Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GUNS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Electron beam simulation from gun to collector: Towards a complete solution

An electron-beam simulation technique for high-resolution complete EBIS/T modelling is presented. The technique was benchmarked on the high compression HEC{sup 2} test-stand with an electron beam current, current density and energy of 10 A, 10 kA/cm{sup 2} and 49.2 keV, and on the immersed electron beam at REXEBIS for electron beam characteristics of 0.4 A, 200 A/cm{sup 2} and 4.5 keV. In both Brillouin-like and immersed beams the electron-beam radius varies from several millimeters at the gun, through some hundreds of micrometers in the ionization region to a few centimeters at the collector over a total length of several meters. We report on our approach for finding optimal meshing parameters, based on the local beam properties such as magnetic field-strength, electron energy and beam radius. This approach combined with dividing the problem domain into sub-domains, and subsequent splicing of the local solutions allowed us to simulate the beam propagation in EBISes from the gun to the collector using a conventional PC in about 24–36 h. Brillouin-like electron beams propagated through the complete EBIS were used to analyze the beam behavior within the collector region. We checked whether elastically reflected paraxial electrons from a Brillouin-like beam will escape from the collector region and add to the loss current. We have also studied the power deposition profiles as function of applied potentials using two electrode geometries for a Brillouin-like beam including the effects of backscattered electrons.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Note: O-ring stack system for electron gun alignment

We present a reliable method for aligning an electron gun which consists of an electron source and lenses by controlling a stack of rubber O-rings in a vacuum condition. The beam direction angle is precisely tilted along two axes by adjusting the height difference of a stack of O-rings. In addition, the source position is shifted in each of three orthogonal directions. We show that the tilting angle and linear shift along the x and y axes as obtained from ten stacked O-rings are ±2.55° and ±2 mm, respectively. This study can easily be adapted to charged particle gun alignment and adjustments of the flange position in a vacuum, ensuring that its results can be useful with regard to electrical insulation between flanges with slight modifications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An ultrafast nanotip electron gun triggered by grating-coupled surface plasmons

We demonstrate multiphoton photoelectron emission from gold nanotips induced by nanofocusing surface plasmons, resonantly excited on the tip shaft by a grating coupler. The tip is integrated into an electron gun assembly, which facilitates control over the spatial emission sites and allows us to disentangle direct grating emission from plasmon-triggered apex emission. The nanoscale source size of this electron gun concept enables highly coherent electron pulses with applications in ultrafast electron imaging and diffraction.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High voltage threshold for stable operation in a dc electron gun

We report clear observation of a high voltage (HV) threshold for stable operation in a dc electron gun. The HV hold-off time without any discharge is longer than many hours for operation below the threshold, while it is roughly 10 min above the threshold. The HV threshold corresponds to the minimum voltage where discharge ceases. The threshold increases with the number of discharges during HV conditioning of the gun. Above the threshold, the amount of gas desorption per discharge increases linearly with the voltage difference from the threshold. The present experimental observations can be explained by an avalanche discharge model based on the interplay between electron stimulated desorption (ESD) from the anode surface and subsequent secondary electron emission from the cathode by the impact of ionic components of the ESD molecules or atoms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High voltage breakdown phenomena in RF window, electron gun and RF cavities in 250 kW CW C band Klystron and their preventive measures

The paper describes voltage break down phenomenon and preventive measures in components of 250 KW CW, C band Klystron under development at CEERI Pilani. The Klystron operates at a beam voltage of 50 kV and delivers 250 kW RF power at 5 GHz frequency. The Klystron consists of several key components and regions, which are subject to high electrical stress. The most important regions of electrical breakdown are electron gun, the RF ceramic window and output cavity gap area. In the critical components voltage breakdown considered at design stage by proper gap and other techniques. All these problems discussed, as well as solution to alleviate this problem. The electron gun consists basically of cathode, BFE and anode. The cathode is operated at a voltage of 50 kV. In order to maintain the voltage standoff between cathode and anode a high voltage alumina seal and RF window have been designed developed and successfully used in the tube. (author)

43 PARTICLE ACCELERATORS↗

Design of indirectly heated thoriated tungsten cathode based strip electron gun

Design of indirectly heated solid cathode based electron gun (200 kW, 45 kV, 270 degree bent strip type electron gun) has been presented. The solid cathode is made of thoriated tungsten. The solid cathode design has been suitably done to achieve required electron beam cross section. The design approach consists of simulation followed by extensive experimentation. In the design, the effort has been put to reduce the non-uniformity of the heat flux from the filament to the solid cathode to obtain better uniformity of temperature on the solid cathode. Trial beam experiments shows that the modified design achieves one to one correspondence of the solid cathode length and the electron beam length. (author)

43 PARTICLE ACCELERATORS↗

Dynamics of pulsed magnetron discharge in high-current electron guns

High-speed video filming is applied to investigate low-pressure (argon 0.053–0.133 Pa) pulsed gas discharge dynamics in a planar magnetron built-in the explosive emission cathode of a high-current electron gun. It has been found that, in the beginning, the discharge starts at the side surface of the cathode and then spreads to its face. The stability of the discharge ignition instant at the cathode face as a function of the working pressure of the gas and the cathode design has been studied. It has been found that the pulsed longitudinal magnetic field results in the discharge switching over in the axial direction onto the electron gun collector. A qualitative explanation of the observed discharge behavior has been given.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

STREAK CAMERA MEASUREMENTS OF THE APS PC GUN DRIVE LASER

We report recent pulse-duration measurements of the APS PC Gun drive laser at both second harmonic and fourth harmonic wavelengths. The drive laser is a Nd:Glass-based chirped pulsed amplifier (CPA) operating at an IR wavelength of 1053 nm, twice frequency-doubled to obtain UV output for the gun. A Hamamatsu C5680 streak camera and an M5675 synchroscan unit are used for these measurements; the synchroscan unit is tuned to 119 MHz, the 24th subharmonic of the linac s-band operating frequency. Calibration is accomplished both electronically and optically. Electronic calibration utilizes a programmable delay line in the 119 MHz rf path. The optical delay uses an etalon with known spacing between reflecting surfaces and is coated for the visible, SH wavelength. IR pulse duration is monitored with an autocorrelator. Fitting the streak camera image projected profiles with Gaussians, UV rms pulse durations are found to vary from 2.1 ps to 3.5 ps as the IR varies from 2.2 ps to 5.2 ps.

