Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Grid Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Power grid frequency prediction using spatiotemporal modeling

Understanding power system dynamics is essential for interarea oscillation analysis and the detection of grid instabilities. The FNET/GridEye is a GPS-synchronized wide-area frequency measurement network that provides an accurate picture of the normal real-time operational condition of the power system-dynamics, giving rise to new and intricate spatiotemporal patterns of power loads. We propose to model FNET/GridEye grid frequency data from the U.S. Eastern Interconnection with a spatiotemporal statistical model. We predict the frequency data at locations without observations, a critical need during disruption events where measurement data are inaccessible. Spatial information is accounted for either as neighboring measurements in the form of covariates or with a spatiotemporal correlation model captured by a latent Gaussian field. Finally, the proposed method is useful in estimating power system dynamic response from limited phasor measurements and holds promise for predicting instability that may lead to undesirable effects such as cascading outages.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Machine Learning-based Intrusion Detection for Smart Grid Computing: A Survey

Machine learning (ML)-based intrusion detection system (IDS) approaches have been significantly applied and advanced the state-of-the-art system security and defense mechanisms. In smart grid computing environments, security threats have been significantly increased as shared networks are commonly used, along with the associated vulnerabilities. However, compared to other network environments, ML-based IDS research in a smart grid is relatively unexplored, although the smart grid environment is facing serious security threats due to its unique environmental vulnerabilities. In this article, we conducted an extensive survey on ML-based IDS in smart grids based on the following key aspects: (1) The applications of the ML-based IDS in transmission and distribution side power components of a smart power grid by addressing its security vulnerabilities; (2) dataset generation process and its usage in applying ML-based IDSs in the smart grid; (3) a wide range of ML-based IDSs used by the surveyed papers in the smart grid environment; (4) metrics, complexity analysis, and evaluation testbeds of the IDSs applied in the smart grid; and (5) lessons learned, insights, and future research directions.

SCADA↗

Fine Temperature Grid Continuous Energy Cross Section Generation for Monte Carlo Analysis of Xe-100 Design

The standard “A Compact ENDF (ACE)” data libraries used by Monte Carlo based reactor physics codes calculations are provided by Los Alamos National Laboratory (LANL) with a temperature interval mostly of 300 K (e.g. 300 K, 600 K, 900 K) for the cross sections and between 100 K and 200 K for the thermal scattering libraries (TSL). However, some codes such as MCNP lack capability to perform on-the-fly temperature interpolation during simulation both for neutron and TSL cross-sections. To evaluate the impact related to Doppler broadening and spectrum shift associated with TSL changes, this paper explores the potential of adopting a temperature grid finer than the ones contained in the standard data libraries. A 50 K temperature grid was employed to quantify the error in neutronics calculations due to temperature grid resolution. This was achieved by comparing the results of this study (50 K temperature interval) against the results obtained with standard data libraries (>100 K temperature interval). While the adopted grid primarily relies on the ENDF/B-VII.1 library, for neutron cross-sections, it utilizes ENDF/B-VIII.0 library for TSL. The analyses confirmed that the accuracy of neutronics calculations is satisfactory when using a 50 K temperature grid. Notably, adopting a 50 K temperature grid, as opposed to standard libraries or coarser temperature grids, could lead to a difference of no more than a few hundred pcm in dk for both fresh fuel and burnt fuel. The most sensitive reaction type to the temperature grid was as expected identified as the capture cross-section of U-238.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Investigation of thermal hydraulic behavior of the High Temperature Test Facility's lower plenum via large eddy simulation

A high-fidelity computational fluid dynamics (CFD) analysis was performed using the Large Eddy Simulation (LES) model for the lower plenum of the High–Temperature Test Facility (HTTF), a ¼ scale test facility of the modular high temperature gas-cooled reactor (MHTGR) managed by Oregon State University. In most next–generation nuclear reactors, thermal stress due to thermal striping is one of the risks to be curiously considered. This is also true for HTGRs, especially since the exhaust helium gas temperature is high. In order to evaluate these risks and performance, organizations in the United States led by the OECD NEA are conducting a thermal hydraulic code benchmark for HTGR, and the test facility used for this benchmark is HTTF. HTTF can perform experiments in both normal and accident situations and provide high-quality experimental data. However, it is difficult to provide sufficient data for benchmarking through experiments, and there is a problem with the reliability of CFD analysis results based on Reynolds–averaged Navier–Stokes to analyze thermal hydraulic behavior without verification. To solve this problem, high-fidelity 3-D CFD analysis was performed using the LES model for HTTF. It was also verified that the LES model can properly simulate this jet mixing phenomenon via a unit cell test that provides experimental information. As a result of CFD analysis, the lower the dependency of the sub-grid scale model, the closer to the actual analysis result. In the case of unit cell test CFD analysis and HTTF CFD analysis, the volume-averaged sub-grid scale model dependency was calculated to be 13.0% and 9.16%, respectively. As a result of HTTF analysis, quantitative data of the fluid inside the HTTF lower plenum was provided in this paper. As a result of qualitative analysis, the temperature was highest at the center of the lower plenum, while the temperature fluctuation was highest near the edge of the lower plenum wall. The power spectral density of temperature was analyzed via fast Fourier transform (FFT) for specific points on the center and side of the lower plenum. FFT results did not reveal specific frequency-dominant temperature fluctuations in the center part. It was confirmed that the temperature power spectral density (PSD) at the top increased from the center to the wake. The vortex was visualized using the well-known scalar Q-criterion, and as a result, the closer to the outlet duct, the greater the influence of the mainstream, so that the inflow jet vortex was dissipated and mixed at the top of the lower plenum. Additionally, FFT analysis was performed on the support structure near the corner of the lower plenum with large temperature fluctuations, and as a result, it was confirmed that the temperature fluctuation of the flow did not have a significant effect near the corner wall. In addition, the vortices generated from the lower plenum to the outlet duct were identified in this paper. It is considered that the quantitative and qualitative results presented in this paper will serve as reference data for the benchmark.

