Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Gas sample analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Microbial Gas Generation Under Expected Waste Isolation Pilot Plant Repository Conditions: Final Report

Gas generation from the microbial degradation of the organic constituents of transuranic (TRU) waste under conditions expected in the Waste Isolation Pilot Plant (WIPP) was investigated. The biodegradation of mixed cellulosic materials and electron-beam irradiated plastic and rubber materials (polyethylene, polyvinylchloride, hypalon, leaded hypalon, and neoprene) was examined. We evaluated the effects of environmental variables such as initial atmosphere (air or nitrogen), water content (humid ({approx}70% relative humidity, RH) and brine inundated), and nutrient amendments (nitogen phosphate, yeast extract, and excess nitrate) on microbial gas generation. Total gas production was determined by pressure measurement and carbon dioxide (CO{sub 2}) and methane (CH{sub 4}) were analyzed by gas chromatography; cellulose degradation products in solution were analyzed by high-performance liquid chromatography. Microbial populations in the samples were determined by direct microscopy and molecular analysis. The results of this work are summarized.

03 NATURAL GAS↗

TURBULENCE AND STAR FORMATION IN A SAMPLE OF SPIRAL GALAXIES

We investigate turbulent gas motions in spiral galaxies and their importance to star formation in far outer disks, where the column density is typically far below the critical value for spontaneous gravitational collapse. Following the methods of Burkhart et al. on the Small Magellanic Cloud, we use the third and fourth statistical moments, as indicators of structures caused by turbulence, to examine the neutral hydrogen (H i) column density of a sample of spiral galaxies selected from The H i Nearby Galaxy Survey. We apply the statistical moments in three different methods—the galaxy as a whole, divided into a function of radii and then into grids. We create individual grid maps of kurtosis for each galaxy. To investigate the relation between these moments and star formation, we compare these maps with their far-ultraviolet images taken by the Galaxy Evolution Explorer satellite.We find that the moments are largely uniform across the galaxies, in which the variation does not appear to trace any star-forming regions. This may, however, be due to the spatial resolution of our analysis, which could potentially limit the scale of turbulent motions that we are sensitive to greater than ∼700 pc. From comparison between the moments themselves, we find that the gas motions in our sampled galaxies are largely supersonic. This analysis also shows that the Burkhart et al. methods may be applied not just to dwarf galaxies but also to normal spiral galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

Reduction Behavior of Dolomite-Fluxed Magnetite: Coke Composite Pellets at 1573 K (1300 °C)

High-temperature behavior of magnetite—coke composite pellet fluxed with dolomite was investigated by customized thermogravimetric analyzer (TGA) at 1573 K (1300 °C). The overall reaction was influenced by C/O ratio and dolomite content. The reduction was accelerated by increased amount of dolomite, while the samples with higher C/O ratio showed the improved reduction degree. X-ray diffraction (XRD) pattern of reduced pellet showed the phase changes of the iron oxides. Noticeable iron peaks were observed when the sample reached the final stage of reduction. CO and CO{sub 2} gases released from the reaction were measured by Infrared (IR) gas analyzer. Relation between enhanced reducibility of pellets and larger CO gas evolution from the Boudouard reaction was confirmed from the analysis. Compressive strengths were studied for the practical assessment of reduced pellets. Samples with low-reduction degree showed better physical property. Excessive amount of dolomite also deteriorated the integrity of pellets.

36 MATERIALS SCIENCE↗

Phenomenological Model of Nonlinear Dynamics and Deterministic Chaotic Gas Migration in Bentonite: Experimental Evidence and Diagnostic Parameters

