Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image processing.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

PlantCV v2: Image analysis software for high-throughput plant phenotyping

Systems for collecting image data in conjunction with computer vision techniques are a powerful tool for increasing the temporal resolution at which plant phenotypes can be measured non-destructively. Computational tools that are flexible and extendable are needed to address the diversity of plant phenotyping problems. We previously described the Plant Computer Vision (PlantCV) software package, which is an image processing toolkit for plant phenotyping analysis. The goal of the PlantCV project is to develop a set of modular, reusable, and repurposable tools for plant image analysis that are open-source and community-developed. Here in this paper we present the details and rationale for major developments in the second major release of PlantCV. In addition to overall improvements in the organization of the PlantCV project, new functionality includes a set of new image processing and normalization tools, support for analyzing images that include multiple plants, leaf segmentation, landmark identification tools for morphometrics, and modules for machine learning.

59 BASIC BIOLOGICAL SCIENCES↗

Multiscale characterization and representation of variability in ceramic matrix composites

Low density, high strength, and high creep and oxidation resistance properties of ceramic matrix composites (CMCs) make them an ideal choice for use in extreme environments in space and military applications. This paper presents a detailed characterization study of structural and manufacturing flaws in Carbon fiber Silicon-Carbide-Nitride matrix (C/SiNC) CMCs at different length-scales. Energy-dispersive spectroscopy (EDS) is used for the chemical characterization of the material’s elemental constituents. High-resolution multiscale graphs obtained from scanning electron microscope (SEM) and confocal laser scanning microscope (LSM) are used to characterize the distribution and morphology of defects at different length scales. This is followed by the classification and quantification of the common manufacturing defects. An image processing algorithm based on the image segmentation process is developed to quantify the variability of various scale-dependent architectural parameters. Finally, a three-dimensional stochastic representative volume element (SRVE) generation algorithm is developed to provide precise representations of material textures at multiple length scales. The developed algorithm accurately accounts for material features and flaws based on a range of multiscale structural and defects characterization results.

36 MATERIALS SCIENCE↗

X-ray scatter correction method for dedicated breast computed tomography

Purpose: To improve image quality and accuracy in dedicated breast computed tomography (BCT) by removing the x-ray scatter signal included in the BCT projections. Methods: The previously characterized magnitude and distribution of x-ray scatter in BCT results in both cupping artifacts and reduction of contrast and accuracy in the reconstructions. In this study, an image processing method is proposed that estimates and subtracts the low-frequency x-ray scatter signal included in each BCT projection postacquisition and prereconstruction. The estimation of this signal is performed using simple additional hardware, one additional BCT projection acquisition with negligible radiation dose, and simple image processing software algorithms. The high frequency quantum noise due to the scatter signal is reduced using a noise filter postreconstruction. The dosimetric consequences and validity of the assumptions of this algorithm were determined using Monte Carlo simulations. The feasibility of this method was determined by imaging a breast phantom on a BCT clinical prototype and comparing the corrected reconstructions to the unprocessed reconstructions and to reconstructions obtained from fan-beam acquisitions as a reference standard. One-dimensional profiles of the reconstructions and objective image quality metrics were used to determine the impact of the algorithm. Results: The proposed additional acquisition results in negligible additional radiation dose to the imaged breast ({approx}0.4% of the standard BCT acquisition). The processed phantom reconstruction showed substantially reduced cupping artifacts, increased contrast between adipose and glandular tissue equivalents, higher voxel value accuracy, and no discernible blurring of high frequency features. Conclusions: The proposed scatter correction method for dedicated breast CT is feasible and can result in highly improved image quality. Further optimization and testing, especially with patient images, is necessary to characterize its impact on clinical performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A whole-system approach to x-ray spectroscopy in cargo inspection systems

