Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Gamma ray experiments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Gamma Irradiation of NaCl-UCl 3 Salt for the Molten Chloride Fast Reactor

This report documents the results of the gamma ray irradiation of NaCl-UCl 3 eutectic salt in the Advanced Test Reactor (ATR) spent fuel pool gamma tube and subsequent analysis of capsules utilizing the Gas Assay Sample and Recharge (GASR) system. NaCl-UCl 3 salt capsules at four different temperatures, 75C, 150C, 300C and 600C, were irradiated shortly after the core internal changeout (CIC) of the ATR, beginning April 28 th of 2021, and ending on August 18 th of 2021. Re-positioning of the fuel elements in the spent fuel pool to move more fresh fuel elements around the gamma tube occurred on May 11 th of 2021, resulting in an approximate 20% increase in the dose rate and consequently the total absorbed dose. In total, the salt-filled capsules underwent 2638 hours of gamma irradiation from the adjacent freshly discharged ATR spent fuel. Capsule internal pressure measurements were taken via the Gas Assay Sample and Recharge (GASR) system in the INL Hot Fuels Examination Facility (HFEF) following completion of the irradiation. Based on the GASR analysis results, the primary conclusion from this experiment to-date is that radiolytic generation of chlorine gas is insignificant for the dose rates and total absorbed dose that these samples experienced. To elucidate more detailed effects of radiolysis on NaCl-UCl 3 eutectic salts and reach a more definitive conclusion, further advanced analyses such as electron microscopy, simultaneous thermal analysis, and electron paramagnetic resonance are recommended to analyze the capsule wall and salt samples.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Flow Measurements in Pressurized Helium Gas Cooling Channels

Production of metastable Technetium-99 (Tc-99m) is vital to the medical imaging community. It is a radioactive tracer that emits gamma rays as it decays and it is these gamma rays that are then detected through imaging. Tc-99m is extracted from the decay of Molybdenum-99 (Mo-99) which has a half-life of about 2-3 days. One method of generating Mo-99 is using accelerator based technology, through the irradiation of Mo-100 using an electron beam. This is part of the NNSA’s mission to produce Mo-99 commercially, within the US, without the use of highly enriched uranium (HEU) in support of nonproliferation and global security. Los Alamos National Laboratory (LANL) is working with NorthStar medical Radioisotopes (NMR) on their efforts to produce Mo-99 from the irradiation of Mo-100 targets. The NMR target consists of an Inconel window that allows the electron beam to penetrate and irradiate a stack of Mo-100 discs. The irradiation process generates large amounts of heat and requires extensive cooling of the Mo-100 targets and target housing using pressurized helium gas. Before beam on target, the design of the target stack and target housing is tested at LANL using laser based diagnostics experiments. We quantify the velocity field of the helium gas around the target housing to estimate whether the cooling provided is sufficient for the design and to validate computational fluid dynamics (CFD) models. Fiber optic imaging is also developed for use during cold testing (without beam on target) as well as during irradiation, to obtain real time information on disc performance.

07 ISOTOPE AND RADIATION SOURCES↗

$\gamma$-to-neutron branching ratio for deuterium-tritium fusion determined using high-energy-density plasmas and a fused silica Cherenkov detector

A fused silica Cherenkov detector was used to measure deuterium-tritium (DT) gammas during a set of 52 direct-drive cryogenic experiments performed at OMEGA. The detector was calibrated using the 4.4 MeV$\gamma$ from the first-excited state of carbon, which is produced when 14-MeV DT neutrons impinge upon a carbon puck. An approximate DT $\gamma$ spectrum as well as neutron yields from a standard neutron time-of-flight detector at OMEGA were used to calculate a DT $\gamma$-to-neutron branching ratio of (8.42 ± 2.84 ) x 10 -5 . Assuming an excited-state to ground-state ratio of 2.1:1, the measurement detailed in this work results in an approximate ground state only$\gamma$-to-neutron branching ratio of 2.72 x 10 -5 . So, this value is somewhat lower than accelerator-based measurements of the ground-state DT $\gamma$ only.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Developing the S 32 ( p , d ) S * 31 ( p ) ( γ ) reaction to probe the P 30 ( p , γ ) S 31 reaction rate in classical novae

