Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heat integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Pilot scale testing of an advanced solvent in a 0.7 MWe post-combustion CO 2 capture unit

An advanced Amine Promoted Buffer Solution (APBS), APBS-CDRMax® (CDRMax), developed by Carbon Clean Solutions Limited (CCSL), was tested at the 0.7 MWe CO 2 capture facility at Kentucky Utilities E.W. Brown Generation Station using a heat-integrated two-staged stripping CO 2 capture process. The performance of the solvent was evaluated to determine operating conditions that maximized the cyclic capacity of the solvent and results in energy savings. The regeneration energy ranged from 2.9 to 3.3 GJ/ton CO 2 with 14 vol % (dry) CO 2 inlet and approximately 90 % capture. The difference in the reboiler specific heat duty at stripper pressures of 1.7 and 2.1 bar was minimal as similar amounts of water vapor were observed in the CO 2 product stream at stripper outlet. Recycling of product CO 2 increased the inlet CO 2 concentration to the absorber from 14 to 16 vol% which enhanced mass transfer from the gas to the solvent resulting in about 5 % reduction in the energy of regeneration at the lower stripper pressure. The solvent circulation rate was reduced by about 30 % relative to previous 30 wt% MEA campaign for the CO 2 target capture of 90 %. Finally, the reduced solvent make-up rate of CDRMax shows promise for capital and operating cost savings for post-combustion CO 2 capture.

42 ENGINEERING↗

A novel means to flexibly operate a hybrid concentrated solar power plant and improve operation during non-ideal direct normal irradiation conditions

Hybridization of concentrated solar power (CSP) with other energy sources can drastically increase how much solar energy is harnessed and potentially expand the current geographical deployment of CSP installlations. In this study, a novel operation strategy referred to as flexible heat integration (FHI), is proposed and applied to a hybrid CSP-natural gas power plant. The proposed plant, modeled in Simulink, employs a solar central receiver (SCR) and dual-source gas boiler to drive a steam Rankine power cycle. FHI involves collecting and dispatching solar energy at modified temperatures during off-design direct normal irradiance (DNI). During low-grade (<100 W/m 2 ) and medium-grade (100–500 W/m 2 ) levels of DNI, molten salt is used for steam boiling and feedwater preheating, respectively, rather than superheating usually seen in SCR steam plants. Hybrid gas-firing supplies energy to bypassed systems. FHI is applied to a hybrid plant over the course of a day from each season for a plant located in Salt Lake City, Utah, an unconventional location due to off-design DNI variability. A spring day exhibiting variable DNI is used as the main case study to demonstrate the dynamics and robust operation under the FHI framework. The operation of the plant over the winter day shows the largest improvement in solar-to-electric (STE) efficiency whereas the summer day exhibits the smallest improvement. Monthly results follow a similar trend with FHI improving STE from 15.3% and 16.3% to 17.0% and 16.7% in January and July, respectively. Yearly results show FHI improving STE efficiency from 16.1% to 17.1% relative to standard hybrid operation. Altogether, the proposed concept expands the current understanding of energy management in hybrid SCR-natural power plants under non-ideal DNI conditions and locations that have lower DNI by applying FHI.

14 SOLAR ENERGY↗

Studies of shock/shock interaction on smooth and transpiration-cooled hemispherical nosetips in hypersonic flow

Experimental studies are conducted to examine the utilization of transpiration cooling to reduce the peak-heating loads in areas of shock/shock interaction. Smooth and transpiration-cooled nosetip models, 12 inches in diameter, were employed in these studies, which focused on defining the pressure distributions and heat transfer in type III and IV interaction areas. Transpiration cooling was determined to significantly increase the size of the shock layer and to move the peak-heating point around the body. A transpiration-cooling rate of more than 30 percent of the freestream maximum flux did not lower the peak-heating level more than 10 percent, but the integrated heating loads were reduced.

Holden, M. S.↗

Optimal Ground Source Heat Pump System Design

Despite the facts that GSHPs first gained popularity as early as the 1940’s and they can achieve 30 to 60 percent in energy savings and carbon emission reductions relative to conventional HVAC systems, the use of geothermal energy in the U.S. has been less than 1 percent of the total energy consumption. The key barriers preventing this technically-mature technology from reaching its full commercial potential have been its high installation cost and limited consumer knowledge and trust in GSHP systems to deliver the technology in a cost-effective manner in the market place. Led by ENVIRON, with support from University Hartford and University of Vermont, the team developed and tested a software-based a decision making tool (‘OptGSHP’) for the least-cost design of ground-source heat pump (‘GSHP’) systems. OptGSHP combines state of the art optimization algorithms with GSHP-specific HVAC and groundwater flow and heat transport simulation. The particular strength of OptGSHP is in integrating heat transport due to groundwater flow into the design, which most of the GSHP designs do not get credit for and therefore are overdesigned.

