Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heat Flux”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Observations of Subduction, Downward Heat Flux and Dense Filament Collapse in the Northern Gulf of Mexico

Submesoscale processes are important contributors to the global heat budget and generally support upward heat transport through restratification. However, in salinity‐stratified regions, such as the northern Gulf of Mexico with its influx of freshwater from the Mississippi‐Atchafalaya river system, temperature can act like a passive tracer and submesoscale processes can contribute to downward heat transport. Oceanic heat content is a factor in many environmental risks the region faces, for example, hurricane intensification, and marine heatwaves. During the 2022 field campaign of the Submesoscales Under Near‐Resonant Inertial Shear Experiment, a sampling plan was developed to study such submesoscale processes in high resolution. Over 31 hr, four assets (two research ships and two remotely controlled boats) drove in parallel across a dense filament, capturing its evolution in time and space. The observations show that surface waters, warmed by daytime solar radiation, were subducted and that the associated overturning circulation transported heat below the surface layer where it was later irreversibly mixed away. The estimated downward heat flux was as strong as the concurrent net air‐sea heat flux into the ocean. The filament was then observed to rapidly collapse which we attribute to boundary layer turbulence and the breakdown of geostrophic balance. The collapsing fronts display behaviors indicative of gravity currents. These observations highlight how in salinity‐stratified regions, frontal dynamics can be associated with downward heat flux and how the submesoscale can play an important role in the oceanic heat budget.

58 GEOSCIENCES↗

The effects of surface heat flux on plume spread and concentration - An assessment based on remote measurements

Satellite-derived surface heat-flux maps are presented in order to illustrate the large horizontal variations in surface heating that can occur over heterogeneous terrain. Results of plume-model studies published by Lamb (1978) and Willis and Deardorff (1978) were modified to show that the ground-level pollutant concentration depend closely upon the surface heat flux for the case of an elevated plume source during periods of free convection. It is suggested that remotely determined surface heat-flux patterns can be used in making plume dispersion calculations.

Carlson, T. N.↗

The effect of oxidation on the high heat flux behavior of a thermal barrier coating

The effect of oxidation on the high heat flux behavior of a thermal barrier coating was evaluated by cyclically exposing preoxidized specimens to a 3000 C nitrogen plasma. The thermal barrier coatings consisted of a 0.025 cm layer of air-plasma-sprayed ZrO2-7 percent Y2O3 and a 0.012 cm layer of low pressure-plasma-sprayed NiCoCrAlY applied over 0.13 cm diameter B1900+Hf cylindrical substrates. A gradient of 800 C is produced across the ceramic layer in each 0.5 second exposure. This is much more severe than the gradient encountered on a gas turbine engine. Prior to exposure, the specimens were preoxidized at 1200 C for time from 0 to 20 hours. These coatings were found to be tolerant to the high heat flux plasma flame for all but the most severe preoxidations. However, life degraded rapidly for preoxidation times in excess of 15 hours at 1200 C. A log-log plot of cycles-to-failure vs estimated oxidative weight gain yield a straight or nearly straight line, and this line could be rationalized using an oxidation-based model that was developed previously for low heat flux applications.

Miller, Robert A.↗

Infrared radiometric technique for rapid quantitative evaluation of heat flux distribution over large areas

This paper describes a novel approach for rapid, quantitative measurement of spatially distributed heat flux incident on a plane. The technique utilizes the spatial temperature distribution on an opaque thin film at the location of interest, as measured by an imaging infrared radiometer. Knowledge of film radiative properties, plus quantitative estimates of convection cooling permit the steady state energy balance at any location on the film sheet to be solved for the incident heat flux. Absolute accuracies on the order of 10-15 percent have been obtained in tests performed in air. The method is particularly useful for evaluation of spatial heat flux uniformity from distributed heat sources over large areas. It has recently been used in several applications at the Jet Propulsion Laboratory, including flux uniformity measurements from large distributed quartz lamp arrays used during thermal vacuum testing of several spacecraft components, and flux mapping of a low power NdYg laser beam.

Glazer, Stuart↗

Evidence for ion heat flux in the light ion polar wind

Cold flowing hydrogen and helium ions have been observed using the retarding ion mass spectrometer on board the Dynamics Explorer 1 spacecraft in the dayside magnetosphere at subauroral latitudes. The ions show a marked flux asymmetry with respect to the relative wind direction. The observed data are fitted by a model of drifting Maxwellian distributions perturbed by a first order-Spritzer-Haerm heat flux distribution function. It is shown that both ion species are supersonic just equatorward of the auroral zone at L = 14, and the shape of asymmetry and direction of the asymmetry are consistent with the presence of an upward heat flux. At L = 6, both species evolve smoothly into warmer subsonic upward flows with downward heat fluxes. In the case of subsonic flows the downward heat flux implies a significant heat source at higher altitudes. Spin curves of the spectrometer count rate versus the spin phase angle are provided.

