Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Low Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Fast Characterization of Inducible Regions of Atrial Fibrillation Models With Multi-Fidelity Gaussian Process Classification

Computational models of atrial fibrillation have successfully been used to predict optimal ablation sites. A critical step to assess the effect of an ablation pattern is to pace the model from different, potentially random, locations to determine whether arrhythmias can be induced in the atria. In this work, we propose to use multi-fidelity Gaussian process classification on Riemannian manifolds to efficiently determine the regions in the atria where arrhythmias are inducible. We build a probabilistic classifier that operates directly on the atrial surface. We take advantage of lower resolution models to explore the atrial surface and combine seamlessly with high-resolution models to identify regions of inducibility. We test our methodology in 9 different cases, with different levels of fibrosis and ablation treatments, totalling 1,800 high resolution and 900 low resolution simulations of atrial fibrillation. When trained with 40 samples, our multi-fidelity classifier that combines low and high resolution models, shows a balanced accuracy that is, on average, 5.7% higher than a nearest neighbor classifier. We hope that this new technique will allow faster and more precise clinical applications of computational models for atrial fibrillation. All data and code accompanying this manuscript will be made publicly available at: https://github.com/fsahli/AtrialMFclass.

59 BASIC BIOLOGICAL SCIENCES↗

Radiation Hardened Engineered Substrates for Time and Space Resolution

Low Gain Avalanche Diodes (LGADs) have become sensors of choice for fast timing of minimum ionizing particles. The current generation of these devices suffer from only moderate radiation hardness, low fill factor, and limited design options. Cactus Materials Inc. proposes to develop sensors with gain layer implants buried beneath the surface which will, with AC coupling developed by Brookhaven National Laboratory (BNL) and University of California Santa Cruz (UC Santa Cruz) solve these problems. Fermilab has a major role in the CMS timing upgrade using the current generation of LGADs and development of AC-coupled, buried layer LGADs will solve some of the central problems inherent in this technology. Annex B included a two-year work plan, deliverables, schedule and funding for the project’s SBIR Phase II award to develop and test prototype LGADs utilizing wafer bonding technology and epitaxial growth, that will allow for fabrication of radiation hard AC coupled devices with 100% fill factor and adjustable operating point.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fabrication of Ultrasensitive Transition Edge Sensor Bolometric Detectors for HIRMES

The high resolution mid-infrared spectrometer (HIRMES) is a high resolving power (R approx. 100,000) instrument operating in the 25-122 micron spectral range and will fly on board the Stratospheric Observatory for Far-Infrared Astronomy (SOFIA) in 2019. Central ot HIRMES are its two transition edge sensor (TES) bolometric cameras, an 8x16 detector high resolution array and a 64x16 detector low resolution array. Both types of detectors consist of MoAu TES fabricated on leg-isolated Si membranes. Whereas the high resolution detectors, with noise equivalent power (NEP) approx. 2 aW/square root of (Hz), are fabricated on 0.45 micron Si substrates, the low resolution detectors, with NEP approx. 10 aW/square root of (Hz), are fabricated on 1.40 micron Si. Here we discuss the similarities and difference in the fabrication methodologies used to realize the two types of detectors.

Detectors↗

Super-resolution image display using diffractive decoders

High-resolution image projection over a large field of view (FOV) is hindered by the restricted space-bandwidth product (SBP) of wavefront modulators. We report a deep learning–enabled diffractive display based on a jointly trained pair of an electronic encoder and a diffractive decoder to synthesize/project super-resolved images using low-resolution wavefront modulators. The digital encoder rapidly preprocesses the high-resolution images so that their spatial information is encoded into low-resolution patterns, projected via a low SBP wavefront modulator. The diffractive decoder processes these low-resolution patterns using transmissive layers structured using deep learning to all-optically synthesize/project super-resolved images at its output FOV. This diffractive image display can achieve a super-resolution factor of ~4, increasing the SBP by ~16-fold. We experimentally validate its success using 3D-printed diffractive decoders that operate at the terahertz spectrum. This diffractive image decoder can be scaled to operate at visible wavelengths and used to design large SBP displays that are compact, low power, and computationally efficient.