97 MATHEMATICS AND COMPUTING↗

Valuation of Hydrogen Technology on the Electric Grid Using Production Cost Modeling: Cooperative Research and Development Final Report, CRADA Number CRD-18-00736

This research project will estimate the value to the United States electric grid of deploying hydrogen technology (such as electrolyzers and hydrogen-fueled generation) under projected conditions of high renewable penetration. The analysis will advance the state of the art in systems-level cost-benefit analysis of hydrogen technology for the electric grid by incorporating production cost modeling results in the analysis. Large-scale grid simulation tools will be used to evaluate total system production cost and grid operation when hydrogen technology is deployed for applications such as energy storage and demand response. Scenarios will include one or more future grid mixes in the Western Interconnect (WI) with a high proportion of intermittent renewables. Electric Power Research Institute (EPRI) will work with four utility companies to refine scenarios. Results of the analysis will include comparing the net cost of hydrogen to other technologies for long duration storage, and of power-to-gas (P2G) scenarios including merchant hydrogen sale and hydrogen-fueled generation.

08 HYDROGEN↗

State Requirements for Electric Distribution System Planning

Utilities have conducted distribution planning since they first began building and operating electricity systems. But filing these plans for regulatory and stakeholder review is a relatively recent phenomenon. This report summarizes legislative and regulatory requirements for regulated electric utilities to file some type of distribution system plan in 20 U.S. jurisdictions. Some plans focus on expedited cost recovery for certain types of distribution system improvements; other plans focus on investments for grid modernization or distributed energy resources. Increasingly, states are adopting requirements for Integrated Distribution Plans. Such plans provide holistic grid investment strategies that address state and local policies and increasing complexity at the grid edge. The report covers the following topics for distribution system plans, highlighting advanced practices: -State goals and objectives -Procedural requirements -Forecasting loads and distributed energy resources -Hosting capacity analysis -Baseline information requirements -Grid modernization strategy -Grid needs assessment -Non-wires solutions -Reliability and resilience analyses -Stakeholder engagement -Equity -Pilots -Coordination with other planning processes The report includes links to legislation; regulatory requirements, proceedings, and orders; and filed utility plans. The U.S. Department of Energy’s Office of Electricity provided funding support.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Vis-SAGA: Visual Analytics for Situational Awareness of Grid Anomalies: Preprint

We describe supporting near real-time situational awareness of the electric distribution system by visualizing novel data from voltage sensors deployed on existing broadband cable television network equipment. Our scalable web-based visual analytics platform supports interactive geospatial exploration, time-series analysis, and summarization of grid behavior during potentially anomalous events. The broadband cable television sensor network provides observability of the electrical distribution system at a higher local spatial resolution than is typically available to most utilities, revealing the operational state of the network and aiding in the detection of abnormal behaviors or deviations from expected patterns, particularly across electric utility service areas. We outline the design and development of interactive geospatial and time-series visualization components and the scalable data services that supply metadata, historical, and real-time streams of sensor data across the network. We evaluate our platform during periods of extreme weather, demonstrating its ability to assist in detecting patterns of operation that affect power availability, quality, resiliency, and service restoration.

cable television↗

Mechanism Analysis of Wind Turbine Var Oscillations

Electromagnetic transient simulation of parallel connected 4-MW type-3 wind turbines based on original equipment manufacturer's real-code turbine model shows 1.2-Hz turbine-turbine oscillations in reactive power. This letter reveals why such oscillations occur in the individual var measurement, while being insignificant in the total var measurement, regardless of the varying grid impedance. We adopt two analysis approaches: open-loop single-input single-output analysis and network decomposition. The two approaches differ in their treatment of turbine-network interaction. The open-loop analysis shows that the turbine-turbine oscillation mode is due to an open-loop system pole being attracted to an open-loop system zero. Furthermore, we use network decomposition method to explain why this mode is observable in individual vars while not observable in the total var. The entire system of n -turbines can be viewed as n decoupled circuits. For the two-turbine case, the system has an aggregated mode and a turbine-turbine oscillation mode. Here, the aggregated mode is associated with a circuit associated with the total var, while the turbine-turbine oscillation mode is associated with the var difference and is insensitive to the grid parameters.

