Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GROUT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Evaluation Of Saltstone Mixer Paddle Configuration For Improved Wear Resistance

A soft metal with low wear resistance (6000 series aluminum), was used to minimize run time while maximizing wear rate. Two paddle configurations were tested, with the first four paddles after the augers replaced by the wear paddles. The first configuration was all flat paddles, with the first paddle not aligned with the augers and is consistent with present SPF mixer. The second configuration had helical paddles for the first three stages after the augers and a flat paddle at the fourth stage. The first helical paddle was aligned with the auger flight for the second configuration. The all flat paddle configuration wear rate was approximately double the wear rate of the helical paddles for the first two sets of paddles after the augers. For both configurations, there was little or no wear on the third and fourth paddle sets based on mass change, indicating that the fully wetted premix materials are much less abrasive than the un-wetted or partially wetted premix. Additionally, inspection of the wear surface of the paddles at higher magnification showed the flat paddles were worn much more than the helical and is consistent with the wear rates. Aligning the auger discharge flight with the first set of helical paddles was effective in reducing the wear rate as compared to the flat paddle configuration. Changing the paddle configuration from flat to helical resulted in a slight increase in rheological properties. Although, both tests produced grout-like material that is within the processing rage of the SPF, it should be noted that cement is not included in the premix and water was used rather than salt solution, which does affect the rheology of the fresh grout. The higher rheological properties from the helical wear test are most likely due to the reduced number of shearing paddles in the mixer. In addition, there is variation in the rheological data for each wear test. This is most likely due to the way that the dry feeds enter the mixer from the dry feeder. The premix is discharged from the hopper in an unsteady fashion, where irregular sized clumps were observed leaving the discharge of the auger, though the auger speed is constant.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effect of Transporting Saltstone Samples Prior to Set

The Saltstone Sampling and Analyses Plan provides a basis for the quantity (and configuration) of saltstone grout samples required for conducting a study directed towards correlation of the Performance Assessment (PA) related properties of field-emplaced samples and samples processed and cured in the laboratory. The testing described in the saltstone sampling and analyses plan will be addressed in phases. The initial testing (Phase I) includes collecting samples from the process room in the Saltstone Production Facility (SPF) and transporting them to Savannah River National Laboratory (SRNL) where they will cure under a temperature profile that mimics the temperature in the Saltstone Disposal Unit (SDU) and then be analyzed. SRNL has previously recommended that after the samples of fresh (uncured) saltstone are obtained from the SPF process room, they are allowed to set prior to transporting them to SRNL for curing. The concern was that if the samples are transported before they are set, the vibrations during transport may cause artificial delay of structure development which could result in preferential settling or segregation of the saltstone slurry. However, the results of this testing showed there was no clear distinction between the densities of the cylinder sections for any of the transportation scenarios tested (1 day, 1 hour, and 0 minutes set time prefer to transportation) . The bottom section of each cylinder was the densest for each transportation scenario, which indicates some settling in all the samples. Triplicate hydraulic conductivity measurements on samples from each set of time and transportation scenarios indicated that those samples transported immediately after pouring had the highest hydraulic conductivity. Conversely, samples that were allowed to sit for an hour before being transported had the lowest hydraulic conductivity. However, the hydraulic conductivities of all three samples fell within an acceptable range. Based on the cured property analysis of the three samples, there is no clear conclusion about transporting the samples before they are set; however, experience with saltstone grout indicates the samples should sit and develop some structure before being transported to SRNL for curing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Secondary Waste Simulant Development for Cast Stone Formulation Testing

Washington River Protection Solutions, LLC (WRPS) funded Pacific Northwest National Laboratory (PNNL) to conduct a waste form testing program to implement aspects of the Secondary Liquid Waste Treatment Cast Stone Technology Development Plan (Ashley 2012) and the Hanford Site Secondary Waste Roadmap (PNNL 2009) related to the development and qualification of Cast Stone as a potential waste form for the solidification of aqueous wastes from the Hanford Site after the aqueous wastes are treated at the Effluent Treatment Facility (ETF). The current baseline is that the resultant Cast Stone (or grout) solid waste forms would be disposed at the Integrated Disposal Facility (IDF). Data and results of this testing program will be used in the upcoming performance assessment of the IDF and in the design and operation of a solidification treatment unit planned to be added to the ETF. The purpose of the work described in this report is to 1) develop simulants for the waste streams that are currently being fed and future WTP secondary waste streams also to be fed into the ETF and 2) prepare simulants to use for preparation of grout or Cast Stone solid waste forms for testing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ammonia Remediation in Hanford WTP Liquid Secondary Waste

