Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “InC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Cost Model for Pumped Storage Hydropower Geomembrane Lining Systems

The Cost Model for Pumped Storage Hydropower Geomembrane Lining Systems offers an approximation of geomembrane lining system costs for pumped storage hydropower (PSH) reservoirs. Geomembrane lining systems have been used around the world for over 60 years for the construction of dams and reservoirs. Although geomembrane lining systems have found widespread use in the construction of canals and waste containment systems, they have not been utilized in the construction of new PSH facilities in the United States since the Mount Elbert PSH powerplant in Colorado. For this reason, PSH developers in the United States expressed the need for a tool that would allow them to estimate the costs of geomembrane lining systems for their PSH projects. To meet this need, the Cost Model for Pumped Storage Hydropower Geomembrane Lining Systems was developed by Oak Ridge National Laboratory with support from Argonne National Laboratory and Stantec, Inc. This Cost Model will enable PSH developers to develop a preliminary estimate of the cost of geomembrane lining systems and to better understand different reservoir lining options and their cost and performance characteristics, thus enabling them to make informed decisions related to preferred reservoir lining systems for their PSH projects.

DeNeale, Scott [Oak Ridge National Laboratory (ORN↗

Aerodynamic diameter particle size distributions for the AGINSGP experiment

Aerodynamic size distributions were collected by the APS 3321 (TSI Inc.) in the guest instrument facility at ARM’s Southern Great Plains site, during the AGINSGP field campaign. The APS accelerates particle through an orifice and uses two overlapping laser beams to measure the time-of-flights for particles. The aerodynamic diameter controls how quickly a particle will accelerate, with larger particles accelerating more slowly due to their greater inertia. The APS measures particle size distributions from 0.542 to 19.81 µm. Size distributions are averaged to their 1 minute averages. Air was drawn into the GIF through custom aluminum stack inlets (6” inner diameter) attached vertically to the outer GIF wall and the GIF outside platform. A blower pulled air through the stacks at a velocity of 1 m/s. Aerosol instruments subsampled via wall ports, through either 3/8” or 1/4" copper lines, depending on sample flow of the instrument.

54 ENVIRONMENTAL SCIENCES↗

Listening to U.S. Farmers: Barriers and opportunities for growing more biomass

In 2025, bioenergy researchers from Oak Ridge National Laboratory and Idaho National Laboratory held a series of discussions with farmers in Illinois, Tennessee, Alabama, Kansas, and Colorado to get an unfiltered look at the future of biomass resources from the U.S. agricultural sector. Coordinated by Sustainable Oils, Inc., with additional facilitation from the HudsonAlpha Institute for Biotechnology, the meetings were supported by the U.S. Department of Energy’s Bioenergy Technologies Office (DOE BETO).

Parish, Esther [Oak Ridge National Laboratory (ORN↗

A comparative experimental study of the hygroscopic and mechanical behaviors of electrospun nanofiber membranes and solution–cast films of polybenzimidazole

This article reports a comparative experimental study of the hygroscopic and mechanical behaviors of electrospun polybenzimidazole (PBI) nanofiber membranes and solution-cast PBI films. As-electrospun nonwoven PBI nanofiber mats (with the nanofiber diameter of ~250 nm) were heat-pressed under controlled temperature, pressure and duration for the study; lab-made solution-cast PBI films and commercially available PBI films (the PBI Performance Product Inc., Charlotte, NC) were used as the control samples. Thermogravimetric and microtensile tests were utilized to characterize the hygroscopic (moisture absorption) and mechanical properties of the PBI nanofiber membranes at varying heat-pressing conditions, which were further compared to those of solution-cast PBI films. Experimental results indicated that the PBI nanofiber membranes carried slightly higher thermal stability and less hygroscopic properties than those of solution-cast PBI films. In addition, heat-pressing conditions significantly influenced the mechanical properties of the resulting PBI nanofiber membranes. The stiffness and tensile strength increase with increasing either the heat-pressing pressure or duration, and relevant mechanisms were explored. Here, the present study provides a rational understanding of the hygroscopic and mechanical behaviors of electrospun PBI nanofiber membranes and solution-cast PBI films that are beneficial to their reliable cutting-edge applications in high-temperature filtration, polymer electrolyte membranes (PEMs), etc.

