Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Gas sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Procedure for analysis of nickel-cadmium cell materials

Quality control procedures include analyses on electrolyte, active materials, and separators for nickel cadmium cell materials. Tests range from the visual/mechanical inspection of cells to gas sampling, electrolyte extract, electrochemical tests, and physical measurements.

Halpert, G.↗

Design development and test: Two-gas atmosphere control subsystem

An atmosphere control subsystem (ACS) was developed for NASA-IBJSC which is designed to measure the major atmospheric constituents in the manned cabin of the space shuttle orbiter and control the addition of oxygen and nitrogen to maintain the partial pressures of these gases within very close limits. The ACS includes a mass spectrometer sensor (MSS) which analyzes the atmosphere of a shuttle vehicle pressurized cabin, and an electronic control assembly (ECA). The MSS was built and tested to meet the requirements for flight equipment for the M-171 Metabolic Analyzer experiment for the Skylab flight program. The instrument analyzes an atmospheric gas sample and produces continuous 0-5 vdc analog signals proportional to the partial pressures of H2, O2, N2, H2O, CO2 and total hydrocarbons having a m/e ratio between 50 and 120. It accepts signals from the MSS proportional to the partial pressures of N2 and O2 and controls the supply of these gases to the closed cabin.

Jackson, J. K.↗

Temperature measurements behind reflected shock waves in air

A radiometric method for the measurement of gas temperature in self-absorbing gases has been applied in the study of shock tube generated flows. This method involves making two absolute intensity measurements at identical wavelengths, but for two different pathlengths in the same gas sample. Experimental results are presented for reflected shock waves in air at conditions corresponding to incident shock velocities from 7 to 10 km/s and an initial driven tube pressure of 1 torr. These results indicate that, with this technique, temperature measurements with an accuracy of + or - 5 percent can be carried out. The results also suggest certain facility related problems.

Bader, J. B.↗

Gaseous exhaust emissions from a J-58 engine at simulated supersonic flight conditions

Emissions of total oxides of nitrogen, unburned hydrocarbons, carbon monoxide, and carbon dioxide from a J-58 engine at simulated flight conditions of Mach 2.0, 2.4, and 2.8 at 19.8 km altitude are reported. For each flight condition, measurements were made for four engine power levels from maximum power without afterburning through maximum afterburning. These measurements were made 7 cm downstream of the engine primary nozzle using a single point traversing gas sample probe. Results show that emissions vary with flight speed, engine power level, and with radial position across the exhaust.

Holdeman, J. D.↗

Emission calibration of a J-58 afterburning turbojet engine at simulated supersonic stratospheric flight conditions

Emissions of total oxides of nitrogen, unburned hydrocarbons, and carbon monoxide from a J-58 engine at simulated flight conditions of Mach 2.0, 2.4, and 2.8 at 19.8 km altitude are reported. For each flight condition, measurements were made for four engine power levels from maximum power without afterburning through maximum afterburning. These measurements were made 7 cm downstream of the engine primary nozzle using a single point traversing gas sample probe. Results show that emissions vary with flight speed, engine power level, and with radial position across the exhaust.

Holdeman, J. D.↗

Supersonic combustion of hydrogen injected perpendicular to a ducted vitiated airstream

The reaction of hydrogen injected into a supersonic vitiated airstream from perpendicular injectors equally spaced over opposite walls of a two-dimensional duct is experimentally investigated. Information is obtained in the form of pitot pressure and gas sample surveys of the duct exit flow and static pressures along the duct walls for several injector arrangements differing in number, spacing, and size of injectors and operating at two levels of equivalence ratio. The amount of the injected hydrogen reacted is deduced from the static pressure data using a one-dimensional theory and is correlated with relative injection pressure and injector spacing-to-diameter ratio. These results are used with a mixing distribution correlation derived from nonreacting hydrogen-air results to predict static pressure distributions.