17 WIND ENERGY↗

Fault Contribution of Grid-Following and Grid-Forming Inverters Considering Generic Inverter Controls and Ride-through Requirements

Gradual transformation of the synchronous generator (SG)-dominated power systems to inverter-based resource (IBR)-dominated power systems is bringing new challenges regarding power system protection. Increasing IBR’s penetration will reduce the reliability of protection coordination, originally developed for SG-dominated power systems, potentially leading to less accurate calculation or even mis-operation. Thus, new protection schemes compatible with IBR-dominated power systems should be established. Prior to establishing the protection schemes, research on the fault contribution of generic IBR models should be conducted considering interconnection requirements. This paper conducts fault current contribution analysis of generic grid-following (GFL) and grid-forming (GFM) inverters considering interconnection requirements using an electromagnetic transient (EMT) simulation tool. To do this, EMT-based generic GFL models have been developed with the ride-through requirements from IEEE-1547 standards. In addition, the major functions of the generic models are explained. Then, the fault current analysis was conducted using GFL and GFM inverters in a single-inverter-infinite-bus system and a modified IEEE 34-node system considering different grid, fault, inverter control parameters.

Kim, Jinho [BATTELLE (PACIFIC NW LAB)]↗

Quantitative analysis of cost savings and occupants’ preferences in grid-interactive smart home operation

Many utility companies in the United States have introduced time-of-use (TOU) rates for homeowners with the goal of regulating electricity consumption during peak hours. The electrical appliances in homes include various thermostatically controlled devices, such as air conditioners (AC) for thermal comfort, and nonthermostatically controlled devices such as clothes washers. As a result, homeowners face the complicated challenge of economically operating multiple electrical appliances in their homes while maintaining comfort and convenience. This is usually due to the lack of an explicit understanding of the correlation between cost saving and the users’ comfort. To understand the correlation, this article is designed to construct a framework by integrating three major components: a multi-objective optimization method accommodating multiple competing goals with different weights, a learning-based system modeling approach describing the dynamics and thermal coupling effects of appliances, and a novel comfort index method differentiating preferred and acceptable thermal comfort. Our proposed framework can allow the indoor air temperature to fall into the "preferred" range with a marginal cost increase. Furthermore, the simulation result shows that an additional 8 h for the preferred thermal comfort can be achieved with a cost increase of only 1.77%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

How will United States commercial building energy use be impacted by IPCC climate scenarios?

Climate change and anthropogenically-forced shift of weather in the future will impact energy use and resilience of both the built environment and the electric grid. The aim of this analysis is to understand how future climate scenarios will impact electricity and natural gas use of commercial buildings in the United States. Here, this study analyzes this impact for 2030, 2045, and 2100 using Representative Concentration Pathways (RCP) scenarios defined in Intergovernmental Panel on Climate Change (IPCC) Assessment Report 5. The large, gridded simulation of meteorological variables for RCPs 2.6, 4.5, 6.0, and 8.5 are selected and downscaled to make available hourly Future Meteorological Year (FMY) weather files for use and improvement in subsequent studies. High performance computing resources use these FMYs to simulate commercial prototype buildings in every American Society of Heating, Refrigeration, and Air Conditioning Engineers (ASHRAE) climate zone of the United States (US), and results are scaled to nation-wide energy use using conditioned floor area multipliers. The analysis is conducted without speculating the physical and performance traits of future buildings or the grid characteristics. This analysis quantifies the impact of climate change on source electrical and natural gas usage for commercial buildings in the United States over the next 80 years. If US commercial floorspace remained constant, total energy use by 2100 is predicted between an 1.75% decrease under the greatest emission scenario (8.5) and a 1.76% increase under the lowest emission scenario (2.6). When adjusted for anticipated urban growth by 2100, the predicted range is 65% increase (8.5) and 71% increase (2.6). Under a global temperature rise climate scenario, the warmest US climate zones will see a large increases in electricity use derived from space cooling while the coldest US climate zones will see significant decreases in natural gas use caused by the decrease in heating necessary. While climate change may ultimately require adaptations of the built environment to withstand its effects and because the United States is a country that requires more heating than cooling, from a building energy perspective, climate change (average temperature rise) is a net energy saver for the United States.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