Understanding gas migration in compacted clay materials, e.g., bentonite and claystone, is important for the design and performance assessment of an engineered barrier system of a radioactive waste repository system, as well as many practical applications. Existing field and laboratory data on gas migration processes in low-permeability clay materials demonstrate the complexity of flow and transport processes, including various types of instabilities, caused by nonlinear dynamics of coupled processes of liquid–gas exchange, dilation, fracturing, fracture healing, etc., which cannot be described by classical models of fluid dynamics in porous media. We here show that the complexity of gas migration processes can be explained using a phenomenological concept of nonlinear dynamics and deterministic chaos theory. To do so, we analyzed gas pressure and gas influx (i.e., input) and outflux (i.e., output), recorded during the gas injection experiment in the compact Mx80-D bentonite sample, and calculated a set of the diagnostic parameters of nonlinear dynamics and chaos, such a global embedding dimension, a correlation dimension, an information dimension, and a spectrum of Lyapunov exponents, as well as plotted 2D and 3D pseudo-phase-space strange attractors, based on the univariate influx and outflux time series data. These results indicate the presence of phenomena of low-dimensional deterministic chaotic behavior of gas migration in bentonite. In particular, during the onset of gas influx in the bentonite core, before the breakthrough, the development of gas flow pathways is characterized by the process of chaotic gas diffusion. After the breakthrough, with inlet-to-outlet movement of gas, the prevailing process is chaotic advection. During the final phase of the experiment, with no influx to the sample, the relaxation pattern of gas outflux is resumed back to a process of chaotic diffusion. The types of data analysis and a proposed phenomenological model can be used to establish the basic principles of experimental data-gathering, modeling predictions, and a research design.

36 MATERIALS SCIENCE↗

Selective solid-phase microextraction of explosives using fibers coated with the La (III) complex of p-di (4,4,5,5,6,6,6-hepafluoro-1,3-hexanediony) benzene

This research demonstrates enhanced capture of explosives on polydimethylsiloxane (PDMS) solid-phase microextraction (SPME) fibers coated with a metal beta-diketonate polymer, [La(III) complex of p-di(4,4,5,5,6,6,6-heptafluoro-1,3-hexanedionyl)benzene, La(dihed)], compared to PDMS control fibers. SPME sampling was performed in an explosives bunker where the concentration of 2,4,6-trinitrotoluene (TNT) was estimated at less than 3 parts-per-trillion (v/v). Analysis by gas chromatography/mass spectrometry showed an approximate ten-fold enhancement in the quantity of 2,4-dinitrotoluene captured on La(dihed) over the control fiber. La(dihed) sampling also resulted in a strong signal for TNT, whereas this explosive was well below the detection limit (1 pg on fiber) on the control fiber.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Monitor for measuring mercury emissions

A mercury emissions monitor includes a mercury sensor tape configured to be fed in a reel-to-reel manner between first and second tape reels, wherein the mercury sensor tape includes a thin metallic film configured to form an amalgam with detected mercury. A mercury collection unit is configured to receive into a chamber a sample of a gas containing mercury, wherein the mercury collection unit is further configured to permit passage of portions of the mercury sensor tape through the chamber containing the gas sample so that the amalgam is formed with the thin metallic film. A mercury analysis unit includes a total reflection x-ray fluorescence (“TXRF”) system configured to perform a TXRF analysis of the amalgam, wherein the mercury analysis unit is configured to permit passage of the mercury sensor tape within a proximity of an XRF detector of the TXRF system. The mercury collection unit and the mercury analysis unit are positioned between the first and second tape reels so that the mercury sensor tape can move in a continuous manner from the first tape reel through the chamber of the mercury collection unit, then within sufficient proximity to the XRF detector, to be then taken up onto the second tape reel.

Kumar, Nalin↗

The extended family of hexagonal molybdenum oxide

Over the last 40 years, a large number of isostructural compounds in the system MoO{sub 3}-NH{sub 3}-H{sub 2}O have been published. The reported molecular formulae of 'hexagonal molybdenum oxide' (HEMO) varied from MoO{sub 3}, MoO{sub 3} {center_dot} 0.33NH{sub 3}, MoO{sub 3} {center_dot} nH{sub 2}O (0.09 {le} n {le} 0.69) to MoO{sub 3} {center_dot} mNH{sub 3} {center_dot} nH{sub 2}O (0.09 {le} m {le} 0.20; 0.18 {le} n {le} 0.60). Samples, prepared by the acidification route, were investigated using thermal analysis coupled on-line to a mass spectrometer for evolved gas analysis; X-ray powder diffraction; Fourier Transform Infrared, Raman and Magic-Angle-Spinning {sup 1}H-NMR spectroscopy; Incoherent Inelastic Neutron Scattering. The X-ray study of a selected monocrystal confirmed the presence of the well-known framework of edge-sharing MoO{sub 6} octahedra: Space group P6{sub 3}/m, a = 10.527(1), c =3.7245(7) {angstrom}, {gamma} = 120{sup o}. The structure of the synthesized samples can best be described by the structural formula (NH{sub 4})[Mo{sub x}{open_square}{sub 1/2+p/2}(O{sub 3x + 1/2-p/2})(OH){sub p}] {center_dot} yH{sub 2}O (x 5.9-7.1; p {approx} 0.1; y = 1.2-2.6), which is consistent with the existence of one vacancy for 12-15 molybdenum sites. The 'chimie douce' reaction of MoO{sub 3} {center_dot} 0.155NH{sub 3} {center_dot} 0.440H{sub 2}O with a 1:1 mixture of NO/NO{sub 2} at 100 C resulted in the synthesis of MoO{sub 3} {center_dot} 0.539H{sub 2}O. Tailored nano-sized molybdenum powders can be produced using HEMO as precursor.

