Development of a High-Rate Front-End ASIC for X-Ray Spectroscopy and Diffraction Applications

We developed a new front-end application-specific integrated circuit (ASIC) to upgrade the Maia X-ray microprobe. The ASIC instruments 32 configurable channels that perform either positive or negative charge amplification, pulse shaping, peak amplitude, and time extraction along with buffered analog storage. At a gain of 3.6 V/fC, 1-μs peaking time, and a temperature of 248 K, an electronic resolution of 13 and 10 e- rms was measured with and without a silicon drift detector (SDD) sensor, respectively. A spectral resolution of 170-eV full-width at half-maximum (FWHM) at 5.9 keV was obtained with an 55Fe source. The channel linearity was better than ± 1% with rate capabilities up to 40 kcps. The ASIC was fabricated in a commercial 250-nm process with a footprint of 6.3 mm × 3.9 mm and dissipates 167 mW of static power.

Vernon, Emerson↗

The Belle II imaging Time-of-Propagation (iTOP) Detector

High precision flavor physics measurements are an essential complement to the direct searches for new physics at the LHC. Such measurements will be performed using the upgraded Belle II detector that will take data at the SuperKEKB accelerator. With 40x the luminosity of KEKB, the detector systems must operate eciently at much higher rates than the original Belle detector. A central element of the upgrade is the barrel particle identication system. Belle II has built and installed an imaging-Time-of-Propagation (iTOP) detector. The iTOP uses quartz optics as Cerenkov radiators. The photons are transported down the quart bars via total internal reection with a spherical mirror at the forwardend to reflect photons to the backward end where they are imaged onto an array of segmented Micro-Channel Plate Photo-Multiplier Tubes. The system is readout using gigsample per second waveform sampling Application-Specific Integrated Circuits that provide precise photon timing. The combined timing and spatial distribution of the photons for each event are used to determine particle species. This paper provides an overview of the iTOP system.

Fast, James E.↗

Optimizing Short-Term Operation of a FIRES-like Industrial Heat Supply Thermal Energy Storage System

The Firebrick Resistance-heated Energy-storage System (FIRES) is under development at MIT for two applications: (1) integration with the Nuclear Air-Brayton Combined Cycle (NACC), a high-performance power conversion system (PCS) that may be used with high- temperature advanced reactors; and (2) industrial heat supply. This paper describes some key features of FIRES and equivalent systems configured for industrial heat supply and presents an assessment of the revenue achievable by a system operating under the conditions expected for early demonstration FIRES installations. The greatest technical challenge of the 21. century is likely to be the effort to minimize the damage caused by global climate change. This effort will require massive reductions in greenhouse gas (GHG) emissions throughout our economy and a transition to an electric power system driven entirely by very-low-carbon generators. Many investigators agree that this will require a substantial increase in electricity generation and in the use of nuclear power, and there is growing awareness that this will also require new technologies and systems for managing and storing energy and matching intermittent supply of renewable resources with electricity demand. Thermal energy storage systems (TESS) will, in some applications, be much more cost effective than the more popular and widely discussed battery electric storage systems and may provide unique capabilities. The Firebrick Resistance-heated Energy-storage System (FIRES) is under development at MIT for two applications: (1) integration with the Nuclear Air-Brayton Combined Cycle (NACC), a high-performance power conversion system (PCS) that may be used with high-temperature advanced reactors like the Fluoride-salt-cooled High-temperature Reactor (FHR), molten salt reactor (MSR) and sodium-cooled fast reactors (SFR); and (2) industrial heat supply. FIRES installations include a stack of refractory firebrick with imbedded electric heaters and airflow channels, a compressor or air blower, and a duct system to connect the firebrick with the heat demand (turbine or industrial customer). Analysis of the FIRES design space has shown that the concept is suitable for a wide range of peak operating temperatures (from about 200 deg.C up to at least 1800 deg. C) and pressures (from ambient to at least 20 atmospheres) and offers very high energy density (up to 1 MWh per cubic meter of firebrick for high temperature systems) at very low cost (as low as $5/kWh). These results favor early demonstration of FIRES. If the cost target of $5/kWh for FIRES systems were achieved, even the lowest expected operating income calculated here could cover the capital cost of a 10 MWh system in a single year. If the FIRES system were assumed to operate for at least 10 years, this level of operating income could readily recover a capital investment up to $50/kWh, which is simultaneously much cheaper than the costs expected for near-future battery systems (in excess of $200/kWh) and much more expensive than the small, low temperature firebrick systems already available for domestic heating. This provides a large margin for unexpected development costs and other uncertainties. FIRES would set a minimum price of electricity near that of natural gas-improving nuclear, wind, and solar economics while reducing greenhouse gas emissions from the industrial sector. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

