Limits on the antiproton/proton ratio in the cosmic radiation from 100 MeV to 1580 MeV

A search for antiprotons (p-bars) in the cosmic radiation with energies below 1580 MeV at the top of the atmosphere was performed using the PBAR balloon-borne magnetic spectrometer. No antiprotons were observed in 124,000 proton events. For the energy interval 100-640 MeV, an upper limit is reported to the p-bar/p ratio of 2.8 x 10 to the -5th at the top of the atmosphere, after correcting for instrumental efficiencies and contributions from secondary particles. No antiproton was observed in the energy interval 640-1580 MeV, which yields an upper limit to the p-bar/p ratio of 6.1 x 10. By combining both data sets, the limits on the p-bar/p ratio can be improved to 2.0 x 10 to the -5th. The detector performance and instrumental efficiencies of the individual detector components are discussed. A detail Monte Carlo calculation was used to evaluate the instrumental efficiency for both antiprotons and protons as a function of momentum.

Salamon, M. H.↗

High-Q Superconducting Lumped-Element Resonators for Low-Mass Axion Searches

Low-frequency superconducting lumped-element resonators have recently attracted significant attention in the context of axion dark matter searches. Here we present the design and implementation of a fixed-frequency superconducting resonator operating near $250~\mathrm{kHz}$, possessing an inductor volume of $\sim 1$ liter and achieving an unloaded quality factor $Q \approx 2.1\times10^{6}$. This resonator represents a significant improvement over the state of the art and informs the design of searches for low-mass axions.

FOS: Physical sciences↗

SQUID Readout of a High-$Q$ Superconducting $LC$ Resonator

We demonstrate the readout of a superconducting $LC$ resonator, with $Q \approx 2 \times 10^{6}$ at approximately 250 kHz, using a dc SQUID followed by a SQUID series-array amplifier readout chain. We find that $Q$ depends on the SQUID flux-bias point, increasing near the shallow-slope point of the SQUID modulation curve and decreasing near the steep-slope point, consistent with the previously observed SQUID damping effects. From this variation, we infer the SQUID effective input impedance. We further infer the effective temperature of the resonator circuit from the resonance peak in the noise spectrum and show that it also depends on the SQUID flux-bias point, suggesting a possible contribution from SQUID back-action noise. This system provides a working prototype for future experiments based on lumped-element resonators with SQUID readout, in particular low-mass axion searches within the DMRadio program.

FOS: Physical sciences↗

New screening methodology to select low outgassing materials for cold, spaceborne optical instruments

Standardized techniques for outgassing tests are developed and set forth for use in the screening of materials for aerospace instruments with cooled sensors, optics, and/or detectors. Materials for optical instruments are discussed in terms of molecular outgassing, and material-outgassing test results are presented which relate to several test conditions. The existing outgassing standard is found to be inadequate, and revised outgassing standards related to four application levels are given. The test protocols are designed for the development of materials for optical instruments that operate in environments with temperatures below 20 C. Consideration is also given to potential molecular contamination in the space environment and to outgas screening of instruments with a variety of sensor/optics/detector temperatures. The standards are designed for use with existing outgassing-test data as well as contamination analyses relating to the instrument being tested.

O'Donnell, T.↗

Optical and Detector Design of the Ocean Color Instrument for the NASA Pace Mission

The Ocean Color Instrument (OCI) on NASA’s Plankton, Aerosol, Cloud, ocean Ecosystem mission is a hyperspectral imager with high SNR, precision and dynamic range, and with a very low striping artifact level in the 342-887 nm wavelength range with a spectral resolution of 5 nm in 2.5 nm steps, providing a significant technological advancement over previous ocean imagers. To achieve this, OCI is designed with specialized optical imaging and opto-electronic detection systems that push the boundaries of several state-of-the-art technologies. This paper provides an overview of these systems together with their achieved performances and discussions of their key design challenges.

Remote sensing↗

Optical and Detector Design of the Ocean Color Instrument for the NASA Pace Mission

The Ocean Color Instrument (OCI) on NASA’s Plankton, Aerosol, Cloud, ocean Ecosystem mission is a hyperspectral imager with high SNR, precision and dynamic range, and with a very low striping artifact level in the 342-887 nm wavelength range with a spectral resolution of 5 nm in 2.5 nm steps, providing a significant technological advancement over previous ocean imagers. To achieve this, OCI is designed with specialized optical imaging and opto-electronic detection systems that push the boundaries of several state-of-the-art technologies. This paper provides an overview of these systems together with their achieved performances and discussions of their key design challenges.