The Hanford Site Effluent Treatment Facility (ETF) treats aqueous waste streams; some of these waste streams have high concentrations of ammonium ion. When the WTP begins operation the ETF LSW is slated to be stabilized by grouting prior to disposal. During stabilization of such waste by grouting the pH would rise considerably, leading to the evolution of ammonia gas. Such an ammonia release would require engineering controls to assure worker and environmental safety. The primary objective of this work was to perform a parametric study of the efficacy of ammonia destruction from solution using sodium nitrite addition under varying conditions that expands upon previous work.

54 ENVIRONMENTAL SCIENCES↗

235-F Deactivation and Decommissioning: Inventory and Scenarios

Facility inventory has a significant influence on the fate and transport modeling of 235-F. This memorandum details the proposed source inventory for 235-F for verification from 235-F Risk Reduction (see Tables 7 and 9) and specifies two scenarios that will be investigated using GoldSim and PORFLOW as follows: grout the entire first floor (including the area directly below PuFF cells), and grout the entire first and second floors (including the area directly below PuFF cells).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Performance Metric for Cementitious Waste Form Inventory Release in the Integrated Disposal Facility

This report describes work supporting Phase 1 of the 2018 Department of Energy (DOE) Office of River Protection’s (ORP) Grand Challenge recipient proposal “Cementitious Immobilization of Treated LAW and Ancillary Benefits to Risk Reduction in Cross Site Transfer”. Phase 1 was to establish a performance metric for grout leachability against which laboratory leach data (as observed diffusivities) can be assed, followed by a comparison of historical test data against this metric. Historically, advancements in the cementitious (grout) waste form performance have been made over the last 40 years, with the majority of progress achieved within the past 8 years as part of the Washington River Protection Solutions, LLC testing program. This report presents a summary of that effort relevant to the Hanford Site.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Using Radioiodine Speciation to Address Environmental Remediation and Waste Stream Sequestration Problems at the Fukushima Daiichi Nuclear Power Plant and a DOE Site

Iodine-129 ( 129 I), with a half-life of half-life of 16 million years, is commonly considered the single greatest risk driver in high-level and low-level nuclear repositories. This risk stems from several basic properties of 129 I, and under many geochemical conditions, it can move as an anion at nearly the rate of water through the subsurface environment. 129 I is also extremely radiologically toxic because over 90% of body burden accumulates in the thyroid, which weighs only about 14g in an adult. There is also a large worldwide inventory of radioiodine as a result of its high fission yield and this inventory is rapidly increasing as a result of nuclear energy production. Radioiodine is produced at a rate of 40 GBq (1 Ci) per gigawatt of electricity produced by nuclear power. To illustrate how the properties of 129 I magnify its risk, 129 I accounts for only 0.00002% of the radiation released from the Savannah River Site in Aiken, South Carolina, but contributes 13% of the population dose, a six orders of magnitude magnification of risk with respect to its radioactivity. The currently favored solid phase for LLW immobilization is cement, while HLW immobilization is the incorporation of waste into glass (vitrification). However, so far, the incorporation into cement and subsequent leaching of only iodide has been seriously investigated. The major problem with this approach is that it ignores the complex speciation of iodine, i.e., it ignores iodate and organo-iodine which have different chemistries. Most of the past research was devoted to the mechanism of iodide uptake in cement hydrate phases that is sorption and/or incorporation. Very few data exist on iodate and organo-iodine incorporation in cement, even though large quantities of liquid waste containing also radioiodine have already been solidified in cement Iodine-129 from low-level waste is commonly disposed of in cementitious materials. Grout, a dense cementitious fluid, mixed with a reducing slag, is often used to immobilize radionuclides. However, the reducing environment might not be conducive to immobilize iodine. For example, the silver based immobilization technologies (e.g., AgCl, Ag-impregnated granular activated carbon, Ag-mordenite) remove iodine from the aqueous phase by promoting the formation of Ag-iodide precipitates. The solubility of AgI is eight orders of magnitude lower than it is for AgIO 3 . Similarly, coprecipitation of iodine into calcium carbonate phases occurs only with IO 3 - and not with I - and org-I. If one would want to immobilize iodine more effectively, different engineering approaches would need to be used to promote binding of I - , IO 3 - , or organo-I. Using laboratory experiments with grout, slag, and silver-based adsorbents, and GC-MS and I K-edge XANES and EXAFS and C K-edge XANES spectroscopy for identifying iodine speciation, the major problems with these methods have been identified as focused too much on just one of the iodine species for immobilization, while others, especially organo-I, remained mobile. Finally, we established that most of the adsorbents that are used contain sufficient amounts of organic matter to create organo-I . It is anticipated that increased attention directed at understanding and quantifying the speciation of radioiodine, as opposed to simply total radioiodine, will lead to improved remediation results to be used for long-term radioiodine disposal in cementitious waste forms.

