Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GLOVEBOXES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Microgravity Workstation and Restraint Evaluations

Confined workstations, where the operator has limited visibility and physical access to the work area, may cause prolonged periods of unnatural posture. Impacts on performance, in terms of fatigue and posture, may occur especially if the task is tedious and repetitive or requires static muscle loading. The glovebox design is a good example of the confined workstation concept. Within the scope of the 'Microgravity Workstation and Restraint Evaluation' project, funded by the NASA Headquarters Life Sciences Division, it was proposed to conduct a series of evaluations in ground, KC-135 and Shuttle environments to investigate the human factors issues concerning confined/unique workstations, such as gloveboxes, and also including crew restraint requirements. As part of the proposed integrated evaluations, two Shuttle Detailed Supplementary Objectives (DSOs) were manifested; one on Space Transportation System (STS)-90 and one on STS-88. The DSO on STS-90 evaluated use of the General Purpose Workstation (GPWS). The STS-88 mission was planned to evaluate a restraint system at the Remote Manipulator System (RMS). In addition, KC- 1 35 flights were conducted to investigate user/workstation/restraint integration for long-duration microgravity use. The scope of these evaluations included workstations and restraints to be utilized in the ISS environment, but also incorporated other workstations/ restraints in an attempt to provide findings/requirements with broader applications across multiple programs (e.g., Shuttle, ISS, and future Lunar-Mars programs). In addition, a comprehensive electronic questionnaire has been prepared and is under review by the Astronaut Office which will compile crewmembers' lessons learned information concerning glovebox and restraint use following their missions. These evaluations were intended to be complementary and were coordinated with hardware developers, users (crewmembers), and researchers. This report is intended to provide a summary of the findings from each of the evaluations.

Chmielewski, C.↗

g-LIMIT Status Briefing

For many microgravity science experiments in the International Space Station, the ambient acceleration environment will be exceed desirable levels. To provide a more quiescent acceleration environment to the microgravity payloads, a vibration isolation system named g-LIMIT (GLovebox Integrated Microgravity Isolation Technology) is being designed. g-LIMIT is a sub-rack level isolation system that can be tailored to a variety of applications. Scheduled for launch on the UF-1 mission, the initial implementation of g-LIMIT will be a Characterization Test in the Microgravity Science Glovebox (MSG). g-LIMIT will be available to glovebox investigators immediately after characterization testing. Standard MSG structural and umbilical interfaces will be used so that the isolation mount is transparent to the user with no additional accommodation requirements. g-LIMIT consists of three integrated isolator modules, each of which is comprised of a dual axis actuator, two axes of acceleration sensing, two axes of position sensing, control electronics, and data transmission capabilities in a minimum-volume package. In addition, this system provides the unique capability for measuring absolute acceleration of the experiment independent of accelerometers as a by-product of the control system and will have the capability of generating pristine accelerations to enhance experiment operations.