The bremsstrahlung x-ray spectrum used in high-energy, high-intensity x-ray cargo inspection systems is attenuated and modified by the materials in the cargo in a Z-dependent way. Therefore, spectroscopy of the detected x rays yields information about the Z of the x-rayed cargo material. It has previously been shown that such ZSpectroscopy (Z-SPEC) is possible under certain circumstances. A statistical approach, Z-SCAN (Z-determination by Statistical Count-rate ANalysis), has also been shown to be effective, and it can be used either by itself or in conjunction with Z-SPEC when the x-ray count rate is too high for individual x-ray spectroscopy. Both techniques require fast x-ray detectors and fast digitization electronics. It is desirable (and possible) to combine all techniques, including x-ray imaging of the cargo, in a single detector array, to reduce costs, weight, and overall complexity. In this paper, we take a whole-system approach to x-ray spectroscopy in x-ray cargo inspection systems, and show how the various parts interact with one another. Faster detectors and read-out electronics are beneficial for both techniques. A higher duty-factor x-ray source allows lower instantaneous count rates at the same overall x-ray intensity, improving the range of applicability of Z-SPEC in particular. Using an intensity-modulated advanced x-ray source (IMAXS) allows reducing the x-ray count rate for cargoes with higher transmission, and a stacked-detector approach may help material discrimination for the lowest attenuations. Image processing and segmentation allow derivation of results for entire objects, and subtraction of backgrounds. We discuss R and D performed under a number of different programs, showing progress made in each of the interacting subsystems. We discuss results of studies into faster scintillation detectors, including ZnO, BaF{sub 2} and PbWO{sub 4}, as well as suitable photo-detectors, read-out and digitization electronics. We discuss high-duty-factor linear-accelerator x-ray sources and their associated requirements, and how such sources improve spectroscopic techniques. We further discuss how image processing techniques help in correcting for backgrounds and overlapping materials. In sum, we present an integrated picture of how to optimize a cargo inspection system for x-ray spectroscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A simple algorithm for beam profile diagnostics using a thermographic camera

A new algorithm for digital image processing apparatuses is developed to evaluate profiles of high-intensity DC beams from temperature images of irradiated thin foils. Numerical analyses are performed to examine the reliability of the algorithm. To simulate the temperature images acquired by a thermographic camera, temperature distributions are numerically calculated for 20 MeV proton beams with different parameters. Noise in the temperature images which is added by the camera sensor is also simulated to account for its effect. Using the algorithm, beam profiles are evaluated from the simulated temperature images and compared with exact solutions. We find that niobium is an appropriate material for the thin foil used in the diagnostic system. We also confirm that the algorithm is adaptable over a wide beam current range of 0.11–214 μA, even when employing a general-purpose thermographic camera with rather high noise (ΔT{sub NETD} ≃ 0.3 K; NETD: noise equivalent temperature difference)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Sloan Digital Sky Survey COADD: 275 deg{sup 2} of deep Sloan Digital Sky Survey imaging on stripe 82

We present details of the construction and characterization of the coaddition of the Sloan Digital Sky Survey (SDSS) Stripe 82 ugriz imaging data. This survey consists of 275 deg{sup 2} of repeated scanning by the SDSS camera over –50° ≤ α ≤ 60° and –1.°25 ≤ δ ≤ +1.°25 centered on the Celestial Equator. Each piece of sky has ∼20 runs contributing and thus reaches ∼2 mag fainter than the SDSS single pass data, i.e., to r ∼ 23.5 for galaxies. We discuss the image processing of the coaddition, the modeling of the point-spread function (PSF), the calibration, and the production of standard SDSS catalogs. The data have an r-band median seeing of 1.''1 and are calibrated to ≤1%. Star color-color, number counts, and PSF size versus modeled size plots show that the modeling of the PSF is good enough for precision five-band photometry. Structure in the PSF model versus magnitude plot indicates minor PSF modeling errors, leading to misclassification of stars as galaxies, as verified using VVDS spectroscopy. There are a variety of uses for this wide-angle deep imaging data, including galactic structure, photometric redshift computation, cluster finding and cross wavelength measurements, weak lensing cluster mass calibrations, and cosmic shear measurements.