THE INTEGRATION OF PROCESS HEAT APPLICATIONS TO HIGH TEMPERATURE GAS REACTORS

A high temperature gas reactor, HTGR, can produce industrial process steam, high-temperature heat-transfer gases, and/or electricity. In conventional industrial processes, these products are generated by the combustion of fossil fuels such as coal and natural gas, resulting in significant emissions of greenhouse gases such as carbon dioxide. Heat or electricity produced in an HTGR could be used to supply process heat or electricity to conventional processes without generating any greenhouse gases. Process heat from a reactor needs to be transported by a gas to the industrial process. Two such gases were considered in this study: helium and steam. For this analysis, it was assumed that steam was delivered at 17 MPa and 540 C and helium was delivered at 7 MPa and at a variety of temperatures. The temperature of the gas returning from the industrial process and going to the HTGR must be within certain temperature ranges to maintain the correct reactor inlet temperature for a particular reactor outlet temperature. The returning gas may be below the reactor inlet temperature, ROT, but not above. The optimal return temperature produces the maximum process heat gas flow rate. For steam, the delivered pressure sets an optimal reactor outlet temperature based on the condensation temperature of the steam. ROTs greater than 769.7 C produce no additional advantage for the production of steam.

01 COAL, LIGNITE, AND PEAT↗

Stochastic risk-sensitive market integration for renewable energy: Application to ocean wave power plants

With the expected increase of intermittent renewable energy resources on the electric power grid, short-term reserve markets can prove to be a critical reliability asset. This paper introduces and tests a potential market structure that includes a short-term reserve market for renewable resources where the realized energy is drawn within the bounds of the hourly capacity offered. The study presents a risk-aware stochastic model that determines, based on the day-ahead offer derived using a classic newsvendor formula, the best intraday offers for a renewable energy power plant. The stochastic approach takes into account the uncertainties of energy production and market prices. The proposed risk-sensitive model aims to maximize the renewable power plant's revenues and minimize potential risks of loss in a multi-product multi-timescale market setup. To demonstrate the effectiveness of the proposed formulation, we study the case of a hypothetical 750-kW wave power plant coupled with energy storage. The study shows that the risk of profit loss is not uniformly distributed across the risk-aversion factor space. We also find that the introduction of the short-term reserve market results in a wider range of conditional value at risk while inducing 5% profit increase and a lower profit reduction across the risk range. In addition, the study reveals that the short-term reserve market is profitable for both the system operator and the wave energy power plant considered.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High-Throughput Computation and the Applicability of Monte Carlo Integration in Fatigue Load Estimation of Floating Offshore Wind Turbines

Long-term fatigue loads for floating offshore wind turbines are hard to estimate because they require the evaluation of the integral of a highly nonlinear function over a wide variety of wind and wave conditions. Current design standards involve scanning over a uniform rectangular grid of metocean inputs (e.g., wind speed and direction and wave height and period), which becomes intractable in high dimensions as the number of required evaluations grows exponentially with dimension. Monte Carlo integration offers a potentially efficient alternative because it has theoretical convergence proportional to the inverse of the square root of the number of samples, which is independent of dimension. In this paper, we first report on the integration of the aeroelastic code FAST into NREL's systems engineering tool, WISDEM, and the development of a high-throughput pipeline capable of sampling from arbitrary distributions, running FAST on a large scale, and postprocessing the results into estimates of fatigue loads. Second, we use this tool to run a variety of studies aimed at comparing grid-based and Monte Carlo-based approaches with calculating long-term fatigue loads. We observe that for more than a few dimensions, the Monte Carlo approach can represent a large improvement in computational efficiency, but that as nonlinearity increases, the effectiveness of Monte Carlo is correspondingly reduced. The present work sets the stage for future research focusing on using advanced statistical methods for analysis of wind turbine fatigue as well as extreme loads.

