Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “High Temperature Plasma”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Comments regarding energy release and transfer in solar flares

Skylab observations of the high-temperature coronal plasma are used in characterizing energy released in the corona during flare-like events. The loop structure of the soft X-ray flare features is reviewed; short-term exposures of several soft X-ray images are employed in suggesting that energy, and possibly material as well, is added to the apex of loop systems during flare events. An accompanying restriction in the flow of mass and energy from the loop apex is also hypothesized to account for the recorded observations. Further investigations of the confining ability of the magnetic fields that contain the X-ray emitting plasma are proposed.

Vorpahl, J. A.↗

Rugged Preheaters For Vacuum Plasma Spraying

Electric preheater units built to ensure large workpieces to be coated with metals by vacuum plasma spraying heated uniformly to requisite high temperatures by time plasma torch arrives. Units similar to electrical-resistance ribbon heaters in toasters and in some small portable electric "space" heaters. Nichrome resistance-heating ribbons wrapped around ceramic insulating spools on rings and on plates. Round workpiece placed in middle of ring preheater. Plate preheaters stacked as needed near workpiece.

Woodford, William H.↗

Adaptable Holders for Arc-Jet Screening Candidate Thermal Protection System Repair Materials

Reusable holders have been devised for evaluating high-temperature, plasma-resistant re-entry materials, especially fabrics. Typical material samples tested support thermal-protection-system damage repair requiring evaluation prior to re-entry into terrestrial atmosphere. These tests allow evaluation of each material to withstand the most severe predicted re-entry conditions.

Riccio, Joe↗

Locking Nut with Stress-Distributing Insert

Reusable holders have been devised for evaluating high-temperature, plasma-resistant re-entry materials, especially fabrics. Typical material samples tested support thermal-protection-system damage repair requiring evaluation prior to re-entry into terrestrial atmosphere. These tests allow evaluation of each material to withstand the most severe predicted re-entry conditions.

Daniels, Christopher C.↗

The Effects of Substrate Material and Thermal Processing Atmosphere on the Strength of PS304: A High Temperature Solid Lubricant Coating

PS304, a plasma spray deposited solid lubricant coating developed for high temperature sliding contacts was deposited on nine different substrate metals, heat treated at 650C in either air or argon and subsequently tested for strength using a commercially available pull-off adhesion test. Some samples were examined metallographically to help elucidate and explain the results. As deposited coatings exhibit pull-off strengths typically between 16 and 20 MPa with failure occuring (cohesively) within the coating. Heat treatment in argon at 650 C results in a slight increase in coating (cohesive) strength of about 30 percent to 21 to 27 MPa. Heat treatment in air at 650 C results in a dramatic increase in strength to over 30 MPa, exceeding the strength of the epoxy used in the pull test. Cross section metallographic analyses show that no microstructural coating changes occur following the argon heat treatments, however, exposure to air at 650C gives rise to the formation of a second chromium-rich phase precipitate within the PS304 NiCr constituent which provides a strengthening effect and a slight (approximately 5 percent) coating thickness increase. Subsequent heat treatments do not result in any further coating changes. Based upon these studies, PS304 is a suitable coating for use on a wide variety of high temperature substrates and must be heat treated following deposition to enhance strength and ensure dimensional stability.

DellaCorte, Christopher↗

Monitoring Temperature in High Enthalpy Arc-heated Plasma Flows using Tunable Diode Laser Absorption Spectroscopy

A tunable diode laser sensor was designed for in situ monitoring of temperature in the arc heater of the NASA Ames IHF arcjet facility (60 MW). An external cavity diode laser was used to generate light at 777.2 nm and laser absorption used to monitor the population of electronically excited oxygen atoms in an air plasma flow. Under the assumption of thermochemical equilibrium, time-resolved temperature measurements were obtained on four lines-of-sight, which enabled evaluation of the temperature uniformity in the plasma column for different arcjet operating conditions.

Martin, Marcel Nations↗

Dielectric Resonator Design for Low Power and Low Temperature Microwave Plasma

Waveguide-based microwave plasmas generally operate at high temperatures (2000 - 6000K)[1], making it difficult to directly interface solid materials with the plasma without significant thermal damage. Dielectric microwave resonators (DMRs), long studied for wave-based manipulation of electromagnetic radiation for telecom and optics, can focus radiation to extremely small mode volumes, creating intense localized fields with low-power input.[2] This phenomenon can be used for applications ranging from efficient plasma electronics to near-ambient plasma-materials interactions. Such DMR-based plasmas have been demonstrated a handful of times in the literature, but the majority of research towards this utilize the lowest frequency resonance mode.[3], [4], [5] By carefully controlling the geometry of cylindrical resonators, a variety of electromagnetic modes can be excited. In this work, COMSOL Multiphysics simulations are used to study the electric field enhancement and absorption properties of CaTiO3 DMRs as a function of geometry and excitation frequency. Whereas previous studies have utilized the HEM111 resonance frequency to drive low power plasma excitation, we find that higher order resonance frequencies are more effective at field enhancement and result in less power loss within the dielectric material, hence less wasted heating. The effectiveness of these modes is also geometry dependent and can be computationally optimized for plasma generation. Complementing these computational efforts, we demonstrate a new closed-system reactor design built in a WR-650 waveguide and experimentally demonstrate the formation of atmospheric argon microwave plasma using < 30 W input power on DMR dimers. We observe a shifting resonance frequency as the DMRs heat in response to microwave excitation and develop a Python-based lock-in mechanism to effectively track the DMR resonance over time, leading to stable plasma operation. We use infrared thermal imaging to monitor the temperature of the DMR dimers and surrounding quartz chamber, demonstrating thermal temperatures < 60 degreesC. Finally, we utilize optical emission spectroscopy (OES) to probe the plasma properties as a function of the resonance mode.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