GPU-resident sparse direct linear solvers for alternating current optimal power flow analysis

Integrating renewable resources within the transmission grid at a wide scale poses significant challenges for economic dispatch as it requires analysis with more optimization parameters, constraints, and sources of uncertainty. This motivates the investigation of more efficient computational methods, especially those for solving the underlying linear systems, which typically take more than half of the overall computation time. In this paper, we present our work on sparse linear solvers that take advantage of hardware accelerators, such as graphical processing units (GPUs), and improve the overall performance when used within economic dispatch computations. We treat the problems as sparse, which allows for faster execution but also makes the implementation of numerical methods more challenging. We present the first GPU-native sparse direct solver that can execute on both AMD and NVIDIA GPUs. We demonstrate significant performance improvements when using high-performance linear solvers within alternating current optimal power flow (ACOPF) analysis. Furthermore, we demonstrate the feasibility of getting significant performance improvements by executing the entire computation on GPU-based hardware. Finally, we identify outstanding research issues and opportunities for even better utilization of heterogeneous systems, including those equipped with GPUs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy Efficient, Cost-Effective Power and Co-Generation Technologies: Techno-Environmental Analysis

Development of energy solutions for addressing grid resiliency and energy efficiency while lowering greenhouse gas emissions is critical in today’s energy scenario. Chemical energy provides on demand power. Cogeneration technologies offer numerous benefits in meeting the growing energy demand while lowering the impact on environment. Utilization of waste heat from prime movers in conjunction with energy efficient heat pumps and renewable photovoltaics is an attractive approach. Efficient utilization of available resources to support current and future building energy needs targeting grid resiliency, energy and environmental security via co-generation approaches is the focus of this study. A detailed techno-environmental analysis of hybrid system configurations consisting of conventional and emerging technologies utilizing natural gas, electric grid, and renewable power resources along with heat recovery systems and heat pump technologies are analyzed and presented. The key objective is to present integrated system configurations and thermodynamic analysis of various co-generation systems suitable for providing building energy. Design solutions targeting low carbon footprint and high energy efficiency are presented.

Cheekatamarla, Praveen↗

Exploring Grid-Interactive Efficient Building Strategies for Laboratories Through Energy Modeling

Laboratories are often overlooked in demand flexibility research due to constraints on their operations as mission critical facilities, despite the major role they play in an organization's emissions. Laboratories consume 3-4 times more energy than a typical office building and are commonly the largest energy users on any campus. Consequently, most laboratories in the United States are significant contributors to their organization's carbon footprint if their energy needs are met through the combustion of fossil fuels. As part of the initiative to decarbonize laboratories, this report documents an analysis on specifically grid-interactive efficient building (GEB) opportunities for reducing energy costs and emissions associated with laboratory operations. The goal of this initiative was to provide a case study and guidance on how to use OpenStudio and REopt as modeling tools for GEB technologies and strategies in laboratory environments across different climate zones in the United States. The analysis found that efficiency-based GEB strategies had the most significant impact on laboratory operations, while load-shedding and load-shifting GEB strategies produced smaller results. The culmination of these approaches applied across all five climate zones generated on average: 1) 28% energy cost savings and 30% greenhouse gas (GHG) emissions reductions, and 2) 4% enhanced energy cost savings under a time-of-use (TOU) pricing schedule compared to traditional pricing schemes. Grid-interactive efficiency building measures were found to produce the greatest energy savings in both electricity and natural gas, particularly in regions with high electrical loads, such as warm climates for cooling. Laboratories that had high levels of natural gas consumption, meanwhile, experienced the greatest emission reductions. The report concludes with an analysis on the opportunities for flexible loads in lab spaces and how small-scale measures in addition to opaque pricing structures for peak demand could become barriers to demand flexibility planning. The report also explores how electrifying laboratory buildings with heat pumps could reduce energy costs and GHG emissions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Measuring the muon content of inclined air showers using AERA and the water-Cherenkov detectors of the Pierre Auger Observatory

We present a novel approach for assessing the muon content of air showers with large zenith angles on a combined analysis of their radio emission and particle footprint. We use the radiation energy reconstructed by the Auger engineering radio array (AERA) as an energy estimator and determine the muon number independently with the water-Cherenkov detector array of the Pierre Auger Observatory, deployed on a 1500 m grid. We focus our analysis on air showers with primary energy above 4 EeV to ensure full detection efficiency. Over approximately ten years of accumulated data, we identify a set of 40 high-quality events that are used in the analysis. The estimated muon contents in data are compatible with those for iron primaries as predicted by current-generation hadronic interaction models. This result can be interpreted as a deficit of muons in simulations as a lighter mass composition has been established from X max measurements. This muon deficit was already observed in previous analyses of the Auger Collaboration and is confirmed using hybrid events that include radio measurements for the first time.

Abdul Halim, A. [Adelaide U.]↗