Rogers, R. C.↗

Application of a radiometric method to the measurement of temperature in self-absorbing gases

A radiometric method for the measurement of gas temperature in self-absorbing gases has been applied in the study of shock-tube-generated flows. This method involves making two absolute-intensity measurements at the same wavelength in a specified gas sample, but using two different path lengths. Experimental results are presented for reflected shock waves in air and in xenon at conditions corresponding to shock velocities from 4 to 10 km/sec and an initial driven tube pressure of 1 torr. These results indicate that, with the technique, temperature measurements with an accuracy of 5% can be carried out. The measurements in air suggest certain facility-related problems, and results obtained in the application of this measurement technique to the investigation of these problems and to the study of radiative cooling phenomena in both air and xenon are presented.

Nerem, R. M.↗

Measurement techniques for supersonic combustion testing

Measurement techniques used during nine years of intensive research in supersonic combustion are presented. The tests employed a number of combustor and injector configurations, which were directly connected to a Mach 3.2 supersonic nozzle, and both gaseous hydrogen and storable liquid fuels. Nominal plenum conditions for the arc-heated air were 3000 to 4500 R and 30 atm. Measurements included wall surface pressures, wall temperatures, heat flux, skin friction, instream cone-static and pitot pressures, and gas samples. Measurement and analysis techniques have been developed for determining total enthalpy of an airstream containing NO concentrations in excess of equilibrium using the two-throat technique, bulk combustion efficiency using steam calorimetry, radial gradients of fluid properties in the combustor exit plane using a stream tube method, and wall shear from measurements of heat transfer in a reacting supersonic flow using Reynolds analogy.

Orth, R. C.↗

Turbine gas temperature measurement and control system

A fluidic Turbine Inlet Gas Temperature (TIGIT) Measurement and Control System was developed for use on a Pratt and Whitney Aircraft J58 engine. Based on engine operating requirements, criteria for high temperature materials selection, system design, and system performance were established. To minimize development and operational risk, the TIGT control system was designed to interface with an existing Exhaust Gas Temperature (EGT) Trim System and thereby modulate steady-state fuel flow to maintain a desired TIGT level. Extensive component and system testing was conducted including heated (2300F) vibration tests for the fluidic sensor and gas sampling probe, temperature and vibration tests on the system electronics, burner rig testing of the TIGT measurement system, and in excess of 100 hours of system testing on a J58 engine. (Modified author abstract)

Webb, W. L.↗

Interference of oxygen, carbon dioxide, and water vapor on the analysis for oxides of nitrogen by chemiluminescence

The interference of small concentrations (less than 4 percent by volume) of oxygen, carbon dioxide, and water vapor on the analysis for oxides of nitrogen by chemiluminescence was measured. The sample gas consisted primarily of nitrogen, with less than 100 parts per million concentration of nitric oxide, and with small concentrations of oxygen, carbon dioxide, and water vapor added. Results obtained under these conditions indicate that although oxygen does not measurably affect the analysis for nitric oxide, the presence of carbon dioxide and water vapor causes the indicated nitric oxide concentration to be too low. An interference factor - defined as the percentage change in indicated nitric oxide concentration (relative to the true nitric oxide concentration) divided by the percent interfering gas present - was determined for carbon dioxide to be -0.60 + or - 0.04 and for water vapor to be -2.1 + or - 0.3.

Maahs, H. G.↗

Air pollution from aircraft

A model which predicts nitric oxide and carbon monoxide emissions from a swirl can modular combustor is discussed. A detailed analysis of the turbulent fuel-air mixing process in the swirl can module wake region is reviewed. Hot wire anemometry was employed, and gas sampling analysis of fuel combustion emissions were performed.

