Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Log data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

A preliminary study of the gas hydrate stability zone in a gas hydrate potential region of China

Abstract Due to its significance for gas hydrate accumulation, the gas hydrate stability zone (GHSZ) is an essential condition for successful gas hydrate exploration and is usually controlled by three main factors: gas components, geothermal gradient, and permafrost thickness. Based on the core and conventional log data of gas hydrate potential region, the CSMHYD program was adopted to simulate the influences of above three factors on the thickness of the GHSZ. When the gas components of the gas hydrate were CH 4 , C 2 H 6 , and C 3 H 8 , with the CH 4 percentage ranging from 50% to 100%, the average GHSZ thickness can reach 1000 m according to the forward simulation results. When the gas hydrate was composed of CH 4 and one of C 2 H 6 , C 3 H 8 , H 2 S, and CO 2 , the influence order of the above four gases on the thickness of GHSZ is as follows: H 2 S > C 2 H 6 > C 3 H 8 > CO 2 . Under the gas components of 90% CH 4 , 5% C 2 H 6, and 5% C 3 H 8 , the thickness of GHSZ decreased rapidly as the geothermal gradient increased following an exponential relation with a correlation of 99.92% and increased slowly as permafrost thickness increased following a linear relation with a correlation of 99.9%. In addition, the thickness of a gas hydrate favorable reservoir was determined by comprehensive log methods as 500 m. We conclude that a reservoir within 500 m below the permafrost layer is favorable for gas hydrate reservoir formation.

Xiao, Kun↗

Mountain-Top-to-Mountain-Top Optical Link Demonstration

A mountain-top-to-mountain-top optical communications demonstration was conducted between the JPL Table Mountain Facility (TMF), Wrightwood, California, and Strawberry Peak (SP), Lake Arrowhead, California, during the months of August and September of 2000. The link was nearly horizontal at an altitude of 2 km and spanned a range of 46.8 km. A 780-nm multibeam beacon broadcast from TMF was received by the JPL Optical Communications Demonstrator (OCD) located at SP. The received beacon was utilized as a pointing reference to retransmit an 852-nm communications laser beam, modulated at 400 Mb/s by a PN7 pseudo-random bit stream (PRBS) sequence. The long atmospheric path resulted in atmospheric-turbulence-induced angle-of-arrival fluctuations of the beacon at the OCD aperture. A .ne-steering control loop was used to track the resulting beacon centroid motion and update the pointing of the communications laser beam transmitted from SP to TMF. Fried parameters, or r0, inferred from focal spot sizes received at SP were 4 to 5 cm whereas, using the spot sizes received at TMF, they were 2 to 3 cm. In both cases, theory predicts larger r0 values. The predicted angle-of-arrival fluctuations compare well with measured rms displacements exhibited by the focal spots at either end of the link. An uncompensated error of ~1.1 rad in the x-axis and ~2 rad in the y-axis was obtained using centroid data logged by the OCD. Average bit-error rates of 10-5 were recorded for extended periods of time. An atmospheric coherence length r0 of 3 to 5 cm was inferred using the focal-plane spot size measured on the CCD tracking sensor and compared to a predicted value of 5 to 7 cm using reasonable atmospheric models. The irradiance bounds required for the CCD tracking sensor to perform centroiding was found to range from 2000 to 3000 integrated pixel counts, although a more reliable range was 600 to 3000, indicating a dynamic range of 6 to 11 dB. The motion of the spot on the focal plane was also recorded and yielded rms angle-of-arrival-induced focal-plane displacement of 9 to 11 m, compared to a predicted value of 7.8 to 11 m. The irradiance measurements made with the OCD clearly indicate that best tracking performance is obtained when the mean received signal is 2000 to 2200 counts. The best tracking performance resulted in an rms uncompensated error of 1.1 rad. The uncompensated error appeared to increase with either an increase or decrease in mean beacon-signal level. The rms uncompensated error determined by deriving the beacon displacement power spectral density from the beacon centroid-versustime data and the rejection function of the control loop yielded a higher value of 3.4 rad.