Biddle, A. P.↗

Design, fabrication, and testing of a water-cooled tungsten-foam high-heat flux plasma-facing module

Here, we present a comprehensive study detailing the design, fabrication and testing a new modular “finger” component, featuring a hexagonal tungsten foam armor tile bonded to the top surface of the water-cooled finger unit. The mechanical, thermal, and particle transport properties of the tungsten foam armor were determined for a wide range of porosity and cell size, and then combined in an equivalent solid material with “effective” properties suitable for large-scale simulations. A series of 3-D multiphysics simulations for coupled thermal and mechanical behavior of the “finger” module are used to optimize the design before fabrication. The simulation results show that, for the expected experimental conditions, a safe range of heat flux and foam porosity is possible for both water-cooling and helium-cooling. Based on these multiphysics simulations, an optimum finger cooling module has been fabricated at Ultramet, Inc. A series of experiments were designed to study the thermomechanical performance of the “finger” unit under steady-state and transient thermal loading at surface heat flux up to 16 MW/m 2 in the High Energy Flux Test facility (HEFTY) at UCLA. Testing conditions included low-power, steady-state plasma exposure at 6 MW/m 2 , followed by severe high heat flux cycles at 16 MW/m 2 . Results of these tests are explained through comparisons with multiphysics simulations. To eliminate the effects of thermomechanical damage carried out on a module on its thermo-mechanical response on a subsequent test, three different yet identically designed and fabricated finger modules were tested. The results show that the current design is capable of cooling the walls of fusion devices at surface heat flux up to 6 MW/m 2 without failure, and that the failure heat flux limit is below 16 MW/m 2 .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evidence of vapor shielding effect on heat flux loaded on flowing liquid lithium limiter in EAST

For this study, a lithium (Li) vapour layer was formed around a flowing liquid Li limiter to shield against the plasma incident power and reduce limiter heat flux in the EAST tokamak. The results revealed that after a plasma operation of a few seconds, the layer became clear, which indicated a strong Li emission with a decrease in the limiter surface temperature. This emission resulted in a dense vapour around the limiter, and Li ions moved along the magnetic field to form a green shielding layer on the limiter. The plasma heat flux loaded on the limiter, measured by the probe installed on the limiter, was approximately 52% lower than that detected by a fast-reciprocating probe at the same radial position without the limiter in EAST. Additionally, approximately 42% of the parallel heat flux was dissipated directly with the enhanced Li radiation in the discharge with the liquid metal infused trenches (LIMIT) limiter. This observation revealed that the Li vapour layer exhibited an excellent shielding effect to liquid Li on plasma heat flux, which is a possible benefit of liquid-plasma-facing components in future fusion devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental feasibility study of a thermoelectric heat flux gage

An experiment was conducted to determine the feasibility of using a commercially available thermoelectric device as a heat flux gage at near ambient conditions. In certain research applications, the thermoelectric heat flux gage can provide a relatively simple means to model a warm fluid cold wall convection environment. The experiment showed that heat flux through the gage could be correlated within 2.5 percent with a simple algebraic equation which considered the thermoelectric current through the device and the hot and cold side temperatures.

Vanfossen, G. J.↗

Dependence of the boundary heat flux width on core and edge profiles in Alcator C-Mod

This work presents new evidence that the heat flux width, λ q , in the Alcator C-Mod tokamak scales with the edge electron pressure, as observed in the ASDEX Upgrade (AUG) tokamak, but the scaling with volume-averaged pressure, $\bar{p}$, from the plasma stored energy, is a better predictor of λ q in Alcator C-Mod than the edge electron pressure. These previous studies, which find that λ q decreases with increasing plasma pressure, imply that a high performance core at high pressure will lead to challenging heat and particle exhaust due to very small λ q . This concern has led to our significant enlargement of the C-Mod database with the electron density, temperature, and pressure profile data from the Thomson scattering and electron cyclotron emission diagnostics. Using the C-Mod database augmented with new profile data, we find that λ q decreases with increasing edge electron pressure as ${\lambda }_{q}\propto {p}_{\mathrm{e},95}^{-0.26}$, similar to results from AUG, and showing the strength of cross-machine comparisons. We also find that ${\lambda }_{q}\propto {p}_{\mathrm{e},\mathrm{c}\mathrm{o}\mathrm{r}\mathrm{e}}^{-0.56}$, consistent with the original finding from C-Mod that the heat flux width scales as ${\bar{p}}^{-0.48}$. The scalings of λ q with separatrix pressure and gradient scale length are found to match the AUG results qualitatively. The C-Mod scalings with edge plasma quantities have more scatter than the $\bar{p}$ scaling, and, importantly, show different trends for H-modes relative to L- and I-mode. Furthermore, investigating the source of this discrepancy presents an opportunity for further study that may improve our ability to predict the heat flux width in different confinement scenarios in the pursuit of optimizing core-edge performance in future reactors.

