter of a target magnetic field to the OPM, while decoupling the OPM from untargeted magnetic fields in the sensing area that can limit the OPM performance. For hand MRI application, theoretical and numerical analysis is performed to determine an optimal geometry for the FT array that could improve signal-to-noise ratio (SNR) and sufficiently reduce crosstalk between FTs. We estimate that the optimized multi-channel FT-OPM sensor can achieve a magnetic field sensitivity of the order of 1 fT / Hz 1 / 2 above 100 kHz, which would be sufficient for 1 mm resolution MRI. In general, the multi-channel capability enables simultaneous magnetic measurements, thus reducing the sensing time and improving the SNR, and we anticipate many applications of the multi-channel FT-OPM sensor beyond the targeted here hand MRI: anatomical parallel ULF MRI of the human brain and other parts of the body, airport security screening, magnetic material imaging, and many others.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental Constraint on an Exotic Spin- and Velocity-Dependent Interaction in the Sub-meV Range of Axion Mass with a Spin-Exchange Relaxation-Free Magnetometer

Here, we conducted a search for an exotic spin- and velocity-dependent interaction for polarized electrons with an experimental approach based on a high-sensitivity spin-exchange relaxation-free (SERF) magnetometer, which serves as both a source of polarized electrons and a magnetic-field sensor. The experiment aims to sensitively detect magnetic-fieldlike effects from the exotic interaction between the polarized electrons in a SERF vapor cell and unpolarized nucleons of a closely located solid-state mass. We report experimental results on the interaction with 82 h of data averaging, which sets an experimental limit on the coupling strength around 10 –19 for the axion mass m a ≲ 10 –3 eV, within the important axion window.

74 ATOMIC AND MOLECULAR PHYSICS↗

Four-channel optically pumped atomic magnetometer for magnetoencephalography

We have developed a four-channel optically pumped atomic magnetometer for magnetoencephalography (MEG) that incorporates a passive diffractive optical element (DOE). The DOE allows us to achieve a long, 18-mm gradiometer baseline in a compact footprint on the head. Using gradiometry, the sensitivities of the channels are < 5 fT/Hz 1/2 , and the 3-dB bandwidths are approximately 90 Hz, which are both sufficient to perform MEG. Additionally, the channels are highly uniform, which offers the possibility of employing standard MEG post-processing techniques. As a result, this module will serve as a building block of an array for magnetic source localization.

47 OTHER INSTRUMENTATION↗

Four-channel optically pumped magnetometer for a magnetoencephalography sensor array

We present a novel four-channel optically pumped magnetometer (OPM) for magnetoencephalography that utilizes a two-color pump/probe scheme on a single optical axis. We characterize its performance across 18 built sensor modules. The new sensor implements several improvements over our previously developed sensor including lower vapor-cell operating temperature, improved probe-light detection optics, and reduced optical power requirements. The sensor also has new electromagnetic field coils on the sensor head which are designed using stream-function-based current optimization. We detail the coil design methodology and present experimental characterization of the coil performance. The magnetic sensitivity of the sensor is on average 12.3 fT/rt-Hz across the 18 modules while the average gradiometrically inferred sensitivity is about 6.0 fT/rt-Hz. The sensor 3-dB bandwidth is 100 Hz on average. The on-sensor coil performance is in good agreement with the simulations.

Iivanainen, Joonas (ORCID:0000000160344604)↗

Designing a User Interface for Real-Time Magnetometer Data Acquisition

The Matter-wave Atomic Gradiometer Interferometric Sensor (MAGIS-100) is a next-generation quantum sensor designed to search for ultralight dark matter and explore new frontiers in quantum mechanics. Due to the experiment s sensitivity to magnetic interference, a magnetometer trolley system was developed to scan magnetic fields along a vacuum tube. Interacting with the system required command-line inputs, creating usability challenges. To improve accessibility and streamline data acquisition, I developed a graphical user interface (GUI) using Python and the customtkinter library. The GUI supports real-time data display, state/mode switching, command execution, and CSV file management. I collaborated with another intern to integrate data visualization features into the GUI, allowing users to generate 3D plots of post-acquisition magnetic field data. In the future, I aim to fix the real-time plotting feature as it results in an unresponsive GUI.

Mendez, Milagros [DuPage Coll.]↗

All-optical, Microwave-free NV-Diamond Magnetometer for Weak Magnetic Field Environments

Sensitive nitrogen-vacancy (NV) magnetometry typically requires a bias field to lift the spin level degeneracy and has commonly utilized microwave sources to selectively manipulate the sensor's spin state. However, this external bias field and microwave sources may perturb the sample of interest or be incompatible with operational conditions. Here, we demonstrate an all-optical, microwave-free NV-diamond magnetometer in the presence of weak or no bias magnetic field (<20 G). We experimentally measure photoluminescence spectra using diamonds with varying NV concentrations; and numerically simulate matching features due to cross-relaxation between NVs. Our results pave the way towards a sensitive probe to study magnetic systems that can be disrupted by microwave signals and can only tolerate weak bias magnetic field.

Ung, Kristine↗

All-optical, Microwave-free NV-Diamond Magnetometer for High Magnetic Field Environment

Nitrogen vacancy (NV) magnetometry has commonly utilized microwave sources to manipulate the sensor's spin state. However, this technique becomes technically challenging under an environment with a Tesla-scale magnetic field or extreme conditions that prohibit the usage of microwave. By leveraging the effect that an off-axis magnetic field to the NV axis quenches its emitted photoluminescence, we present an all-optical, microwave-free broadband quantum diamond magnetometer. We demonstrate magnetic sensing over an extended bias magnetic field range — beyond the ground-state level anti-crossing (GSLAC) region — with a more integrated design.

Zheng, Xiechen↗

High-Field Quantum Diamond Magnetometers for Fusion Diagnostics (Final Technical Report)

Summary of research performed to enable all-optical quantum diamond magnetometers for fusion diagnostics, including: the physical mechanisms enabling all-optical photoluminescence contrast as a function of magnetic field magnitude and direction for dense ensembles of nitrogen vacancy (NV) centers in diamond; the characterization and optimization of NV-diamond material; and related investigations and student training.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetometer measures orthogonal components of magnetic fields

Driven magnetometer accurately measures the components of a low strength magnetic field in each of three mutually perpendicular directions. To accomplish this, it employs the principle of magnetic resonance in optically pumped rubidium vapor.

Source record↗

Thermal motor positions magnetometer sensors

Reversing, thermal, motor-driven device positions magnetometer sensors for checking zero offset. The device alternately positions two sensors at fixed positions 90 degrees apart. The thermal motor is fabricated completely of nonmagnetic materials.

Kerwin, W. J.↗