Remote sensing↗

In-flight performance of the XRISM/Resolve detector system

The Resolve instrument was launched on board the XRISM observatory in early September 2023. The Resolve spectrometer is based on a high-sensitivity X-ray calorimeter detector system (DS) that has been successfully deployed in many ground and sub-orbital spectrometers. However, the Resolve instrument is the first long-term implementation in space. The instrument will provide essential diagnostics for nearly every class of X-ray emitting objects, from galactic supernova remnants to the outskirts of galaxy clusters, without degradation for spatially extended objects. The Resolve DS consists of a 36-pixel microcalorimeter array operated at a heat sink temperature of 50 mK. In pre-flight testing, the DS demonstrated a resolving power of better than 1300 at 6 keV with a simultaneous bandpass from below 0.3 keV to above 12 keV and a timing precision better than 100μs. An anti-coincidence detector placed directly behind the microcalorimeter array effectively suppresses background. The detector energy-resolution budget included terms for interference from the Resolve cooling system and the spacecraft. Additional terms for energy-scale stability, on-orbit effects, and use of mid-grade events were also included, predicting an end-of-life, on-orbit performance for high- and mid-resolution grade events that meet the requirement of 7 eV FWHM at 6 keV. Here, we discuss the actual on-orbit performance of the Resolve DS and compare this with the performance in pre-flight testing, on-orbit predictions, and the almost identical Hitomi/SXS instrument. We will also discuss the on-orbit gain stability, an assessment of on-orbit interference, and measurements of the on-orbit background.

Astronomy and AstroPhysics↗

Study of mass flow distribution and chemical composition of comets from solar induced X-ray fluorescence

The expected performance of an X-ray detector as an instrument aboard a mission to a comet was evaluated. The functions of the detector are both nondispersive analysis of chemical composition and measurement of mass flow from the comet nucleus. Measurements are to be carried out at a distance from the comet. The approach distances considered are of the order of 1000 km and 100 km. A new type of X-ray detector, a proportional scintillation detector, is considered as an X-ray counter for nondispersive elemental analysis.

Gorenstein, P.↗

Technical Aspects of the Space Telescope Imaging Spectrograph Repair (STIS-R)

In August 2004, the Hubble Space Telescope (HST) Space Telescope Imaging Spectrograph (STIS) ceased operation, due to a failure in the Side 2 Low Voltage Power Supply (LVPS2). The LVPS2 provided power to the entire instrument, including all detectors and mechanisms. The failure precluded movement of any STIS mechanism, leaving the instrument fully shuttered. The fault analysis team concluded that by replacing a board containing a new LVPS2 power supply, STIS could be brought back to full functionality. During Servicing Mission 4 (SM4), STIS-R will replace this board. STIS-R will restore full function of the instrument with one of the two redundant sides of the instrument.

Rinehart, Stephen A.↗

A balloon measurement of the isotopic composition of galactic cosmic ray boron, carbon and nitrogen

The isotopic compositions of galactic cosmic ray boron, carbon, and nitrogen were measured at energies near 300 MeV amu, using a balloon-borne instrument at an atmospheric depth of approximately 5 g/sq cm. The calibrations of the detectors comprising the instrument are described. The saturation properties of the cesium iodide scintillators used for measurement of particle energy are studied in the context of analyzing the data for mass. The achieved rms mass resolution varies from approximately 0.3 amu at boron to approximately 0.5 amu at nitrogen, consistent with a theoretical analysis of the contributing factors. Corrected for detector interactions and the effects of the residual atmosphere the results are B-10/B=0.33 (+0.17, -0.11), C-13/C=0.06 (+0.13, -0.11), and N-15/N=0.42 (+0.19, -0.17). A model of galactic propagation and solar modulation is described. Assuming a cosmic ray source composition of solar-like isotopic abundances, the model predicts abundances near Earth consistent with the measurements.

Zumberge, J. F.↗

The EBIT Calorimeter Spectrometer: A New, Permanent User Facility at the LLNL EBIT

The EBIT Calorimeter Spectrometer (ECS) has recently been completed and is currently being installed at the EBIT facility at the Lawrence Livermore National Laboratory. The ECS will replace the smaller XRS/EBIT spectrometer that has been in almost continuous operation since 2000. The XRS/EBIT was based on a spare laboratory cryostat and an engineering model detector system from the Suzaku/XRS observatory. The new ECS spectrometer was built from the ground up to be a low maintenance, high performance microcalorimeter spectrometer with 4 eV resolution at 6 keV, 32 detector channels, 10 us event timing, and capable of uninterrupted acquisition sessions of over 70 hours at 50 mK. The XRSIEBIT program has been extremely successful, producing over two-dozen refereed publications on topics such as laboratory astrophysics, atomic physics, nuclear physics, and calibration of the spectrometers for the National Ignition Facility, with many more publications in preparation. The ECS spectrometer will continue this work into the future with improved spectral resolution, integration times, and ease-of-use. We designed the ECS instrument with TES detectors in mind by using the same highly successful magnetic shielding as our laboratory TES cryostats. This design will lead to a future TES instrument at the LLNL EBIT. This proposed future instrument would include a hybrid detector system with 0.8 eV resolution in the band from 0.1-1.0 keV, 2 eV from 0.1-10 keV, and 30 eV from 0.5-100 keV, with high quantum efficiency in each band. Here we discuss the legacy of the XRS/EBIT program, the performance of the new ECS spectrometer, and plans for a future TES spectrometer.

