Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Instrumentation and Detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Simulation results for a low energy nuclear recoil yields measurement in liquid xenon using the MiX detector

Measuring the scintillation and ionization yields of liquid xenon in response to ultra-low energy nuclear recoil events is necessary to increase the sensitivity of liquid xenon experiments to light dark matter. Neutron capture on xenon can be used to produce nuclear recoil events with energies below 0.3 keV NR via the asymmetric emission of γ rays during nuclear de-excitation. The feasibility of an ultra-low energy nuclear recoil measurement using neutron capture was investigated for the Michigan Xenon (MiX) detector, a small dual-phase xenon time projection chamber that is optimized for a high scintillation gain. Simulations of the MiX detector, a partial neutron moderator, and a pulsed neutron generator indicate that a population of neutron capture events can be isolated from neutron scattering events. Additionally, the rate of neutron captures in the MiX detector was optimized by varying the thickness of the partial neutron moderator, neutron pulse width, and neutron pulse frequency.

detector calibration↗

Study of 149 Sm Capture and Total Cross Sections for Burnup Credit Applications [Slides]

This presentation highlights how capture and transmission measurements were performed with the DANCE (Detector for Advanced Neutron Capture Experiments) instrument with capture data from 8 eV – 1 keV, and DICER (Device for Indirect Capture Experiments on Radionuclides) instruments with transmission data from 1meV – 1 keV. There were additional measurements of 147 Sm which had contaminant in the samples, 3.4 eV strong resonance, interesting abnormalities. The data analysis is complete and the R-Matrix analysis almost (90%) complete.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Efficient Optimization of Plasma Radiation Detector Configurations using Imperfect Inference Models

The configurations of instruments fielded on an experiment affect the amount of information captured and the quality of subsequent inference. Here, we investigate the problem of optimizing plasma x-ray radiation detectors in a magneto-inertial fusion experiment at Sandia National Laboratories. It is impossible to directly measure properties such as the temperature of the thermonuclear fusion plasma produced in these experiments because of the extreme environment and destructive nature of the experiment. Among other diagnostics, several detectors are placed with significant standoff from the fusion target to capture the x-rays emitted by the fusion plasma, which can be used to infer some of its properties. To optimize the configuration of these detectors, a high-fidelity model (HFM) is used for simulating outputs and a low-fidelity model (LFM) is used for inference. We develop methods based on A- and L-optimality criteria that are efficient to compute while explicitly accounting for the discrepancy between the HFM and the LFM. The method allows us to find detector configurations that perform similarly to or better than the configuration obtained using an existing sampling-based optimization method while decreasing computational time by a factor of 50. Supplementary materials for this article are available online, including a standardized description of the materials available for reproducing the work.

Bayesian optimization↗

Commissioning and operation in magnetic field of CMS GE1/1 station

In October and November 2021 the CMS Gas Electron Multiplier (GEM) detectors of station GE1/1 were operated for the first time in presence of a magnetic field in CMS. The phenomena observed in this first period led to performing a test on GE1/1 chambers to study their behaviour in presence of a magnetic field ramp. The magnetic field has been created using the Goliath magnet installed in the CERN North Area. In conclusion, the aim of the test is to determine if a magnetic field ramp causes serious problems to the operation of the GEM chambers and to develop a clear set of procedures, that will permit the safe operations of the GEM chambers during a magnetic field ramp.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a synthetic phase contrast imaging diagnostic for turbulence studies at Wendelstein 7-X

