Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Gamma-ray detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Sealed high-pressure x-ray detector

Detector is filled to pressure of 2 atm with mixture of 95% xenon and 5% methane for recording hard x-ray (50-to100-keV0 images with spatial resolution of about 1 mm. Being sealed, detector requires no gas purification or replenishment after initial fill. Potential areas of application include nuclear medicine, and x-ray or gamma-ray astronomy.

Gorenstein, P.↗

Search for an X-ray identification of a strong gamma-ray source

X-rays from Cygnus X-3 were observed during early 1978 with the detectors of the SAS-3 satellite. These observations in conjunction with earlier UHURU and ANS data indicate that the 4.8 hr period of Cygnus X-3 is increasing at the rate of P/P = (5/1 plus or minus 1.3) x 10 to the minus 6 power/1 yr. The sign and magnitude for this change are incompatible with a rotation model for the period and are in reasonable agreement with model predictions for orbital changes associated with mass loss and transfer in a binary system.

Lamb, R. C.↗

HEAO 1 observations of high-energy X-rays from 3C273

The first detection of high energy (13 to 120 keV) X rays from the quasar 3C273, made by the HEAO 1 satellite, is reported. Observations were made with the 13 to 180 keV slat collimated detectors of the high energy X-ray and low energy gamma-ray (A4) experiment during December 1977-January 1978 and June-July 1978. Results are consistent with the previously observed X-ray flux variability on a scale of months. Photon count rates are presented for each of five energy bands and count rate and photon spectra for the June through July 1978 observations are derived. A comparison of the data obtained with that at lower X-ray energies and higher gamma-ray energies indicates that there is an overall spectral steepening from low to high energies and a possible break near 20 keV, which may be due to the gamma rays originating from a different region than that of the X rays.

Primini, F. A.↗

Grand unification and possible matter-antimatter domain structure in the universe

The theory and basic concepts for the development of a matter-antimatter domain cosmology are outlined within the framework of the grand unified gauge theory paradigm. It is shown how spontaneous CP symmetry breaking leads to such a domain sturcture in the universe. Astrophysical data such as the cosmic gamma-ray background spectrum, cosmic-ray p flux measurements, and galaxy clustering are found to favor this point of view. Future tests of this form of big-bang cosmology are suggested and discussed, including tests using deep underwater cosmic ray neutrino detectors.

Stecker, F. W.↗

X-ray spectra of the Crab pulsar and Nebula

The X-ray spectra of the Crab pulsar and Crab Nebula are analyzed. Observations were made with OSO 8 on March 17-18, 1978, with all spacecraft telemetry assigned to one detector during seven dwell mode experiments. A resolution of 1.25 ms was obtained for pulse-height-analyzed counts in 64 channels. Progressive hardening and subsequent softening of the spectrum across the pulse was found. The fraction of the pulsed flux, exhibiting a spectral variability of about 0.14 was concentrated solely in the region between the two peaks. A model is suggested in which the pulsed X-ray emission from the Crab pulsar consists of two components: one is physically related to the double-peaked gamma-ray pulse and possibly to radio and optical pulses, but has no spectral dependence on the pulse phase, while the other exhibits spectral variability with the pulse phase but is confined to the interpeak emission seen with X-ray energies.

Pravdo, S. H.↗

A European X-ray astrophysics mission

Five instruments (Bragg Spectrometer, Large Area Proportional and Scintillation Counter Detectors, Wide Field X-ray Cameras and a Gamma-Ray Burst Monitor) are discussed and estimates of their performance are given. Their scientific aims are summarized and sample observing programmes are discussed.

Culhane, J. L.↗

Spectroscopy in the 10 keV to 10 MeV range

Spectral lines in the 10 keV to 1 MeV range carry information of fundamental importance on many astronomical objects. Since the lines are directly related to specific physical processes this information is model independent and gives the physical conditions in the objects. At the sensitivities achieved to date, approximately 0.0001 to 0.001 phsq cm. sec for steady sources and approximately 0.01 to 1 ph/sq cm sec for transient sources, lines were detected from the galactic center, gamma-ray bursts and transients, X-ray pulsators, the Crab pulsar and solar flares. Future instruments with a factor of approximately 100 sensitivity improvement will allow detailed spectroscopic study of these classes of objects as well as supernova remnants, active galaxies and the interstellar medium. This sensitivity improvement can be obtained through the use of detector technology already proven in balloon and satellite instruments.