LASER↗

Phase II Final Report Computer Optimization of Electron Guns

This program implemented advanced computer optimization into an adaptive mesh, finite element, 3D, charged particle code. The routines can optimize electron gun performance to achieve a specified current, beam size, and perveance. It can also minimize beam ripple and electric field gradients. The magnetics optimization capability allows design of coil geometries and magnetic material configurations to achieve a specified axial magnetic field profile. The optimization control program, built into the charged particle code Beam Optics Analyzer (BOA) utilizes a 3D solid modeling package to modify geometry using design tables. Parameters within the graphical user interface (currents, voltages, etc.) can be directly modified within BOA. The program implemented advanced post processing capability for the optimization routines as well as the user. A Graphical User Interface allows the user to set up goal functions, select variables, establish ranges of variation, and define performance criteria. The optimization capability allowed development of a doubly convergent multiple beam gun that could not be designed using previous techniques.

43 PARTICLE ACCELERATORS↗

Evaluation of the LLNL Spectrometer for Possible use with the NSTec Optical Streak Camera as a Light Gas Gun Diagnostic

In fiscal year 2012, it was desired to combine a visible spectrometer with a streak camera to form a diagnostic system for recording time-resolved spectra generated in light gas gun experiments. Acquiring a new spectrometer was an option, but it was possible to borrow an existing unit for a period of months, which would be sufficient to evaluate both “off-line” and in-gas gun shots. If it proved adequate for this application, it could be duplicated (with possible modifications); if not, such testing would help determine needed specifications for another model.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Construction and Test of a Novel Superconducting RF Electron gun

The University of Wisconsin-Madison has completed installation of a superconducting electron gun. Its concept was optimized to be the source for a CW free electron laser facility with multiple megahertz repetition rate end stations. This VHF superconducting configuration holds the promise of the highest performance for CW injectors. Initial commissioning efforts show that the cavity can achieve gradients of 35 MV/m at the cathode position. With the cathode inserted CW operation has been achieved at 20 MV/m with good control of microphonics, negligible dark current, and Q 0 > 3×10 9 at 4 K. Bunch charges of ~100 pC have been delivered, and first simple beam measurements made. These preliminary results are very encouraging for production of 100s pC bunches with millimeter-milliradian or smaller normalized emittances. Plans are in place to carry out more definitive studies to establish the full capabilities. However, since the grant was not renewed, the electron gun is currently mothballed, and without supplemental fund the opportunity for further work will be lost.

43 PARTICLE ACCELERATORS↗

Cylinder expansion test and gas gun experiment comparison

This is a summer internship presentation by the Hydro Working Group at Los Alamos National Laboratory (LANL) and goes into detail about their cylinder expansion test and gas gun experiment comparison. Specifically, the gas gun experiment is detailed along with applications, the cylinder expansion test is detailed along with applications, there is a comparison of the methods with pros and cons and limitations listed, the summer project is detailed, and future work is talked about.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Parallel 3D Finite Element Numerical Modelling of DC Electron Guns

In this paper we present Gun3P, a parallel 3D finite element application that the Advanced Computations Department at the Stanford Linear Accelerator Center is developing for the analysis of beam formation in DC guns and beam transport in klystrons. Gun3P is targeted specially to complex geometries that cannot be described by 2D models and cannot be easily handled by finite difference discretizations. Its parallel capability allows simulations with more accuracy and less processing time than packages currently available. We present simulation results for the L-band Sheet Beam Klystron DC gun, in which case Gun3P is able to reduce simulation time from days to some hours.

43 PARTICLE ACCELERATORS↗

5 TeV pgun collisions, Single particles type, PARTICLE GUN generator: pgun_pi_single

Single particle gun for detector studies: A particle gun with single pions. One pion per event. Production at (x,y,z,t)=(0,0,0,0). Pi+ and Pi- are alternated. Momentum of pions is 0.5, 5, 50, 500 , 5000 GeV (alternated). Uniform distribution in Phi. Uniform distribution in in the range [-4.5, 4.5].

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

5 TeV pgun collisions, Single particles type, PARTICLE GUN generator: pgun_pi_single_mu40

Single particle gun for detector studies: A particle gun with single pions. One pion per event. Production at (x,y,z,t)=(0,0,0,0). Pi+ and Pi- are alternated. Momentum of pions is 0.5, 5, 50, 500, 5000 GeV (alternated). Particles are generated using a uniform distribution in Phi and uniform distribution in Eta (pseudorapidity) in the range [-4.5,4.5]. Mixing with pileup: Each event is mixed with pileup using the tool described in arXiv:1510.06638. The pileup events use ATLAS A2 tune (all inelastic, including single and double diffractive events). The CM energy was 14 TeV. Events were generated with PYTHIA8. Events are mixed using a Poisson distribution with the mean mu=40 (average number of MinBias events). Then, only pileup particles around the single pion where taken in the cone 0.1 defined in eta and phi.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