25 ENERGY STORAGE↗

Benchmark Dose Analysis of DNA Damage Biomarker Responses Provides Compound Potency and Adverse Outcome Pathway Information for the Topoisomerase II Inhibitor Class of Compounds

Genetic toxicology data have traditionally been utilized for hazard identification to provide a binary call for a compound's risk. Recent advances in the scientific field, especially with the development of high‐throughput methods to quantify DNA damage, have influenced a change of approach in genotoxicity assessment. The in vitro MultiFlow® DNA Damage Assay is one such method which multiplexes γH2AX, p53, phospho‐histone H3 biomarkers into a single‐flow cytometric analysis (Bryce et al., [2016]: Environ Mol Mutagen 57:546–558). This assay was used to study human TK6 cells exposed to each of eight topoisomerase II poisons for 4 and 24 hr. Using PROAST v65.5, the Benchmark Dose approach was applied to the resulting flow cytometric datasets. With “compound” serving as covariate, all eight compounds were combined into a single analysis, per time point and endpoint. The resulting 90% confidence intervals, plotted in Log scale, were considered as the potency rank for the eight compounds. The in vitro MultiFlow data showed a maximum confidence interval span of 1Log, which indicates data of good quality. Patterns observed in the compound potency rank were scrutinized by using the expert rule‐based software program Derek Nexus, developed by Lhasa Limited. Compound sub‐classification and structural alerts were considered contributory to the potencies observed for the topoisomerase II poisons studied herein. The Topo II poison Adverse Outcome Pathway was evaluated with MultiFlow endpoints serving as Key Events. The step‐wise approach described herein can be considered as a foundation for risk assessment of compounds within a specific mode of action of interest. Environ. Mol. Mutagen. 2020. © 2020 Wiley Periodicals, Inc.

Wheeldon, Ryan P.↗

Osteoporosis Treatments Affect Bone Matrix Maturation in a Rat Model of Induced Cortical Remodeling

ABSTRACT To test how osteoporosis drugs affect bone matrix maturation during cortical bone remodeling, 72 pregnant rats were switched from a 0.4% to a 0.01% calcium diet at parturition for a 23‐day lactation period. At weaning, eight dams were sacrificed to establish baseline values, while the remaining dams were returned to 0.4% calcium and treated with vehicle (saline), sodium fluoride (NaF), zoledronic acid (ZA), or sclerostin antibody (Scl‐Ab) for either 7 or 28 days (eight animals per group per time point). Femora were examined by μCT, dynamic histomorphometry, Fourier transform infrared imaging, and three‐point bending of notched specimens. Cortical porosity decreased in all groups from baseline to day 28. Intracortical mineralizing surface (MS/BS) and mineral apposition rate (MAR), as well as the mineral‐to‐matrix ratio were unaffected by treatment, but intracortical crystallinity was increased in the ZA group at day 10 compared with vehicle. Cortical area increased in all groups over 28 days mainly because of an addition of bone at the endocortical surface. Endocortical MS/BS did not vary among the groups, but endocortical MAR was suppressed in the NaF group at day 2 and elevated in the Scl‐Ab group at day 4 compared with vehicle. Endocortical mineral‐to‐matrix ratio was increased at days 5 and 10 following NaF treatment and endocortical crystallinity was increased at day 5 following ZA treatment compared with vehicle. Fracture toughness did not differ among the groups. Thus, the treatments affected matrix maturation more strongly at the endocortical then intracortical envelope. In this model of induced remodeling, the bone formation phase is synchronized at multiple sites, facilitating study of the effects of drugs or other bone‐targeting agents on matrix maturation independent of their effects on the initiation of remodeling. © 2020 The Authors. JBMR Plus published by Wiley Periodicals, Inc. on behalf of American Society for Bone and Mineral Research.