17 WIND ENERGY↗

A guideline for appropriate application of vertically-integrated modeling approaches for geologic carbon storage modeling

Mathematical modeling is an essential tool for answering questions related to geologic carbon storage (GCS). The choice of modeling approach depends on the type of questions being asked. In this paper we discuss a series of approaches with a hierarchical complexity including vertically-integrated single-phase flow approaches, vertically-integrated multi-phase flow approaches (with and without vertical equilibrium assumption), three-dimensional multi-phase flow approaches, and fully-coupled multi-phase flow approaches that couple flow with geochemistry and/or geomechanics. Three spatial scales are used to categorize the questions to be addressed by modeling: regional scale (encompasses CO 2 plume extent and majority of area of pressure impact of one or more injection operations), site scale (includes the CO 2 plume extent and some of the area impacted by the pressure increase of a single injection site), and well scale (the immediate vicinity of an injection well). A set of guidelines is developed to help modelers choose the most appropriate modeling approach, and show when simpler modeling approaches may be the better choice. Vertically-integrated single-phase flow models are the most appropriate choice at both the site and regional scales, if the pressure impact outside of the CO 2 plume is of interest. Vertically-integrated multi-phase flow models should be chosen at the regional scale, if the locations of CO 2 plumes are of interest, and at the site scale if vertical segregation of CO 2 and brine is fast or vertical heterogeneity in properties can be presented by distinct, continuous layers. Three-dimensional multi-phase flow models are the appropriate choice at the well and site scales for cases with significant vertical flow components of CO 2 and brine. Fully-coupled multi-phase flow models should only be chosen if pore-space alteration through geochemistry or geomechanics feeds back to fluid flow.

42 ENGINEERING↗

Developing A Large Time Step, Robust, and Low Communication Multi-Moment PDE Integration Scheme for Exascale Applications

The Boundary Averaged Multi-moment Constrained finite-Volume (BA-MCV) method is de- rived, explained, and evaluated for 1-D transport to assess accuracy, maximum stable time step (MSTS), oscillations for discontinuous data, and parallel communication burden. The BA-MCV scheme is altered from the original MCV scheme to compute the updates of point wise cell boundary derivatives entirely locally. Then it is altered such that boundary moments are replaced with the interface upwind value. The scheme is stable at a maximum stable CFL (MSCFL) value of one no matter how high-order the scheme is, giving significantly larger time steps than Galerkin methods, for which the MSCFL decreases nearly quadratically with in- creasing order. The BA-MCV method is compared against a SE method at varying order, both using the ADER-DT time discretization. BA-MCV error for a sine wave was comparable to the same order of accuracy for a SE method. The resulting large time step, multi-moment, low communication scheme is of great interest for exascale architectures.

Norman, Matthew R.↗

Gaia: segmented germanium detector for high-energy X-ray fluorescence and spectroscopic imaging

We present Gaia, a monolithic array of 96 high-purity germanium pixel detectors integrated with a custom low-noise application-specific integrated circuit (ASIC) and a field-programmable gate array (FPGA)-based data acquisition system. The sensor operates at ∼100 K using a commercial closed-cycle cryocooler, with the in-vacuum electronics thermally isolated from the cold finger to ensure thermal stability. The system demonstrates an average energy resolution of 711 eV at 122 keV, measured using a 57 Co source, and 253 eV at 5.89 keV, measured with 55 Fe across all channels. The readout architecture incorporates a high-performance FPGA paired with a dual-core ARM processor, forming a complete embedded Linux-based computing platform. Communication between the processor and FPGA is handled via memory-mapped I/O, and data are streamed over high-speed gigabit Ethernet. A full-scale 384-pixel Gaia detector, based on this 96-element module, is currently under fabrication.

36 MATERIALS SCIENCE↗

Application of a Heat Integrated Post-combustion CO 2 Capture System with Hitachi Advanced Solvent into Existing Coal-Fired Power Plant (Final Technical Report)