Whorton, Mark↗

Space Station Biological Research Project

NASA Ames Research Center is responsible for the development of the Space Station Biological Research Project (SSBRP) which will support non-human life sciences research on the International Space Station Alpha (ISSA). The SSBRP is designed to support both basic research to understand the effect of altered gravity fields on biological systems and applied research to investigate the effects of space flight on biological systems. The SSBRP will provide the necessary habitats to support avian and reptile eggs, cells and tissues, plants and rodents. In addition a habitat to support aquatic specimens will be provided by our international partners. Habitats will be mounted in ISSA compatible racks at u-g and will also be mounted on a 2.5 m diameter centrifuge except for the egg incubator which has an internal centrifuge. The 2.5 m centrifuge will provide artificial gravity levels over the range of 0.01 G to 2 G. The current schedule is to launch the first rack in 1999, the Life Sciences glovebox and a second rack early in 2001, a 4 habitat 2.5 in centrifuge later the same year in its own module, and to upgrade the centrifuge to 8 habitats in 2004. The rodent habitats will be derived from the Advanced Animal Habitat currently under development for the Shuttle program and will be capable of housing either rats or mice individually or in groups (6 rats/group and at least 12 mice/group). The egg incubator will be an upgraded Avian Development Facility also developed for the Shuttle program through a Small Business and Innovative Research grant. The Space Tissue Loss cell culture apparatus, developed by Walter Reed Army Institute of Research, is being considered for the cell and tissue culture habitat. The Life Sciences Glovebox is crucial to all life sciences experiments for specimen manipulation and performance of science procedures. It will provide two levels of containment between the work volume and the crew through the use of seals and negative pressure. The glovebox will accommodate use by two crew persons simultaneously and the capability for real time video down-link and data acquisition. In house testbeds and Phase B studies of the centrifuge validated the concepts of vibration isolation and autobalancing systems to meet the ISSA microgravity requirements. The vibration isolation system is effective above the centrifuge rotation frequency while the autobalancing system on the rotor removes vibration at and below the rotation rate. Torque of the Station, induced by spin-up/spindown of the centrifuge, can be minimized by controlling spin-up/spin-down rates. The SSBRP and ISSA will provide the opportunity to perform long-term, repeatable and high quality science. The long duration increments available on the Station will permit multigeneration studies of both plants and animals which have not previously been possible. The u-g habitat racks and the eight habitat centrifuge will accommodate sufficient number of specimens to permit statistically significant sampling of specimens to investigate the time course of adaptation to altered gravity environments. The centrifuge will, for the first time, permit investigators to use gravity itself as a tool to investigate fundamental processes, to investigate the intensity and duration of gravity to maintain normal structure and function, to separate the effects of u-g from other environmental factors and to examine artificial gravity as a potential countermeasure for the physical deconditioning observed during space flight.

Johnson, Catherine C.↗

Umbilical Stiffness Matrix Characterization and Testing for Microgravity Science Payloads

This paper describes efforts of testing and analysis of various candidate cables and umbilicals for International Space Station microgravity science payloads. The effects of looping, large vs. small displacements, and umbilical mounting configurations were assessed. A 3-DOF stepper motor driven fixture was used to excite the umbilicals. Forces and moments were directly measured in all three axes with a 6-DOF load cell in order to derive suitable stiffness matrices for design and analysis of vibration isolation controllers. Data obtained from these tests were used to help determine the optimum type and configuration of umbilical cables for the International Space Station microgravity science glovebox (MSG) vibration isolation platform. The data and procedures can also be implemented into control algorithm simulations to assist in validation of actively controlled vibration isolation systems. The experimental results of this work are specific in support of the Glovebox Integrated Microgravity Isolation Technology (g-LIMIT) isolation platform, to be located in the microgravity science glovebox aboard the U.S. Destiny Laboratory Module.

Engberg, Robert C.↗

Technology Development and Advanced Planning for Curation of Returned Mars Samples