How fast ions mitigate turbulence and enhance confinement in tokamak fusion plasmas

Along with high temperature and density, magnetic fusion requires good confinement and a degree of transport control for thermal plasmas. Meanwhile, fast ions are generated by the external heating used to raise plasma temperature and by the fusion reactions. As a result, the fusion plasmas are effectively rendered into systems with two coexisting populations of main interest — namely, the fast ions and the thermal plasma. Interestingly, several recent experiments indicate that the fast-ion population can improve the confinement of the thermal plasmas by mitigating turbulence. Here, in this Review, we describe the physical mechanisms that underpin the improved confinement and discuss recent experimental results in terms of these mechanisms.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Apparatus for production, measurement and reaction studies of dissociated gases at elevated temperatures

An apparatus is described which is used for the controlled production, characterization, and study of dissociated gases in a microwave discharge at elevated temperatures. A unique feature is the ability to produce and study a microwave discharge plasma in the heated zone. This allows elevated temperature reactions to be studied in high concentrations of dissociated gases. Further, the system permits weight change measurements of specimens in the plasma, thus facilitating reaction rate determinations. Included is a description of a cavity for use on a 50-mm diameter cylindrical reactor. The effects of flow rate, pressure, temperature, power, metal sample, and sampling position on dissociation percentage of oxygen in the apparatus are described as well as a technique for sample temperature measurements in the plasma which permits determination of high temperature recombination coefficients and reaction rates.

Christian, J. D.↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

High hydrogen coverage on graphene via low temperature plasma with applied magnetic field

The chemical functionalization of two-dimensional materials is an effective method for tailoring their chemical and electronic properties with encouraging applications in energy, catalysis, and electronics. One exemplary 2D material with remarkable properties, graphene, can be exploited for hydrogen storage and large on/off ratio devices by hydrogen termination. In this work, we describe a promising plasma-based method to provide high hydrogen coverage on graphene. A low pressure (~10 mtorr) discharge generates a fine-tunable low-temperature hydrogen-rich plasma in the applied radial electric and axial magnetic fields. Post-run characterization of these samples using Raman spectroscopy and X-ray photoelectron spectroscopy demonstrates a higher hydrogen coverage, 35.8%, than the previously reported results using plasmas. Plasma measurements indicate that with the applied magnetic field, the density of hydrogen atoms can be more than 10 times larger than the density without the magnetic field. With the applied electric field directed away from the graphene substrate, the flux of plasma ions towards this substrate and the ion energy are insufficient to cause measurable damage to the treated 2D material. As a result, the low damage allows a relatively long treatment time of the graphene samples that contributes to the high coverage obtained in these experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nuclear pumping of lasers.

Summary of the theoretical and experimental work dealing with nuclear lasers that has been completed during the last year (1971), and review of some new work which may help to establish the direction research in this field may take in the future. So far, the most successful experiments have been carried out utilizing nuclear enhancement of electrically excited CO2 lasers. The goal of attaining lasing in gases utilizing nuclear pumping without an applied electric field is much more difficult to achieve but is being pursued. No experimental or theoretical work has been undertaken thus far in the study of the class of lasers where high-energy particles are produced internally in high-temperature multiple ionized plasmas. Some new approaches to high-power nuclear lasers are suggested.

Russell, G. R.↗

Steady-state hot-ion plasma produced by crossed electric and magnetic fields

Results of initial diagnostics on the Lewis Research Center hot-ion-plasma source (HIP-1) are reported. The mirror-contained plasma was heated by applying a radial electric field similar to that used in the ORNL burnout experiments. An electrostatic neutral particle analyzer was used to make a parametric study of ion energy distributions in both hydrogen and euterium plasmas. Ion temperatures as high as 2 keV were measured in plasmas with electron densities greater than 10 to 12th power/cu cm. The performance of the device was found to be extremely sensitive to a magnetic field. There are indications that ion heating was reduced when the size of the Larmor orbit was larger than the region of a strong radial electric field.