79 ASTRONOMY AND ASTROPHYSICS↗

Capturing Maize Stand Heterogeneity Across Yield-Stability Zones Using Unmanned Aerial Vehicles (UAV)

Despite the new equipment capabilities, uneven crop stands are still common occurrences in crop fields, mainly due to spatial heterogeneity in soil conditions, seedling mortality due to herbivore predation and disease, or human error. Non-uniform plant stands may reduce grain yield in crops like maize. Thus, detecting signs of variability in crop stand density early in the season provides critical information for management decisions and crop yield forecasts. Processing techniques applied on images captured by unmanned aerial vehicles (UAVs) has been used successfully to identify crop rows and estimate stand density and, most recently, to estimate plant-to-plant interval distance. Here, we further test and apply an image processing algorithm on UAV images collected from yield-stability zones in a commercial crop field. Our objective was to implement the algorithm to compare variation of plant-spacing intervals to test whether yield differences within these zones are related to differences in crop stand characteristics. Our analysis indicates that the algorithm can be reliably used to estimate plant counts (precision >95% and recall >97%) and plant distance interval (R2 ~0.9 and relative error <10%). Analysis of the collected data indicated that plant spacing variability differences were small among plots with large yield differences, suggesting that it was not a major cause of yield variability across zones with distinct yield history. This analysis provides an example of how plant-detection algorithms can be applied to improve the understanding of patterns of spatial and temporal yield variability.

47 OTHER INSTRUMENTATION↗

Quantitative Analysis of Flow Processes in a Sand Using Synchrotron-Based X-ray Microtomography

Pore-scale multiphase flow experiments were developed to nondestructively visualize water flow in a sample of porous material using X-ray microtomography. The samples were exposed to similar boundary conditions as in a previous investigation, which examined the effect of initial flow rate on observed dynamic effects in the measured capillary pressure-saturation curves; a significantly higher residual saturation and higher capillary pressures were found when the sample was drained fast using a high air-phase pressure. Prior work applying the X-ray microtomography technique to pore-scale multiphase flow problems has been of a mostly qualitative nature and no experiments have been presented in the existing literature where a truly quantitative approach to investigating the multiphase flow process has been taken, including a thorough image-processing scheme. The tomographic images presented here show, both by qualitative comparison and quantitative analysis in the form of a nearest neighbor analysis, that the dynamic effects seen in previous experiments are likely due to the fast and preferential drainage of large pores in the sample. Once a continuous drained path has been established through the sample, further drainage of the remaining pores, which have been disconnected from the main flowing water continuum, is prevented.

42 ENGINEERING↗

Initial Assessment of X-Ray Computer Tomography image analysis for material defect microstructure

The original development work leading to this report was focused on the non destructive three-dimensional (3-D) characterization of nuclear graphite as a means to better understand the nature of the inherent pore structure. The pore structure of graphite and its evolution under various environmental factors such as irradiation, mechanical stress, and oxidation plays an important role in their observed properties and characteristics. If we are to transition from an empirical understanding of graphite behavior to a truly predictive mechanistic understanding the pore structure must be well characterized and understood. As the pore structure within nuclear graphite is highly interconnected and truly 3-D in nature, 3-D characterization techniques are critical. While 3-D characterization has been an excellent tool for graphite pore characterization, it is applicable to a broad number of materials systems over many length scales. Given the wide range of applications and the highly quantitative nature of the tool, it is quite surprising to discover how few materials researchers understand and how valuable of a tool 3-D image processing and analysis can be. Ultimately, this report is intended to encourage broader use of 3 D image processing and analysis in materials science and engineering applications, more specifically nuclear-related materials applications, by providing interested readers with enough familiarity to explore its vast potential in identifying microstructure changes. To encourage this broader use, the report is divided into two main sections. Section 2 provides an overview of some of the key principals and concepts needed to extract a wide variety of quantitative metrics from a 3-D representation of a material microstructure. The discussion includes a brief overview of segmentation methods, connective components, morphological operations, distance transforms, and skeletonization. Section 3 focuses on the application of concepts from Section 2 to relevant materials at Idaho National Laboratory. In this section, image analysis examples featuring nuclear graphite will be discussed in detail. Additionally, example analyses from Transient Reactor Test Facility low-enriched uranium conversion, Advanced Gas Reactor like compacts, and tristructural isotopic particles are shown to give a broader perspective of the applicability to relevant materials of interest.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

On the possibility of a significant improvement in the quality of a quantum ghost image by registering an additional image in the object channel

A modification of the classical scheme of the quantum ghost image formation is considered, in which an image of the object under study is formed and recorded in the object channel. This image is used together with the ghost image to construct an estimate of the transparency distribution of the object. It is shown that this technique reduces the image quality worsening associated with the non-unit quantum efficiency of the sensors, even when the quantum image obtained in the object channel is additionally distorted by noise due to photons that did not interact with the object. (image processing)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

DARHT Radiographic Grid Scale Correction

Recently it became apparent that the radiographic grid which has been used to calibrate the dimensional scale of DARHT radiographs was not centered at the location where the objects have been centered. This offset produced an error of 0.188% in the dimensional scaling of the radiographic images processed using the assumption that the grid and objects had the same center. This paper will show the derivation of the scaling correction, explain how new radiographs are being processed to account for the difference in location, and provide the details of how to correct radiographic image processed with the erroneous scale factor.