Background: The 30 P(p,γ) 31 S reaction rate is one of the largest remaining sources of uncertainty in the final abundances of nuclei created in a classical nova involving a ONe white dwarf. The reaction rate directly influences silicon isotopic ratios, which are used as identifiers of presolar grains with nova origins. Additionally, the uncertainty in the 30 P(p,γ) 31 S reaction rate has been found to limit the use of nova nuclear thermometers based on observations of elemental ratios in nova ejecta. Purpose: Reduce uncertainties in the nuclear data for proton-unbound states in 31 S, which act as resonances for the 30 P(p,γ) 31 S reaction at classical nova temperatures, and develop a technique for high efficiency, high-resolution reaction-decay coincidence measurements. Methods: Here, the 32 S(p,d) 31 S reaction was used to populate the states of interest in 31 S. The experiment was performed at the Texas A&M Cyclotron Institute using the LLNL Hyperion array for the detection of charged particles and γ rays. A downstream silicon telescope was used to select reaction deuterons, and a single upstream silicon detector was used to measure protons emitted in the decay of unbound 31 S levels. Results: Several states in 31 S above the proton separation energy were observed to have been populated. Decay protons from the resonant states in 31 S were identified as events in the upstream silicon detectors that came in coincidence with deuterons in the downstream telescope. Protons emitted from these states were measured and branching ratios extracted. Conclusions: While no new reaction rate is derived, spin-parity assignments for several higher-lying proton unbound states have been confirmed. Measured p 0 branching ratios for these levels have been compared to previous measurements with good agreement, and in some cases provided a reduction in uncertainty. The previously identified T = 3/2 state may have been incorrectly assigned a large p 0 branching ratio in a previous measurement. The technique of measuring reaction-decay coincidences with a particle-gamma setup appears promising.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Integrating Experiments and Well Logs to Predict Caney Shale Static Mechanical Properties During Production with Supervised Machine Learning

Caney shale is one of the emerging oil reservoirs in Oklahoma. Understanding the impact of effective stress on its mechanical properties is critical for predicting hydraulic fracture geometry and overall hydrocarbon production. The objective of our study is to evaluate the impact of effective stress on the dynamic Young’s modulus using ultrasonic velocity measurements for Caney shale samples. A triaxial cell was utilized to measure ultrasonic (P-wave and S-wave) velocities for ten downhole Caney shale samples under various effective stresses to indirectly assess the impact of pore pressure change. The dynamic Young’s moduli estimated from these measurements were integrated with available conventional well logs (excluding sonic logs) and triaxial test results from Benge et al. (2021) to predict the static Young’s modulus using Random Forest (RF) and Extreme Gradient Boosting (XGBoost) models. The results showed that the estimated dynamic Young’s moduli from ultrasonic measurements were higher than the corresponding static Young’s modulus of cores from the same vertical well at similar depths. With increasing effective stress, the dynamic Young’s modulus increased for all samples. The estimated dynamic-to-static correction factor tended to be higher in zones of high neutron porosity (PHIN) and low density compared to other zones. Finally, SHapley Additive exPlanations (SHAP) for RF and XGBoost models identified depth, gamma ray (GR), and PHIN as key features for predicting the static Young’s modulus. This study enhances our understanding of the dynamic and static Young’s moduli for the Caney shale interval, as a function of effective stress and conventional well logs. The findings from this study can improve predictions of production throughout the well's lifespan by offering insights into the mechanical property degradation resulting from pore pressure depletion.