The goal of this final project report is to comprehensively summarize the work conducted on project DE-FE0007395. In accordance with the Project Management Plan (PMP), Revision F dated 5/10/2019, and Statement of Project Objectives (SOPO) within, the University of Kentucky (UK) Center for Applied Energy Research (CAER) (Recipient) has successfully demonstrated a unique, versatile CO 2 capture system (CCS) using a heat integrated process combined with two-stage stripping for process intensification, heat recovery and demineralized (DM) water generation. This project involved the design, fabrication, installation, testing of and data analysis from the UK CAER 0.7 MWe small pilot scale CO2 capture process installed at Kentucky Utilities (KU) E.W. Brown Generating Station in Harrodsburg, KY. During each of the four project Budget Periods (BPs), UK CAER met all project deliverables, all project milestones, with National Energy Technology Laboratory (NETL) approved adjustments made to the campaign long-term hours during BP4. The CCS was constructed in modular skids. Two solvent campaigns were initially conducted; the first with a 30 wt% monoethanolamine (MEA) as a baseline, and the second with the Hitachi H3-1 advanced solvent. Additional tests were performed with two advanced solvents including CAER and Proprietary Solvent C. Short-period testing with a higher concentration of 40 wt% MEA was conducted to evaluate the potential saving with high alkalinity. From the various solvent campaigns, unique aspects of the UK CAER CCS technology, as well as its flexibility and versatility were experimentally validated and demonstrated. With respect to solvent evaluation efforts in identifying candidates with significant operational and capital cost savings potential, performance of solvents were evaluated to determine the energy requirements for regeneration; environmental impacts from secondary emissions and degradation products; degradation rates, solvent make-up rates and stability. The assessments were done from parametric tests that determined optimum operating conditions for the individual solvents to maximize process efficiency and minimize the parasitic load of the power plant, and from long term campaigns (1000 hours for 30 wt% MEA and 1000 hours for H3-1) which collectively informed the techno-economic analyses (TEA) of the process. The long term campaigns included corrosion studies which used three types of metal coupons in different sections of the process: (absorber, primary stripper, lean carbon-loaded and rich carbon loaded flow streams in process) to mimic heat and flow dynamics process equipment were exposed to. The estimated corrosion rates were used to elucidate corrosion mechanisms and to further guide process material selection for potential capital cost savings.

gas separation↗

Environmental, Health and Safety Assessment Application of a Heat Integrated, Post-combustion CO2 Capture System Using Monoethanolamine and Hitachi H3-1 Solvent at the E.W. Brown Coal-fired Power Plant

An Environmental Health and Safety (EH&S) Assessment was completed for operation of a pilot scale carbon dioxide (CO2) capture system (CCS) at the Louisville Gas & Electric (LG&E) and Kentucky Utilities (KU) Energy, LLC (LG&E-KU) E. W. Brown Generating Station in Harrodsburg, Mercer County, Kentucky. The pilot system was evaluated using two CO2 capture solvents, monoethanolamine (MEA) and Hitachi’s H3-1 solvent. The purpose of the EH&S Assessment was to determine if there were any unacceptable environmental, health or safety concerns that may prevent operation or environmental permitting of a larger scale pilot scale plant. The assessment included review of process flow diagrams, input and output flow rates for primary materials, literature describing similar processes and chemicals used or created during the process, actual air emission and wastewater test data and air emission calculations. The evaluation included identification of risks related to hazardous chemicals, air emissions, wastewater discharges, solid wastes generated and employee hazards. Most potential EH&S issues that were identified are commonly found and successfully managed at large industrial facilities. No risks were identified that could not be successfully managed or would likely prevent implementation or environmental permitting of the pilot or larger scale plant. Potential exposures and resulting health risks from exposure to low concentrations of nitrosamines generated from degradation of the Hitachi H3-1 and possibly MEA solvents may be a health concern for site workers, but additional investigation is needed to accurately assess this risk. Applying the information gained from operating the pilot plant, performing air emission testing and used solvent testing to a large-scale facility at a commercial coal-fired electric generating plant suggests additional air emission control measures may be necessary to reduce potential site worker health risks and possibly community risks. Depending upon the location and regional air quality, considerable effort may be required to obtain the necessary air permit for construction and operation of a similarly configured large-scale PCCCS facility.

gas separation↗

FINAL TECHNICAL AND ECONOMIC FEASIBILITY STUDY ON THE APPLICATION OF A HEAT INTEGRATED POST-COMBUSTION CO2 CAPTURE SYSTEM WITH HITACHI ADVANCED SOLVENT INTO EXISTING COAL-FIRED POWER PLANT