47 OTHER INSTRUMENTATION↗

Radiographic Magnification Differences Due To Grid Placement at DARHT

In 2015, it became apparent that the radiographic grid, which has been used to calibrate the dimensional scale of DARHT radiographs, was not centered at the location where the objects have been centered along the beamline. Instead of the grid center being placed at 133.0 cm, the grid downstream face was placed at this location, putting the grid center at 132.75 cm. This o set produced an error of 0.188% in the dimensional scaling of the radiographic images processed, using the assumption that the grid and objects had the same center. The Air Force Target (AFT) had the same holder as the grid, while the Circular Resolution Target (CRT) used a holder that correctly placed the object center at 133.0 cm. These erroneous holders were used until October 2015. Starting in November 2015, new holders were used that placed all static target objects in the correct location, with their center at 133.0 cm. This paper will show the derivation of the scaling correction, explain how old radiographs are being processed to account for the difference in location, and provide the details of how to correct radiographic images processed with the erroneous scale factor.

47 OTHER INSTRUMENTATION↗

Three-dimensional visualization and characterization of bone structure using reconstructed in-vitro μCT images: A pilot study for bone microarchitecture analysis

Micro Computed Tomography (μCT) has been largely used to perform micrometer scale imaging of specimens, bone biopsies and small animals for the study of porous or cavity-containing objects. One of its favored applications is for assessing structural properties of bone. In this research, we perform a pilot study to visualize and characterize bone structure of a chicken bone thigh, as well as to delineate its cortical and trabecular bone regions. We utilize an In-Vitro μCT scanner Skyscan 1173 to acquire a three dimensional image data of a chicken bone thigh. The thigh was scanned using X-ray voltage of 45 kV and current of 150 μA. The reconstructed images have spatial resolution of 142.50 μm/pixel. Using image processing and analysis e.i segmentation by thresholding the gray values (which represent the pseudo density) and binarizing the images, we were able to visualize each part of the bone, i.e., the cortical and trabecular regions. Total volume of the bone is 4663.63 mm{sup 3}, and the surface area of the bone is 7913.42 mm{sup 2}. The volume of the cortical is approximately 1988.62 mm{sup 3} which is nearly 42.64% of the total bone volume. This pilot study has confirmed that the μCT is capable of quantifying 3D bone structural properties and defining its regions separately. For further development, these results can be improved for understanding the pathophysiology of bone abnormality, testing the efficacy of pharmaceutical intervention, or estimating bone biomechanical properties.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of nonlinear three-dimensional optimized reconstruction algorithm filter on image quality and radiation dose: Validation on phantoms

A new technique called the nonlinear three-dimensional optimized reconstruction algorithm filter (3D ORA filter) is currently used to improve CT image quality and reduce radiation dose. This technical note describes the comparison of image noise, slice sensitivity profile (SSP), contrast-to-noise ratio, and modulation transfer function (MTF) on phantom images processed with and without the 3D ORA filter, and the effect of the 3D ORA filter on CT images at a reduced dose. For CT head scans the noise reduction was up to 54% with typical bone reconstruction algorithms (H70) and a 0.6 mm slice thickness; for liver CT scans the noise reduction was up to 30% with typical high-resolution reconstruction algorithms (B70) and a 0.6 mm slice thickness. MTF and SSP did not change significantly with the application of 3D ORA filtering (P>0.05), whereas noise was reduced (P<0.05). The low contrast detectability and MTF of images obtained at a reduced dose and filtered by the 3D ORA were equivalent to those of standard dose CT images; there was no significant difference in image noise of scans taken at a reduced dose, filtered using 3D ORA and standard dose CT (P>0.05). The 3D ORA filter shows good potential for reducing image noise without affecting image quality attributes such as sharpness. By applying this approach, the same image quality can be achieved whilst gaining a marked dose reduction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