Kholy, Sherif M.↗

Development of Shielding Benchmarks Using the Godiva IV Assembly

The Nuclear Criticality Safety Program (NCSP) is developing a shielding benchmark using the Godiva IV assembly as a source. Its present status is reviewed herein. Even eight decades into the nuclear era, substantial work remains to develop a database of shielding benchmarks to support future nuclear development. A nuclear simulation is only as good as its supporting data, inputs, and validation basis. Uncertainty in these areas is addressed using conservatism, which adds margin and, occasionally, cost. In many shielding situations, high accuracy is not necessary because additional material is not particularly expensive. After all, 1–2 cm of lead often reduces the gamma ray dose substantially. However, in certain areas, conservatism can add unnecessary cost. These areas include mobile shielding applications such as casks, ships, microreactors, and spacecraft, where weight and, thus, margin is expensive. Although these characteristics are side benefits for NCSP shielding benchmark development, the main driver is enabling more reliable placement of criticality accident alarm systems (CAASs) in nuclear material facilities, such as those dedicated to the production of advanced reactor fuels. CAAS placement relies on more than accurate data and code validation. It also relies on sufficiently accurate materials specifications, geometry specifications, and a well-defined, alarm-producing baseline accident. All these things require tacit knowledge and understanding of the problem being evaluated. Benchmarks can help ensure this understanding.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Characterizing the Experiment for Calibration with Uranium (Excalibur) neutron source for use in warhead verification

Neutron sources can play a variety of roles in warhead verification. For transmission radiography, a source of directed high energy neutrons is required, while for applications to detect fissile isotopes, sub-MeV neutrons are preferred. The Excalibur (Experiment for Calibration with Uranium) neutron source has been built and used in a variety of verification-related experiments. Excalibur is based on a commercial deuterium-tritium neutron generator specified and measured to be capable of producing 14 MeV neutrons at rates of up to 8.2 × 10 8 neutrons/s. Here, the generator is enclosed in a carbon-steel 32" diameter, 23.62" high carbon-steel cylinder that moderates the mean neutron energy to under 500 keV. This, in turn, is encased in 5%-borated polyethylene such that the entire assembly is a 48" x 48" box that is 30" tall. For radiographic applications, a narrow, tapered channel in the steel and polyethylene allows 14 MeV neutrons to stream directly from the generator to a test object. Its collimating capability is demonstrated by measuring the neutron flux profile. In the moderated mode of operation, the generator is fully enclosed in the steel, but a large section of the polyethylene is removed, providing a flux of sub-MeV neutrons from a wide range of angles. Neutron angular and spectral measurements using both a nested neutron spectrometer and a commercial liquid scintillator coupled with a 3 He detector show the expected softer neutron spectrum in moderated mode in good agreement with MCNP6 calculations. The gamma-ray spectrum from Excalibur is also in good agreement with MCNP modeling. Based on these findings, the future application of Excalibur in its two configurations is discussed.

Fissile material detection↗

Extraction of neutron-capture cross sections on 92 Zr using the charge-exchange Oslo method

The 93 Nb (𝑡, 3 He ) reaction at 115 MeV/nucleon was studied to demonstrate that nuclear level densities and 𝛾-ray strength functions can be extracted from charge-exchange reactions at intermediate energies using the Oslo technique. The matrix of excitation energy in 93 Zr, reconstructed from the (𝑡, 3 He ) reaction, versus the energy of 𝛾 rays emitted by the excited 93 Zr nuclei, was obtained in an experiment with the S800 Spectrograph operated in coincidence with the GRETINA 𝛾 -ray detector. The extracted level density and 𝛾 -ray strength function obtained by applying the Oslo method to this matrix were used to estimate the 92 Zr⁢(𝑛,𝛾) ⁢93 Zr cross section by combining the new results with other experimental data and theoretical calculations for 𝐸⁢1 and 𝑀⁢1 strength functions at higher energies. Good agreement with direct measurements of the 92 Zr⁢(𝑛,𝛾)⁢ 93 Zr cross section was found. The contribution from the upbend in the extracted 𝛾-ray strength function was important to achieve the consistency, as the neutron-capture cross section without this contribution is significantly below the direct measurements otherwise. Since charge-exchange reactions at intermediate energies have long been used for extracting Gamow-Teller strengths, the successful demonstration of the charge-exchange Oslo method enables experiments in which (𝑛,𝛾) cross sections and Gamow-Teller strengths can be measured simultaneously, which is of benefit for astrophysical studies.