36 MATERIALS SCIENCE↗

Analysis of chemical warfare agents by gas chromatography-mass spectrometry: methods for their direct detection and derivatization approaches for the analysis of their degradation products

Abstract Chemical warfare agents (CWAs) are unarguably one of the most feared toxic substances produced by mankind. Their inception in conventional warfare can be traced as far back as the Middle Ages but their full breakthrough as central players in bellic conflicts was not realized until World War I. Since then, more modern CWAs along with efficient methods for their manufacture have emerged and violently shaped the way modern warfare and diplomatic relations are conducted. Owing to their mass destruction ability, counter methods to mitigate their impact appeared almost immediately on par with their development. These efforts have focused on their efficient destruction, development of medical countermeasures and their detection by modern analytical chemistry methods. The following review seeks to provide the reader with a broad introduction on their direct detection by gas chromatography-mass spectrometry (GC-MS) and the various sample derivatization methods available for the analysis of their degradation products. The review concentrates on three of the main CWA classes and includes the nerve agents, the blistering agents and lastly, the incapacitating agents. Each section begins with a brief introduction of the CWA along with discussions of reports dealing with their detection in the intact form by GC-MS. Furthermore, as products arising from their degradation carry as much importance as the agents themselves in the field of forensic analysis, the available derivatization methods of these species are presented for each CWA highlighting some examples from our lab in the Forensic Science Center at the Lawrence Livermore National Laboratory.

Valdez, Carlos A.↗

Air Sample Conditioner Helps the Waste Treatment Plant Meet Emissions Standards

The air in three of the Hanford Site Waste Treatment and Immobilization Plant (WTP) melter off-gas discharge stacks will be hot and humid after passing through the train of emission abatement equipment. The off-gas temperature and humidity levels will be incompatible with the airborne emissions monitoring equipment required for this type of stack. To facilitate sampling from these facilities, an air sample conditioner system will be installed to introduce cool, dry air into the sample stream to reduce the temperature and dew point. This will avoid thermal damage to the instrumentation and problematic condensation. The complete sample transport system must also deliver at least 50% of the particles in the sample airstream to the sample collection and on-line analysis equipment. The primary components of the sample conditioning system were tested in a laboratory setting. The sample conditioner itself is based on a commercially-available porous tube filter design. It consists of a porous sintered metal tube inside a coaxial metal jacket. The hot gas sample stream passes axially through the porous tube, and the dry, cool air is injected into the jacket and through the porous wall of the inner tube, creating an effective sample diluter. The dilution and sample air mix along the entire length of the porous tube, thereby simultaneously reducing the dew point and temperature of the mixed sample stream. Furthermore, because the dilution air enters through the porous tube wall, the sample stream does not come in contact with the porous wall and particle deposition is reduced in this part of the sampling system. Tests were performed with an environmental chamber to supply air with the temperature and humidity needed to simulate the off-gas conditions. Air from the chamber was passed through the conditioning system to test its ability to reduce the temperature and dew point of the sample stream. To measure particle deposition, oil droplets in the range of 9 to 11 micrometer aerodynamic diameter were injected into the environmental chamber and drawn through the conditioning system, which included a filter to capture droplets that passed through the conditioner. The droplets were tagged with a fluorescent dye which allowed quantification of droplet deposition on each component of the system. The tests demonstrated the required reductions in temperature and moisture, with no condensation forming when heat tracing was added on the upstream end of the sample conditioner. Additionally, tests indicated that the system, operating at several flow rates and in both vertical and horizontal orientations, delivers nearly all of the sampled particles for analysis. Typical aerosol penetration values were between 98 and 99%. PNNL, Bechtel National Inc., and the instrument vendor are working to implement the sample conditioner into the air monitoring systems used for the melter off-gas exhaust streams. Similar technology may be useful for processes in other facilities with air exhaust streams with elevated temperature and/or humidity.