59 BASIC BIOLOGICAL SCIENCES↗

Perimatrix of middle ear cholesteatoma: A granulation tissue with a specific transcriptomic signature

Objectives/Hypothesis: To establish comprehensive transcriptomic profiles of cholesteatoma perimatrix tissue and granulation tissue from chronic otitis media (COM) that did not develop cholesteatoma, which can indicate molecular pathways involved in the cholesteatoma perimatrix pathology and invasiveness. Study Design: Retrospective Case Series. Methods: Transcriptome data were obtained from cholesteatoma perimatrix tissue and COM granulation tissue by an Illumina iScan microarray. Differentially expressed genes (DEGs) were subsequently analyzed using both bioinformatical functional annotation and network analysis. Expression of candidate genes (MMP9 and LCN2) was validated by quantitative reverse transcription-polymerase chain reaction (qRT-PCR) on a larger group of samples. Results: Analysis of the transcriptome led to the identification of 169 differentially expressed genes between investigated tissues. Bioinformatic analysis suggested that most significant biological processes involving DEGs were previously described in cholesteatoma pathology. Network analysis identified ERBB2, TFAP2A, and TP63 as major hubs of the DEGs molecular network. Furthermore, it was observed that the cellular component most significantly enriched in DEGs was extracellular space containing 47 DEGs. Using qRT-PCR, it was confirmed that mRNA levels of the major extracellular hub (MMP9) are increased, whereas its interacting molecule (LCN2) mRNA levels were decreased in cholesteatoma perimatrix tissue compared to COM granulation tissue. Conclusions: The current study approach offers an overall look at molecular mechanisms that describe the cholesteatoma entity by focusing exclusively on the perimatrix processes in comparison to COM granulation tissue. The observed differences in gene expression between cholesteatoma perimatrix and COM granulation tissue could suggest novel markers potentially influenced by the perimatrix–matrix molecular interplay, which is not present in COM without cholesteatoma. Level of Evidence: NA. Laryngoscope, 130:E220–E227, 2020. © 2019 The American Laryngological, Rhinological and Otological Society, Inc.

60 APPLIED LIFE SCIENCES↗

Erratum to: Soft- and reactive landing of ions onto surfaces: concepts and applications

Soft- and reactive landing of mass-selected ions is gaining attention as a promising approach for the precisely-controlled preparation of materials on surfaces that are not amenable to deposition using conventional methods. A broad range of ionization sources and mass filters are available that make ion soft-landing a versatile tool for surface modification using beams of hyperthermal (<100?eV) ions. The ability to select the mass-to-charge ratio of the ion, its kinetic energy and charge state, along with precise control of the size, shape, and position of the ion beam on the deposition target distinguishes ion soft landing from other surface modification techniques. Soft- and reactive landing have been used to prepare interfaces for practical applications as well as precisely-defined model surfaces for fundamental investigations in chemistry, physics, and materials science. For instance, soft- and reactive landing have been applied to study the surface chemistry of ions isolated in the gas-phase, prepare arrays of proteins for high-throughput biological screening, produce novel carbon-based and polymer materials, enrich the secondary structure of peptides and the chirality of organic molecules, immobilize electrochemically-active proteins and organometallics on electrodes, create thin films of complex molecules, and immobilize catalytically active organometallics as well as ligated metal clusters. In addition, soft landing has enabled investigation of the size-dependent behavior of bare metal clusters in the critical subnanometer size regime where chemical and physical properties do not scale predictably with size. The morphology, aggregation, and immobilization of larger bare metal nanoparticles, which are directly relevant to the design of catalysts as well as improved memory and electronic devices, have also been studied using ion soft landing. This review article begins in section 1 with a brief introduction to the existing applications of ion soft- and reactive landing. Section 2 provides an overview of the ionization sources and mass filters that have been used to date for soft landing of mass-selected ions. A discussion of the competing processes that occur during ion deposition as well as the types of ions and surfaces that have been investigated follows in section 3. Section 4 discusses the physical phenomena that occur during and after ion soft landing, including retention and reduction of ionic charge along with factors that impact the efficiency of ion deposition. The influence of soft landing on the secondary structure and biological activity of complex ions is addressed in section 5. Lastly, an overview of the structure and mobility as well as the catalytic, optical, magnetic, and redox properties of bare ionic clusters and nanoparticles deposited onto surfaces is presented in section 6. © 2015 Wiley Periodicals, Inc. Mass Spec Rev 35:439–479, 2016.