90 ≤ A ≤ 149↗

In situ monitoring of the stopped muon flux at Mu2e

The specific object of Mu2e search is the neutrino-less coherent $\mu^-\rightarrow e^-$ conversion in the field of an aluminum nucleus and the signal is a monoenergetic electron of energy $ \approx 104.97$ MeV. This process is forbidden in the Standard Model but allowed in many of its extensions: with minimal changes to include neutrino masses and oscillation, the Branching Ratio of this process, or the similarly interesting $\mu\rightarrow e \gamma$ decay, is expected to be of the order of $\mathcal{O}(10^{-54})$. Values like these are below any currently achievable experimental sensitivity, and the observation of a signal would be unambiguous evidence of New Physics. The upper limit on the muon conversion was set by SINDRUM II at $7\times10^{-13}$ (90\% C.L.) and the goal of the Mu2e collaboration is an improvement of 4 order of magnitudes.\\ The Mu2e experiment can be conceptually divided into three stages: interaction of the primary proton pulse with the tungsten target a nd production of $\pi$ and $\mu$; collection and transport of the produced particles down to the aluminum stopping target; interaction with the stopping target and measurement of the output particles. The measurement of the stopped muon flux is of cardinal importance for the normalization of the Mu2e results. The baseline design includes two detectors developed to measure this flux, counting $\gamma$ emitted by the muonic atoms: HPGe and LaBr$_3$(Ce). The studies performed by the Mu2e Collaboration show that these two systems can be reliably used to determine the overall normalization.\\ The number of stopped muons is proportional to the number of protons on target, which itself depends on the extraction system for the proton beam. The Mu2e beam delivery system will use a resonant extraction to create the proton pulses and this method is characterized by intensity fluctuations on the time scale of milliseconds. These fluctuations, aside from the proportional fluctuation of t he number of muons, have a non-trivial impact on the overall! performance of the apparatus. For example, higher intensity proton bunches translate into higher veto rates by the Cosmic Rays Veto system, which is triggered by secondary particles generated by the proton interaction. Another example is the effect of the instantaneous luminosity on the reconstruction efficiency: higher intensity translates into higher detector occupancy, which in turn reduces the reconstruction efficiency.\\ The two cited detectors encounter limitations when trying to monitor the flux at the millisecond timescales: HPGe is by construction a slow detector while the rate of emission of the $\gamma (1809\textrm{ keV})$ the LaBr$_3$(Ce) will measure is too low. As of today, no system allows to monitor these fluctuations and the goal of this Thesis is to try filling this gap. The method we developed to monitor the fluctuations of the stopped muon flux, and by extension, the fluctuation in the proton pulses intensity is based on counting the number of muons capt ured in the stopping target by counting the number of protons produced in the process of the nuclear muon capture. This is one of the possible processes a stopped muon can undergo and it can lead to the ejection of charged particles.\\ The reconstruction algorithms were developed by the Mu2e collaboration with the explicit (and sometimes implicit) aim to reconstruct tracks of electrons in an energy range of a conversion electron. The protons we are interested in behave quite differently from these electrons and the cardinal task of this study has been to tailor the reconstruction routines to these particles. This has been done by analyzing simulated events consisting of a single proton to optimize the procedure and understand the features of these tracks. A major difference with respect to the electrons is the non-relativistic nature of $100\div300$ MeV$/c$ protons: accounting for the low velocity is both a challenge and a unique signature of the tracks.\\ The use of a pulse d beam and the need to allow produced $\pi$ to decay and $\m! u$ to int! eract in the stopping target forces the definition of a Mu2e \textit{event}: an event is comprised by everything which happens in a $1.7\ \mu$s window between the incidence two consecutive proton pulses. This means that the reconstruction will be performed in an environment crowded by many different particles. The next step of this study has been to estimate the performance of the method in a fully-fledged Mu2e simulated event and to study what kind of selections would improve it.\\ Our results are satisfactory since the number of reconstructed protons is significant (few per event), and show that a monitor on the timescale of milliseconds is indeed possible.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Comparison and calibration of dose delivered by 137 Cs and x-ray irradiators in mice