AGR-2 TRISO Shadow Imaging Archive

As a part of fuel quality control characterization, backlit shadow images of particles produced by the Advanced Gas Reactor Fuel Development and Qualification (AGR) Program’s AGR-2 irradiation campaign were acquired at Oak Ridge National Laboratory (ORNL). These images may be of use for the development of image processing algorithms with the benchmark values measured at ORNL. This report provides those benchmark values, along with the raw images and data generated by the ORNL shadow imaging process.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Aerial 3D Building Reconstruction from Drone Imagery (A3DBR) v1

This toolkit is composed of several modules for extracting buildings geometrical and thermal characteristics from RGB and thermal imagery captured using a drone. - Building 3D reconstruction module: leverage a photogrammetry software to construct a 3D point cloud from RGB drone imagery, which is then used in conjunction with image processing and geometric methods to extract building footprint and building height (i.e., 3D model of the building). - Windows to wall ratio estimation module: leverage deep learning semantic segmentation modeling to detect windows on 2D drone RGB images. The detected windows are then projected onto the extracted building 3D model (using building 3D reconstruction module) and their area is computed to obtain window to wall ratio estimation. - Thermal anomalies detection module: leverage image processing and machine learning algorithm to detect on 2D drone thermal images potential thermal anomalies within building's facades and roofs.

Granderson, Jessica↗

THE UNAM-KIAS CATALOG OF ISOLATED GALAXIES

A new catalog of isolated galaxies from the Sloan Digital Sky Survey Data Release 5 (SDSS DR5) is presented. A total of 1520 isolated galaxies were found in 1.4 sr of sky. The selection criteria in this UNAM-KIAS catalog are a variation on the criteria developed by Karachentseva, including full redshift information. Through an image processing pipeline that takes advantage of the high-resolution ({approx}0.''4 pixel{sup -1}) and high dynamic range of the SDSS images, a uniform g-band morphological classification for all these galaxies is presented. We identify 80% (Sa-Sm) spirals (50% later than Sbc types) on one hand, and a scarce population of early-type E (6.5%) and S0 (8%) galaxies amounting to 14.5% on the other hand. This magnitude-limited catalog is {approx}80% complete at 16.5, 15.6, 15.2, 14.6, and 14.4 mag in the ugriz bands, respectively. Some representative physical properties including SDSS magnitudes and color distributions, color-color diagrams, absolute magnitude-color, and concentration-color diagrams as a function of morphological type are presented. The UNAM-KIAS Morphological Atlas is also released along with this paper. For each galaxy of a type later than Sa, a mosaic is presented that includes (1) a g-band logarithmic image, (2) a g-band filtered-enhanced image where a Gaussian kernel of various sizes was applied, and (3) a red giant branch color image from the SDSS database. For E/S0/Sa galaxies, in addition to the images in (1), (2), and (3), plots of r-band surface brightness and geometric profiles (ellipticity {epsilon}, position angle PA, and A{sub 4}/B{sub 4} coefficients of the Fourier series expansions of deviations of a pure ellipse) are provided. The size of the sample, the redshift completeness, the availability of high-quality multicolor photometric data and detailed morphological and spectroscopic information make the UNAM-KIAS catalog of isolated galaxies a suitable sample to address important issues such as (1) comparative studies of environmental effects, (2) constraining the currently competing scenarios of galaxy formation and evolution, (3) the nature and evolution of elliptical and spiral galaxies in the field, (4) the spectral properties of a statistically significant number of isolated galaxies and their evolution as a function of redshift, and (5) the fraction of active galactic nuclei in isolated environments, among other important topics. The optimization and estimation of new structural parameters as well as important information to complement existing ones in other wavelengths is being carried out.

79 ASTRONOMY AND ASTROPHYSICS↗

Some features of photolithography image formation in partially coherent light

The coherent-noise level in projection images of an opaque-screen sharp edge, formed in the model scheme of photolithography system at different degrees of spatial coherence of screen-illuminating light is studied experimentally. The spatial coherence of laser radiation was reduced by applying a specially developed device, used as a separate functional unit in the system model. The smoothing of the spatial fluctuations of radiation intensity caused by the random spatial inhomogeneity of the initial beam intensity in the obtained images is shown to be highly efficient. (imaging and image processing. holography)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