Alcator C-Mod↗

Comparison of Heat Flux Gages for High Enthalpy Flows - NASA Ames and IRS

This article is a companion to a paper on heat flux measurements as initiated under a Space Act Agreement in 2011. The current focus of this collaboration between the Institute of Space Systems (IRS) of the University of Stuttgart and NASA Ames Research Center is the comparison and refinement of diagnostic measurements. A first experimental campaign to test different heat flux gages in the NASA Interaction Heating Facility (IHF) and the Plasmawindkanaele (PWK) at IRS was established. This paper focuses on the results of the measurements conducted at IRS. The tested gages included a at face and hemispherical probe head, a 4" hemispherical slug calorimeter, a null-point calorimeter from Ames and a null-point calorimeter developed for this purpose at IRS. The Ames null-point calorimeter was unfortunately defective upon arrival. The measured heat fluxes agree fairly well with each other. The reason for discrepancies can be attributed to signal-to-noise levels and the probe geometry.

spacecraft reentry↗

First Wall Design of a Tokamak Pilot Plant Using a Monte Carlo Model for 3-D Heat Flux Deposition

We present a method for calculating the heat fluxes deposited on nonaxisymmetric tokamak first wall components, allowing for a first-of-its-kind model for power handling in the tokamak far scrape-off layer (SOL). The DIV3D Monte Carlo model features strict global power conservation and can calculate the finite cross-field plasma transport into magnetically-shadowed regions, which is significant when dealing with meter-scale shadows introduced by components such as poloidal limiters or antennas. As a case study, we apply the DIV3D model to inform the distribution of first wall poloidal limiters in an ARC-class reactor device. We demonstrate that discrete protection limiters can efficiently reduce peak heat fluxes on recessed breeder wall components in the presence of significant far-SOL plasma fluxes. By varying the toroidal periodicity and radial standoff depth of the limiters, we demonstrate one of the tradeoffs that must be considered in first wall design: more limiters provide greater protection, but at the cost of reduced breeding performance. We also present the impact that radial misalignments between limiters would have on first wall power loading.

Monte Carlo methods↗

Thermal Conductivity of Advanced Ceramic Thermal Barrier Coatings Determined by a Steady-state Laser Heat-flux Approach

The development of low conductivity and high temperature capable thermal barrier coatings requires advanced testing techniques that can accurately and effectively evaluate coating thermal conductivity under future high-performance and low-emission engine heat-flux conditions. In this paper, a unique steady-state CO2 laser (wavelength 10.6 microns) heat-flux approach is described for determining the thermal conductivity and conductivity deduced cyclic durability of ceramic thermal and environmental barrier coating systems at very high temperatures (up to 1700 C) under large thermal gradients. The thermal conductivity behavior of advanced thermal and environmental barrier coatings for metallic and Si-based ceramic matrix composite (CMC) component applications has also been investigated using the laser conductivity approach. The relationships between the lattice and radiation conductivities as a function of heat flux and thermal gradient at high temperatures have been examined for the ceramic coating systems. The steady-state laser heat-flux conductivity approach has been demonstrated as a viable means for the development and life prediction of advanced thermal barrier coatings for future turbine engine applications.

Zhu, Dong-Ming↗

Plasma-arc lamp high heat flux cycling exposure of neutron irradiated tungsten materials

Thick plate, unalloyed W was neutron irradiated in the High Flux Isotope Reactor (HFIR) at 550 °C to a fast fluence of 1.24 × 10 25 n m -2 E > 0.1 MeV (~0.24 dpa). Unirradiated and irradiated specimens of the material were high heat flux (HHF) tested in the Plasma Arc Lamp (PAL) facility. The PAL uses a high-power photon source to provide a broad and even heat distribution on the sample surface. To simulate on/off cycling of normal operating plasma, the samples were exposed to approximately 800 cycles at 4.73 MW m -2 absorbed heat flux (incident heat fluxes of 10.95 MW m -2 ). Additionally, after PAL exposure, slight changes were observed on the surfaces of the samples with SEM. The samples showed some annealing in the near surface polished region, but they were all below the damage threshold for cracking or other destructive features. The PAL has a large parameter space for future testing. The use of the HFIR and PAL to sequentially expose neutron irradiated samples to HHF will be a powerful tool for understanding materials behavior in a fusion-like environment.