Objective. The Office of Radiological Security, U.S. Department of Energy's National Nuclear Security Administration, is implementing a radiological risk reduction program which seeks to minimize or eliminate the use of high activity radiological sources, including 137 Cs, by replacing them with non-radioisotopic technologies, such as x-ray irradiators. The main goal of this paper is to evaluate the equivalence of the dose delivered by gamma- and x-ray irradiators in mice using experimental measurements and Monte Carlo simulations. We also propose a novel biophantom as an in situ dose calibration method. Approach. We irradiated mouse carcasses and 3D-printed mouse biophantoms in a 137 Cs irradiator (Mark I-68) and an x-ray irradiator (X-Rad320) at three voltages (160 kVp, 225 kVp and 320 kVp) and measured the delivered radiation dose. A Geant4-based Monte Carlo model was developed and validated to provide a comprehensive picture of gamma- and x-ray irradiation in mice. Main Results. Our Monte Carlo model predicts a uniform dose delivered in soft-tissue for all the explored irradiation programs and in agreement with the absolute dose measurements. Our Monte Carlo model shows an energy-dependent difference between dose in bone and in soft tissue that decreases as photon energy increases. Dose rate depends on irradiator and photon energy. We observed a deviation of the measured dose from the target value of up to –9% for the Mark I-68, and up to 35% for the X-Rad320. The dose measured in the 3D-printed phantoms are equivalent to that in the carcasses within 6% uncertainty. Significance. Our results suggest that 320 kVp irradiation is a good candidate to substitute 137 Cs irradiation barring a few caveats. There is a significant difference between measured and targeted doses for x-ray irradiation that suggests a strong need for in situ calibration, which can be achieved with 3D-printed mouse biophantoms. A dose correction is necessary for bone doses, which can be provided by a Monte Carlo calculation. Lastly, the biological implications of the differences in dose rates and dose per photon for the different irradiation methods should be carefully assessed for each small-animal irradiation experiment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Forward modeling approach to nuclear reaction cross sections: Applications in neutron inelastic scattering

The development of nuclear reaction models for the production of evaluated nuclear data has traditionally been performed by comparing measured cross sections with predictions from reaction model codes whose physical input parameters are adjusted to obtain the best agreement between measured and modeled results. To more directly probe reaction model inputs, this work introduces a forward modeling approach to experimental reaction cross-section determination, where the most important physical input parameters to reaction model calculations are obtained via 𝜒 2 minimization between measured and calculated observables. This was demonstrated using data collected by the Gamma Energy Neutron Energy Spectrometer for Inelastic Scattering (GENESIS) at the 88-inch cyclotron at Lawrence Berkeley National Laboratory, a detection array consisting of organic liquid scintillators and high-purity germanium (HPGe) detectors. Using a broad-spectrum neutron beam and a 99.98%-enriched 56 Fe target, GENESIS was used to perform a simultaneous measurement of 56 Fe 𝛾-ray production cross sections and secondary neutron energy and angle distributions. The results of the forward modeling approach to the determination of energy-differential 𝛾-ray production cross sections for the yrast 4 + → 2 + and 6 + → 4 + transitions, as well as eight other off-yrast transitions, were compared against those obtained using conventional techniques, and the results are in good agreement. In addition to discrete 𝛾-ray yield total scattered neutron energy-angular distributions as a function of incident neutron energy were also obtained using forward modeling and found to agree with evaluated data, with the exception of elastic scattering at small angles. The fitted reaction model parameters obtained through forward modeling were also used to calculate the cross section for the unobserved (𝑛, 2⁢𝑛) reaction; excellent agreement with the current evaluation was obtained, providing a validation of the predictive capabilities of the forward model approach. This work bridges the gap between nuclear data experiment and evaluation by providing a new means for extracting inelastic neutron-scattering cross sections and neutron-induced 𝛾-ray production data while directly probing reaction model physics.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of a compact fast-neutron spectrometer for nuclear emergency response applications