129-Iodine↗

Solidification of REDC Organics and Airborne Release Fraction Measurements

The Radiochemical Engineering Development Center (REDC) generates various liquid organic wastes from processing irradiated targets to recover heavy elements. In the past, these organics were discharged to the Oak Ridge National Laboratory (ORNL) liquid low-level waste (LLLW) system, along with the aqueous waste. Because of a reduction in aqueous LLLW from other ORNL generators and an increase in the radionuclide concentration, particularly 238 Pu, in the organic waste stream, the organics can no longer be discharged to the LLLW system. The plan is to solidify the liquid organic waste for disposal as solid debris waste. The documented safety analysis for REDC uses an airborne release fraction of 5 x 10 -4 with a respirable fraction of 0.2 for plutonium and other actinides from packaged solid debris waste during a fire scenario, for an overall airborne release fraction/respirable fraction of 10 -4 . Solidifying the organic liquids, either by using PM-199 Organoclay ® or by grouting, would produce solid waste forms with no free liquid, which should qualify for disposal at the Waste Isolation Pilot Plant. The use of Organoclay would be much simpler to implement inside a hot cell. Granular Organoclay can be added to the organic waste solutions until there is a dry layer on top of the liquid and then allowed to cure for a few hours. Grouting the liquids would require using multiple ingredients and mixing steps. Both methods produced waste forms that trapped cerium, as a surrogate for plutonium, inside the waste, with airborne release fractions during fire scenario tests of well below the 10 -4 limit.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Blast furnace slag reactions in various solutions (Interim Report)

Blast furnace slag (BPS) is a critical component of grout formulations for the remediation of low activity nuclear waste. This interim report describes the initial results of a study designed to investigate the fundamental mechanisms of BPS dissolution. The goal of the work is to delineate the physicochemical aspects of the slag that impart beneficial properties to grout formulations to enable the consistent production of a slag-replacement material (“designer slag”) that performs better than what is commercially available. This report documents the dissolution experiments that were conducted using nine different initial solution compositions. Solution measurements for each solution, including pH and solution composition, are given for 1, 7, 14, 28, and 56 day intervals samples. Scanning electron microscopy images are presented for the 56 day samples from each of the solutions. Inferences about reaction mechanisms and 56-day mineralogy are made based on the information collected to date. Some conclusions are made based on the work performed for this interim report, and a path forward including the strategy for making stronger conclusions based on X-ray diffraction (XRD) analyses is presented.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Field Results from New Tensor Borehole Optical Fiber Strainmeter Installations in Oklahoma and Utah