Matteson, J. L.↗

Observations of interplanetary energetic charged particles from gamma-ray line solar flares

Results from ISEE-3 experiments on interplanetary energetic charged particles on June 7, June 21, and July 1, 1980 dealing with gamma ray producing solar flares are reported. The data were gathered by the Ultra Low Energy Wide Angle Telescope, which comprises a thin window, flow through proportional counter/solid-state detector composition telescope. Evidence of a specified time delay from an observed flare and the recording of 0.44-1.3 MeV electrons on ISEE-3 combined with quiescent periods of at least two hours before the observations and recording provides a link between the events. The data indicates interplanetary energetic particle enhancement, and a second, similar set of occurrences was also observed. Protons were accelerated up to 10-20 MeV. No enrichment of either He-3 or Fe was found.

Pesses, M. E.↗

The HEAO-3 high resolution gamma-ray spectrometer

Features and results produced by the HEAO 3 spacecraft gamma ray spectrometer are outlined. The instrument had high resolution germanium detectors, each 55 mm diam and 45 mm long, surrounded by a cesium iodide anticoincidence shield with four quadrants of well-crystal and a collimayor crystal. The crystals had a total effective area of 70 sq cm at 100 keV and 26.4 sq cm at .511 MeV with a spectral resolution at launch of .23 percent at 1.33 MeV. The spacecraft travels a circular orbit of 500 km altitude with an inclination of 43.6 deg. Solid methane and ammonia cryogenic fluids refrigerated the crystals for 8.5 mos, after which the shield crystals functioned as isotropic detectors for solar flare events and gamma ray bursts until mission termination in May 1981. A total of 37 solar flare type events were observed, with gamma ray events occurring with flares of class X1 or stronger.

Jacobson, A. S.↗

A study of the temporal and spectral characteristics of gamma ray bursts

Gamma-ray burst data obtained from the ISEE-3 Gamma Ray Burst Spectrometer and the Solar Maximum Mission's Hard X-ray Burst Spectrometer (HXRBS) were analyzed to yield information on burst temporal and spectral characteristics. A Monte Carlo approach was used to simulate the HXRBS response to candidate spectral models. At energies above about 100 keV, the spectra are well fit by exponential forms. At lower energies, 30 keV to 60 keV, depressions below the model continua are apparent in some bursts. The depressions are not instrumental or data-reduction artifacts. The event selection criterion of the ISEE-3 experiment is based on the time to accumulate a present number of photons rather than the photon count per unit time and is consequently independent of event duration for a given burst intensity, unlike most conventional systems. As a result, a significantly greater percentage of fast, narrow events have been detected. The ratio of count rates from two ISEE-3 detectors indicates that bursts with durations or approx. one second have much softer spectra than longer bursts.

Norris, J.↗

H0547-14 - X-ray flux from a weak gamma-ray burst?

Data concerning a fast X ray transient observed by the HEAO 1 on March 17, 1978 are discussed. The object, labeled H0547-14, was located in Lepus, with galactic coordinates 219.37 deg longitude, b = -20.12 deg in the anticenter direction. A 10 sec scan of the transient was obtained with proportional counter detectors. An X ray luminosity of more than 5.1 x 10 to the 31st ergs/sec was measured as a lower limit, with the decay taking 17 min. A lower limit to the flare was set at 30 sec. The flux intensity resided in the range 4.4/1 billion-4/100 million erg/sq cm per sec, with a rise time of a factor of 10 in about 5 sec. Possible characterizations of the object, as either a gamma ray burst or as an M dwarf star, are discussed.