sample conditioning↗

Conditioning and Requalification of Legacy Waste Packages - 18648

In most German interim storage facilities, hundreds of waste packages are waiting for re-conditioning and qualification to comply with the waste acceptance criteria (WAC) for the Konrad repository. Especially the waste classification as well as some characteristics and the description of the material composition in its current state do not comply with the Konrad requirements since the conditioning of these waste packages took place up to 40 years ago. The German name for these waste packages is 'Altgebinde', hereafter referred to as 'legacy waste packages'. The present article will provide an overview of the measures for the qualification of these legacy waste packages to fulfill the Konrad requirements. The following measures, when necessary, are carried out for the qualification of legacy waste packages: - Collection and evaluation of all documents related to the primary conditioning process, e. g. the used equipment, documented waste and packaging properties, conditioning and radiology, if available (hereafter 'old documents'). - Preparation of a conceptual report and a process control quality plan based on existing data, with appropriate measures to qualify the waste packages. Assessment and approval of the process control quality plan by the competent authority. - Characterization of the waste and packaging properties by visual inspection or tomography, recording or updating of dose rate, contamination and mass, verification of product stability, for example by gas analysis of the interior atmosphere of the container. - Characterization of the nuclide inventory by gammas scans, sample taking to analyze nuclides which can not be measured by means of in-situ gamma spectrometry, and for material declaration. - Qualification or post-conditioning of the legacy waste packages if necessary, e. g. by drying the waste packages and packaging them in containers approved for disposal. - Compilation of all results of the above mentioned tests and steps to create a waste package documentation, including the calculations for the nuclide inventory and the description of the material composition of the waste packages. - Receiving approval by the competent authority after evaluation of the final documentation. The aim behind this structured approach is to prevent additional, unnecessary measures and treatment of the waste. Consequently, the additional characterization is preferably carried out on the basis of the available documents. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Experimental Setup to Investigate Hydrogen Isotope Retention on Powder Samples as Slag/Dust Proxies for Advanced Fusion Reactors

Slag/dust formation is one of the critical issues regarding tritium retention in advanced fusion reactors. We upgraded an ultrahigh vacuum device, the sample exposure station (SES), to perform temperature-programmed desorption (TPD), also known as thermal desorption spectroscopy, to investigate deuterium (D) retention in powder samples that are utilized as proxies for slag/dust particles formed in fusion reactors. TPD analysis, calibrated for the desorption rate, was successfully performed on commercially available crystalline/amorphous boron (B) powder after D 2 neutral gas or D + ion exposure. We calibrated the B powder temperature measurement for TPD analysis utilizing a D 2 desorption peak from B-D bonding known for its desorption temperature ~700 K. We introduce a separation procedure of observed D TPD signals, convoluted for corresponding D retention pathways, that was necessary for TPD analysis. This is the first report on the retention of D 2 neutral gas to B, and this observation was enabled by utilizing the B powder sample, which has a larger surface area than films commonly used in laboratory experiments. In conclusion, the upgraded SES system will enable us to investigate hydrogen isotope behaviors for powder/dust samples of various elemental compositions, including metals.

Plasma-facing component debris↗

Multivariate analysis of progressive thermal desorption coupled gas chromatography-mass spectrometry.