Abstract We present a synthetic phase contrast imaging (PCI) diagnostic for studying turbulence at the Wendelstein 7-X (W7-X) stellarator. We first describe the implemented instrument response model, which captures diffraction effects, detector noise, and the long-wavelength cutoff due to the phase plate of the PCI system. To verify the instrument response model, we show that it is capable of reproducing the PCI signal generated by the sound wave speaker used for calibration at W7-X. Next, we discuss the calculation of synthetic PCI signals based on the global, nonlinear gyrokinetic codes GENE-3D and EUTERPE, including results from some of the first stellarator simulations of this type with kinetic electrons (KEs) in GENE-3D. While the simulations used in this work lack a neoclassical radial electric field, which is crucial for reproducing experimental PCI signals, they do indicate that the dominant rotation direction and velocities of the turbulent fluctuations can be inferred from the wave number-frequency spectra of the PCI signals, as expected. The synthetic PCI wave number spectra are further shown to be similar to those of the line-integrated fluctuating electron density, with distinct differences between adiabatic and KE simulations, explainable by previously published turbulence models. For example, the wave number spectra of all adiabatic electron simulations analyzed here follow a power law with an exponent close to −5 for sufficiently large wave numbers. This indicates that universal features of electron density turbulence at W7-X may be studied using the PCI system.

EUTERPE↗

Investigating Gadolinium-Lined Sodium-Iodide Neutron Detectors for Mobile Applications

For enhancing the effectiveness of nonproliferation efforts in neutron detection, most portable instruments rely on 6 Li scintillators, 10 B-based detectors, or gas-filled 3 He proportional counters. Additionally, gamma-ray detectors based on scintillators and semiconductors are often employed for search applications to find radioactive material in the field. These systems typically include dedicated detectors along with separate high voltage supplies and processing electronics for the gamma-ray and neutron detectors. Ideally, a portable radiation detection system should be lightweight, compact, and cost-effective. In the field, scintillators can serve a dual purpose: (1) detecting gamma-rays and (2) detecting neutrons. Gamma-ray detection with scintillators is based on the interaction of gamma-rays within the scintillating material, whereas neutron detection depends indirectly on neutron capture events. These capture events generate conversion electrons and gamma-rays, which can interact with the scintillator. For enhancing neutron capture, the scintillator can be surrounded by neutron absorber materials with a high neutron cross section. The resulting secondary electrons and gamma-rays from neutron interactions, depending on the absorber material used, can then be analyzed to detect the presence of neutron sources. Similarly, semiconductor-based detectors can be employed along with neutron absorbers as liners for neutron detection. 158 Gd has a significantly larger neutron cross section than 3 He, commonly used in gas-filled proportional counters, as shown in Figure 1. For thermal (0.025 eV) neutrons, the absorption cross section of 158 Gd is 10,000 times greater than that of 3 He (refer to Figure 1). This feature makes naturally occurring gadolinium, which consists of 24.8% 158 Gd, a promising neutron absorber material for use in combination with gamma-ray detectors–yielding a hybrid detector–for neutron detection.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Effect of Near-field Distribution on Transmission Characteristics of Fiber-fed Fabry–Perot Etalons

Fiber-fed etalons are widely employed in advanced interferometric instruments such as gravitational-wave detectors, ultrastable lasers and calibration reference for high-precision spectrographs. We demonstrate that variation in near-field distribution of the feeding fiber would deteriorate the spectrum precision of the fiber-fed Fabry–Perot etalon, especially when precision at the order of 3 × 10{sup -10} or higher is required. The octagonal fiber reinforced with double scrambler could greatly improve the steadiness and uniformness of the near-field distribution. When building wavelength calibrators for sub-m s{sup -1} precision radial-velocity instruments, the double scrambler should be considered meticulously.

47 OTHER INSTRUMENTATION↗

DRiFT Current Mode, Trigger Settings and Flexible Detector Specifications Applied to Scintillator Arrays

