Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LOADING RATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

An investigation of the thermoviscoplastic behavior of a metal matrix composite at elevated temperatures

This research investigates the response of a fiberless 13 layer hot isostatically pressed Ti-15-3 laminate to creep, constant strain rate, and cyclic constant strain rate loading at temperatures ranging from 482C to 649C. Creep stresses from 48 to 260 MPa and strain rates of .0001 to .01 m/m/sec were used. Material parameters for three unified constitutive models (Bodner-Partom, Miller, and Walker models) were determined for Ti-15-3 from the experimental data. Each of the three models was subsequently incorporated into a rule of mixtures and evaluated for accuracy and ease of use in predicting the thermoviscoplastic response of unidirectional metal matrix composite laminates (both 0 and 90). The laminates were comprised of a Ti-15-3 matrix with 29 volume percent SCS6 fibers. The predicted values were compared to experimentally determined creep and constant strain rate data. It was found that all three models predicted the viscoplastic response of the 0 specimens reasonably well, but seriously underestimated the viscoplastic response of the 90 specimens. It is believed that this discrepancy is due to compliant and/or weak fiber-matrix interphase. In general, it was found that of the three models studied, the Bodner-Partom model was easiest to implement, primarily because this model does not require the use of cyclic constant strain rate tests to determine the material parameters involved. However, the version of the Bodner-Partom model used in this study does not include back stress as an internal state variable, and hence may not be suitable for use with materials which exhibit a pronounced Baushinger effect. The back stress is accounted for in both the Walker and Miller models; determination of the material parameters associated with the Walker model was somewhat easier than in the Miller model.

Rogacki, John R.↗

Zero-Gravity Locomotion Simulators: New Ground-Based Analogs for Microgravity Exercise Simulation

Maintaining health and fitness in crewmembers during space missions is essential for preserving performance for mission-critical tasks. NASA's Exercise Countermeasures Project (ECP) provides space exploration exercise hardware and monitoring requirements that lead to devices that are reliable, meet medical, vehicle, and habitat constraints, and use minimal vehicle and crew resources. ECP will also develop and validate efficient exercise prescriptions that minimize daily time needed for completion of exercise yet maximize performance for mission activities. In meeting these mission goals, NASA Glenn Research Center (Cleveland, OH, USA), in collaboration with the Cleveland Clinic (Cleveland, Ohio, USA), has developed a suite of zero-gravity locomotion simulators and associated technologies to address the need for ground-based test analog capability for simulating in-flight (microgravity) and surface (partial-gravity) exercise to advance the health and safety of astronaut crews and the next generation of space explorers. Various research areas can be explored. These include improving crew comfort during exercise, and understanding joint kinematics and muscle activation pattern differences relative to external loading mechanisms. In addition, exercise protocol and hardware optimization can be investigated, along with characterizing system dynamic response and the physiological demand associated with advanced exercise device concepts and performance of critical mission tasks for Exploration class missions. Three zero-gravity locomotion simulators are currently in use and the research focus for each will be presented. All of the devices are based on a supine subject suspension system, which simulates a reduced gravity environment by completely or partially offloading the weight of the exercising test subject s body. A platform for mounting treadmill is positioned perpendicularly to the test subject. The Cleveland Clinic Zero-g Locomotion Simulator (ZLS) utilizes a pneumatic subject load device to apply a near constant gravity-replacement load to the test subject during exercise, and is currently used in conjunction with the General Clinical Research Center for evaluating exercise protocols using a bedrest analog. The enhanced ZLS (eZLS) at NASA Glenn Research Center features an offloaded treadmill that floats on a thin film of air and interfaces to a force reaction frame via variably-compliant isolators, or vibration isolation system. The isolators can be configured to simulate compliant interfaces to the vehicle, which affects mechanical loading to crewmembers during exercise, and has been used to validate system dynamic models for new countermeasures equipment designs, such as the second International Space Station treadmill slated for use in 2010. In the eZLS, the test subject and exercise device can be pitched at the appropriate angle for partial gravity simulations, such as lunar gravity (1/6th earth gravity). On both the eZLS and the NASA-Johnson Space Center standalone ZLS installed at the University of Texas Medical Branch in Galveston, Texas, USA, the subject's body weight relative to the treadmill is controlled via a linear motor subject load device (LM-SLD). The LM-SLD employs a force-feedback closed-loop control system to provide a relatively constant force to the test subject during locomotion, and is set and verified for subject safety prior to each session. Locomotion data were collected during parabolic flight and on the eZLS. The purpose was to determine the similarities and differences between locomotion in actual and simulated microgravity. Subjects attained greater amounts of hip flexion during walking and running during parabolic flight. During running, subjects had greater hip range of motion. Trunk motion was significantly less on the eZLS than during parabolic flight. Peak impact forces, loading rate, and impulse were greater on the eZLS than during parabolic while walking with a low external load (EL) and rning with a high EL. Activation timing differences existed between locations in all muscles except for the rectus femoris. The tibialis anterior and gluteus maximus were active for longer durations on the eZLS than in parabolic flight during walking. Ground reaction forces were greater with the LM-SLD than with bungees during eZLS locomotion. While the eZLS serves as a ground-based analog, researchers should be aware that subtle, but measurable, differences in kinematics and leg musculature activities exist between the environments. Aside from space applications, zero-gravity locomotion simulators may help medical researchers in the future with development of rehabilitative or therapeutic protocols for injured or ill patients. Zero-gravity locomotion simulators may be used as a ground-based test bed to support future missions for space exploration, and eventually may be used to simulate planetary locomotion in partial gravity environments, including the Moon and Mars. Figure: Zero-gravity Locomotion Simulator at the Cleveland Clinic, Cleveland, Ohio, USA