NASA Johnson Space Center (JSC) curates extraterrestrial samples, providing the international science community with lunar rock and soil returned by the Apollo astronauts, meteorites collected in Antarctica, cosmic dust collected in the stratosphere, and hardware exposed to the space environment. Curation comprises initial characterization of new samples, preparation and allocation of samples for research, and clean, secure long-term storage. The foundations of this effort are the specialized cleanrooms (class 10 to 10,000) for each of the four types of materials, the supporting facilities, and the people, many of whom have been doing detailed work in clean environments for decades. JSC is also preparing to curate the next generation of extraterrestrial samples. These include samples collected from the solar wind, a comet, and an asteroid. Early planning and R\&D are underway to support post-mission sample handling and curation of samples returned from Mars. One of the strong scientific reasons for returning samples from Mars is to search for evidence of current or past life in the samples. Because of the remote possibility that the samples may contain life forms that are hazardous to the terrestrial biosphere, the National Research Council has recommended that all samples returned from Mars be kept under strict biological containment until tests show that they can safely be released to other laboratories. It is possible that Mars samples may contain only scarce or subtle traces of life or prebiotic chemistry that could readily be overwhelmed by terrestrial contamination . Thus, the facilities used to contain, process, and analyze samples from Mars must have a combination of high-level biocontainment and organic / inorganic chemical cleanliness that is unprecedented. JSC has been conducting feasibility studies and developing designs for a sample receiving facility that would offer biocontainment at least the equivalent of current maximum containment BSL-4 (BioSafety Level 4) laboratories, while simultaneously maintaining cleanliness levels equaling those of state-of-the-art cleanrooms. Unique requirements for the processing of Mars samples have inspired a program to develop handling techniques that are much more precise and reliable than the approach (currently used for lunar samples) of employing gloved human hands in nitrogen-filled gloveboxes. Individual samples from Mars are expected to be much smaller than lunar samples, the total mass of samples returned by each mission being 0.5- 1 kg, compared with many tens of kg of lunar samples returned by each of the six Apollo missions. Smaller samples require much more of the processing to be done under microscopic observation. In addition, the requirements for cleanliness and high-level containment would be difficult to satisfy while using traditional gloveboxes. JSC has constructed a laboratory to test concepts and technologies important to future sample curation. The Advanced Curation Laboratory includes a new-generation glovebox equipped with a robotic arm to evaluate the usability of robotic and teleoperated systems to perform curatorial tasks. The laboratory also contains equipment for precision cleaning and the measurement of trace organic contamination.

Lindstrom, David J.↗

Toward Lower Organic Environments in Astromaterial Sample Curation for Diverse Collections

Great interest was taken during the frenzied pace of the Apollo lunar sample return to achieve and monitor organic cleanliness. Yet, the first mission resulted in higher organic contamination to samples than desired. But improvements were accomplished by Apollo 12 [1]. Quarantine complicated the goal of achieving organic cleanliness by requiring negative pressure glovebox containment environments, proximity of animal, plant and microbial organic sources, and use of organic sterilants in protocols. A special low organic laboratory was set up at University of California Berkeley (UCB) to cleanly subdivide a subset of samples [2, 3, 4]. Nevertheless, the basic approach of handling rocks and regolith inside of a positive pressure stainless steel glovebox and restrict-ing the tool and container materials allowed in the gloveboxes was established by the last Apollo sample re-turn. In the last 40 years, the collections have grown to encompass Antarctic meteorites, Cosmic Dust, Genesis solar wind, Stardust comet grains and Hayabusa asteroid grains. Each of these collections have unique curation requirements for organic contamination monitor-ing and control. Here is described some changes allowed by improved technology or driven by changes in environmental regulations and economy, concluding with comments on organic witness wafers. Future sample return missions (OSIRIS-Rex; Mars; comets) will require extremely low levels of organic contamination in spacecraft collection and thus similarly low levels in curation. JSC Curation is undertaking a program to document organic baseline levels in current operations and devise ways to reduce those levels.

Allton, J. H.↗

Harvesting Microgreens in Microgravity: Analysis of Six Different Methods

In long duration space missions, crops will be used to supplement the astronaut diet. One such proposed crop type is microgreens, the young seedlings of edible plants that are known for their high nutritional levels, intense flavors, colorful appearance, and variety of textures. While these characteristics make microgreens a great candidate for space crop production, their small size presents a unique challenge within the microgravity environment. To ensure that astronauts will be able to harvest microgreens in microgravity with ease while avoiding the introduction of debris to the spacecraft cabin, multiple harvesting methods were developed by the Space Crop Production Team at NASA’s Kennedy Space Center. Three parabolic flights were conducted in November and December of 2021 and during those flights three different microgreen cutting methods (guillotine, pepper grinder, scissors) as well as two different bagging methods (attached and manual) were tested. In each flight, the microgreens were contained inside of a glovebox and footage of all the microgreen harvests was recorded. The cutting and bagging method combination that introduced the lowest average number of particulates into the glovebox was the scissors with attached bagging, closely followed by the pepper grinder with attached bagging. However, the scissors with attached bagging may had introduced fewer particulates into the glovebox because on average, 27% of the microgreens were never cut using the scissors method, so there were fewer free-floating particulates generated. The cutting and bagging method combination that left the lowest average percentage of microgreens remaining on the hardware post-harvest was the pepper grinder with an attached bag. Future directions include involving microgreen harvests in analog environments and further development of the different microgreen cutting and bagging methods. This research was funded by multiple NASA grants at the Kennedy Space Center.