Biswas, A.↗

Method to account for natural fracture induced elastic anisotropy in geomechanical characterization of shale gas reservoirs

Shale has been usually recognized as a transverse isotropic (TI) medium in conventional geomechanical log interpretation due to its laminated nature. However, when natural fractures exist in the shale rock, additional elastic anisotropy is introduced, converting laminated Shale to an orthorhombic (OB) medium. Previous studies illustrate that neglecting the natural fracture induced anisotropy in shale geomechanical log interpretation could lead to inaccurate evaluations of elastic moduli and in-situ stresses. In this paper, a new method is developed to account for the natural fracture induced anisotropy in geomechanical log interpretation based upon the TI acoustic model developed by the author and a characterization technique of elastic wave anisotropy (Sayers, 1991). The new OB model incorporates the four acoustic log data inputs and five modeling constraints in a nonlinear optimization algorithm to solve for the nine independent stiffness coefficients of an OB rock, and further to solve for the geomechanical properties and in-situ stress profiles in an OB formation. The new method was validated with a Marcellus Gas Shale field case. Both the new OB model and the conventional TI model were applied to interpret the minimum horizontal stress profile for the same formation. By comparing the results, the OB model is more robust than the TI from two aspects. First, the average stress magnitude predicted by the OB model is closer to the one measured by the Diagnostic Fracture Injection Test (DFIT). Second, the OB model predicts a more obvious stress barrier between the lower Marcellus and upper Onondaga Limestone than the TI model does. Finally, the predicted stress barrier is consistent with the observation of the microseismic events of a horizontal well drilled and completed nearby, which reveals that no hydraulic fracture propagates downward through the bottom boundary of Marcellus Shale into the underlying Onondaga Limestone.

03 NATURAL GAS↗

Usage Pattern Analysis for the Summit Login Nodes

High performance computing (HPC) users interact with Summit through dedicated gateways, also known as login nodes. The performance and stability of these login nodes can have a significant impact on the user experience. In this study, the performance and stability of Summit’s five login nodes are evaluated by analyzing the log data from 2020 and 2021. The analysis focuses on the computing capability (CPU average load, users and tasks) and the storage performance, along with the associated job scheduler activity. The outcome of this study can serve as the foundation of a predictive modeling framework that enables the system admin of an HPC system to preemptively deploy countermeasures before the onset of a system failure.

Eiffert, Brett↗

Additive Manufacturing – A New Challenge for Automation and Robotics

Additive manufacturing (AM) is a rapidly growing technology descended from the first stereolithography systems. AM describes a variety of material deposition technologies for forming objects in a digital manner layer-by-layer under computer control. Now commonly known as 3D printing, AM quickly branched out into several key directions – material extrusion, sheet lamination, direct energy deposition, vat polymerization, powder bed fusion, binder jetting, and material jetting. The common factor in all AM branches is a foundation in robotics and automation. While most of the mechanical 3D printing structures are based on simple gantry systems, there are Gough-Stewart platforms and, more recently, six or more DoF manipulator-based systems that have been developed. Currently available commercial systems are based on open-loop control with minimum sensing capabilities; the latest systems in development are starting to take advantage of complex feedback loops and layers of advanced sensing and data logging. The Manufacturing Demonstration Facility of Oak Ridge National Laboratory is leading the efforts in applying advanced robotics in the creation of large-scale 3D printers. The recent demonstration of an additively manufactured excavator at the CONEXPO 2017 exhibition in Las Vegas showed that the use of cutting edge robotics and automation is essential for the next generation of additive systems. The future of AM will heavily rely on advanced robotics, machine learning, and the internet of things. This paper summarizes progress in AM; presents the practical aspects, challenges, and lessons learned in developing robotic-based AM systems; and outlines the needs and future directions of robotics for AM.