MCNP radiation transport output is post-processed by DRiFT, a Detector Response Function Toolkit to simulate detailed nuclear instrumentation response. DRiFT can be used to assess the performance and potential limitations of scintillator, gas, and semiconductor detectors under a variety of simulated conditions not easily achievable in a laboratory setting. This work describes new updates in DRiFT for scintillator simulations which focus on the capability to simulate scintillators in current mode, an expansion of trigger options, and the ability to customize individual detector properties in a simulation. These improvements are designed to facilitate the ability to model large arrays of scintillator detectors with higher fidelity than was previously possible and are demonstrated in three examples. The first shows the difference between operating DRiFT in current and pulse mode. In the second example, which is intended to demonstrate deviations in individual detector performance, each detector has properties (PMT gain, optical transport, scintillation yield, etc.) that vary between detectors and are specified in DRiFT. A final example examines how DRiFT could be used to optimize digitizer settings in high rate measurements with split signals using the new common trigger option.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Construction and Commissioning of Gas Electron Multiplier (GEM) Detectors in Advanced Assembly Design for Low-Energy Applications at High Rates and Analysis of GEM Data From the Muse Experiment at PSI

The search beyond the Standard Model explores dark matter and a potential fifth force. DarkLight@ARIEL investigates the dark photon as a mediator between ordinary and dark matter. The experiment aims to measure the process e?Ta ? e?TaX ? e?Ta(e?e+), by detecting a charged lepton pair in the final state. The spectrometers will be instrumented with Gas Electron Multiplier (GEM) detectors with minimal material budget for tracking. A novel GEM construction technique is employed for fabricating 25 cm x 40 cm GEM detectors, where all layers are mechanically stretched and assembled within a double frame. The dissertation outlines physics motivation, methods, experimental setup, and the role of GEM detectors in DarkLight. A comprehensive discussion on GEM detectors, focusing on the "NS2" technique, including design, parts, assembly, testing, and performance evaluation will be discussed. The proton has garnered attention due to discrepancies in measuring its charge radius using muonic hydrogen and electron-based methods. The 2010 muonic hydrogen measurement of the proton charge radius Rp = 0.84184(67) fm, showed a significant 7? discrepancy compared to the previously known value of Rp = 0.8775(51) fm, giving rise to the proton radius puzzle. Through simultaneous measurements of e ? p and ? ? p elastic scattering, MUSE facilitates a precise and direct comparison of the proton radius. The physics background of the proton radius puzzle, measurement techniques, the approach adopted by the MUSE experiment, its significance and the experimental setup will be discussed. Furthermore, the role of GEM detectors, along with an in-depth analysis of their data and efficiency will be discussed and evaluated.

Mohammed Prem Nazeer, Sahara↗

Soft X-ray quantum efficiency of a commercial CMOS imaging sensor

The demonstrated performance and cost-effectiveness of complementary metal-oxide-semiconductor (CMOS) sensors make them a potentially attractive option for low-cost space-based X-ray observatories. We have previously reported on the performance of a commercially available backside-illuminated Sony IMX290LLR-C CMOS sensor and found it to offer X-ray spectral resolutions comparable to the charged coupled devices (CCDs) aboard Suzaku and Chandra and to have a sufficient radiation hardness for use in low Earth orbit. Here, in this work, we report on the quantum efficiency (QE) of this sensor, an essential metric for modeling the sensitivity of an instrument as an X-ray detector. Using the Advanced Photon Source at Argonne National Laboratory, we measure the soft X-ray QE of this CMOS sensor to be 0.28 ± 0.02 at a photon energy of 490.5 eV. This energy was chosen for its proximity to the astrophysically important O VII triplet emission lines (~574 eV) studied by the HaloSat mission. Although not surpassing that of the back-illuminated CCDs aboard Suzaku and Chandra, this QE compares favorably to that of the front-illuminated CCDs aboard the same observatories and is competitive with that of the silicon drift detectors used aboard HaloSat, making it a strong candidate for use on future X-ray small satellite (SmallSat) missions.

47 OTHER INSTRUMENTATION↗

Methods for aligning a spectrometer

An example method for aligning a spectrometer is described herein. The spectrometer includes a radiation source, a crystal analyzer, and a detector that are all positioned on an instrument plane. The method includes rotating the crystal analyzer about an axis that is within the instrument plane and perpendicular to a rotation plane such that (i) a reciprocal lattice vector of the crystal analyzer is within the instrument plane or (ii) a component of the reciprocal lattice vector within the rotation plane is perpendicular to the instrument plane. An origin of the reciprocal lattice vector is located on the axis. The method further includes tilting the crystal analyzer or translating the detector such that the reciprocal lattice vector bisects a line segment that is bounded by the detector and the radiation source. Example spectrometers related to the example method are also disclosed.