Perusek, Gail P.↗

TransHab Tapered Diamond Stitch Methods - Crewed Inflatable Softgoods Structures

The NASA TransHab project was a flight development program of a crewed inflatable habitat designed for in-space use. Through the course of the development, several novel technologies were developed and patented by NASA. One of these patents included information regarding a custom seam stitch that was used in the TransHab restraint layer design. As the patent protection has ended, the details of the custom seam stitch are being disclosed. The seam stitch developed during the TransHab program is known as the ‘tapered diamond stitch’ and includes both a ‘single’ and ‘double’ tapered diamond pattern for ‘end termination’ and ‘continuous’ webbing components respectively. It was designed for 1-in wide Kevlar webbings with load ratings of 6,000 lbf and 12,500 lbf. The stitch pattern was designed to gradually transfer load along the length of the seam using a tapered diamond geometry. The diamond stitch has been shown in tensile testing to provide greater than 85% load strength efficiency, compared to the pristine webbing.

transhab↗

The physics of desiccation cracks 2: Modeling and prediction of the crack patterns

Here, this paper extends the experimental results of our companion paper by modeling and predicting the onset and pattern formation of desiccation cracks in geomaterials (Ruoyu et al., 2023). Thin-layer silt samples in controlled atmospheric conditions were tested to obtain the surface strain maps with the digital image correlation (DIC) method during dehydration. Support experiments, including consolidation and displacement-controlled triaxial tests, were conducted for the properties of geomaterials. These experimental results were used to validate a viscoplastic theoretical model by comparing cracks and singularities locations that distribute following the Cnoidal wave pattern. A critical value exists in the viscoplastic model that determines the number of singularities, which accurately predicts the number of cracks in the experiment. The critical values contain two crucial parameters: rate sensitivity and λ. Rate sensitivity describes the rate-dependent stress–strain relation, while λ shows the ability of pore pressure redistribution under the external mechanical loading rate. These results provide a new view to analyze the desiccation cracks considering the rate-dependent viscoplasticity.

42 ENGINEERING↗

High-rate strength response of tantalum from dynamic hole closure experiments

The science and engineering communities have significant interest in experimental platforms to evaluate and improve models for dynamic material deformation. While well-developed platforms exist, there are still gaps to fill for strain and strain rate conditions accessed during impact and other high-rate loading scenarios. To fill one such gap for strength measurements, a platform was recently developed that accesses high strain rate (≥ 10 5 /s) and large strain (≥ 50%) conditions by measuring the transient closure of a cylindrical hole using in situ x-ray imaging. In the work reported here, further refinement of the platform is performed to reduce the potential effects of porosity and anelasticity on the measurement. This helps us to isolate the strength effects that are the focus of the experiment. The updated experimental configuration employs a two-layer flyer design and elongated target to reduce the magnitude of the tensile excursions associated with rarefaction wave interactions. This allows for a more direct assessment of strength models commonly used for dynamic simulations of metals. Here we apply the new technique to well-characterized tantalum material, allowing for a robust connection to other experimental techniques. Deformation localization can be a concern in large strain experiments, and to help inform future use of the experimental platform, we use simulations with a sub-zone treatment of shear banding to explore potential localization behavior. Here we develop and utilize an experimental configuration with improved isolation of strength effects that can be applied to an expanded range of materials.