This report contains the results of a techno-economic assessment (TEA) conducted of a heat integrated post-combustion CO2 capture process with Hitachi advanced solvent for retrofit into an existing coal-fired power plant (but treated as greenfield plant on cost analysis). The process has been developed by the University of Kentucky Center for Applied Energy (UK CAER). EPRI was chiefly responsible for this analysis, with significant input from WorleyParsons, Hitachi Power Systems America (Hitachi) and UK CAER. The project also involves the design, fabrication, installation, testing, and analyses of a slipstream facility located at L&GE-KU’s E.W. Brown Generating Station to demonstrate the UK CAER carbon capture system that could utilize heat integration with the main power plant. The design, start-up, and baseline of the pilot system was performed with a generic 30 wt% MEA solvent to obtain data for direct comparison with the DOE/NETL Reference Case followed by testing Hitachi’s proprietary solvent H3-1. In this techno-economic analysis, two cases utilizing the UK CAER process are compared, using different approach temperatures and solvent, against the DOE/NETL Reference Case (Case 10). The results are shown comparing the energy demand for post-combustion CO2 capture and the net higher heating value (HHV) efficiency of the power plant integrated with the post-combustion capture (PCC) plant. A levelized cost of electricity (LCOE) assessment was performed showing the costs of the options presented in the study. The key factors contributing to the reduction of LCOE were identified as CO2 partial pressure increase at the flue gas inlet, thermal integration of the process, and performance of the Hitachi H3-1 solvent. Recent UK CAER process pilot-scale testing data and process simualtion data showed that the packing heights of absorber and stripper columns were significantly oversized in the prelimanary TEA (Task 2 of this project) and thus updated in this final TEA for the H3-1 case only. In addition, the solvent make-up cost for H3-1 was updated based on lattest test results. Finally, a heat integration with the main power plant was applied in this final TEA to increase overall energy effciency for both the MEA and H3-1 cases. Additonal reductions in capital and operational costs are expected but not taken into account here. Shorter columns result in reduced pressure drops, smaller blower head and pump hydraulic head requirements. An increase in overall energy efficiency resuls in a decreased size of the power plant, the CCS and a reduced parasitic steam requirement to the CCS. The net efficiency of the UK CAER integrated PC power plant with CO2 capture changes from 26.2% for the Reference Case 10 plant in 2010 revised DOE/NETL baseline report to 27.6% for the MEA options considered, and 29.1% for the options utilizing the Hitachi advanced solvent. The UK CAER Process + Hitachi case also produces an extra 30.9 MW of generation compared to the UK CAER Process + MEA case and total 60.9 MW more than DOE Case 10. LCOE ($/MWh) values are $172.08/MWh for the MEA option and $157.65/MWh for the Hitachi H3-1 solvent cases considered in comparison to $189.59/MWh in January 2012 dollar for the Reference Case 10. The UK CAER CCS process with MEA case lowers energy consumption for CO2 capture to 1340 Btu/lb-CO2 captured as compared to 1540 Btu/lb-CO2 in the Reference Case 10. The UK CAER CCS process with H3-1 case further lowers energy consumption for CO2 capture to 973 Btu/lb-CO2 captured, for an advantage of 36.8% less energy consumption than Case 10. The study also shows 38.1% less heat rejection associated with the carbon capture system from 3398 MBtu/hr (Case 10) to 2104 MBtu/hr for the UK CAER + MEA system. Heat rejection is reduced to 2464 MBtu/hr in the UK CAER + H3-1 case, for a 27.5 % decrease compared to Case 10. Modeling outputs show that in the UK CAER process, the cooling water that is 2-5°C cooler than conventional cooling tower water can be achieved for ambient conditions common to the midwest and other regions. The results from the techno-economic assessment show that the proposed technology can be investigated further as a viable alternative to conventional CO2 capture technology. The evaluation also shows the effect of the critical parameters on the LCOE, with the main variables being the approach temperature and CO2 partial pressure increase at the flue gas inlet. A summary of the key advantages of the UK CAER Process + H3-1 case for LCOE and other economic factors compared to the DOE Case 10 is as follows: • A lower variable operating cost by $1.56/MWh ($1.08MWh less than the UK CAER Process + MEA Case), a 11.7% reduction compared to the DOE Case 10 • A lower COE by $25.32MWh ($13.94/MWh lower than the UK CAER Process + MEA Case), a 16.9% reduction compared to the DOE Case 10 • A lower LCOE by $31.94/MWh ($17.51/MWh lower than the UK CAER Process + MEA Case), a 16.9% reduction compared to the DOE Case 10 • A lower cost of CO2 captured by $18.65/tonne CO2 ($9.44/tonne CO2 lower than the UK CAER Process + MEA Case), a 30.4% reduction compared to the DOE Case 10 • A lower cost of CO2 avoided by $34.95/tonne CO2 ($18.53 tonne CO2 lower than the UK CAER Process + MEA Case), a 38.7% reduction compared to the DOE Case 10

Bhown, Abhoyjit S.↗