Nycz, Andrzej↗

Overall chilled water system energy consumption modeling and optimization

The emergence of increasingly affordable variable-speed drive technology has changed the approach used to control chilled water systems equipped with these drives. The purpose of this research was to develop an integrated chilled water modeling technique that can determine the optimal system setpoints and estimate the energy saving potential of chiller system. The chiller system equipped with Variable Frequency Drives (VFDs) on cooling tower fans and condenser water pumps. To accomplish the objective, physical component models of the centrifugal chiller, cooling tower and condenser water pump were established with the goal of incorporating the system’s condenser water flow rate and cooling tower fan speeds as optimization variables. Furthermore, a cooling load prediction algorithm was developed using a multiple non-linear regression model to approximate the building’s cooling load subject to a range of environmental conditions. The inputs and outputs of the individual component models were linked to estimate how adjusting the cooling tower fan and condenser water pump speed would influence the system’s comprehensive performance. Here, the overall system model was then optimized using a generalized reduced gradient optimization algorithm to determine the potential energy savings through speed control with VFDs and to ascertain a control logic strategy for the building automation system to operate the heating and cooling system. A case-study was performed on a single chiller system at a museum and the model was calibrated according to logged data collected over four months. Results showed that for the system analyzed, the energy saving of optimizing the cooling tower fan system was found to be 12–15%, while the energy saving potential of optimizing the condenser water pump with the cooling tower fan was negligible. Additionally, comparing different cooling tower fan control strategies showed that a wet-bulb approach-based cooling tower control strategy was shown to have the highest correlation to the optimized fan speed with an R 2 of 0.924.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Numerical simulations of depressurization-induced gas production from gas hydrates using 3-D heterogeneous models of L-Pad, Prudhoe Bay Unit, North Slope Alaska

Gas production potential is estimated using a three-dimensional reservoir model based on gas hydrate deposits located in the Prudhoe Bay region of the Alaska's North Slope. The model incorporates two hydrate-bearing sand units using detailed reservoir geological and structural information obtained from past and recent drilling programs. Geostatistical porosity models, conditioned to log data from 78 wells drilled in the vicinity of the Prudhoe Bay “L-Pad,” were developed, providing 3D heterogeneity in porosity, porosity-dependent hydrate saturation, and intrinsic permeability. The simulations utilize both vertical and inclined wellbores to induce depressurization of the reservoir at a constant bottom-hole pressure. The results show the superior performance of the inclined well design. Average gas production rates during the first five years were ~6.0 × 10 4 ST m 3 /day (~2.1 MMSCF/day) and ~2.7 × 10 4 ST m 3 /day (~1.0 MMSCF/day) for incline and vertical wells, respectively. After 30 years 5.3 × 10 8 - 5.7 × 10 8 ST m 3 (18.6–20.2 BSCF) and 6.2 × 10 8 - 6.4 × 10 8 ST m 3 (22.0–22.7 BSCF) gas were produced using the vertical and inclined well configurations, respectively. The analysis reveals that 2D reservoir models with homogeneous representations for porosity and hydrate saturation significantly underestimate production potential. The heterogeneity implemented in this work provides complex porous network and preferential pathways for mobile phase flow to a producing well. Consequently, no secondary hydrate formation around a wellbore is predicted in contrast to models that utilize uniform porosity and hydrate saturation distributions.

03 NATURAL GAS↗

Characterization of the mud displacement in an enlarged wellbore: An integrated rock-fluid model

Cement-mud displacement plays a crucial role in the sealability of cement sheaths. Irregular geometric features of a wellbore due to washout can have a negative impact on mud and cement mobilization. An unstable interface between two fluids always leads to mud channeling, interfluid mixing, and cement contamination, degrading the cement quality. Many factors, such as mechanical and rheological properties of fluids, annulus geometry, flow pattern, and flow rate, significantly influence the displacement efficiency. This study investigates the characterization of the mud displacement in an irregular horizontal well using a 3D computational fluid dynamics (CFD) model. Mud is displaced in an enlarged wellbore by geopolymer and neat class G cement. The wellbore geometry is developed based on the caliper log data from an unconventional shale well in the Tuscaloosa Marine Shale (TMS) lithology. The effects of pump rate, density difference, and mud contamination are evaluated by numerical simulations. The results present those residual muds mainly exist in the upper annulus of the enlarged section. Geopolymer has a better sealing performance and can resist more water-based mud (WBM) contaminations than neat class G cement. The scenario with a low mud-cement density difference and high cement injection rate results in a high cement volume fraction, mitigating the gas migration.