Ambruster, C.↗

Observations of the galactic center with the GSFC low-energy gamma-ray spectrometer - Preliminary results

The results of measurements made of the gamma ray emission originating from the galactic center are reviewed. The data were gathered with balloon borne gamma ray spectrometers, with the scans centering on 511 keV. Minimum Chi-sq fits were calculated for the recorded emissions, assuming a constant source modulated by the detector response and superimposed on a constant background. A time history of the 511 keV line intensity demonstrated variability in the feature, whereas the continuum spectrum showed a high correlation with previous measurements. An excess in the continuum just below the 511 keV line was taken as an indication of positronium formation.

Paciesas, W. S.↗

High resolution X- and gamma-ray spectroscopy of cosmic X-ray sources

A high resolution X-ray spectrometer and large area phoswich detector were designed and co-aligned in a common elevation mounting in order to measure solar and cosmic X-ray and gamma ray emission in the 13 to 600 KeV energy range from a balloon. The instrument is described and results obtained for the Crab Nebula, the supernova remnant Cas A, and the Sun are discussed and analyzed.

Lin, R. P.↗

Three precise gamma-ray burst source locations

The precise source regions of three moderately intense gamma ray bursts are derived. These events were observed with the first interplanetary burst sensor network. The optimum locations of the detectors, widely separated throughout the inner solar system, allowed for high accuracy, over-determined source fields of size 0.7 to 7.0 arc-min(2). All three locations are at fairly high galactic latitude in regions of low source confusion; none can be identified with a steady source object. Archived photographs were searched for optical transients that are able to be associated with these source fields; one such association was made.

Cline, T. L.↗

A method to improve observations of gamma-ray sources near 10 (15) eV

Now that sources of gamma rays near 10 to the 15th power eV have been identified, there is a need for telescopes which can study in detail the high energy gamma ray emissions from these sources. The capabilities of a Cerenkov detector which can track a source at large zenith angle (small elevation angle) are analyzed. Because the observed showers must then develop far from the detector, the effective detection area is very large. During a single half-hour hot phase of Cygnus X-3, for example, it may be possible to detect 45 signal showers compared with 10 background showers. Time structure within the hot phase may then be discernible. The precise capabilities of the detector depend on its mirror size, angular acceptance, electronic speed, coincidence properties, etc. Calculations are presented for one feasible design using mirrors of an improved Fly's Eye type.

Sommers, P.↗

Photometric and spectroscopic gamma-ray observations of solar transient phenomena using long duration balloons

A program currently in progress to conduct extended duration spectroscopic and photometric observation of solar X-ray phenomena from balloons is described. High photometric sensitivity to weak hard X-ray bursts is attained using a 600 sq cm array of phoswich scintillators. High spectral resolution for stronger bursts is available from an array of planar germanium detectors. These instruments are carried in a novel balloon gondola dssigned for the 15 to 20 day float durations available through using conventional zero pressure balloons in the radiation controlled (RACOON) mode.

Pelling, M. R.↗

Nonthermal synchrotron radiation in a strong magnetic field

A synchrotron source model is presented for the origin of gamma-ray bursts from neutron stars. The field strength and length of time needed for electrons to lose sufficient energy in emitting the gamma rays are calculated, together with the efficiency of the process, limiting frequencies, and the energy output. A Monte Carlo simulation of the synchrotron radiation spectrum of an electron undergoing a self-consistent energy loss demonstrates that a process involving thermalized electrons can be sufficiently efficient to produce 30 keV gamma rays. Problems expected in using the current capabilities of detectors to scan for the projected energy spectra from fields of at least 3 x 10 to the 12th Gauss are discussed.

Bussard, R. W.↗

Spectral feature of 31 December 1981 gamma-ray burst not confirmed

Measurements of a gamma ray burst at 01:37 UT on December 31, 1981 using the SMM gamma ray spectrometer (GRS) are compared with those made by the Konus instruments on Veneras 11-14. Burst time profiles, photon spectra, and detector energy loss spectra for three time intervals are compared for the GRS and the Konus instruments. It is concluded that the SMM spectra exhibit no evidence for the presence of emission features reported by the Konus group.

Nolan, P. L.↗