Mortensen, Devon R.↗

Why would you put a flashlight in a dark matter detector?

Silicon photomultipliers (SiPMs) are solid-state, single-photon sensitive, pixelated sensors whose usage for scintillation detection has rapidly increased over the past decade. It is known that the avalanche process within the device, which renders a single photon detectable, can also generate secondary photons which may be detected by a separate device. This effect, known as external crosstalk, could potentially degrade the science goals of future xenon dark matter experiments. In this article, we measure the effect of external crosstalk in a dual-phase, liquid xenon time projection chamber fully instrumented with SiPMs. We then consider the implications for a future xenon dark matter experiment utilizing SiPMs and discuss possible solutions.

47 OTHER INSTRUMENTATION↗

Characterization of a Small-Scale Prototype Detector With Wide Dynamic Range for Time-Resolved High-Energy X-Ray Applications

We present characterization measurements of a fast-framing, wide-dynamic-range x-ray area detector intended for high-energy applications (≥20 keV photons). The MM-PAD-2.1 combines an integrating pixel front-end with a charge-removal mechanism to extend the maximum measurable signal to > 107 20-keV ph/pixel/frame. The charge-removal mechanism is dead-time-less (i.e., incoming signal continues to be integrated by the front-end while charge removal is taking place) up to an incoming photon rate of > 109 20-keV ph/pix/s. A 16×16 pixel prototype was fabricated and characterized using both laboratory and synchrotron x-ray sources, allowing for measurements from single-photon to high-flux conditions. High-flux measurements show linear performance up to ~1010 ph/s in a spot spanning approximately 2×1.5 pixels (FWHM). The onset of temporary radiation damage in the detector was observed during these measurements, manifesting as failure of the digital readout from the detector. These effects were seen to reverse after annealing at 30° C for several hours.

47 OTHER INSTRUMENTATION↗

DRiFT current mode, trigger settings and flexible detector specifications applied to scintillator arrays

MCNP radiation transport output is post-processed by DRiFT, a Detector Response Function Toolkit to simulate detailed nuclear instrumentation response. DRiFT can be used to assess the performance and potential limitations of scintillator, gas, and semiconductor detectors under a variety of simulated conditions not easily achievable in a laboratory setting. This work describes new updates in DRiFT for scintillator simulations which focus on the capability to simulate scintillators in current mode, an expansion of trigger options, and the ability to customize individual detector properties in a simulation. These improvements are designed to facilitate the ability to model large arrays of scintillator detectors with higher fidelity than was previously possible and are demonstrated in three examples. The first shows the difference between operating DRiFT in current and pulse mode. In the second example, which is intended to demonstrate deviations in individual detector performance, each detector has properties (PMT gain, optical transport, scintillation yield, etc.) that vary between detectors and are specified in DRiFT. A final example examines how DRiFT could be used to optimize digitizer settings in high rate measurements with split signals using the new common trigger option.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

High spatial resolution direct conversion amorphous selenium X-ray detectors with monolithically integrated CMOS readout