Thermal decomposition of poly dimethyl siloxane compounds, Sylgard{reg_sign} 184 and 186, were examined using thermal desorption coupled gas chromatography-mass spectrometry (TD/GC-MS) and multivariate analysis. This work describes a method of producing multiway data using a stepped thermal desorption. The technique involves sequentially heating a sample of the material of interest with subsequent analysis in a commercial GC/MS system. The decomposition chromatograms were analyzed using multivariate analysis tools including principal component analysis (PCA), factor rotation employing the varimax criterion, and multivariate curve resolution. The results of the analysis show seven components related to offgassing of various fractions of siloxanes that vary as a function of temperature. Thermal desorption coupled with gas chromatography-mass spectrometry (TD/GC-MS) is a powerful analytical technique for analyzing chemical mixtures. It has great potential in numerous analytic areas including materials analysis, sports medicine, in the detection of designer drugs; and biological research for metabolomics. Data analysis is complicated, far from automated and can result in high false positive or false negative rates. We have demonstrated a step-wise TD/GC-MS technique that removes more volatile compounds from a sample before extracting the less volatile compounds. This creates an additional dimension of separation before the GC column, while simultaneously generating three-way data. Sandia's proven multivariate analysis methods, when applied to these data, have several advantages over current commercial options. It also has demonstrated potential for success in finding and enabling identification of trace compounds. Several challenges remain, however, including understanding the sources of noise in the data, outlier detection, improving the data pretreatment and analysis methods, developing a software tool for ease of use by the chemist, and demonstrating our belief that this multivariate analysis will enable superior differentiation capabilities. In addition, noise and system artifacts challenge the analysis of GC-MS data collected on lower cost equipment, ubiquitous in commercial laboratories. This research has the potential to affect many areas of analytical chemistry including materials analysis, medical testing, and environmental surveillance. It could also provide a method to measure adsorption parameters for chemical interactions on various surfaces by measuring desorption as a function of temperature for mixtures. We have presented results of a novel method for examining offgas products of a common PDMS material. Our method involves utilizing a stepped TD/GC-MS data acquisition scheme that may be almost totally automated, coupled with multivariate analysis schemes. This method of data generation and analysis can be applied to a number of materials aging and thermal degradation studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of Halogen-Mercury Reactions in Flue Gas

Oxidized mercury species may be formed in combustion systems through gas-phase reactions between elemental mercury and halogens, such as chorine or bromine. This study examines how bromine species affect mercury oxidation in the gas phase and examines the effects of mixtures of bromine and chlorine on extents of oxidation. Experiments were conducted in a bench-scale, laminar flow, methane-fired (300 W), quartz-lined reactor in which gas composition (HCl, HBr, NO{sub x}, SO{sub 2}) and temperature profile were varied. In the experiments, the post-combustion gases were quenched from flame temperatures to about 350 C, and then speciated mercury was measured using a wet conditioning system and continuous emissions monitor (CEM). Supporting kinetic calculations were performed and compared with measured levels of oxidation. A significant portion of this report is devoted to sample conditioning as part of the mercury analysis system. In combustion systems with significant amounts of Br{sub 2} in the flue gas, the impinger solutions used to speciate mercury may be biased and care must be taken in interpreting mercury oxidation results. The stannous chloride solution used in the CEM conditioning system to convert all mercury to total mercury did not provide complete conversion of oxidized mercury to elemental, when bromine was added to the combustion system, resulting in a low bias for the total mercury measurement. The use of a hydroxylamine hydrochloride and sodium hydroxide solution instead of stannous chloride showed a significant improvement in the measurement of total mercury. Bromine was shown to be much more effective in the post-flame, homogeneous oxidation of mercury than chlorine, on an equivalent molar basis. Addition of NO to the flame (up to 400 ppmv) had no impact on mercury oxidation by chlorine or bromine. Addition of SO{sub 2} had no effect on mercury oxidation by chlorine at SO{sub 2} concentrations below about 400 ppmv; some increase in mercury oxidation was observed at SO{sub 2} concentrations of 400 ppmv and higher. In contrast, SO{sub 2} concentrations as low as 50 ppmv significantly reduced mercury oxidation by bromine, this reduction could be due to both gas and liquid phase interactions between SO{sub 2} and oxidized mercury species. The simultaneous presence of chlorine and bromine in the flue gas resulted in a slight increase in mercury oxidation above that obtained with bromine alone, the extent of the observed increase is proportional to the chlorine concentration. The results of this study can be used to understand the relative importance of gas-phase mercury oxidation by bromine and chlorine in combustion systems. Two temperature profiles were tested: a low quench (210 K/s) and a high quench (440 K/s). For chlorine the effects of quench rate were slight and hard to characterize with confidence. Oxidation with bromine proved sensitive to quench rate with significantly more oxidation at the lower rate. The data generated in this program are the first homogeneous laboratory-scale data on bromine-induced oxidation of mercury in a combustion system. Five Hg-Cl and three Hg-Br mechanisms, some published and others under development, were evaluated and compared to the new data. The Hg-halogen mechanisms were combined with submechanisms from Reaction Engineering International for NO{sub x}, SO{sub x}, and hydrocarbons. The homogeneous kinetics under-predicted the levels of mercury oxidation observed in full-scale systems. This shortcoming can be corrected by including heterogeneous kinetics in the model calculations.