We have developed a Compact Fast Neutron Spectrometer (CFNS) for passive assay of special nuclear material (SNM) through the observation of fast neutrons. The CFNS consists of eight organic glass scintillators (OGS) coupled to silicon photomultipliers and a waveform digitizer, which are integrated within a human-portable box. The CFNS determines the neutron energy profile by spectrum unfolding using the Maximum-Likelihood Expectation Maximization method. The detector acquisition system was optimized to have a dynamic range of up to 10 MeV neutron energy. Bulk special nuclear material (SNM) measurements from the National Criticality Experiments Research Center were analyzed for SNM validation/examination. Additionally, the results show that the CFNS can be used to distinguish between fission and (α, n) neutron emitters, regardless of intervening material type (Cu and polyethylene) and thickness, by taking the ratio of neutron counts at different regions in the unfolded energy spectrum. Additionally, by fitting an exponential curve to the unfolded energy spectrum of PuO 2 and Pu neutron emitters, the CFNS showed the ability of distinguishing between pure Pu oxide, pure Pu metal and mixed oxide-metal configurations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The SRG/eROSITA All-Sky Survey: Dark Energy Survey year 3 weak gravitational lensing by eRASS1 selected galaxy clusters

Context. Number counts of galaxy clusters across redshift are a powerful cosmological probe if a precise and accurate reconstruction of the underlying mass distribution is performed – a challenge called mass calibration. With the advent of wide and deep photometric surveys, weak gravitational lensing (WL) by clusters has become the method of choice for this measurement. Aims. We measured and validated the WL signature in the shape of galaxies observed in the first three years of the Dark Energy Survey (DES Y3) caused by galaxy clusters and groups selected in the first all-sky survey performed by SRG (Spectrum Roentgen Gamma)/eROSITA (eRASS1). These data were then used to determine the scaling between the X-ray photon count rate of the clusters and their halo mass and redshift. Methods. We empirically determined the degree of cluster member contamination in our background source sample. The individual cluster shear profiles were then analyzed with a Bayesian population model that self-consistently accounts for the lens sample selection and contamination and includes marginalization over a host of instrumental and astrophysical systematics. To quantify the accuracy of the mass extraction of that model, we performed mass measurements on mock cluster catalogs with realistic synthetic shear profiles. This allowed us to establish that hydrodynamical modeling uncertainties at low lens redshifts (z < 0.6) are the dominant systematic limitation. At high lens redshift, the uncertainties of the sources’ photometric redshift calibration dominate. Results. With regard to the X-ray count rate to halo mass relation, we determined its amplitude, its mass trend, the redshift evolution of the mass trend, the deviation from self-similar redshift evolution, and the intrinsic scatter around this relation. Conclusions. The mass calibration analysis performed here sets the stage for a joint analysis with the number counts of eRASS1 clusters to constrain a host of cosmological parameters. We demonstrate that WL mass calibration of galaxy clusters can be performed successfully with source galaxies whose calibration was performed primarily for cosmic shear experiments, opening the way for the cluster cosmological exploitation of future optical and NIR surveys like Euclid and LSST.