36 MATERIALS SCIENCE↗

Strictly Enforcing Invertibility and Conservation in CNN-Based Super Resolution for Scientific Datasets

Abstract Recently, deep convolutional neural networks (CNNs) have revolutionized image “super resolution” (SR), dramatically outperforming past methods for enhancing image resolution. They could be a boon for the many scientific fields that involve imaging or any regularly gridded datasets: satellite remote sensing, radar meteorology, medical imaging, numerical modeling, and so on. Unfortunately, while SR-CNNs produce visually compelling results, they do not necessarily conserve physical quantities between their low-resolution inputs and high-resolution outputs when applied to scientific datasets. Here, a method for “downsampling enforcement” in SR-CNNs is proposed. A differentiable operator is derived that, when applied as the final transfer function of a CNN, ensures the high-resolution outputs exactly reproduce the low-resolution inputs under 2D-average downsampling while improving performance of the SR schemes. The method is demonstrated across seven modern CNN-based SR schemes on several benchmark image datasets, and applications to weather radar, satellite imager, and climate model data are shown. The approach improves training time and performance while ensuring physical consistency between the super-resolved and low-resolution data. Significance Statement Recent advancements in using deep learning to increase the resolution of images have substantial potential across the many scientific fields that use images and image-like data. Most image super-resolution research has focused on the visual quality of outputs, however, and is not necessarily well suited for use with scientific data where known physics constraints may need to be enforced. Here, we introduce a method to modify existing deep neural network architectures so that they strictly conserve physical quantities in the input field when “super resolving” scientific data and find that the method can improve performance across a wide range of datasets and neural networks. Integration of known physics and adherence to established physical constraints into deep neural networks will be a critical step before their potential can be fully realized in the physical sciences.

54 ENVIRONMENTAL SCIENCES↗

Palomar observations of the collision of comet Shoemaker-Levy 9 with Jupiter

We present two papers of the near-infrared observations from Palomar observatory of the impact of fragment R of comet Shoemaker-Levy 9 with Jupiter on July 21, 1994. The first paper is concerned with the lightcurves found from these observations: Two instruments were used to image the event at 3.2 and 4.5 microns simultaneously. The lightcurves from these image sequences both show two faint precursor flashes, a bright main peak, and several oscillations over the following hour. We identify the precursor flashes with the entry of the bolide into Jupiter's upper atmosphere, and with the post-impact ejecta plume rising above the planet's limb. The main peak is due to the re-entry of the collapsing plume in Jupiter's atmosphere and the resultant shock heating. The second paper is concerned with the low-resolution spectra from the lightcurves: Low-resolution 8-13 micron spectra taken near the peak of the lightcurve show a broad emission feature that resembles the delicate silicate feature commonly seen in comets and the interstellar medium. We use this feature to estimate the dust content of the impact plume. The overall infrared spectral energy distribution at the time of peak brightness is consistent with emission from an optically-thin layer of small particles at approximately 600 K. Integrating over the spectrum and the lightcurve, we obtain a total radiated energy from the R impact of greater than or equal to 10(exp 25) ergs and a plume mass of greater than or equal to 3 x 10(exp 13) g.

Neugebauer, G.↗

Model Resolution Sensitivity of the Simulation of North Atlantic Oscillation Teleconnections to Precipitation Extremes

We evaluate a high-resolution (0.25°), four-member ensemble simulation of the global climate (1979–2005) with the U.S. Department of Energy's Energy Exascale Earth System Model v0.3—forced with observed ocean surface temperatures and sea ice extent—for its ability to represent the North Atlantic Oscillation (NAO) teleconnections to winter precipitation extremes over western Europe. As compared to the low-resolution model (1°), it simulates a stronger impact of NAO on daily precipitation extremes over the western slopes of mountain ranges over southwestern Norway, northwestern United Kingdom, and the Western Balkan states. Precipitation extremes and their linear relationship with NAO are quantified using the generalized extreme value distribution. NAO-dependent large-scale (stratiform) precipitation intensity strengthens in the high-resolution model on seasonal time scales and plays a dominant role during simulated daily precipitation extremes. Improvements in the high-resolution model over these varied-topography regions largely appear to be due to finer resolved scales of motion that amplify NAO-dependent seasonal vertical moisture fluxes and enhance stable condensation. However, the high-resolution model simulates a weaker than observed impact of NAO on extratropical cyclone activity and total precipitable water, generally underperforming the low-resolution model These effects possibly offset the impact of enhanced vertical moisture fluxes on NAO-dependent precipitation extremes in the high-resolution model in these regions. Over the southwestern Iberian peninsula, the high-resolution model underperforms the low-resolution model simulating weaker than observed impact of NAO on precipitation extremes. Finally, this appears to be due to the reduction in total precipitable water despite an increase in NAO-dependent extratropical activity there.