42 ENGINEERING↗

Efficient Parametric Uncertainty Analysis of an Earth Entry Vehicle Concept Using Least Angle Regression

The objective of this work was to outline and apply an efficient and accurate parametric un-certainty propagation approach to the analysis of convective heating on an Earth entry vehicle concept. The described approach was based on Least Angle Regression used to solve a sparse and underdetermined linear system in the point-collocation non-intrusive polynomial chaos surrogate method. This approach involved an iterative process to computing the non-zero terms of the underlying polynomial chaos model using only enough samples to converge uncertainty interval predictions and Sobol index values based global nonlinear sensitivity estimates. The Earth entry vehicle was analyzed at three points along a representative trajectory for a Mars return mission. 329 sources of uncertainty were identified in the computational fluid dynamics model used to predict the forebody convective heating. These included uncertainty in flow field chemical rates, collision integrals, heats of formation, surface finite rate char model reaction rates, wall roughness height, and the turbulent Schmidt number. Results from this study showed that convective heating uncertainty as high as 50% of the nominal was predicted with only about 50 evaluations of the computational model. This was far fewer than would be required for a sampling-based approach or a full basis polynomial chaos model, which would have required over 50,000 samples. Additionally, results showed that over 90% of the total convective heating uncertainty was due to uncertainty in the N2catalytic rate on the surface, while the remainder of the uncertainty was attributed to the turbulent Schmidt number and the wall roughness uncertainties.

Thomas K West IV↗

Chapter 5: Residential Furnaces and Boilers Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

The high-efficiency boiler and furnace measure produces gas heating savings resulting from installation of more energy-efficient heating equipment in a residence. Such equipment, which ranges in size from 60 kBtu/hr to 300 kBtu/hr, is installed primarily in single-family homes and multifamily buildings with individual heating systems for each dwelling unit. This protocol does not cover integrated heating and water heating units which can be used in lieu of space heating only equipment.

09 BIOMASS FUELS↗

Shock/shock interference on a transpiration cooled hemispherical model

Experimental results are presented which show the effectiveness of transpiration cooling in reducing the peak heat flux caused by an impinging shock on a bow shock of a hemispherical model. The 12-inch diameter hemispherical transpiration model with helium coolant was tested in the Calspan 48-inch Hypersonic Shock Tunnel at nominal Mach 12.1 and freestream unit Reynolds number of 0.33 x 10 to the 6th/ft. An incident shock wave, generated by a blunt flat-plate shock generator inclined at 10 deg to the freestream, intersected the bow shock of the model to produce shock/shock interference. The stagnation heat flux without coolant or shock/shock interference was about 1.6 times a smooth surface laminar prediction due to effective roughness of the coolant ejection slots. A coolant mass flux 31 percent of the freestream mass flux reduced the stagnation heat flux to zero without shock/shock interference. However, for the same coolant mass flux and with shock/shock interference the peak heat flux was only reduced 8.3 percent, even though the total integrated heat load was reduced.

Nowak, Robert J.↗

Simulation of the AFE mission heating in an arc-jet wind tunnel

A technique is presented for simulating a time-varying heating profile in an arc-jet wind tunnel and its application to the testing of a sapphire radiometer window assembly for the Aeroassist Flight Experiment (AFE). The AFE is an experimental mission designed to obtain as much data as possible relative to the aerodynamic and aerothermodynamic phenomena associated with aeroassisted maneuvering. The developed test procedure ensures satisfactory simulation by avoiding the thermal gradients of a step-function heat exposure by matching the heating/time values and by matching the integrated heat load. Furthermore, this is accomplished in a plasma stream in which enthalpy and pressure ensure a close approximation to the real flight environment.