42 ENGINEERING↗

Deformation Behaviors in Single BCC‐Phase Refractory Multi‐Principal Element Alloys under Dynamic Conditions

The mechanical behavior and microstructural evolution of a BCC-phase NbTaTiV refractory multi-principal element alloy (RMPEA) is studied over a wide range of strain rates (10 −3 to 10 3 s −1 ) and temperatures (room temperature to 850 °C). The mechanical property of present RMPEA shows less strain-rate dependence and strong resistance to softening at high temperatures. Under high strain-rate loading, the formation of thin type-I twins is observed, which could lead to an increase in strain-hardening rates. However, this hardening mechanism competes with adiabatic heating effects, resulting in the deterrence of strain-hardening behaviors. In contrast, substantial strain-hardening occurs at cryogenic temperatures due to the formation of twins, which act as stronger barriers to dislocation motion and interact with each other. To further understand the different strain-hardening behaviors, density functional theory (DFT) calculations predict relatively low stacking fault energies and high twinning stress for the NbTaTiV RMPEA.

36 MATERIALS SCIENCE↗

SESOP: Program for solar-energy heating-systems analysis

Space heating and cooling loads are calculated for each building based on outside environment, desired inside conditions, building construction and geometry, domestic power usage, occupancy rate, and occupant metabolic rate. Loads are summed to determine requirements of central and alternative utility systems.

Source record↗

Effect of Strengthening Mechanism on Strain-Rate Related Tensile Properties of Low-Carbon Sheet Steels for Automotive Application

In order to ensure crash resistance of the steels used in automotive components, the ensile deformation behavior needs to be studied and predicted not only under quasi-static condition, but also under dynamic loading rates. In the present study, tensile tests have been performed on four different automobile grade sheet steels, namely interstitial free steel, dual-phase 600 and 800, and a carbon manganese steel over the strain rate regime of 0.001-800/s. Apart from the variation in strength (which always increased with strain rate), the effect of strengthening mechanism on strain rate sensitivity and strain hardening behavior has been evaluated. Strain rate sensitivity was found to increase at high-strain rate regime for all the steels. Contribution of solid solution hardening on strain rate sensitivity at lower plastic strains was found to be higher compared to dislocation strengthening and second-phase hardening. However, precipitation hardening coupled with solid solution hardening produced the highest strain rate sensitivity, in C-Mn-440 steel at high strain rates. Different strain-rate-sensitive models which take into account the change in yield stress and strain hardening behavior with strain rate for ductile materials were used to predict the flow behavior of these sheet steels at strain rates up to 800/s.

36 MATERIALS SCIENCE↗

On the role of geometrically necessary dislocations in void formation and growth in response to shock loading conditions in wrought and additively manufactured Ta

This study investigates the role of geometrically necessary dislocations (GNDs) and microstructure on void nucleation and growth in wrought and additively manufactured (AM) tantalum subjected to high-strain rate loading. Multi-modal 3D data was collected using TriBeam tomography to calculate GND densities and their spatial relationship to voids. A microstructural comparison between the wrought and AM samples identified distinct void shapes and locations, with intragranular voids and more spherical voids frequently observed in the AM dataset. Results indicate that voids preferentially form at both high-angle grain boundaries and low-angle subgrain boundaries, the latter of which are frequently observed in the AM material. Through a radial distribution analysis of all voids in the datasets, significant GND localization to near-void-surface regions was observed in both samples. 3D crystal plasticity simulations were employed to extend the experimental observations, revealing higher void growth rates in [111] oriented grains when compared to [001] grains. The simulations also suggest that GNDs can be generated as part of the void growth process, with more GND accumulation for growth in a [111] grain than a [001] grain. These findings provide valuable insights into the links between nanoscale void nucleation, mesoscale void growth, and microstructural effects in dynamically loaded tantalum.