54 ENVIRONMENTAL SCIENCES↗

Assessing Tropical Cyclones’ Contribution to Precipitation over the Eastern United States and Sensitivity to the Variable-Resolution Domain Extent

Tropical cyclones (TCs) can subject an area to heavy precipitation for many hours, or even days, worsening the risk of flooding, which creates dangerous conditions for residents of the U.S. East and Gulf Coasts. To study the representation of TC-related precipitation over the eastern United States in current-generation global climate models, a novel analysis methodology is developed to track TCs and extract their associated precipitation using an estimate of their dynamical outer size. This methodology is applied to three variable-resolution (VR) configurations of the Community Atmosphere Model, version 5 (CAM5), with high-resolution domains over the North Atlantic and one low-resolution conventional configuration, as well as to a combination of reanalysis and observational precipitation data. Metrics and diagnostics such as TC counts, intensities, outer storm sizes, and annual mean total and extreme precipitation are compared between the CAM5 simulations and reanalysis/observations. The high-resolution VR configurations outperform the global low-resolution configuration for all variables in the North Atlantic. Realistic TC intensities are produced by the VR configurations. The total North Atlantic TC counts are lower than observations but better than reanalysis.

54 ENVIRONMENTAL SCIENCES↗

GeMini: A High-Resolution, Low-Resource, Gamma-Ray Spectrometer for Planetary Science Applications

GeMini is a high-resolution gamma-ray spectrometer designed for planetary-science exploration. GeMini serves as the basis for instruments being flown on three upcoming deep-space missions: NASA’s mission to the M-class asteroid (16) Psyche, the Japan Aerospace Exploration Agency sample-return mission to the moons of Mars, and NASA’s Dragonfly mission that will land on Saturn’s largest moon, Titan. These science missions require high-resolution spectroscopy in a low-power, low-mass, rugged design that can survive in a variety of environments. GeMini addresses these needs by providing a cryogenically cooled crystal of high-purity germanium that can operate with as little as 10 to 20 watts, depending on the implementation and mission, and has a mass of less than 2 kg. GeMini helps determine the elemental composition of planetary bodies by measuring gamma rays emitted from the surface. This paper describes the mechanical, thermal, and electrical design of GeMini as well as its performance. Further, it describes testing that was performed to validate the design with respect to launch loads and radiation damage. Although the basic design of GeMini is common to all three missions, each planetary body has unique environmental conditions and mission specifications. This paper concludes by describing these upcoming missions and how GeMini is customized for each.

79 ASTRONOMY AND ASTROPHYSICS↗

Studies of the field-of-view resolution tradeoff in virtual-reality systems

Most virtual-reality systems use LCD-based displays that achieve a large field-of-view at the expense of resolution. A typical display will consist of approximately 86,000 pixels uniformly distributed over an 80-degree by 60-degree image. Thus, each pixel subtends about 13 minutes of arc at the retina; about the same as the resolvable features of the 20/200 line of a Snellen Eye Chart. The low resolution of LCD-based systems limits task performance in some applications. We have examined target-detection performance in a low-resolution virtual world. Our synthesized three-dimensional virtual worlds consisted of target objects that could be positioned at a fixed distance from the viewer, but at random azimuth and constrained elevation. A virtual world could be bounded by chromatic walls or by wire-frame, or it could be unbounded. Viewers scanned these worlds and indicated by appropriate gestures when they had detected the target object. By manipulating the viewer's field size and the chromatic and luminance contrast of annuli surrounding the field-of-view, we were able to assess the effect of field size on the detection of virtual objects in low-resolution synthetic worlds.