79 ASTRONOMY AND ASTROPHYSICS↗

Synthesis and Single Crystals of Refractory Oxides of Lanthanides and Thorium

At the completion of this program, we can report that we developed a considerable degree of technical improvements in our ability to perform hydrothermal reactions at high temperatures and pressures. We can now routinely perform reactions at 700-750°C and 200 MPa. Currently we are in the process of exploiting this new technology synthesizing a range of exotic new materials investigating relatively poorly understood materials. Our initial efforts focused on the chemistry of rare earth oxides with tetravalent and pentavalent oxides. We recently published a study of the lanthanides with Nb 5+ and Ta 5+ ions, where we grew oxides such as RENdO 4 and RETaO 4 as high quality single crystals. These compounds were targeted as potential hosts for luminescent and scintillation materials, particularly given that they are among the densest oxide hosts and hence have good potential as absorbers for high energy radiation like X-rays and gamma rays. We also isolated a range of unusual new rare earth tantalates with very complex structures. indicating that the chemistry is very sensitive to conditions. We performed some fairly comprehensive examinations of the solid-state chemistry of rare earth ions with various tetravalent metal ions especially Si 4+ , Ge 4+ , Sn 4+ and Ti 4+ . Given the potential role of rare earth silicates in immobilizing radioactive waste elements in long-term storage, and the similarity of our hydrothermal fluids with known geological conditions, this chemistry continues to be relevant. We prepared an extensive series of new lanthanide germanates (e.g. RE 13 Ge 6 O 31 (OH), BaRE 10 (GeO 4 ) 4 O 8 ). and found that there is there is almost no overlap between the chemistry of the rare earth silicates. Stannic oxide (SnO 2 ) is much more refractory and requires higher temperatures and of mineralizer concentrations. One significant result is the growth of RE 2 Sn 2 O 7 pyrochlore single crystals. These are of interest because the rare earth stannate pyrochlores are known to display a wide range of magnetic frustration such as spin ice behavior. We grew high quality single crystals of rare earth germanate and stannate pyrochlores and this led to a collaboration with Professor Kate Ross at Colorado State. Preliminary measurements, indicate that the crystals contain no detectable defects or site disorder. Initial neutron diffraction on single crystals was performed at Oak Ridge, and more detailed experiments involving the Ross group are underway at both NIST and ORNL. This particular chemistry has turned out to be the most potentially significant work on this project and the collaborative effort with Prof. Ross is the topic of a DoE renewal project on quantum materials. Our initial foray into the hydrothermal chemistry of rare earth titanates has also been very promising and a range of cubic and polar ferroic phases of the light rare earths RE 2 Ti 2 O 7 (RE = La - Pr) in the P2 1 phase. We also discovered an interesting new phase Ce 2 Ti 4 O 11 that can have implications in heavy metal immobilization and storage. along with a series of new rare earth titanates (La 5 Ti 4 O 15 (OH) Sm 3 TiO 5 (OH) 3 and Lu 5 Ti 2 O 11 (OH) with exceptionally complex structures. One interesting sidelight has been high temperature hydrothermal chemistry terbium, including the growth of large crystals of TbO(OH). This is not a new compound but it is the first time it has been grown as large single crystals. The Tb atom density is almost as high as that in Tb 2 O 3 and has a very high Verdet constant (ca. 70), making it a very attractive candidate as a Faraday rotator. Unfortunately it is not in a cubic structure but he material is hard, stable, pure and inexpensive, so should still be an attractive Faraday oscillator. We recently received a patent on this material. We also synthesized K 2 Tb(Ge 2 O 7 ) containing stable octahedral Tb 4+ ions, which appears to be the first example of a well-characterized Tb 4+ complex. Given that Tb 4+ has been proposed as a benign surrogate for more treacherous tetravalent ions such as Cf 4+ and Bk 4+ , we think that Tb 4+ silicates can be a particularly useful study for actinide immobilization and related work. We also began reaction studies with rare earths and both ReO 2 and RuO 2 . These resulted in large single crystals of species like RE 5 Ru 2 O 12 , RE 4 Re 2 O 11 , REReO 4 and RE 2 ReO 5 . Several of these samples have already been sent to ORNL for magnetic and neutron diffraction studies.