Haley O Boles↗

Retrofit Gloveport Cover and Security Device

The world of glovebox work in the areas of science and manufacturing is in a consistent state of flux due to the inherent nature of changing missions. These rapidly changing work environments result in almost continuous regulatory changes within the codes and standards in order to maintain worker and environmental safety. Gloveboxes designed and manufactured prior to these regulations are not easy to update or retrofit to accommodate new requirements. In order to meet the challenge of retrofitting gloveboxes to the meet the requirements, the following solutions have been developed.

42 ENGINEERING↗

Nitrile O-ring Cracking: A Case of Vacuum Flange O-ring Failures

A review of recent nitrile O-ring failures in ISO-KF vacuum flange connections in glovebox applications is presented. An investigation of a single “isolated” o-ring failure leads to the discovery of cracked nitrile o-rings in a glovebox atmospheric control unit. The initial cause of the o-ring failure is attributed to ozone degradation. However, additional investigation reveals nitrile o-ring cracking on multiple gloveboxes and general purpose piping, roughly 85% of the nitrile o-rings removed for inspection show evidence of visible cracking after being in service for 18 months or less. The results of material testing and ambient air testing is presented, elevated ozone levels are not found. The contributing factors of o-ring failure, including nitrile air sensitivity, inadequate storage practices, and poor installation techniques, are discussed. A discussion of nitrile o-ring material properties, the benefits and limitations, and alternate materials are discussed. Considerations for o-ring material selection, purchasing, storage, and installation are presented in the context of lessons learned from the nitrile o-ring cracking investigation. This paper can be presented in 20 minutes and does not require special accommodations or special audio visual devices.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Development of a Small Liquid Sodium Purification Loop

Generation IV nuclear reactors provide management solutions to address spent fuel problems. The most researched Generation IV reactor is the sodium cooled fast reactor (SFR). Improved engineering is has allowed for systematic improvements in both the safety and efficiency of power production. However, before a SFR can be brought back online in the Untied States, constructive research must be pursued on numerous scales to ensure the capabilities of aforementioned reactors. While larger research facilities such as the one at Argonne National Laboratory or the University of Wisconsin - Madison address some of the larger scale studies surrounding the SFR, Fort Lewis College (FLC) is aiming to provide small scale studies on liquid sodium as a thermal hydraulic cooling system. The sodium diagnostic loop at FLC is constructed to conduct research that includes: analyzing pumping characteristics, thermal stratification, freeze plug analysis, and corrosion studies. The FLC loop is attached to an inert glovebox so these experiments can be conducted with an additional layer of safety. The objective of this sodium research apparatus is to combine the best features of each instrument commonly associated with sodium research loops in a cost effective manner while still obtaining high fidelity data. Furthermore, an innovative design of the loop maximizes the volume of available research space inside of the glovebox by mounting the diagnostic loop adjacent to the glovebox.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