Porter, S.↗

Prototype V-Groove Radiator Heat Shield

Report describes design, fabrication, and testing of heat radiator equipped with multi-V-groove radiator heat shield. Device compact, efficient structure which removes heat from infrared detectors, gamma-ray detectors, and similar instruments aboard Mars Observer spacecraft and radiates heat into outer space. Designed to maintain detector for gamma-ray spectrometer at temperature of 80 K in cold vacuum under heat load of 80 mW. Prototype made of aluminum, though production shields made of aluminized sheets of polyethylene terephthalate.

Petrick, S. Walter↗

The Observed On-Orbit Background of the ACIS Instrument of the Chandra X-Ray Observatory

We have analyzed calibration data acquired during the Orbital Activation and Checkout (OAC) phase of the Chandra X-ray Observatory (CXO) mission in order to characterize the background of the Advanced CCD Imaging Spectrometer (ACIS) produced by charged particles and non-cosmic x-rays. The ACIS instrument contains eight Front-Illuminated (FI) CCDs and two Back-Illuminated (BI) CCDs. The FI and BI CCDs exhibit dramatically different responses to enhancements in the particle flux. The FI CCDs show relatively little increase in the overall count rate, typical increases are 1-3 counts/s; the BI CCDs show large excursions to as high as 100 counts/s. The directions of these intervals of enhanced background are highly variable ranging from 100 s to 5000 s. The spatial distribution of these background events is relatively flat across the detectors. The spectral distribution can be characterized by a simple power law. The events produce morphologies which are similar to cosmic x-ray events, so that morphology alone cannot be used as a rejection criterion. We explore the correlation of these times of high background with the data from Chandra's on-board radiation monitor, the EPHIN (Electron, Proton, Helium Instrument particle detector) instrument and archival data from the Advanced Composition Explorer (ACE) satellite. We discuss strategies for observers to identify and exclude times of high background and to model and subtract the background events from their data.

Plucinsky, Paul P.↗

Radiation Effects in CdZnTe Gamma-Ray Detectors Produced by 199 MeV Protons

Many future space missions will use Cadmium Sinc Telluride (CdZnTe) gamma-ray detectors because their operation at room temperature makes compact, lightweight detector systems possible. Even though instruments for space using CdZnTe detectors have already been built, the effect of the high-energy particle space environment on these detectors has not been measured. To determine the effect of energetic charged particles on these detectors, we have bombarded seveal CdZnTe detectors with 199 MeV protons at the Indiana University Cyclotron Facility.

radiation↗

Maximum Likelihood Estimation of Spectra Information from Multiple Independent Astrophysics Data Sets

The Maximum Likelihood (ML) statistical theory required to estimate spectra information from an arbitrary number of astrophysics data sets produced by vastly different science instruments is developed in this paper. This theory and its successful implementation will facilitate the interpretation of spectral information from multiple astrophysics missions and thereby permit the derivation of superior spectral information based on the combination of data sets. The procedure is of significant value to both existing data sets and those to be produced by future astrophysics missions consisting of two or more detectors by allowing instrument developers to optimize each detector's design parameters through simulation studies in order to design and build complementary detectors that will maximize the precision with which the science objectives may be obtained. The benefits of this ML theory and its application is measured in terms of the reduction of the statistical errors (standard deviations) of the spectra information using the multiple data sets in concert as compared to the statistical errors of the spectra information when the data sets are considered separately, as well as any biases resulting from poor statistics in one or more of the individual data sets that might be reduced when the data sets are combined.

Howell, Leonard W., Jr.↗

Neutrino Beam Monitoring

Accelerator facilities produce neutrino beams from meson decays in a decay volume. Experiments measure event rates that depend on flux, cross sections, and detector response, so the flux is predicted using hadron production and beamline modeling and constrained by beam instrumentation, since near detectors alone cannot separate flux from cross section. Proton, hadron, and muon monitors can track the parent particle distributions and beam conditions, providing the inputs needed for flux predictions in long-baseline experiments such as NOvA, T2K, and DUNE. This talk reviews how beam monitors are used in practice to understand neutrino flux. Proton beam monitors tell where the beam hits the target and how stable it is. Farther downstream, hadron and muon monitors sample particles produced in meson decays. Because those muons come from the same parents as the neutrinos, their profiles reveal focusing, alignment shifts, and other changes in the beam, and they are routinely used to detect problems and guide flux predictions. The muon information can be used more quantitatively; for example, to infer the parent meson phase space, and fast radiation-hard timing detectors can add sensitivity to the momentum dependence of the focusing. These developments show both how tightly beam measurements can constrain the flux and where the current limits still lie. These approaches complement monitored-beam concepts, in which the decay region is instrumented to detect charged leptons from meson decays and to measure the neutrino flux directly.

Ganguly, Sudeshna [Fermilab] (ORCID:00000003163482↗