36 MATERIALS SCIENCE↗

Westcott g factors extended to arbitrary neutron energy spectra

Westcott 𝑔 factors are used in Neutron Activation Analysis (NAA) and Prompt Gamma-ray Activation Analysis (PGAA) to evaluate the impact of non-1∕𝑣 behavior in the neutron-capture cross sections of certain nuclei on activation product yields. This non-1∕𝑣 behavior arises from the presence of neutron resonances in the neutron- capture cross sections that overlap with the source neutron spectrum at low (< 5 eV) energies. Historically, Westcott 𝑔 factors that have been cataloged for NAA and PGAA applications are the result of calculations that assume a Maxwellian neutron flux distribution with a given temperature. In this work, we use this approach with updated neutron-capture cross sections from the Evaluated Nuclear Data File, version VIII.1 (ENDF/B-VIII.1) to tabulate Westcott 𝑔 factor values for a broad range of Maxwellian distribution temperatures, comparing the results against currently-available 𝑔 factors from International Atomic Energy Agency tables and other sources. Here, it was discovered during this analysis that the use of guided thermal and cold-neutron beams at certain facilities necessitates an approach for evaluating Westcott 𝑔 factors based on arbitrary non-Maxwellian spectra. In this paper, we present an approach for calculating 𝑔 factors with user-specified neutron spectra, and we demonstrate these methods to obtain Westcott 𝑔-factors for guided- and cold-neutron beams at the Budapest Research Reactor and the Forschungsreaktor München II reactor. As part of this work, open-source software has been developed that can be used to perform these calculations for applications in PGAA and NAA experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Generation of radioisotopes for medical applications using high-repetition, high-intensity lasers

We used the PW high-repetition laser facility VEGA-3 at Centro de Láseres Pulsados in Salamanca, with the goal of studying the generation of radioisotopes using laser-driven proton beams. Various types of targets have been irradiated, including in particular several targets containing boron to generate α-particles through the hydrogen–boron fusion reaction. We have successfully identified γ-ray lines from several radioisotopes created by irradiation using laser-generated α-particles or protons including 43 Sc, 44 Sc, 48 Sc, 7 Be, 11 C and 18 F. We show that radioisotope generation can be used as a diagnostic tool to evaluate α-particle generation in laser-driven proton–boron fusion experiments. We also show the production of 11 C radioisotopes, ≈ 6 × 10 6 , and of 44 Sc radioisotopes, ≈ 5 × 10 4 per laser shot. This result can open the way to develop laser-driven radiation sources of radioisotopes for medical applications.

gamma ray spectroscopy↗

Gas scintillation mitigation in gas Cherenkov detectors for inertial confinement fusion (invited)

Gas Cherenkov detectors provide a time resolved measurement of the fusion burn in inertial confinement fusion experiments. The fusion rate delivers critical benchmark figures, such as burn width and bang time. Recent detector improvements pushed temporal resolution to 10 ps to make burn width measurements on igniting targets possible. First high temporal resolution measurements using CO 2 gas fills had a background signal with a long decay length (tail), which was caused by gas scintillation. This gas scintillation limits the ability of the detector to resolve short burn width and high frequency features in the fusion rate measurements. A thorough investigation of the cause of the tail and mitigation options for gas scintillation is presented here. As a near-term resolution, neon gas is being used to extract fusion burn histories. Paths forward for the next generation of gas Cherenkov detectors are identified including the usage of oxygen as a Cherenkov medium.

47 OTHER INSTRUMENTATION↗

Characterization of D-T Generator Neutron Flux Spectrum for Cyclic Neutron Activation Analysis Experiments

Improving nuclear data for short-lived fission product yields will further our fundamental understanding of fission, which is needed across various scientific fields and applications. One method of attaining the needed product yield data is through cyclic neutron activation, which allows a target to be irradiated in a neutron environment and then transported for counting of the radionuclides produced, typically via g spectroscopy. Recently, such a system has been constructed and commissioned at Pacific Northwest National Laboratory. Targets are shuttled between the head of a D-T neutron generator and a counting station with a transit time of 2 seconds. As part of the characterization of this system, the neutron flux was studied using two activation targets. The neutron flux from the deuterium-tritium fusion generator was determined to be 9.95(33) x10^8 n/cm2-s with a peak energy of 14.9 MeV and a spread of approximately 4 decades between the epithermal and 14 MeV peak group flux.

cyclic neutron activation, gamma-ray spectroscopy,↗