The time evolving strain field contains a wealth of information that can be used to interpret subsurface behavior. For example, injecting or removing fluids from reservoirs or aquifers causes deformation that can be used as a diagnostic signal in some cases, while it can interfere with geodetic interpretations in other cases. We've previously demonstrated the feasibility of measuring the strain tensor at a depth of 30m caused by injection into a reservoir at 530m. The observed strain signals were interpreted using four independent analytic and numerical methods that resulted in estimates of the poroelastic properties and geometry of the reservoir that was consistent with data from well logs. However, studies like these are only possible if these deformations can be reliably measured. Years of lab and field work has culminated in the development of a novel borehole strainmeter capable of resolving multiple components of strain using embedded optical fibers configured as Michelson interferometers. It features four horizontal gauges separated by 45° to resolve the horizontal strain tensor as well as a vertical strain gauge and a sixth null component for state-of-health monitoring. The downhole sensing package also includes an open pipe through its center for grout circulation during single-trip deployments and a fully welded stainless steel exterior for robustness and longevity. These instruments have a resolution of 2x10-13 strain that can easily measure the solid earth tides. Preliminary data are available from four strainmeters in shale at our Oklahoma site and four in compacted sand and gravel in Utah. These are deployed from 40-60m, except one of the strainmeters in Oklahoma is deployed at 500m. The data include strains from the initial grout curing, comparisons to predicted earth tide models and in-situ calibration results, barometric pressure admittances and spectral analyses as well as signals from underground injections and surface waves from teleseismic events. Preliminary analyses indicate behavior consistent with other strainmeter deployments, and comparison to data from a Gladwin strainmeter at the Oklahoma site validate the performance of the new design. Analyses from a suite of six well tests at the Oklahoma site show for the first time how the strain tensor field varies with location during well testing.

DeWolf, Scott↗

Measuring and interpreting borehole strainmeter data to improve CO2 storage

Injecting fluids into a well deforms the enveloping rocks in a complex pattern that increases in magnitude and expands outward with time, and measurements of this strain field may be useful for monitoring the injection process. A pair of instruments capable of measuring four components of strain and two components of tilt has been developed. One instrument is designed to be removeable, whereas the other one is grouted in place. The removeable strainmeter provides versatility and lower cost because it can be relocated, whereas the grout-in instrument provides better coupling to the formation, which should improve the strain signal. The new strainmeters have been deployed along with a Gladwin strainmeter at the Avant Field, an oil field north of Tulsa, Oklahoma. Oil and water are being pumped out, and water is being injected in multiple boreholes that intersect the Bartlesville formation at a depth of approximately 500 m at the Avant Field. The strainmeters have been deployed at a depth of 30 m near well 9A, an injection well near the edge of the field. Results from a brief, 4-hr-long injection test into well 9A show that the radial and circumferential strain increase (become tensile) with time during injection, reaching a maximum of several 10s of nanostrain. In another example, data from the Gladwin strainmeter showed the strain field changing with time when an injection well 1 km away was shut-in. This caused the strain along a radial direction to become tensile, while the circumferential strain became compressive. This trend reversed a week later when injection into the well resumed. The major axis of the principle strain aligned with the shut-in well. The observed strain signals are similar to results from poroelastic analyses, and preliminary inverse analyses sugest that strain signals can be used to estimate reservoir characteristics at the Avant Field.

Murdoch, Larry↗

Development of Magnesium Oxysulfate Formulation for SRPPF Aqueous Recovery Liquid Solidification

The liquid effluent from the Savannah River Plutonium Processing Facility (SRPPF) Aqueous Recovery Processes will be solidified into a stable form that is acceptable by Waste Isolation Pilot Plant (WIPP) for disposal. The current Aqueous Recovery flow sheet proposes to solidify the liquid effluent using a grout formula that was developed and tested for the former Waste Solidification Building process. This Portland cement based mixture results in a high pH (~13) leachate from the solidified waste form which is not acceptable to WIPP in the large quantities expected from production at SRPPF. Various cementitious materials were previously evaluated as alternative grout formulations to Portland cement and a MgO-based mix was identified as a promising alternative. A magnesium oxysulfate (MOS) cement formulation comprised of reactive magnesium oxide (MgO), anhydrous magnesium sulfate (MgSO 4 ), and sand, as a non-reactive heat sink provided good mixability, similar density to the original Portland-cement based mix, and a leachate pH of 9.4, within the assumed WIPP brine pH range. However, the MOS formulation exhibited an appreciable amount of heat generation, which resulted in premature setting of a large-scale test.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Control Selection for the Neutralization Tank in the Aqueous Recovery System at SRPPF