54 ENVIRONMENTAL SCIENCES↗

DISSOLUTION OF NEPTUNIUM OXIDE RESIDUES

This report describes the development of a dissolution flowsheet for neptunium (Np) oxide (NpO{sub 2}) residues (i.e., various NpO{sub 2} sources, HB-Line glovebox sweepings, and Savannah River National Laboratory (SRNL) thermogravimetric analysis samples). Samples of each type of materials proposed for processing were dissolved in a closed laboratory apparatus and the rate and total quantity of off-gas were measured. Samples of the off-gas were also analyzed. The quantity and type of solids remaining (when visible) were determined after post-dissolution filtration of the solution. Recommended conditions for dissolution of the NpO{sub 2} residues are: Solution Matrix and Loading: {approx}50 g Np/L (750 g Np in 15 L of dissolver solution), using 8 M nitric acid (HNO{sub 3}), 0.025 M potassium fluoride (KF) at greater than 100 C for at least 3 hours. Off-gas: Analysis of the off-gas indicated nitric oxide (NO), nitrogen dioxide (NO{sub 2}) and nitrous oxide (N{sub 2}O) as the only identified components. No hydrogen (H{sub 2}) was detected. The molar ratio of off-gas produced per mole of Np dissolved ranged from 0.25 to 0.4 moles of gas per mole of Np dissolved. A peak off-gas rate of {approx}0.1 scfm/kg bulk oxide was observed. Residual Solids: Pure NpO{sub 2} dissolved with little or no residue with the proposed flowsheet but the NpCo and both sweepings samples left visible solid residue after dissolution. For the NpCo and Part II Sweepings samples the residue amounted to {approx}1% of the initial material, but for the Part I Sweepings sample, the residue amounted to {approx}8 % of the initial material. These residues contained primarily aluminum (Al) and silicon (Si) compounds that did not completely dissolve under the flowsheet conditions. The residues from both sweepings samples contained minor amounts of plutonium (Pu) particles. Overall, the undissolved Np and Pu particles in the residues were a very small fraction of the total solids.

08 HYDROGEN↗

A Method for Rapid and Precise Triple Oxygen Isotope Measurements via High-Temperature Conversion to CO Followed by Nickel-Catalyzed CO to CO 2 Conversion and Laser Spectroscopy

Triple oxygen isotopic compositions ( 16 O, 17 O, 18 O) have conventionally been measured via isotope ratio mass spectrometry using O 2 as an analyte. Conversion of sample oxygen to O 2 typically utilizes fluorination chemistry or catalytic equilibration between CO 2 and O 2 . Recently, laser spectroscopy has become a viable alternative for triple oxygen isotope (Δ' 17 O) measurements due to its ease and rapid throughput. Laser spectrometers are currently available for Δ' 17 O analysis of either H 2 O or CO 2 as the analyte gas. So far, these instruments have been used to measure Δ' 17 O of water, carbonate (CO 2 liberated by acid digestion), and atmospheric CO 2 samples. Here, we present a new method for high-precision Δ' 17 O analysis of CO 2 via tunable infrared laser direct absorption spectroscopy that is compatible with a wider range of geochemically important materials. This approach involves converting sample oxygen to CO 2 in two steps. First, the sample oxygen is liberated and reduced to CO by high-temperature conversion at 1450 °C in the presence of excess elemental carbon. Then, CO is catalytically converted to CO 2 over hot nickel at 350 °C. The conversion process is rapid (10 to 30 min) and quantitative. Spectroscopic Δ' 17 O analysis of the resulting CO 2 takes approximately 45 min. By measuring several oxygen isotope standards, we demonstrate that the method is precise (1σ = 12 per meg for procedural replicates) and accurate (within 11 per meg of previously reported values). The method can be applied to most pyrolytic materials where quantitative oxygen conversion is attainable, such as sulfate, phosphate, nitrate, and oxide minerals, water, and organic molecules.