Johnson, Grant E.↗

Positron annihilation lifetime spectroscopy study of polyvinylpyrrolidone‐added polyvinylidene fluoride membranes: Investigation of free volume and permeation relationships

ABSTRACT Polyvinylidene fluoride (PVDF) membranes were prepared via the phase inversion method from casting solutions containing PVDF, dimethylformamide (DMF), and polyvinylpyrrolidone (PVP) as pore former. PVP was used in the casting solution in a range of 0–5 wt % and extracted. The effect on membranes of using PVP in the casting process was analyzed by X‐ray diffraction, differential scanning calorimetry, scanning electron microscopy, viscosity, and water permeability techniques. With an increase of PVP from 0 to 5 wt %, the PVDF casting solution viscosities increased from 858 to 1148 cP; the resulting PVDF membrane thickness increased; and the crystallinity of PVDF membranes decreased from 40.0 to 33.3%, which indicates that the addition of PVP inhibits the degree of crystallization in the PVDF membranes. SEM results revealed the shape and size of macropores in the membranes; these macropores changed after PVP addition to the casting solutions. The impact of structural changes on free‐volume properties was evaluated using positron annihilation lifetime spectroscopy (PALS) studies. PALS analysis indicated no effect on the average radius (~3.4 Å) of membrane free‐volume holes from the addition of PVP to the casting solution. However, the percentage of o ‐Ps pick‐off annihilation intensity, I 3 , increased from 1.7 to 5.1% with increased PVP content. Further, increasing the PVP content from 0.5 to 5% resulted in an increased final pure water permeability flux. For instance, the 210 min flux for a 14% PVDF + 0.5% PVP membrane was found to be 3.3 times greater than a control membrane having the same PVDF concentration. © 2020 Wiley Periodicals, Inc. J. Polym. Sci. 2020 , 58 , 589–598

Eren, Bilge↗

Directed energy system technology for the control of soilborne fungal pathogens and plant‐parasitic nematodes

Abstract BACKGROUND It is challenging to manage soilborne pathogens and plant‐parasitic nematodes using sustainable practices. Here, we evaluated a novel energy application system, Directed Energy System (DES). This system generates pulses of energy capable of impacting selected biological organisms. The oomycete Phytophthora cinnamomi , the fungus Verticillium dahliae , and the plant‐parasitic nematodes Meloidogyne hapla and Globodera ellingtonae were added to soil. Then DES‐generated energy was applied to soil and impacts on target organisms were determined. RESULTS DES applied at 20, 40 and 70 J cm −3 to P. cinnamomi and V. dahliae resulted in ≥50% and 92% reductions (respectively) of propagules per gram of soil in comparison to the untreated control. There was a significant reduction of M. hapla eggs per gram of host tomato root between the untreated control, and 2.2, 13 and 25 J cm −3 DES dosages applied pre‐ or post‐planting. Additionally, an 84% reduction in hatch from G. ellingtonae encysted eggs after treatment with 70 J cm −3 DES was observed. The dosages ranged from 40 or 80V mm −1 for nematodes to 200 V mm −1 for fungi. CONCLUSION DES‐generated energy reduced survival of the soilborne pathogens P. cinnamomi and V. dahlia, and the plant‐parasitic nematodes M. hapla and G. ellingtonae . The application of this technology to a field setting remains to be considered. Published 2020. This article is a U.S. Government work and is in the public domain in the USA. Pest Management Science published by Wiley Periodicals, Inc. on behalf of © 2020 Society of Chemical Industry.

Riga, Ekaterini↗

Estimating and Evaluating Roughness Length and Displacement Height in Heterogeneous Urban Environments