Heywood, J. B.↗

Gaseous exhaust emissions from a JT8D-109 turbofan engine at simulated cruise flight conditions

Gaseous emissions from a JT8D-109 turbofan engine were measured in an altitude facility at four simulated cruise flight conditions: Mach 0.8 at altitudes of 9.1, 10, 7, and 12.2 km and Mach 0.9 at 10.7 km. Engine inlet air temperature was held constant at 283 K for all tests. Emissions measurements were made at nominally 6 cm intervals across the horizontal diameter of the engine exhaust nozzle with a single-point traversing gas sample probe. Measured emissions of decreased with increasing altitude from an emission index of 10.4 to one of 8.3, while carbon monoxide increased with increasing altitude from an emission index of 1.6 to one of 4.4. Unburned hydrocarbon emissions were essentially negligible for all flight conditions. Since the engine inlet air temperatures were not correctly simulated, the NOx emission indices were corrected to true altitude conditions by using correlating parameters for changes in combustor inlet temperature, pressure, and temperature rise. The correction was small at the lowest altitude. At the 10.7 and 12.2 km, Mach 0.8 test conditions the correction decreased the measured values by 1 emission index.

Diehl, L. A.↗

Emission calibration of a J-58 afterburning turbojet engine at simulated supersonic, stratospheric flight conditions

Emissions of total oxides of nitrogen, unburned hydrocarbons, and carbon monoxide from a J-58 engine at simulated flight conditions of Mach 2.0, 2.4, and 2.8 at 19.8 km altitude are reported. For each flight condition, measurements were made for four engine power levels from maximum power without afterburning through maximum afterburning. These measurements were made 7 cm downstream of the engine primary nozzle using a single point traversing gas sample probe. Results show that emissions vary with flight speed, engine power level, and with radial position across the exhaust.

Holdeman, J. D.↗

Development of Skylab medical equipment and flight preparations

The major medical systems in the Skylab orbital workshop are described. They comprise the food system, the waste management system, operational bioinstrumentation, personal hygiene, gas sampling, an inflight medical support system, and a cardiovascular counterpressure garment. Life sciences experiments carried out aboard Skylab are also reviewed; these include an ergometer and metabolic analyzer, a lower-body negative pressure device, an electrode harness and body temperature probe, a blood pressure cuff, a leg volume measuring band, sleep studies, a body-mass measuring device, a rotating litter chair, a blood sample processor, and small-mass measuring apparatus. All performance requirements were met with the equipment, and no failures were encountered.

Johnston, R. S.↗

Spectral radiance measurements and calculated soot concentrations along the length of an experimental combustor

Radiometric data were obtained over a range of parametric test conditions at three positions along the length of an experimental combustor segment corresponding to the primary, intermediate, and dilution zones. The concentration of soot entrained in the combustion gases was calculated by a technique using spectral radiance measurements. Tests were conducted primarily with Jet A fuel, although limited data were taken with two fuels having higher aromatic content, diesel oil number 2 and a blend of 40 percent tetralin in Jet A fuel. Radiometric observation of the combustion gases indicated that the maximum total radiance peaked at the intermediate zone, which was located immediately upstream of the dilution holes. Soot concentrations calculated from optical measurements in the dilution zone compared favorably with those obtained by in situ gas sampling at the exhaust. The total radiance increased with the higher aromatic content fuels.

Norgren, C. T.↗

Integrated Real Time Contamination Monitor IRTCM

Engineering and design work was performed on a monitoring device for particulate and gas contamination to be used in the space shuttle cargo area during launch at altitudes up to 50 km and during return phases of the flight. The gas sampling device consists of ampules filled with specific absorber materials which are opened and/or sealed at preprogrammed intervals. The design eliminates the use of valves which, according to experiments, are never sealing properly at hard vacuum. Methods of analysis including in-flight measuring possibilities are discussed.

Luttges, W. E.↗

Comments on unmixedness

Unmixedness in flames refers to the condition in which eddies of fuel and oxidant have engulfed each other but where the molecular mixing necessary for complete reaction has not taken place. This phenomenon is studied experimentally using a flow geometry consisting of a coaxial Mach 2 hydrogen jet surrounded by a parallel cold Mach 2 air stream. Gas sample measurements taken downstream in the region near the flame revealed the presence of unreacted hydrogen and oxygen in the same sample. The data were analyzed by means of the CHARNAL program which uses a step function variation with time for instantaneous concentration.

Eggers, J. M.↗