36 MATERIALS SCIENCE↗

Thermal-mechanical fatigue test apparatus for metal matrix composites and joint attachments

Two thermal-mechanical fatigue (TMF) test facilities were designed and developed, one to test tungsten fiber reinforced metal matrix composite specimens at temperature up to 1430C (2600F) and another to test composite/metal attachment bond joints at temperatures up to 760C (1400 F). The TMF facility designed for testing tungsten fiber reinforced metal matrix composites permits test specimen temperature excursions from room temperature to 1430C (2600F) with controlled heating and loading rates. A strain-measuring device measures the strain in the test section of the specimen during each heating and cooling cycle with superimposed loads. Data is collected and recorded by a computer. The second facility is designed to test composite/metal attachment bond joints and to permit heating to a maximum temperature of 760C (1400F) within 10 min and cooling to 150C (300F) within 3 min. A computer controls specimen temperature and load cycling.

Westfall, L. J.↗

Thermal-mechanical fatigue test apparatus for metal matrix composites and joint attachments

Two thermal-mechanical fatigue (TMF) test facilities were designed and developed, one to test tungsten fiber reinforced metal matrix composite specimens at temperature up to 1430C (2600F) and another to test composite/metal attachment bond joints at temperatures up to 760F (1400F). The TMF facility designed for testing tungsten fiber reinforced metal matrix composites permits test specimen temperature excursions from room temperature to 1430C (2600F) with controlled heating and loading rates. A strain-measuring device measures the strain in the test section of the specimen during each heating and cooling cycle with superimposed loads. Data is collected and recorded by a computer. The second facility is designed to test composite/metal attachment bond joints and to permit heating to a maximum temperature of 760C (1400F) within 10 min and cooling to 150C (300F) within 3 min. A computer controls specimen temperature and load cycling.

Westfall, Leonard J.↗

A parametric study of the solar wind interaction with comets

The Naval Research Laboratory's magnetohydrodynamic simulation code is used to simulate the solar wind interction with comet Halley for two different outgassing rates and several different solar wind states. The magnetic field is more strongly draped for fast solar wind conditions than slow. For higher mass loading rates, the tail becomes wider and contains more magnetic flux. The visual appearance of the comet differs for the case in which the interplanetary magnetic field lies in the plane of the sky from the case when it lies along the line of sight. The ion tail appears shorter in the latter case. Thus variation in the IMF direction can cause significant changes in the appearance of comets. The comet also creates a large momentum flux deficit in the solar wind with a narrow enhanced region within it corresponding to the ion tail.

Russell, C. T.↗

The High-Frequency Signature of Slow and Fast Laboratory Earthquakes

Tectonic faults fail through a spectrum of slip modes, ranging from slow aseismic creep to rapid slip during earthquakes. Understanding the seismic radiation emitted during these slip modes is key for advancing earthquake science and earthquake hazard assessment. In this work, we use laboratory friction experiments instrumented with ultrasonic sensors to document the seismic radiation properties of slow and fast laboratory earthquakes. Stick-slip experiments were conducted at a constant loading rate of 8 μm/s and the normal stress was systematically increased from 7 to 15 MPa. We produced a full spectrum of slip modes by modulating the loading stiffness in tandem with the fault zone normal stress. Acoustic emission data were recorded continuously at 5 MHz. We demonstrate that the full continuum of slip modes radiate measurable high-frequency energy between 100 and 500 kHz, including the slowest events that have peak fault slip rates <100 μm/s. The peak amplitude of the high-frequency time-domain signals scales systematically with fault slip velocity. Stable sliding experiments further support the connection between fault slip rate and high-frequency radiation. Experiments demonstrate that the origin of the high-frequency energy is fundamentally linked to changes in fault slip rate, shear strain, and breaking of contact junctions within the fault gouge. Our results suggest that having measurements close to the fault zone may be key for documenting seismic radiation properties and fully understanding the connection between different slip modes.