Terrazas-Salinas, Imelda↗

Experimental validation of an organic rankine-vapor compression cooling cycle using low GWP refrigerant R1234ze(E)

There is a significant global opportunity to capture and utilize low grade waste heat to reduce fossil fuel consumption, greenhouse gas emissions, and improve energy efficiency across a wide range of industries. In this work, an advanced type of thermally activated cooling system, an organic Rankine-vapor compression cycle (ORVC) with novel heat integration strategies, was designed and tested at a relevant scale for industrial waste heat recovery (300 kW th cooling capacity). The ORVC linked an organic Rankine power cycle and a vapor compression cooling cycle using a turbine and compressor that shared a single shaft. The ORVC test facility absorbed waste heat from a liquid stream at 91 °C to simulate engine coolant in diesel generator sets, rejected heat to a glycol stream at 30 °C, and generated chilled water at 7 °C. A cooling capacity of 264 kW ± 3.5 kW was experimentally validated with a COP of 0.56 ± 0.01 during steady-state operation at the design temperatures. The thermal efficiency, accounting for pump work, of the Rankine cycle was 7.7% ± 0.22% and the COP of the vapor compression cycle was 5.25 ± 0.09. The centrifugal turbo-compressor operated at 31.5 kRPM ± 0.3 kRPM, with a turbine and compressor isentropic efficiencies of 76.7% ± 0.90% and 84.8% ± 0.54%, respectively, with near-perfect power transmission between these components. The pressure drop in the piping and heat exchangers were significantly larger than expected which had a detrimental impact on the performance of the ORVC. In addition, the condenser on the cooling cycle could not deliver the subcooling as specified from the design point modeling. Furthermore, the results from the sensitivity analysis showed that the higher condenser glycol outlet temperature had the largest impact on performance, which is consistent with other analytical models in the literature. When the ORVC simulations were updated with experimental values for isentropic efficiencies of the turbomachinery, the thermal COP was 0.66 which represents an estimate of the predicted performance if test facility limitations are overcome.

30 DIRECT ENERGY CONVERSION↗

Food Service System

The 3M Food Service System 2 employs a "cook/chill" concept for serving food in hospitals. The system allows staff to prepare food well in advance, maintain heat, visual appeal and nutritional value as well as reducing operating costs. The integral heating method, which keeps hot foods hot and cold foods cold, was developed by 3M for the Apollo Program. In the 1970s, the company commercialized the original system and in 1991, introduced Food Service System 2. Dishes are designed to resemble those used at home, and patient satisfaction has been high.

Source record↗

Simplified High-Temperature Molten Salt CSP Plant Preconceptual Design

State of the art concentrating solar power plants generally rely on a two-tank system with a large central tower. These plants employ nitrate salts that are limited to approximately 565°C in practice. A novel system arrangement is proposed using molten salt as the heat transfer and energy storage media in a single thermocline storage tank with an integral heat exchanger to the power cycle. The system has unique features that enable temperatures higher than 565°C while reducing costs. This study explores the considerations for the concept and presents a preconceptual point design for a 5 MWt system capable of generating 100 MWt per day with 12 hours of thermal energy storage. This study also examines the potential operation of the system with nitrate and higher temperature chloride salts. Both salt systems appear promising and future concept maturation is recommended.

14 SOLAR ENERGY↗

Potential of Utilizing Thermal Energy Storage Integrated Ground Source Heat Pump System to Reshape Electricity Demand in the United States

Each year, more than 20% of electricity generated in the United States is consumed for meeting the thermal demands (e.g., space cooling, space heating, and water heating) in residential and commercial buildings. Integrating thermal energy storage (TES) with building’s HVAC systems has the potential to reshape the electric load profile of the building and mitigate the mismatch between the renewable generation and the demand of buildings. A novel ground source heat pump (GSHP) system integrated with underground thermal energy storage (UTES) has been proposed to level the electric demand of buildings while still satisfying their thermal demands. This study assessed the potential impacts of the proposed system with a bottom-up approach. The impacts on the electricity demand in various electricity markets were quantified. The results show that, within the capacity of the existing electric grids, the maximum penetration rate of the proposed system in different wholesale markets could range from 51% to 100%. Altogether, about 46 million single-family detached houses can be retrofitted into the proposed system without increasing the annual peak demand of the corresponding markets. By implementing the proposed system at its maximum penetration rate, the grid-level summer peak demand can be reduced by 9.1% to 18.2%. Meanwhile, at the grid level, the annual electricity consumption would change by –12% to 2%. The nationwide total electricity consumption would be reduced by 9%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Carbon phenolic heat shields for Jupiter/Saturn/Uranus entry probes

Carbon phenolic heat shield technology is reviewed. Heat shield results from the outer planetary probe mission studies are summarized along with results of plasma jet testing of carbon phenolic conducted in a ten megawatt facility. Missile flight data is applied to planetary entry conditions. A carbon phenolic heat shield material is utilized and tailored to accommodate each of the probe missions. An integral heat shield approach is selected over in order to eliminate a high temperature interface problem and permit direct bonding of the carbon phenolic to the structural honeycomb sandwich. The sandwich is filled with a very fine powder to minimize degradation of its insulation properties by the high conductive hydrogen/helium gases during the long atmospheric descent phase.