• Neutralization and solidification is the last step in the Aqueous Recovery Process • All waste streams are acidic and must be neutralized before being combined with grout in a solidification drum • The neutralization tank is a 250 L, 24” diameter, 45” high tank • The batch tank is a 125 L tank • The solidification drum is a 55-gallon drum, pre-filled with grout & a sacrificial mixing paddle • Normal mass in neutralization tank: 50 g Pu • Normal mass in batch tank or drum: 25 g Pu

Dressman, Phillip M. [Savannah River Nuclear Solut↗

Closure Report for Corrective Action Unit 166: Storage Yards and Contaminated Materials, Nevada Test Site, Nevada

Corrective Action Unit (CAU) 166 is identified in the Federal Facility Agreement and Consent Order (FFACO) as 'Storage Yards and Contaminated Materials' and consists of the following seven Corrective Action Sites (CASs), located in Areas 2, 3, 5, and 18 of the Nevada Test Site: CAS 02-42-01, Condo Release Storage Yd - North; CAS 02-42-02, Condo Release Storage Yd - South; CAS 02-99-10, D-38 Storage Area; CAS 03-42-01, Conditional Release Storage Yard; CAS 05-19-02, Contaminated Soil and Drum; CAS 18-01-01, Aboveground Storage Tank; and CAS 18-99-03, Wax Piles/Oil Stain. Closure activities were conducted from March to July 2009 according to the FF ACO (1996, as amended February 2008) and the Corrective Action Plan for CAU 166 (U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office, 2007b). The corrective action alternatives included No Further Action and Clean Closure. Closure activities are summarized. CAU 166, Storage Yards and Contaminated Materials, consists of seven CASs in Areas 2, 3, 5, and 18 of the NTS. The closure alternatives included No Further Action and Clean Closure. This CR provides a summary of completed closure activities, documentation of waste disposal, and confirmation that remediation goals were met. The following site closure activities were performed at CAU 166 as documented in this CR: (1) At CAS 02-99-10, D-38 Storage Area, approximately 40 gal of lead shot were removed and are currently pending treatment and disposal as MW, and approximately 50 small pieces of DU were removed and disposed as LLW. (2) At CAS 03-42-01, Conditional Release Storage Yard, approximately 7.5 yd{sup 3} of soil impacted with lead and Am-241 were removed and disposed as LLW. As a BMP, approximately 22 ft{sup 3} of asbestos tile were removed from a portable building and disposed as ALLW, approximately 55 gal of oil were drained from accumulators and are currently pending disposal as HW, the portable building was removed and disposed as LLW, and accumulators, gas cylinders, and associated debris were removed and are currently pending treatment and disposal as MW. (3) At CAS 05-19-02, Contaminated Soil and Drum, as a BMP, an empty drum was removed and disposed as sanitary waste. (4) At CAS 18-01-01, Aboveground Storage Tank, approximately 165 gal of lead-impacted liquid were removed and are currently pending disposal as HW, and approximately 10 gal of lead shot and 6 yd{sup 3} of wax embedded with lead shot were removed and are currently pending treatment and disposal as MW. As a BMP, approximately 0.5 yd{sup 3} of wax were removed and disposed as hydrocarbon waste, approximately 55 gal of liquid were removed and disposed as sanitary waste, and two metal containers were grouted in place. (5) At CAS 18-99-03, Wax Piles/Oil Stain, no further action was required; however, as a BMP, approximately l.5 yd{sup 3} of wax were removed and disposed as hydrocarbon waste, and one metal container was grouted in place.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The EGS Collab Project – Stimulations at Two Depths