The roughness length (z 0 ) and displacement height (z d ) are essential surface-layer parameters in numerical models (e.g., weather, climate, wall-modeled LES, etc.). This work evaluates the consistency of z 0 and z d estimates from morphometric and anemometric methods using data from two eddy-covariance flux towers (AmeriFlux US-INg and US-INc) in Indianapolis, IN. Results show inconsistencies in estimated z 0 and z d values depending on the chosen method. The two evaluated anemometric methods estimate non-physical values of z d when compared to roughness elements surrounding both towers. Additionally, predictions of mean wind speed using surface-layer similarity theory with morphometric estimates exhibit a bias during near-neutral and stable conditions relative to observations. The overestimation of mean wind speed by surface layer similarity theory is consistent with previous observational and modeling studies in urban areas, suggesting that the application of similarity theories to urban environments may have limitations. Differentiation of vegetation from built structures appears to impact morphometric z 0 and z d estimates, particularly where vegetation is abundant; however, it has little impact on correcting biases in the similarity theory. Specifically, we find that existing similarity theories using morphometric estimates underestimate integral velocity and length scales, and the degree of underestimation depends on the stability conditions. Accounting for the degree of anisotropy in surface-layer turbulence helps reduce the biases between similarity theories and observations during unstable conditions, but not in near-neutral cases. Future work is needed to identify the cause of such biases for near-neutral conditions.

Aerodynamic roughness length↗

Recent Developments of Commercially Fabricated Horn Antenna-Coupled Transition-Edge Sensor Bolometer Detectors for Next-Generation Cosmic Microwave Background Polarimetry Experiments

Here we report on the successful fabrication of orthomode transducer-coupled transition-edge sensor (TES) bolometer arrays for cosmic microwave background (CMB) polarimetry experiments with the superconductor electronics fabrication facility at SEEQC Inc. Commercial microfabrication foundry could provide increase in detector fabrication throughput for a next-generation CMB experiment, CMB-S4, that would deploy approximately one order of magnitude more detectors than current CMB experiments. We also developed TES bolometers with two TESs in series that have two different superconducting temperatures (Tc) using a superconducting proximity effect between niobium (Nb) and aluminum-manganese (AlMn) alloy. We will discuss the motivation, design considerations, fabrication processes, test results, and how industrial detector fabrication could be a path to fabricate hundreds of detector wafers for future CMB polarimetry experiments and other experiments that require TESs and superconducting RF circuits.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

In situ and ex situ studies of anomalous eutectic formation in undercooled Ni–Sn alloys

Anomalous eutectic formation in undercooled Ni-Sn alloys was investigated by in situ X-ray diffraction and ex situ remelting and annealing experiments. Dynamic recrystallization and partial remelting of primary solids followed by repeated nucleation and growth of eutectic grains in the mushy zone were revealed by time-resolved X-ray diffraction. Ex situ experiments demonstrated that partial remelting of near-equilibrium solidified alloys of eutectic or near-eutectic composition can convert regular lamellar eutectic into anomalous eutectic, whereas high-temperature annealing of splat-quenched alloys of similar composition can convert eutectic or two-phase dendrites into anomalous eutectic. It is concluded that compared to ripening in solid-states, partial remelting of eutectic or two-phase dendrites in a mushy zone provides a more realistic mechanism for anomalous eutectic formation in undercooled solidification of Ni-Sn eutectic alloys. (C) 2020 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

Crystal growth↗

Characterising Ion-Irradiated FeCr: Hardness, Thermal Diffusivity and Lattice Strain

Ion-irradiated FeCr alloys are useful for understanding and predicting neutron damage in the structural steels of future nuclear reactors. Previous studies have largely focused on the structure of irradiation induced defects, probed by transmission electron microscopy (TEM), as well as changes in mechanical properties. Across these studies, a wide range of irradiation conditions has been employed on samples with different processing histories, which complicates the analysis of the relationship between defect structures and material properties. Furthermore, key properties, such as irradiation-induced changes in thermal transport and lattice strain, are little explored. Here we present a systematic study of Fe3Cr, Fe5Cr and Fe10Cr binary alloys implanted with 20 MeV Fe3+ ions to nominal doses of 0.01 dpa and 0.1 dpa at room temperature. Nanoindentation, transient grating spectroscopy (TGS) and X-ray micro-beam Laue diffraction were used to study the changes in hardness, thermal diffusivity and strain in the material as a function of damage and Cr content. Our results suggest that Cr leads to an increased retention of irradiation-induced defects, causing substantial changes in hardness and lattice strain. However, thermal diffusivity varies little with increasing damage and instead degrades significantly with increasing Cr content in the material. We find significant lattice strains even in samples exposed to a nominal displacement damage of 0.01 dpa. The defect density predicted from the lattice strain measurements is significantly higher than that observed in previous TEM studies, suggesting that TEM may not fully capture the irradiation-induced defect population. (C) 2020 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