WE-AB-BRB-05: Toward a 2D Water-Equivalent Dosimetry Panel Using KCl:Eu2+

Purpose: KCl:Eu2+ storage phosphor shows promise for radiation therapy dosimetry. The purpose of this work is to investigate several important aspects of this material for potential commercial use. Methods: KCl:Eu2+ chips were fabricated and a conformal coating using Parylene was applied. Material’s dose response in a 6 MV beam was investigated using Monte-Carlo simulations. We attempted to micronize the materials using a spiral jet mill. As we did not have a water-free glovebox, we used commercially available non-hygroscopic BaFBr0.85I0.15:Eu2+ computed radiography material to test if a homogeneous panel can be made using micron-sized phosphors. Results: Dosimeters remained intact and showed no change in PSL intensity after eight hrs of submersion in water. We then optically bleached the samples for reuse, irradiated and immersed for another 24 hrs. We observed marginal worsening of the PSL signal for both the soaked and un-soaked chips. By contrast, we were unable to measure PSL intensity of the un-coated pellets due to these pellets dissolving within minutes of being immersed in water. MC data indicate that the micron-sized KCl:Eu2+ is predicted to have a nearly water-equivalent response. KCl:Eu2+ particles with a median size of 3 microns can be produced using a jet mill, which could be reduced further if necessary. While the particles tend to agglomerate over time when stored in a desiccator, they still possess favorable d50’s and d99’s even after 100 minutes, providing an adequate time window for making a panel via tape casting. A panel cast using optimized methods exhibits nearly perfect particle arrangement. Conclusions: Data shown here support ongoing efforts in fabricating a reusable, high resolution dosimetry panel in a water-free glovebox using micron-sized KCl:Eu2+ particles separated by water-equivalent polymers. The conformal coating thereafter will provide good humidity resistance. HL is the founder of DoseImaging, LLC that is exclusively dedicated to commercializing this technology.

60 APPLIED LIFE SCIENCES↗

Final Report For PDRD SR16009: Durable Water Splitting Using Thermochemical Cycles Of Nanostructured Metal Oxides

The Tritium Facility process for stripping tritium from the glovebox atmosphere currently relies on the use of hot magnesium beds (mag beds) to “crack” tritiated water, releasing hydrogen isotopes as a gas. This is a safe and effective process for recovering hydrogen isotopes from water for further processing. However, due to the thermodynamic properties of magnesium, mag beds are single use - once the magnesium metal is converted to magnesium oxide the bed must be replaced. Replacing mag beds is a labor-intensive and operationally complex task. In order to streamline operations and reduce costs, it is desirable to develop a reusable system that recovers hydrogen isotopes from water, while safely sequestering oxygen in a stable form. The following document reviews the results from the Plant Directed Research, Development, and Demonstration (PDRD) project “Durable Water Splitting using Thermochemical Cycles of Nanostructured Metal Oxides” (SR16009), which had the specific goal of developing a process for stripping tritium from the glovebox atmosphere that eliminates magnesium beds.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High-pressure and high-temperature tritium apparatus for the tritiation of materials

A tritium exposure apparatus has been designed and built for the purposes of generating a high-pressure tritium atmosphere at 523 K. The loading system consists of a uranium tritide storage bed, an intermediate tritium transfer chamber filled with 5A molecular sieve, and the sample exposure chamber. The loading system resides in a sealed glovebox with a nitrogen atmosphere that is continually purged through a Glovebox Clean-up System. The tritium used in each loading experiment is approximately 6000 Ci (22 TBq). The process entails transferring the tritium inventory from the uranium storage bed to the cryogenically cooled (77 K) molecular sieve chamber. The molecular sieve at liquid nitrogen temperature is capable of adsorbing tritium to densities of 290 Ci/gram at one atmosphere. At 523 K a maximum tritium pressure of 21 MPa is achieved. The loading apparatus is used to develop high-density radioactive isotope fuel for self-powered microelectronic and micromechanical devices. This paper presents the design specifics of the tritium exposure apparatus, the steps taken in generating the high-temperature, high-pressure tritium atmosphere and the performance characteristics of the apparatus. Additionally, the handling practices and equipment utilized to conduct the tests safely are presented. (authors)