The EGS Collab project, supported by the US Department of Energy, is performing intensively monitored rock stimulation and flow tests at the 10-m scale in an underground research laboratory to address challenges in implementing enhanced geothermal systems (EGS). Data and observations from the field tests are compared to simulations to understand processes and build confidence in numerical modeling of the processes. We have completed Experiment 1 (of 3), which examined hydraulic fracturing in a well-characterized underground fractured phyllite test bed at a depth of approximately 1.5 km at the Sanford Underground Research Facility (SURF) in Lead, South Dakota. Testbed characterization included fracture mapping, borehole acoustic and optical televiewers, full waveform sonic, conductivity, resistivity, temperature, campaign p- and s-wave investigations and electrical resistance tomography. Borehole geophysical techniques including passive seismic, continuous active source seismic monitoring, electrical resistance tomography, fiber-based distributed strain, distributed temperature, and distributed acoustic monitoring, were used to carefully monitor stimulation events and flow tests. More than a dozen stimulations and nearly one year of flow tests were performed. Quality data and detailed observations were collected and analyzed during stimulation and water flow tests using ambient temperature and chilled water. We achieved adaptive control of the tests using real-time monitoring and rapid dissemination of data and near-real-time simulation. More detailed numerical simulation was performed to answer key experimental design questions, forecast fracture propagation trajectories and extents, and analyze and evaluate results. Data are freely available from the Geothermal Data Repository. Experiment 2 examines the potential for hydraulic shearing in amphibolite at a depth of about 1.25 km at SURF. This site has a different set of stress and fracture conditions than Experiment 1. The Experiment 2 testbed consists of nine subhorizontal boreholes configured in two fans of two boreholes which surround the testbed and contain grouted-in electrical resistance tomography, seismic sensors, active seismic sources and distributed fiber sensors. A “five-spot” set of test wells that extends from a custom mined alcove includes an injection well and four production/monitoring wells. The testbed was characterized geophysically and hydrologically, and three stimulations have been performed using the Step-Rate Injection Method for Fracture In-Situ Properties (SIMFIP) tool to measure strains, and a new strain quantifying tool (downhole robotic strain analysis tool -DORSA) was deployed in a monitoring hole during stimulation. Real-time data were broadcast during stimulations to allow real-time response to arising issues.

EGS Collab, Enhanced Geothermal Systems, EGS, fiel↗

Estimating Residual Solids Volume In Underground Storage Tanks

The Savannah River Site liquid waste system consists of multiple facilities to safely receive and store legacy radioactive waste, treat, and permanently dispose waste. The large underground storage tanks and associated equipment, known as the 'tank farms', include a complex interconnected transfer system which includes underground transfer pipelines and ancillary equipment to direct the flow of waste. The waste in the tanks is present in three forms: supernatant, sludge, and salt. The supernatant is a multi-component aqueous mixture, while sludge is a gel-like substance which consists of insoluble solids and entrapped supernatant. The waste from these tanks is retrieved and treated as sludge or salt. The high level (radioactive) fraction of the waste is vitrified into a glass waste form, while the low-level waste is immobilized in a cementitious grout waste form called saltstone. Once the waste is retrieved and processed, the tanks are closed via removing the bulk of the waste, chemical cleaning, heel removal, stabilizing remaining residuals with tailored grout formulations and severing/sealing external penetrations. The comprehensive liquid waste disposition system, currently managed by Savannah River Remediation, consists of 1) safe storage and retrieval of the waste as it is prepared for permanent disposition; (2) definition of the waste processing techniques utilized to separate the high-level waste fraction/low-level waste fraction; (3) disposition of LLW in saltstone; (4) disposition of the HLW in glass; and (5) closure state of the facilities, including tanks. This paper focuses on determining the effectiveness of waste removal campaigns through monitoring the volume of residual solids in the waste tanks. Volume estimates of the residual solids are performed by creating a map of the residual solids on the waste tank bottom using video and still digital images. The map is then used to calculate the volume of solids remaining in the waste tank. The ability to accurately determine a volume is a function of the quantity and quality of the waste tank images. Currently, mapping is performed remotely with closed circuit video cameras and still photograph cameras due to the hazardous environment. There are two methods that can be used to create a solids volume map. These methods are: liquid transfer mapping / post transfer mapping and final residual solids mapping. The task is performed during a transfer because the liquid level (which is a known value determined by a level measurement device) is used as a landmark to indicate solids accumulation heights. The post transfer method is primarily utilized after the majority of waste has been removed. This method relies on video and still digital images of the waste tank after the liquid transfer is complete to obtain the relative height of solids across a waste tank in relation to known and usable landmarks within the waste tank (cooling coils, column base plates, etc.). In order to accurately monitor solids over time across various cleaning campaigns, and provide a technical basis to support final waste tank closure, a consistent methodology for volume determination has been developed and implemented at SRS.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Window to the Hot Cell: The Challenges of Repairing a Specialized Nuclear Containment