Mezines, S.↗

Thermal Systems Modeling of Chemical Integrated Power Source (CHIPS) to Survive Lunar Night Environments

This paper presents the results of the systems level thermal modeling for a conceptual Chemical Heat Integrated Power Source (CHIPS). This proposed system offers a combined thermal and electrical power source to support survival of spacecraft operating in extreme low temperature lunar environments, without the use of radioisotope-based sources. A conceptual design study has been completed for this system, that uses heat generated by an exothermic chemical reaction in place of radioisotope or electrical heat sources. The goal of the study was to evaluate the feasibility of such as system through thermodynamic and chemical analysis and thermal modeling, and to identify technology gaps to inform a technology development and maturation plan. The specific technical objectives focused on delivery of 90-100 Wth thermal power and 30-40 We electrical power for 336 hours to a representative Commercial Lunar Payload Services (CLPS) lander, to support lunar surface survival and limited operations through a lunar night. The total system mass was targeted at ≤50 kg. A highly exothermic chemical reaction system is used to generate on-board electrical power for spacecraft systems, and thermal power to maintain critical spacecraft/lander systems within their allowable flight temperature (AFTs). Based on the very high energy content of the chemical reaction system, a much higher amount of heat per unit mass can be delivered to the spacecraft, relative to a rechargeable lithium-ion battery and electrical heater(s). Since radioisotope heaters or generators are not used, the system will be orders of magnitude lower in cost than a radioisotope heating/power unit, without the attendant regulatory complexities. As part of the CHIPS concept, a fraction of the thermal power generated is converted to electrical power via an appropriate thermal-to-electric converter technology (such as a free piston Stirling converter or a thermoelectric generator module), to provide power to critical loads. This approach is ideally suited to support operation of commercial landers (e.g., via the CLPS program). In most cases, these landers are only designed to operate during a portion of the lunar day, with no provision for survival through the lunar night. By supporting lunar night survival, a mission can be extended through the lunar night and at least into another lunar day, thus turning a nominal eight-day mission into a 36-day mission. Therefore, the current system demonstration will focus on scalability to support at least 336 hours (one lunar night) of continuous thermal and electrical power generation. Although initially targeted to support lunar equatorial landings, the technology is extensible to missions at the lunar poles, other extreme environments in the Solar System or even air-independent applications on Earth (e.g., ocean exploration).

West, William↗

Heat Pump Water Heater Technology Assessment Based on Laboratory Research and Energy Simulation Models: Preprint

This paper explores the laboratory performance of five integrated Heat Pump Water Heaters (HPWHs) across a wide range of operating conditions representative of US climate regions. Laboratory results demonstrate the efficiency of this technology under most of the conditions tested and show that differences in control schemes and design features impact the performance of the individual units. Theseresults were used to understand current model limitations, and then to bracket the energy savings potential for HPWH technology in various US climate regions. Simulation results show that HPWHs are expected to provide significant energy savings in many climate zones when compared to other types of water heaters (up to 64%, including impact on HVAC systems).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Unitized Regenerative Fuel Cell System Gas Storage/Radiator Development

The ancillary components for Unitized Regenerative Fuel Cell (URFC) Energy Storage System are being developed at the NASA Glenn Research Center. This URFC system is unique in that it uses the surface area of the hydrogen and oxygen storage tanks as radiating heat surfaces for overall thermal control of the system. The waste heat generated by the URFC stack during charging and discharging is transferred from the cell stack to the surface of each tank by loop heat pipes. The heat pipes are coiled around each tank and covered with a thin layer of thermally conductive layer of carbon composite. The thin layer of carbon composite acts as a fin structure that spreads the heat away from the heat pipe and across the entire tank surface. Two different sized commercial grade composite tanks were constructed with integral heat pipes and tested in a thermal vacuum chamber to examine the feasibility of using the storage tanks as system radiators. The storage radiators were subjected to different steady-state heat loads and varying heat load profiles. The surface emissivity and specific heat capacity of each tank were calculated. The results were incorporated into a model that simulates the performance of similar radiators using lightweight, space rated carbon composite tanks.

Jakupca, Ian↗