Piantanida, Thomas P.↗

Validation of Global Climatologies of Trace Gases Using NASA Global Tropospheric Experiment (GTE) Data

Methane is an important trace gas because it is a greenhouse gas that affects the oxidative capacity of the atmosphere. It is produced from biological and anthropogenic sources, and is increasing globally at a rate of approximately 0.6% per year [Climate Change 1992, IPCC]. By using National Oceanic and Atmospheric Administration/Climate Monitoring and Diagnostics Laboratory (NOAA/CMDL) ground station data, a global climatology of methane values was produced. Unfortunately, because the NOAA/CMDL ground stations are so sparse, the global climatology is low resolution. In order to compensate for this low resolution data, it was compared to in-situ flight data obtained from the NASA Global Tropospheric Experiment (GTE). The smoothed ground station data correlated well with the flight data. Thus, for the first time it is shown that the smoothing process used to make global contours of methane using the ground stations is a plausible way to approximate global atmospheric concentrations of the gas. These verified climatologies can be used for testing large-scale models of chemical production, destruction, and transport. This project develops the groundwork for further research in building global climatologies from sparse ground station data and studying the transport and distribution of trace gases.

Courchaine, Brian↗

Uncertainty analysis of wavelet-based feature extraction for isotope identification on NaI gamma-ray spectra

Low-resolution isotope identifiers are widely deployed for nuclear security purposes, but these detectors currently demonstrate problems in making correct identifications in many typical usage scenarios. While there are many hardware alternatives and improvements that can be made, performance on existing low resolution isotope identifiers should be able to be improved by developing new identification algorithms. We have developed a wavelet-based peak extraction algorithm and an implementation of a Bayesian classifier for automated peak-based identification. The peak extraction algorithm has been extended to compute uncertainties in the peak area calculations. To build empirical joint probability distributions of the peak areas and uncertainties, a large set of spectra were simulated in MCNP6 and processed with the wavelet-based feature extraction algorithm. Kernel density estimation was then used to create a new component of the likelihood function in the Bayesian classifier. Furthermore, identification performance is demonstrated on a variety of real low-resolution spectra, including Category I quantities of special nuclear material.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Deep machine learning-assisted multiphoton microscopy to reduce light exposure and expedite imaging

Two-photon excitation fluorescence (2PEF) allows imaging of tissue up to about one millimeter in thickness. Typically, reducing fluorescence excitation exposure reduces the quality of the image. However, using deep learning super resolution techniques, these low-resolution images can be converted to high-resolution images. This work explores improving human tissue imaging by applying deep learning to maximize image quality while reducing fluorescence excitation exposure. We analyze two methods: a method based on U-Net, and a patch-based regression method. Both methods are evaluated on a skin dataset and an eye dataset. The eye dataset includes 1200 paired high power and low power images of retinal organoids. The skin dataset contains multiple frames of each sample of human skin. High-resolution images were formed by averaging 70 frames for each sample and low-resolution images were formed by averaging the first 7 and 15 frames for each sample. The skin dataset includes 550 images for each of the resolution levels. We track two measures of performance for the two methods: mean squared error (MSE) and structural similarity index measure (SSIM). For the eye dataset, the patches method achieves an average MSE of 27,611 compared to 146,855 for the U-Net method, and an average SSIM of 0.636 compared to 0.607 for the U-Net method. For the skin dataset, the patches method achieves an average MSE of 3.768 compared to 4.032 for the U-Net method, and an average SSIM of 0.824 compared to 0.783 for the U-Net method. Despite better performance on image quality, the patches method is worse than the U-Net method when comparing the speed of prediction, taking 303 seconds to predict one image compared to less than one second for the U-Net method.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Estimation of trabecular bone parameters in children from multisequence MRI using texture-based regression