42 ENGINEERING↗

Augmented Reality Tools for Nuclear Facilities - 18318

In this work we explore the possibility of improving nuclear facility operations through the use of emerging augmented reality technology. Specifically we focus on the use of augmented reality headsets. Augmented reality opens up the possibility for easy, on-the-fly access to documentation related to canisters, rooms, and carts. It also can be used to help plan complicated material moves in ways that do not violate nuclear criticality safety regulations. Modern augmented reality technology can also be interacted with using gaze, gesture and voice commands, thus making it particularly attractive for facilitating the documentation of nuclear material operations and work verification. An augmented reality-based nuclear facility criticality safety system would have a number of benefits for operations in nuclear facilities. This work could be used across the DOE complex to ensure technicians in gloveboxes work safely and securely. It could greatly reduce downtime associated with administrative criticality incidents. It would be a step forward in the process of improving the quality of documentation of the work that occurs in nuclear facilities while simultaneously increasing the ease with which this documentation can be collected. The augmented reality effectively endows the glovebox technicians with a sense for administrative nuclear criticality safety and the reactivity changes caused directly by their actions. Augmented reality also has great potential for facilitating inspections of nuclear infrastructure. Examples of Augmented Reality applications that facilitate infrastructure inspection and work verification will also be presented. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Environmental and Radiological Readiness of Fixatives, Foams, and Intumescent Coatings for D and D Applications - 18553

During D and D operations of legacy nuclear facilities, the ability to effectively stabilize contamination in large cavities is a significant challenge. For items that must be removed, such as gloveboxes and entry hoods, a method of simply filling the volume to stabilize any residual contamination after contamination efforts have concluded would be of great benefit, and further the As Low As Reasonably Achievable (ALARA) culture of the DOE complex. The development, testing, and characterization of commercial fixatives and foams for applicability towards fixating contamination provides a potential structural reinforcement and fire resiliency in legacy nuclear facility equipment. Much of the equipment, such as gloveboxes, shielded cells, and radiological hoods left over from nuclear processing leave large cavities. Filling these voids after decontamination efforts provides a means of shielding workers from excess radiation exposure while immobilizing residual contamination. As such, we look to continue the development of fixatives/intumescent coatings from the previous year and test commercially available polymer-based foam products for use in filling these cavities, providing a secondary level of protection and shielding during the D and D process This research is funded as part of the In-Situ Decommissioning and Technology Development and sponsored by DOE- Office of Environmental Management Technology Development. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

ROV used in Sludge Retrieval and Treatment Project - 18575

The Orano-operated waste treatment site at La Hague, France, has treated large quantities of nuclear waste through-out its many decades of operation. During a period of over twenty years, a significant amount of the radioactive sludge resulting from the liquid waste treatment processes was placed into a set of adjoining tanks, called the STE2 silos. Now that those tanks are reaching capacity, a project has begun to retrieve this waste, transfer it to another location for homogenisation and characterization, and to then send it to another facility for conditioning and long-term storage. Because of the conditions inside and around these tanks, the waste retrieval process has many limitations. For example, the high radiation levels require that the retrieval be done efficiently, with a high removal rate and that operation be done remotely. The sludge retrieval tool will be operated and navigated while hidden inside the tank, under a significant amount of supernatant liquid, but needs to be accessible for maintenance and modifications and able to be transferred from one tank to the next. Additionally, the highly viscous consistency of the sludge requires special suction capabilities. All of these conditions need to be met, by a system that fits into the tanks' 900 mm (<3 ft) access ports. After almost three years of profound engineering, construction and testing efforts, a final design has been approved. The tool consists of a 250 kg (∼550 lb), remotely-operated vehicle (ROV) with an Archimedes-type screw attachment. It is delivered into and retrieved from the tank through a shielded glovebox that allows for maintenance and exchange of attachments. Sludge is sucked through a rotating screw and out a second tank opening with a consideration for limiting external water usage. To locate and navigate the tool, cameras detect LEDs attached to the ROV's buoys, and then calculate the ROV's position and orientation. With preliminary design and testing of the prototype complete, the project is preparing to award the ROV manufacturing contract and finalize the design of auxiliary systems, such as the rinsing and maintenance processes and localization instrumentation. After extensive final testing, the gloveboxes will be placed over the tanks in mid-2020, with entry into the first tank expected in April 2024. The ideas and experiences Orano is currently gathering during this effort will be of interest to laboratories and facilities that will soon be retrieving waste sludge from their aging storage tanks. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Oxidizer Testing on Alternative Absorbents for Los Alamos National Laboratory - 18656