FeCr alloys↗

In-situ synchrotron X-ray micro-diffraction investigation of ultra-low-strain deformation microstructure in laminated Ti-Al composites

An ultra-low-strain deformation microstructure was revealed for the first time non-destructively in the bulk interior of an annealed laminated Ti-Al composite-in the "fully recrystallized" Al layer-by a synchrotron-based micro-diffraction technique, namely differential aperture X-ray microscopy (DAXM), through real space mapping with a very high angular resolution (0.01 degrees). This ultra-low-strain deformation microstructure was found to result from the thermal stress, induced during cooling after annealing, due to the different coefficients of thermal expansion for the Ti and Al layers. The annealed sample was further tensile deformed to a strain of 1.66% and followed by in situ DAXM and analyzed by various misorientation mapping methods. The results pointed to the important effects of the initial microstructure and the interface constraint, as well as the grain size and crystal orientation, on the plastic deformation. A gradient in dislocation density from the layer interface to the center was found in the Al layer of the annealed sample, and this gradient increased slightly during tensile deformation. The variation of the dislocation density was further discussed based on the activation and interaction of dislocations in grains of different sizes and orientations during plastic deformation. The findings of this study provided valuable insights in understanding the constraint effect of the laminated metal composite and the design of novel composite materials. (c) 2020 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

Crystallographic orientation↗

Multi-layer anodes for high-current applications

In this work, we present a combination of experiments and modeling of a two-layer anode structure designed by EnPower Inc. for high-energy and fast-charge capabilities. The anode consists of lower porosity near the current collector and higher porosity near the separator with comparable active materials in both regions. A pseudo-two-dimensional electrochemical–thermal model was designed to represent the performance of this electrode. Simulations, consistent with experiments, show superior ion transport and lithiation in the multi-layer anode (MLA) compared to a conventional single-layer anode (SLA). Surprisingly, this improved transport in MLA manifests as enhanced cathode performance during high-rate discharge and this, in turn, provides higher energy density for MLA. Similarly, during fast charge, less irreversible lithium is deposited due to this improved transport in MLA, and hence MLA exhibits less capacity fade compared to SLA. Polarization analysis demonstrates marginally lower cumulative overpotential for MLA in different case studies; however, MLA cells maintain a significantly higher capacity in the same conditions and have more than double the cycle life. Further, this means despite the apparently limited polarization benefit provided by MLA; the MLA structure can more reliably be employed in cell designs. Additional design changes are also analyzed by means of the model.

25 ENERGY STORAGE↗

Design, fabrication, and testing of a water-cooled tungsten-foam high-heat flux plasma-facing module

Here, we present a comprehensive study detailing the design, fabrication and testing a new modular “finger” component, featuring a hexagonal tungsten foam armor tile bonded to the top surface of the water-cooled finger unit. The mechanical, thermal, and particle transport properties of the tungsten foam armor were determined for a wide range of porosity and cell size, and then combined in an equivalent solid material with “effective” properties suitable for large-scale simulations. A series of 3-D multiphysics simulations for coupled thermal and mechanical behavior of the “finger” module are used to optimize the design before fabrication. The simulation results show that, for the expected experimental conditions, a safe range of heat flux and foam porosity is possible for both water-cooling and helium-cooling. Based on these multiphysics simulations, an optimum finger cooling module has been fabricated at Ultramet, Inc. A series of experiments were designed to study the thermomechanical performance of the “finger” unit under steady-state and transient thermal loading at surface heat flux up to 16 MW/m 2 in the High Energy Flux Test facility (HEFTY) at UCLA. Testing conditions included low-power, steady-state plasma exposure at 6 MW/m 2 , followed by severe high heat flux cycles at 16 MW/m 2 . Results of these tests are explained through comparisons with multiphysics simulations. To eliminate the effects of thermomechanical damage carried out on a module on its thermo-mechanical response on a subsequent test, three different yet identically designed and fabricated finger modules were tested. The results show that the current design is capable of cooling the walls of fusion devices at surface heat flux up to 6 MW/m 2 without failure, and that the failure heat flux limit is below 16 MW/m 2 .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