58 GEOSCIENCES↗

Assessing the potential of composite confining systems for secure and long-term CO 2 retention in geosequestration

A potential geologic target for CO 2 storage should ensure secure containment of injected CO 2 . Traditionally, this objective has been achieved by targeting reservoirs with overlying seals-regionally extensive, low permeability units that have been proven capable of retaining buoyant fluid accumulations over geologic time. However, considering that the amount of CO 2 is limited by a decadal injection period, vertical migration of CO 2 can be effectively halted by a composite system of discontinuous shale/silt/mudstone barriers in bedded sedimentary rocks. Here, we studied the impact of depositional architectures in a composite confining system on CO 2 migration and confinement at reservoir scale. We stochastically generated lithologically heterogeneous reservoir models containing discontinuous barriers consistent with statistical distributions of net-sand-to-gross-shale ratio (NTG) and horizontal correlation lengths derived from well log data and observations of producing hydrocarbon fields in Southern Louisiana. We then performed an extensive suite of reservoir simulations of CO 2 injection and post-injection to evaluate the sensitivity of CO 2 plume migration and pressure response of the composite system to a series of geologic and fluid parameters including the lateral continuity of barriers, NTG, permeability anisotropy within the sand body, and capillary pressure contrast between the sand and shale facies. The results indicate that lateral continuity of barriers and NTG are the dominant controls on CO 2 plume geometry and pressure build-up in the reservoir, while the impact of NTG is particularly pronounced. The significance of intraformational barriers becomes apparent as they facilitate the local capillary trapping of CO 2 . Those barriers improve the pore space occupancy by promoting a more dispersed shape of the plume and ultimately retard the buoyancy-driven upward migration of the plume post injection.

58 GEOSCIENCES↗

Direct sunlight facility for testing and research in HCPV

A facility for testing different components for HCPV application has been developed in the framework of 'Fotovoltaico ad Alta Efficienza' (FAE) project funded by the Sicilian Regional Authority (PO FESR Sicilia 2007/2013 4.1.1.1). The testing facility is equipped with an heliostat providing a wide solar beam inside the lab, an optical bench for mounting and aligning the HCPV components, electronic equipments to characterize the I-V curves of multijunction cells operated up to 2000 suns, a system to circulate a fluid in the heat sink at controlled temperature and flow-rate, a data logging system with sensors to measure temperatures in several locations and fluid pressures at the inlet and outlet of the heat sink, and a climatic chamber with large test volume to test assembled HCPV modules.

14 SOLAR ENERGY↗

A statistical method for estimating wood thermal diffusivity and probe geometry using in situ heat response curves from sap flow measurements

The heat pulse method is widely used to measure water flux through plants; it works by inferring the velocity of water through a porous medium from the speed at which a heat pulse is propagated through the system. No systematic, non-destructive calibration procedure exists to determine the site-specific parameters necessary for calculating sap velocity, e.g., wood thermal diffusivity and probe spacing. Such parameter calibration is crucial to obtain the correct transpiration flux density from the sap flow measurements at the plant scale; and consequently, to up-scale tree-level water fluxes to canopy and landscape scales. The purpose of this study is to present a statistical framework for estimating the wood thermal diffusivity and probe spacing simutaneously from in-situ heat response curves collected by the implanted probes of a heat ratio apparatus. Conditioned on the time traces of wood temperature following a heat pulse, the parameters are inferred using a Bayesian inversion technique, based on the Markov chain Monte Carlo sampling method. The primary advantage of the proposed methodology is that it does not require known probe spacing or any further intrusive sampling of sapwood. The Bayesian framework also enables direct quantification of uncertainty in estimated sap flow velocity. Experiments using synthetic data show that repeated tests using the same apparatus are essential to obtain reliable and accurate solutions. When applied to field conditions, these tests are conducted during different seasons and automated using the existing data logging system. The seasonality of wood thermal diffusivity is obtained as a by-product of the parameter estimation process, and it is shown to be affected by both moisture content and temperature. Empirical factors are often introduced to account for the influence of non-ideal probe geometry on the estimation of heat pulse velocity, and they are estimated in this study as well. The proposed methodology can be applied for the calibration of existing heat ratio sap flow systems at other sites. It is especially useful when an alternative transpiration calibration device, such as a lysimeter, is not available.