Sigman, D. R.↗

Free Fall Plasma-Arc Reactor for Synthesis of Carbon Nanotubes in Microgravity

High temperatures inside the plasma of a carbon arc generate strong buoyancy driven convection which has an effect on the growth and morphology of the single-walled carbon nanotubes (SWNTs). To study the effect of buoyancy on the arc process, a miniature carbon arc apparatus was designed and developed to synthesize SWNTs in a microgravity environment substantially free from buoyant convective flows. An arc reactor was operated in the 2.2- and 5.18-second drop towers at the NASA Glenn Research Center. The apparatus employed a 4 mm diameter anode and was powered by a portable battery pack capable of providing in excess of 300 amps at 30 volts to the arc for the duration of a 5-second drop. However, the principal result is that no dramatic difference in sample yield or composition was noted between normal gravity, 2.2-and 5-second long microgravity runs.

Alford, J. M.↗

Development of Lunar Highland REgolith Simulants, NU-LHT-1M,-2M

As part of a collaborative agreement between the U.S, Geological Survey (USGS) and NASA's Marshall Space Flight Center (MSFC) lunar highland simulants are being produced to support engineers and scientists in developing the technologies required to put a base on the moon by 2024. Two simulants have been produced to date: NU-LHT-1M and -2M (NASA/USGS-Lunar Highlands Type-l & 2 Medium-grained). Using starting material chiefly collected from the Stillwater Mine, Nye, MT, blending protocols were developed based on normative mineralogy calculated from average chemistry, for the Apollo 16 regolith. New technologies using a high temperature remotely coupled plasma melter were developed to generate both high quality and agglutinitic glasses that simulate the glassy components of the regolith. Detailed chemical, mineralogical and physical properties analysis of NU-LHT-1M indicate that it is overall a good surrogate for highlands lunar regolith (our new simulant LHT-2M has not be analyzed yet). The primary difference between 1M and 2M was the inclusion of trace mineralogy (phosphates and sulfide). Plans will also be presented on the future direction of the simulant project.

Stoeser, D. B.↗

High-temperature compressive creep tests of U 3 Si 2 with spark plasma sintering: Experiments and finite element modeling

This paper reports a systematic high-temperature creep behavior of dense U 3 Si 2 pellets using a spark plasma sintering (SPS) apparatus at elevated temperatures and pressures under vacuum conditions. The stress exponent was subsequently derived to be 3.21 at 1173 K and 2.17 at 1223 K, respectively, indicating a grain boundary sliding creep mechanism. The creep activation energy was determined to be 203.6 ± 19.0 kJ/mol, which agrees well with the literature. Finite element modeling was performed using the creep parameters fitted from the strain-time plot. Additionally, the results suggest an excellent match with the experimental data, confirming the validity of the experiments. Microstructure characterizations indicate that the main phase of the specimens after creep tests remains to be U 3 Si 2 , with a 4 μm thick layer of nano-sized particles induced from the diffusion between U 3 Si 2 and alumina disc used to avoid electric current passing through the sample. The successful conduct of creep experiments demonstrates the great potential of SPS to perform high-temperature mechanical testing of nuclear fuels under vacuum conditions. The subsequent finite element modeling exhibits excellent capabilities for accurately predicting material performance in the creep tests and provides a practical tool in evaluating nuclear fuels’ performance for a much-extended time scale.

36 MATERIALS SCIENCE↗

The Impact of Anomalous Resistivity in Vacuum Contaminant Plasmas on the Electrothermal Instability

This manuscript presents an assessment of the electrothermal instability (ETI) in the presence of anomalous resistivity (AR) in vacuum contaminant plasmas (VCP) when applied to a magnetized liner inertial fusion (MagLIF)-like load.Pulsed-power driven dielectrically coated metallic liners, like in MagLIF, experience the current-driven electrothermal instability which occurs when a material’s resistivity changes with temperature and is subject to ohmic heating. Large scale pulsed-power facilities that use magnetically insulated transmission lines (MITL) have been shown to generate low-density plasma which enters the target chamber and coalesces around the load. The low-density high-temperature vacuum contaminant plasmas (VCP) can parasitically divert current from the load through causing a short in the anode-cathode gap inside the target chamber. Resistive magnetohydrodynamic (MHD) simulations of these VCP experience unphysical runaway ohmic heating due to under predicting the resistivity by using a purely collisional resistivity model.AR provides a physics-based way to address this runaway heating through increasing the resistivity in a proportional way with the drift speed. In this work, 1D simulations probe the effect that AR in VCP has on the magnetic diffusion rate, and 2D simulations show how this effect manifests in the nonlinear striation form of the ETI for a MagLIF-like load. Beryllium and aluminum dielectrically coated liners are used for the 1D and 2D simulations in this work. The1D simulations show that a VCP causes a delay in the current delivery to the load by upwards of 8 ns at 60 ns into atypical current pulse for an 1 × 10 7 A scale pulsed-power accelerator. The 2D simulations show the delay observed in the 1D simulations is reduced substantially (4 ns) by 2D turbulence that disrupts the VCP layer early in time. Here, the 2Dsimulated ETI growth varies across AR models, more so for the beryllium liner than the aluminum liner because the beryllium liner shows an enhanced rate of penetration for the magnetic diffusion wave in comparison to the aluminum liner. The 2D simulations show the bulk dielectric thickness varies across AR models with the Davidson AR model beingthe largest and the Buneman AR model being the smallest, and in connection with the thickness the Rayleigh-Taylor bubble-spike distances varies correspondingly.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