Purpose: This paper presents a statistical approach for the prediction of trabecular bone parameters from low-resolution multisequence magnetic resonance imaging (MRI) in children, thus addressing the limitations of high-resolution modalities such as HR-pQCT, including the significant exposure of young patients to radiation and the limited applicability of such modalities to peripheral bones in vivo. Methods: A statistical predictive model is constructed from a database of MRI and HR-pQCT datasets, to relate the low-resolution MRI appearance in the cancellous bone to the trabecular parameters extracted from the high-resolution images. The description of the MRI appearance is achieved between subjects by using a collection of feature descriptors, which describe the texture properties inside the cancellous bone, and which are invariant to the geometry and size of the trabecular areas. The predictive model is built by fitting to the training data a nonlinear partial least square regression between the input MRI features and the output trabecular parameters. Results: Detailed validation based on a sample of 96 datasets shows correlations >0.7 between the trabecular parameters predicted from low-resolution multisequence MRI based on the proposed statistical model and the values extracted from high-resolution HRp-QCT. Conclusions: The obtained results indicate the promise of the proposed predictive technique for the estimation of trabecular parameters in children from multisequence MRI, thus reducing the need for high-resolution radiation-based scans for a fragile population that is under development and growth.

60 APPLIED LIFE SCIENCES↗

Super Resolution of Remote Sensing Images Using Edge-Directed Radial Basis Functions

Edge-Directed Radial Basis Functions (EDRBF) are used to compute super resolution(SR) image from a given set of low resolution (LR) images differing in subpixel shifts. The algorithm is tested on remote sensing images and compared for accuracy with other well-known algorithms such as Iterative Back Projection (IBP), Maximum Likelihood (ML) algorithm, interpolation of scattered points using Nearest Neighbor (NN) and Inversed Distance Weighted (IDW) interpolation, and Radial Basis Functin(RBF) . The accuracy of SR depends on various factors besides the algorithm (i) number of subpixel shifted LR images (ii) accuracy with which the LR shifts are estimated by registration algorithms (iii) and the targeted spatial resolution of SR. In our studies, the accuracy of EDRBF is compared with other algorithms keeping these factors constant. The algorithm has two steps: i) registration of low resolution images and (ii) estimating the pixels in High Resolution (HR) grid using EDRBF. Experiments are conducted by simulating LR images from a input HR image with different sub-pixel shifts. The reconstructed SR image is compared with input HR image to measure the accuracy of the algorithm using sum of squared errors (SSE). The algorithm has outperformed all of the algorithms mentioned above. The algorithm is robust and is not overly sensitive to the registration inaccuracies.

Mareboyana, Manohar M.↗

SIEMENS ADVANCED QUANTRA FTICR MASS SPECTROMETER FOR ULTRA HIGH RESOLUTION AT LOW MASS

The Siemens Advanced Quantra Fourier Transform Ion Cyclotron Resonance (FTICR) mass spectrometer was evaluated as an alternative instrument to large double focusing mass spectrometers for gas analysis. High resolution mass spectrometers capable of resolving the common mass isomers of the hydrogen isotopes are used to provide data for accurate loading of reservoirs and to monitor separation of tritium, deuterium, and helium. Conventional double focusing magnetic sector instruments have a resolution that is limited to about 5000. The Siemens FTICR instrument achieves resolution beyond 400,000 and could possibly resolve the tritium ion from the helium-3 ion, which differ by the weight of an electron, 0.00549 amu. Working with Y-12 and LANL, SRNL requested Siemens to modify their commercial Quantra system for low mass analysis. To achieve the required performance, Siemens had to increase the available waveform operating frequency from 5 MHz to 40 MHz and completely redesign the control electronics and software. However, they were able to use the previous ion trap, magnet, passive pump, and piezo-electric pulsed inlet valve design. NNSA invested $1M in this project and acquired four systems, two for Y-12 and one each for SRNL and LANL. Siemens claimed a $10M investment in the Quantra systems. The new Siemens Advanced Quantra demonstrated phenomenal resolution in the low mass range. Resolution greater than 400,000 was achieved for mass 2. The new spectrometer had a useful working mass range to 500 Daltons. However, experiments found that a continuous single scan from low mass to high was not possible. Two useful working ranges were established covering masses 1 to 6 and masses 12 to 500 for our studies. A compromise performance condition enabled masses 1 to 45 to be surveyed. The instrument was found to have a dynamic range of about three orders of magnitude and quantitative analysis is expected to be limited to around 5 percent without using complex fitting algorithms. Analysis of low concentration ions, at the ppm level, required a separate analysis using ion ejection techniques. Chemical ionization due to the formation of the MH{sup +} ion or MD{sup +} increased the complexity of the spectra compared to magnetic sector mass spectra and formation of the protonated or deuterated complex was a dynamic function of the trap ion concentration. This made quantitative measurement more of a challenge. However, the resolution of the instrument was far superior to any other mass spectrometry technique that has been applied to the analysis of the hydrogen isotopes. The piezo-electric picoliter injection device offers a new way of submitting small quantities of atmospheric pressure sample gas for analysis. The new software had many improvements over the previous version but significant flaws in the beta codes remain that make the prototype units less than ideal. The instrument is a promising new technology that experience will likely improve. Unfortunately, Siemens has concluded that the technology will not be a commercial success and has decided to stop producing this product.