Bayesian inversion↗

Setting the threshold for high throughput detectors: A mathematical approach for ensembles of dynamic, heterogeneous, probabilistic anomaly detectors

Cyber operations now manage a high volume of heterogeneous log data. Anomaly Detection (AD) in such operations involves multiple (e.g., per IP, per data type) ensembles of detectors modeling heterogeneous characteristics (e.g., rate, size, type) often with adaptive online models producing alerts in near real time. Because of the high data volume, setting the threshold for each detector in such a system is an essential yet underdeveloped configuration issue that, if slightly mistuned, can leave the system useless, either producing a myriad of alerts (and flooding downstream systems) or giving none. In this work, we build on the foundations of Ferragut et al. to provide a set of rigorous results for understanding the relationship between threshold values and alert quantities for probabilistic detectors. This informs an algorithm for setting the threshold of multiple, heterogeneous, possibly dynamic detectors completely a priori, in principle. Indeed, if the underlying distribution of the incoming data is known, the algorithm provides provably manageable thresholds. If the distribution is unknown (poorly estimated), our analysis gives insight into how the model distribution differs from the actual distribution, indicating refitting is necessary. We provide empirical experiments, regulating the alert rate of a system with ≈2,500 adaptive detectors scoring over 1.5M events in 5 hours of timestamps. Further, we demonstrate on real network data and detection framework of Harshaw et al. the alternative case, demonstrating that the inability to regulate alerts indicates how the detection model is not a good fit to the data.

Bridges, Robert↗

Applying Graph Analytics to Understand Compute Core Usage and Publication Trends in a Petascale Supercomputing Facility

The Oak Ridge Leadership Computing Facility (OLCF) runs Titan, the No. 4 supercomputer in the world, to deliver over four billion compute core hours every year to several scientific domains, in their pursuit of leadership science. In this paper, we analyze four years worth of heterogeneous log data sources from the OLCF resource fabric, capturing metadata on entities such as users (2,546), scientific project allocations (674), jobs (1,352,402) and publications (1,146), to derive insights into the trends in core hour usage and publications, across 35 science domains. We have constructed a scalable graph to represent the OLCF entities and apply rich graph analytics for our analysis. Based on this, we have analyzed the metadata across five dimensions, namely (1) quantitative analysis of Titan system usage, (2) quantitative analysis of OLCF publications, (3) correlation analysis between system usage and publications, (4) text analysis to derive OLCF research trends, and (5) utilization of graph mining for association analysis. To the best of our knowledge, our work is the first of its kind to apply graph- based big data techniques to provide comprehensive insights on an HPC center's core hour usage and users' publication trends. Our results provide valuable details into an HPC center's core allocation program, measuring the productivity of scientific domains, the interplay between core usage and research output, accelerating collaboration, and in predicting new connections between resource entities.

Lee, Sangkeun (Matt)↗

Radiation testing of 2.4 micron wavelength extended InGaAs photodiodes for 100 MeV/n carbon ions