36 MATERIALS SCIENCE↗

Analysis of the Effects of Vitiates on Surface Heat Flux in Ground Tests of Hypersonic Vehicles

To achieve the high enthalpy conditions associated with hypersonic flight, many ground test facilities burn fuel in the air upstream of the test chamber. Unfortunately, the products of combustion contaminate the test gas and alter gas properties and the heat fluxes associated with aerodynamic heating. The difference in the heating rates between clean air and a vitiated test medium needs to be understood so that the thermal management system for hypersonic vehicles can be properly designed. This is particularly important for advanced hypersonic vehicle concepts powered by air-breathing propulsion systems that couple cooling requirements, fuel flow rates, and combustor performance by flowing fuel through sub-surface cooling passages to cool engine components and preheat the fuel prior to combustion. An analytical investigation was performed comparing clean air to a gas vitiated with methane/oxygen combustion products to determine if variations in gas properties contributed to changes in predicted heat flux. This investigation started with simple relationships, evolved into writing an engineering-level code, and ended with running a series of CFD cases. It was noted that it is not possible to simultaneously match all of the gas properties between clean and vitiated test gases. A study was then conducted selecting various combinations of freestream properties for a vitiated test gas that matched clean air values to determine which combination of parameters affected the computed heat transfer the least. The best combination of properties to match was the free-stream total sensible enthalpy, dynamic pressure, and either the velocity or Mach number. This combination yielded only a 2% difference in heating. Other combinations showed departures of up to 10% in the heat flux estimate.

Cuda, Vincent↗

Moisture and latent heat flux variabilities in the tropical Pacific derived from satellite data

This paper describes a method of determining latent heat flux and the ocean-atmosphere moisture from sea surface temperature, precipitable water, and surface wind speed data derived from 1980-1983 observations of SMMR aboard Nimbus 7 above tropical Pacific. The observation period included a very intense El Nino-Southern Oscillation (ENSO) episode. It was found that, during the early phase of the 1982-1983 ENSO, a surface convergence center moved east leading the anomalous equatorial westerlies. At this center, the low wind and high humidity caused negative (low) latent heat flux anomalies, despite anomalously high sea surface temperatures. Latent heat flux was found to play an important role in the seasonal cooling of the upper ocean, except in areas covered by major surface convergence zones and in areas of ocean upwelling.

Liu, W. Timothy↗

Material Plasma Exposure eXperiment High Heat Flux Microwave Absorber Design, Manufacture, and Articles Test

The Material Plasma Exposure eXperiment (MPEX) at Oak Ridge National Laboratory is in the final design phase. MPEX will be capable of exposing neutron-irradiated materials to plasmas for the study of plasma-material interaction. This facility will provide information about the complex effects of plasmas on materials and contribute to examining new materials that can withstand high heat fluxes and high ion fluences for future fusion devices. MPEX plasma is heated by 70-GHz or 105-GHz electron Bernstein wave/electron cyclotron heating (ECH), and the high-frequency microwaves are prone to scattering microwave power, which can have detrimental effects, especially on diagnostic components. A large portion of the injected ECH power is expected to be absorbed by plasma, but the remainder requires that microwave absorbers be placed immediately upstream and downstream of the ECH launcher to minimize stray microwaves leaving the ECH region. These microwaves can inadvertently heat components that cannot be shielded or otherwise protected. The microwave absorber design is based on an array of pyramid-shaped ceramic tiles brazed to a water-cooled explosion-bonded heat sink and a stainless steel plate to produce one tile module. Computational fluid dynamics and structural analyses were performed to optimize and validate the design. Multiple test coupons were produced to validate the process for brazing the two different tile materials to the Glidcop AL-15 baseplate. The articles were tested to evaluate the reliability and thermal performance through exposure to an electron beam with a heat flux of up to 1.5 MW/m2. Nondestructive testing was performed before and after testing to identify voids or separations that may have been introduced by the high heat flux. This paper discusses the details of high heat flux microwave absorber design, manufacturing details and associated challenges, and test results, demonstrating the effectiveness of the proposed design.

Hussain, Aftab↗

Spray Cooling Trajectory Angle Impact Upon Heat Flux Using a Straight Finned Enhanced Surface

Experiments were conducted to study the effects of spray trajectory angles upon heat flux for flat and enhanced surface spray cooling. The surface enhancement consisted of straight fins machined on the top surface of a copper heater block. Spray cooling curves were obtained with the straight fin surface aligned both parallel (axial) and perpendicular (transverse) to the spray axis. Measurements were also obtained on a flat surface heater block for comparison purposes. Each copper block had a cross-sectional area of 2.0 sq cm. A 2x2 nozzle array was used with PF-5060 as the working fluid. Thermal performance data was obtained under nominally degassed (chamber pressure of 41.4 kPa) conditions. Results show that the maximum CHF in all cases was attained for a trajectory angle of 30' from the surface normal. Furthermore, trajectory angles applied to straight finned surfaces can have a critical heat flux (CHF) enhancement as much as 75% (heat flux value of 140 W/sq cm) relative to the vertical spray orientation for the analogous flat surface case under nominally degassed conditions.

Silk, Eric A.↗