74 ATOMIC AND MOLECULAR PHYSICS↗

TH-EF-BRA-11: Feasibility of Super-Resolution Time-Resolved 4DMRI for Multi-Breath Volumetric Motion Simulation in Radiotherapy Planning

Purpose: To develop a novel super-resolution time-resolved 4DMRI technique to evaluate multi-breath, irregular and complex organ motion without respiratory surrogate for radiotherapy planning. Methods: The super-resolution time-resolved (TR) 4DMRI approach combines a series of low-resolution 3D cine MRI images acquired during free breathing (FB) with a high-resolution breath-hold (BH) 3DMRI via deformable image registration (DIR). Five volunteers participated in the study under an IRB-approved protocol. The 3D cine images with voxel size of 5×5×5 mm{sup 3} at two volumes per second (2Hz) were acquired coronally using a T1 fast field echo sequence, half-scan (0.8) acceleration, and SENSE (3) parallel imaging. Phase-encoding was set in the lateral direction to minimize motion artifacts. The BH image with voxel size of 2×2×2 mm{sup 3} was acquired using the same sequence within 10 seconds. A demons-based DIR program was employed to produce super-resolution 2Hz 4DMRI. Registration quality was visually assessed using difference images between TR 4DMRI and 3D cine and quantitatively assessed using average voxel correlation. The fidelity of the 3D cine images was assessed using a gel phantom and a 1D motion platform by comparing mobile and static images. Results: Owing to voxel intensity similarity using the same MRI scanning sequence, accurate DIR between FB and BH images is achieved. The voxel correlations between 3D cine and TR 4DMRI are greater than 0.92 in all cases and the difference images illustrate minimal residual error with little systematic patterns. The 3D cine images of the mobile gel phantom preserve object geometry with minimal scanning artifacts. Conclusion: The super-resolution time-resolved 4DMRI technique has been achieved via DIR, providing a potential solution for multi-breath motion assessment. Accurate DIR mapping has been achieved to map high-resolution BH images to low-resolution FB images, producing 2Hz volumetric high-resolution 4DMRI. Further validation and improvement are still required prior to clinical applications. This study is in part supported by the NIH (U54CA137788/U54CA132378).

60 APPLIED LIFE SCIENCES↗

Multiscale additive manufacturing of polymers using 3D photo-printable self-assembling ionic liquid monomers

3D photoprinting of a self-assembled ionic liquid (IL) monomer based liquid-crystalline mesophase introduces high-resolution nanoscale features (2–5 nm) into otherwise low-resolution (microscale features) polymer builds. A wide variety of geometric builds possessing internal hexagonal perforated lamellar (HPL) nanostructure containing ~2.4 nm diameter pores are fabricated by the digital light processing 3D printing of an aqueous mixture (61(w/w%)) of an ionic liquid monomer, 1-decyl-3-vinylimidazolium chloride, a co-monomer, polyethylene diacrylate (PEGDA, M n 575), and a visible light photo-initiator (eosin Y and triethanolamine). Vibrational spectroscopy and thermal analysis proves acrylate moiety polymerization occurs during printing but incomplete consumption of the IL vinyl groups. Post-printing exposure to UV light (λ 350 nm) completes vinyl polymerization serving to further improve nanostructure ordering as determined by SAXS. Solvent swelling (ethanol) induces a structural transformation to a body center cubic architecture accompanied by slight pore expansion (to 3.2 nm). The introduction of nanoscale features into low-resolution photo-printed polymers establishes a low-cost strategy for the additive manufacturing of multi-scale, structured nanoporous polymer membranes.

36 MATERIALS SCIENCE↗