58 GEOSCIENCES↗

On factors controlling precursor slip fronts in the laboratory and their relation to slow slip events in nature

Spatial variations in frictional properties on natural faults are believed to be a factor influencing the presence of slow slip events (SSEs). This effect was tested on a laboratory frictional interface between two polymethyl methacrylate (PMMA) bodies. We studied the evolution of slip and slip rates that varied systematically based on the application of both high and low normal stress (σ 0 =0.8 or 0.4 MPa) and the far-field loading rate (V LP ). A spontaneous, frictional rupture expanded from the central, weaker, and more compliant section of the fault that had fewer asperities. Slow rupture propagated at speeds V slow ~0.8 to 26 mm s -1 with slip rates from 0.01 to 0.2 μm s -1 , resulting in stress drops around 100 kPa. During certain nucleation sequences, the fault experienced a partial stress drop, referred to as precursor detachment fronts in tribology. Only at the higher level of normal stress did these fronts exist, and the slip and slip rates mimicked the moment and moment release rates during the 2013–2014 Boso SSE in Japan. The laboratory detachment fronts showed rupture propagation speeds V slow /V R ϵ (5 to 172) × 10 -7 and stress drops ~ 100 kPa, which both scaled to the aforementioned SSE. Distributions of asperities, measured using a pressure sensitive film, increased in complexity with additional normal stress—an increase in normal stress caused added complexity by increasing both the mean size and standard deviation of asperity distributions, and this appeared to control the presence of the detachment front.

58 GEOSCIENCES↗

The Creep of Single Crystals of Aluminum

The creep of single crystals of high-purity aluminum was investigated in the range of temperatures from room temperature to 400 F and at resolved-shear-stress levels of 200, 300, and 400 psi. The tests were designed in an attempt to produce data regarding the relation between the rate of strain and the mechanism of deformation. The creep data are analyzed in terms of shear strain rate and the results are discussed with regard to existing creep theories. Stress-strain curves were determined for the crystals in tinsel and constant-load-rate tests in the same temperature range to supplement the study of plastic deformation by creep with information regarding the part played by crystal orientation, differences in strain markings, and other variables in plastic deformation.

ALUMINUM↗

The effects of inherent flaws on the time and rate dependent failure of adhesively bonded joints

Inherent flaws, as well as the effects of rate and time, are shown by tests on viscoelastic adhesive-bonded single lap joints to be as critical in joint failure as environmental and stress concentration effects, with random inherent flaws and loading rate changes resulting in an up to 40% reduction in joint strength. It is also found that the asymptotic creep stress, below which no delayed failure may occur, may under creep loading be as much as 45% less than maximum adhesive strength. Attention is given to test results for the case of titanium-LARC-3 adhesive single-lap specimens.

Sancaktar, E.↗

Strong strain rate effect on the plasticity of amorphous silica nanowires

With electron-beam (e-beam) off, in-situ tensile experiments on amorphous silica nanowires (NWs) were performed inside a transmission electron microscope (TEM). By controlling the loading rates, the strain rate can be adjusted accurately in a wide range. The result shows a strong strain rate effect on the plasticity of amorphous silica NWs. At lower strain rate, the intrinsic brittle materials exhibit a pronounced elongation higher than 100% to failure with obvious necking near ambient temperature. At the strain rate higher than 5.23 × 10{sup −3}/s, the elongation of the NW decreased dramatically, and a brittle fracture feature behavior was revealed. This ductile feature of the amorphous silica NWs has been further confirmed with the in-situ experiments under optical microscopy while the effect of e-beam irradiation could be eliminated.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Verification of the Multi-Axial, Temperature and Time Dependent (MATT) Failure Criterion

An extensive test and analytical effort has been completed by the Space Shuttle's Reusable Solid Rocket Motor (KSKM) nozzle program to characterize the failure behavior of two epoxy adhesives (TIGA 321 and EA946). As part of this effort, a general failure model, the "Multi-Axial, Temperature, and Time Dependent" or MATT failure criterion was developed. In the initial development of this failure criterion, tests were conducted to provide validation of the theory under a wide range of test conditions. The purpose of this paper is to present additional verification of the MATT failure criterion, under new loading conditions for the adhesives TIGA 321 and EA946. In many cases, the loading conditions involve an extrapolation from the conditions under which the material models were originally developed. Testing was conducted using three loading conditions: multi-axial tension, torsional shear, and non-uniform tension in a bondline condition. Tests were conducted at constant and cyclic loading rates ranging over four orders of magnitude. Tests were conducted under environmental conditions of primary interest to the RSRM program. The temperature range was not extreme, but the loading ranges were extreme (varying by four orders of magnitude). It should be noted that the testing was conducted at temperatures below the glass transition temperature of the TIGA 321 adhesive. However for the EA946, the testing was conducted at temperatures that bracketed the glass transition temperature.

Richardson, David E.↗