We have successfully tested simultaneously 2.4 Micron Wavelength, Extended InGaAs Photodiodes having diameters of 20, 30, 40, 50, 100, 150, 200, 250, and 290 Micron, coupled with a Single Mode Fiber using 100 MeV/n Carbon (C) Ions up to a cumulative dose of ~40 krad. During irradiation, the devices were maintained at dry ice temperature, reverse biased at 100 mV, and their leakage current was continuously monitored in-situ during the run. After the exposure was completed, all nine devices were monitored for any change in their leakage current at 100 mV and room temperature for several weeks to monitor any annealing effects that may occur. Nine Photodiodes with the above varying diameters were radiated with 100 MeV/n Carbon Ions with a fluence of 10 6 , 10 7 , 10 8 , 10 9 , and 10 10 ions/cm 2 at each fluence level. At 100 MeV/n the Linear Energy Transfer (LET) of Carbon Ion is ~0.156 MeV-cm 2 /mg in Extended InGaAs, which is an order magnitude more than Proton (H) and Helium (He) Ions of 100 MeV/n energy. Thus, significant displacement damage is anticipated in the Extended InGaAs Photodiode with 100 MeV/n Carbon Ions with a total fluence of 1 × 1010 ions/cm 2 . Pre- and Post- radiation results were also measured for: (1) Leakage Current Vs. Voltage for the Extended InGaAs Photodiodes; (2) Responsivity (Quantum Efficiency) in A/W for Photodiodes; and (3) Bandwidth of the Photodiodes. All devices were found to be fully functional at the normal operating conditions and at both dry ice and room temperature. The leakage current increased up to a factor of ~2X at lower bias of 100 mV at the highest fluence of 10 10 ions/cm 2 , but not significantly at higher bias of 2 V. Finally, we did not observe any post radiation annealing effect for leakage current at room temperature and 100 mV bias for any of the devices after several weeks of data logging.

2.4 micron wavelength↗

SU-E-T-400: Evaluation of Shielding and Activation at Two Pencil Beam Scanning Proton Facilities

Purpose: To verify acceptably low dose levels around two newly constructed identical pencil beam scanning proton therapy facilities and to evaluate accuracy of pre-construction shielding calculations. Methods: Dose measurements were taken at select points of interest using a WENDI-2 style wide-energy neutron detector. Measurements were compared to pre-construction shielding calculations. Radiation badges with neutron dose measurement capabilities were worn by personnel and also placed at points throughout the facilities. Seven neutron and gamma detectors were permanently installed throughout the facility, continuously logging data. Potential activation hazards have also been investigated. Dose rates near water tanks immediately after prolonged irradiation have been measured. Equipment inside the treatment room and accelerator vault has been surveyed and/or wipe tested. Air filters from air handling units, sticky mats placed outside of the accelerator vault, and water samples from the magnet cooling water loops have also been tested. Results: All radiation badges have been returned with readings below the reporting minimum. Measurements of mats, air filters, cooling water, wipe tests and surveys of equipment that has not been placed in the beam have all come back at background levels. All survey measurements show the analytical shielding calculations to be conservative by at least a factor of 2. No anomalous events have been identified by the building radiation monitoring system. Measurements of dose rates close to scanning water tanks have shown dose rates of approximately 10 mrem/hr with a half-life less than 5 minutes. Measurements around the accelerator show some areas with dose rates slightly higher than 10 mrem/hr. Conclusion: The shielding design is shown to be adequate. Measured dose rates are below those predicted by shielding calculations. Activation hazards are minimal except in certain very well defined areas within the accelerator vault and for objects placed directly in the path of the beam.

60 APPLIED LIFE SCIENCES↗

A Parallel Stochastic Framework for Reservoir Characterization and History Matching

The spatial distribution of parameters that characterize the subsurface is never known to any reasonable level of accuracy required to solve the governing PDEs of multiphase flow or species transport through porous media. This paper presents a numerically cheap, yet efficient, accurate and parallel framework to estimate reservoir parameters, for example, medium permeability, using sensor information from measurements of the solution variables such as phase pressures, phase concentrations, fluxes, and seismic and well log data. Numerical results are presented to demonstrate the method.

Thomas, Sunil G.↗

Replay-Stream

For testing and demonstration purposes, it is often necessary to replay saved network and log data. This library facilitates replaying these saved data streams. This module will take in a stream of JSON strings, read their specified timestamp field, and output according to the given criteria. This can include restricting output to a certain time range, and/or outputting the items with some delay based on their timestamp.

Goodall, John↗

Well Log ETL tool

This is an executable python script which offers two different conversions for well log data: 1) Conversion from a BoreholeLASLogData.xls model to a LAS version 2.0 formatted XML file. 2) Conversion from a LAS 2.0 formatted XML file to an entry in the WellLog Content Model. Example templates for BoreholeLASLogData.xls and WellLogsTemplate.xls can be found in the package after download.

Good, Jessica↗