Here, at the Idaho National Laboratory (INL) nuclear R&D site we come across a myriad of challenges and health hazards. Recently, a first time activity for the INL was to replace a hot cell window put in place circa 1977. This job evolution was complex in nature and involved several health and safety hazards. A hot cell is a containment designed to protect workers from radioactivity yet continue to allow work with remote handled tools and windows for visibility. The hot cell window weighed approximately 14,000 lbs. and was held in place by 1.6 cubic yards of high density grout. Removal of the window required abrasive grout removal techniques, radiological control efforts, specialized ventilation, and personal protective equipment utilization. In order to contain the large amounts of dust from the removal of concrete and potential contamination exposure a special containment tent and ventilation system was designed to protect workers in the surrounding areas from dust and debris. Once the window was removed it had to be further taken apart for shipment. While performing this activity, several lead sheets and lead wool was required to be removed. Overall it took 38 days to accomplish this task and had several organizations involved. There were no injuries or unexpected conditions that occurred during this job task. This was the first time this activity was performed at the INL and was completed in a successful manner. Further windows are set to be replaced in the near future.

99 GENERAL AND MISCELLANEOUS↗

The Use of Subsurface Barriers to Support Treatment of Metals and Reduce the Flux of Tritium to Fourmile Branch at the Savannah River Site in South Carolina - 13358

The Savannah River Site (SRS) produced tritium, plutonium, and special nuclear materials for national defense, medicine, and the space programs. Acidic groundwater plumes containing metals, metallic radionuclides, non-metallic radionuclides and tritium sourced from the F and H Area Seepage Basins have impacted the surface water of Fourmile Branch on SRS. Tritium releases from Fourmile Branch have impacted the water quality within areas of the Savannah River adjacent to the SRS, and this circumstance has been an ongoing regulatory concern. The F and H Area Seepage Basins operated until 1988 for the disposition of deionized acidic waste water from the F and H Separations Facilities. The waste water contained dilute nitric acid and low concentrations of non-radioactive metals, and radionuclides, with the major isotopes being Cs-137, Sr-90, U-235, U-238, Pu-239, Tc-99, I-129, and tritium. The tritium concentration in the waste water was relatively elevated because there is not a practicable removal method in water. The acid content of the waste water during the operational period of the basins was equal to 12 billion liters of nitric acid. The seepage basins were closed in 1988 and backfilled and capped by 1991. The plumes associated with the F and H basins cover an area of nearly 2.4 square kilometers (600 acres) and discharge along ∼2,600 meters of Fourmile Branch. The acidic nature of the plumes and their overall discharge extent along the branch represent a large challenge with respect to reducing contaminant flux to Fourmile Branch. The introduction of nitric acid into the groundwater over a long time effectively reduced the retardation of metal migration from the basins to the groundwater and in the groundwater to Fourmile Branch, because most negatively charged surfaces on the aquifer materials were filled with hydrogen ion. Two large pump and treat systems were constructed in 1997 and operated until 2003 in an attempt to capture and control the releases to Fourmile Branch. The operating cost, including waste disposal, for the two systems was ∼$1.3 M/month. Both systems employed reinjection of tritiated water up gradient of the extraction, and produced large quantities of waste from non-tritium isotopes and metals removal prior to reinjection. Both systems were determined to be ineffective and potentially detrimental with respect to limiting the flux of contaminants to Fourmile Branch. After it became apparent that there was very little benefit to continued operation of the systems, and the staggering cost of operations was recognized by the SRS and regulators, a new remedy was developed. The new system uses vertical subsurface barriers to redirect groundwater flow to limit the transport of contaminants to the stream. The barriers were constructed of acid resistant grout using deep soil mixing techniques. The grout mixture used low swelling clay, fly ash, and sodium hydroxide to form a pozzolana material with low permeability and low strength. The SRS and regulators agreed to a series of remedial goals, with the first goal to reduce tritium flux to the stream by 70% and bring constituents other than tritium to groundwater protection standards. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