Ellis, Nicholas M. [University of California, Berk↗

Gas cell for in situ soft X-ray transmission-absorption spectroscopy of materials

A simple gas cell design, constructed primarily from commercially available components, enables in situ soft X-ray transmission-absorption spectroscopy of materials in contact with gas at ambient temperature. The cell has a minimum X-ray path length of 1 mm and can hold gas pressures up to ~300 Torr, and could support higher pressures with simple modifications. The design enables cycling between vacuum and gas environments without interrupting the X-ray beam, and can be fully sealed to allow for measurements of air-sensitive samples. The cell can attach to the downstream port of any appropriate synchrotron beamline, and offers a robust and versatile method for in situ measurements of certain materials. The construction and operation of the cell are discussed, as well as sample preparation and proper spectral analysis, illustrated by examples of spectral measurements. Potential areas for improvement and modification for specialized applications are also mentioned.

47 OTHER INSTRUMENTATION↗

Quantitative hydrogen analysis of zircaloy-4 in laser-induced breakdown spectroscopy with ambient helium gas

This experiment was carried out to address the need for overcoming the difficulties encountered in hydrogen analysis by means of plasma emission spectroscopy in atmospheric ambient gas. The result of this study on zircaloy-4 samples from a nuclear power plant demonstrates the possibility of attaining a very sharp emission line from impure hydrogen with a very low background and practical elimination of spectral contamination of hydrogen emission arising from surface water and water vapor in atmospheric ambient gas. This was achieved by employing ultrapure ambient helium gas as well as the proper defocusing of the laser irradiation and a large number of repeated precleaning laser shots at the same spot of the sample surface. Further adjustment of the gating time has led to significant reduction of spectral width and improvement of detection sensitivity to {approx}50 ppm. Finally, a linear calibration curve was also obtained for the zircaloy-4 samples with zero intercept. These results demonstrate the feasibility of this technique for practical in situ and quantitative analysis of hydrogen impurity in zircaloy-4 tubes used in a light water nuclear power plant.

36 MATERIALS SCIENCE↗

DUST EXTINCTION AND METALLICITIES OF STAR-FORMING Ly{alpha} EMITTING GALAXIES AT LOW REDSHIFT

We present the results of an optical spectroscopic study of 12 GALEX-discovered star-forming Ly{alpha} emitting galaxies (LAEs) at z {approx} 0.3. We measure the emission-line fluxes from these galaxies by fitting their observed spectra to stellar population models in order to correct for underlying stellar absorption. We revisit earlier stellar population model fitting results, finding that excluding now-known active galactic nuclei lowers the typical stellar population age and stellar mass of this sample to {approx}300 Myr and {approx}4 x 10{sup 9} M{sub sun}, respectively. We calculate their dust extinction using the Balmer decrement, and find a typical visual attenuation of A{sub V} {approx} 0.3 mag, similar to that seen in some high-redshift LAEs. Comparing the ratios of Ly{alpha}/H{alpha} and the Ly{alpha} equivalent widths to the measured dust extinction, we find that the interstellar media (ISMs) in these objects appear to be neither enhancing nor seriously attenuating the Ly{alpha} equivalent widths, as would be the case in a quasi-clumpy ISM. Lastly, we perform a detailed analysis of the gas-phase metallicities of these galaxies, and we find that most galaxies in our sample have Z {approx}< 0.4 Z{sub sun}. We find that at a fixed stellar mass, these low-redshift LAE analogs are offset by {approx}0.3-0.6 dex lower metallicity from the general galaxy population at similar redshifts based on the local mass-metallicity relationship. This implies that galaxies with Ly{alpha} in emission may be systematically more metal-poor than star-forming galaxies at the same stellar mass and redshift, similar to preliminary results at z {approx} 2.

79 ASTRONOMY AND ASTROPHYSICS↗