Recent progress in the field of micron-scale spatial resolution direct conversion X-ray detectors for high-energy synchrotron light sources serve applications ranging from nondestructive and noninvasive microscopy techniques which provide insight into the structure and morphology of crystals, to medical diagnostic measurement devices. Amorphous selenium ( a -Se) as a wide-bandgap thermally evaporated photoconductor exhibits ultra-low thermal generation rates for dark carriers and has been extensively used in X-ray medical imaging. Being an amorphous material, it can further be deposited over large areas at room temperatures and at substantially lower costs as compared to crystalline semiconductors. Here, to address the demands for a high-energy and high spatial resolution X-ray detector for synchrotron light source applications, we have thermally evaporated a -Se on a Mixed-Mode Pixel Array Detector (MM-PAD) Application Specific Integrated Circuit (ASIC). The ASIC format consists of 128 × 128 square pixels each 150 μm on a side. A 200 μm a -Se layer was directly deposited on the ASIC followed by a metal top electrode. The completed detector assembly was tested with 45 kV Ag and 23 kV Cu X-ray tube sources. The detector fabrication, performances, Modulation Transfer Function (MTF) measurements, and simulations are reported.

36 MATERIALS SCIENCE↗

A simple approach for characterizing the spatially varying sensitivity of microchannel plate detectors

Herein we present a simple approach to characterize the spatial variation of the gain in microchannel plate (MCP) coupled to phosphor detectors using single electron or photon hits. The technique is easy to implement and general enough to be extended to other kinds of detectors. We demonstrate the efficacy of the approach on both laboratory and Monte Carlo generated datasets. Furthermore, we use the approach to measure the variation in gain over time as the MCP is exposed to an increasing number of electrons.

47 OTHER INSTRUMENTATION↗

Front-End Design for SiPM-Based Monolithic Neutron Double Scatter Imagers

Neutron double scatter imaging exploits the kinematics of neutron elastic scattering to enable emission imaging of neutron sources. Due to the relatively low coincidence detection efficiency of fast neutrons in organic scintillator arrays, imaging efficiency for double scatter cameras can also be low. One method to realize significant gains in neutron coincidence detection efficiency is to develop neutron double scatter detectors which employ monolithic blocks of organic scintillator, instrumented with photosensor arrays on multiple faces to enable 3D position and multi-interaction time pickoff. Silicon photomultipliers (SiPMs) have several advantageous characteristics for this approach, including high photon detection efficiency (PDE), good single photon time resolution (SPTR), high gain that translates to single photon counting capabilities, and ability to be tiled into large arrays with high packing fraction and photosensitive area fill factor. However, they also have a tradeoff in high uncorrelated and correlated noise rates (dark counts from thermionic emissions and optical photon crosstalk generated during avalanche) which may complicate event positioning algorithms. We have evaluated the noise characteristics and SPTR of Hamamatsu S13360-6075 SiPMs with low noise, fast electronic readout for integration into a monolithic neutron scatter camera prototype. The sensors and electronic readout were implemented in a small-scale prototype detector in order to estimate expected noise performance for a monolithic neutron scatter camera and perform proof-of-concept measurements for scintillation photon counting and three-dimensional event positioning.

47 OTHER INSTRUMENTATION↗

High Data Rate Detector for Neutron Reflectometer

Neutron reflectometers are a class of instruments that employ neutron diffraction for measuring the structure of thin films. The technique provides valuable information over a wide variety of scientific and technological applications including chemical aggregation, polymer and surfactant adsorption, structure of thin film magnetic systems, biological membranes, etc. Such instruments are considered to be one of the most important in the neutron science field. Newer facilities place growing demands on the count rate capability of the specialized neutron detectors required. Proportional Technologies completed the Phase I effort successfully with a fully operational prototype detector built at PTI and tested at the CG1A neutron beam of the High Flux Isotope Reactor (HFIR, Oak Ridge, TN). The prototype incorporated 3 panels of 14 copper-walled cells each (total of 42 cells), each lined with 1.3 μm of 10B4C. The detector was tested for efficiency, spatial resolution, count rate linearity, uniformity, overlap and scatter. Testing revealed stable operation, uniform response across cells, and successful resolution of individual cells. The maximum count rate tested in the 3 panels combined was 590 kHz, limited by a deadtime of about 1 μs in the digital electronics. The local rate measured in a single cell showed no deadtime losses up to 810 cps/mm2, indicating that a rate of 20 Mhz can be supported in the 308-cell detector planned for Phase II.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