In the summer of 2016, during glovebox operations in TA-55, cheesecloth, a cellulosic material, was used to clean up a small spill of 9.8 molar nitric acid (oxidizer). Because cellulosic materials and oxidizers are incompatible, this prompted a chemical compatibility evaluation of the waste in TA-55 to determine if this waste was Resource Conservation and Recovery Act (RCRA) ignitable waste (D001) or RCRA reactive waste (D003). After testing and consulting with the Carlsbad Field Office in Carlsbad (CBFO), Los Alamos National Laboratory (LANL) NPI-7 decided to look for alternative absorbents to use in the gloveboxes that would not create an incompatibility issue with an oxidizer. While small spills are infrequent, they do happen and LANL wanted to be proactive and search for a material that would be compatible with an oxidizer. In December 2016, LANL NPI-7 requested LANL-Carlsbad's (LANL-CO) Difficult Waste Team to perform compatibility testing on potential alternative wipes for disposal at the Waste Isolation Pilot Plant (WIPP). The purpose for testing was to meet the Operational Experience Level 3 (OE-3) requirements that states 'any proposed use of organic absorbents or engineered absorbents in combination with potentially oxidizing TRU waste, wet or dry, should be evaluated and approved by the National TRU Program, Carlsbad Field Office' [1]. LANL NPI-7 requested LANL-CO to perform these tests because they were the group that performed all of the oxidizer testing for CBFO for the Basis of Knowledge (BoK) [2]. LANL NPI-7 chose nine fabrics and KMI Zeolite to be tested. The testing in Carlsbad took approximately 2 months to prepare the procedures, test plans and for the procurement of items. The burn rate testing was done in accordance with the requirements discussed in the BoK and approved by the LANL-CO Difficult Waste Team. Each absorbent was tested for 1) capacity limiting tests, 2) verifying the non-oxidizer threshold concentration of the oxidizer and 3) establishing the non-oxidizer concentration based on the experimental results. The effect of rinsing cheesecloth samples that have absorbed an oxidizer was also tested [3]. The burn rate testing provided three potential alternative absorbents (Spilfyter Hazmat Sorbent SM Pads Premium, Kimtech Pure W4 Wipers and Polybenzimidazole (PBI) Staple fiber) that produced a non-oxidizer result as defined by the BoK. Two wipes Spilfyter Hazmat Sorbent SM Pads Premium and Kimtech Pure W4 Wipers were able to absorb the highest concentration of potassium nitrite and still produce a non-oxidizer. TA-55 has used Spilfyter Hazmat Sorbent SM Pads Premium for a number of years in several of the processes and has ordered Kimtech Pure W4 Wipers for use in the facility. PBI fabric passed at 25 wt. % solution. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

MPF X-Ray Module Setup for 2018

The Mobile Plutonium Facility (MPF) is a portable module design facility that can be deployed anywhere in the world for the safe recovery, packaging, and shipment of a nations legacy, or excess plutonium stockpile. All of the modules of MPF have specific purposes for operating in a mission if one were to ever come up. For my past four internships here at SRNL I have been working on the support of the X-Ray module for MPF. This year I installed new equipment I had purchased last year for the X-Ray Module and made sure the module was mission ready for the chance that the team deploys in the future for plutonium recovery. Using digital radiography (DR) and computed tomography (CT) provides the MPF team the ability to verify the contents of containers that would be holding material. This also ensures the safety of the team members in the glovebox facilities by verifying that there are no sharps, liquids, or other items that may harm the workers or glovebox operations when working with radioactive material. X-Ray imaging can also pick up low density objects like plastic bags and tape. Note how the DR image hides the puncture in the inner can while the CT image shows the damage. New DR and CT computers with upgraded software, New imaging panel, NOVO Portable X-Ray System. Because of the new upgrades to the X-Ray module system containers can be scanned and evaluated quicker than before. With the last system the 3D model reconstruction alone would take anywhere from 10-12 minutes, now with the new system that time has been brought down to just shy of 1 minute 30 seconds. The new portable system also can 1,2 or 4 images of an object and stitch them together into a mosaic for scanning of larger containers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