Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GAS INJECTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Status of R&D on Mitigating the Effects of Pressure Waves for the Spallation Neutron Source Mercury Target

The Spallation Neutron Source (SNS) at the Oak Ridge National Laboratory has been conducting R&D on mitigating the effects of pressure waves in mercury spallation targets since 2001. More precisely, cavitation damage of the target vessel caused by the short beam pulse threatens to limit its lifetime more severely than radiation damage as well as limit its ultimate power capacity and hence its neutron intensity performance. The R&D program has moved from verification of the beam-induced damage phenomena to study of material and surface treatments for damage resistance to the current emphasis on gas injection techniques for damage mitigation. Two techniques are being worked on: injection of small dispersed gas bubbles that mitigate the pressure waves volumetrically; and protective gas walls that isolate the vessel from the damaging effects of collapsing cavitation bubbles. The latter has demonstrated good damage mitigation during in-beam testing with limited pulses, and adequate gas wall coverage at the beam entrance window has been demonstrated with the SNS mercury target flow configuration using a full scale mercury test loop. A question on the required area coverage remains which depends on results from SNS target post irradiation examination. The small gas bubble technique has been less effective during past in-beam tests but those results were with un-optimized and un-verified bubble populations. Another round of in-beam tests with small gas bubbles is planned for 2011. The first SNS target was removed from service in mid 2009 and samples were cut from two locations at the target s beam entrance window. Through-wall damage was observed at the innermost mercury vessel wall (not a containment wall). The damage pattern suggested correlation with the local mercury flow condition which is nearly stagnant at the peak damage location. Detailed post irradiation examination of the samples is under way that will assess the erosion and measure irradiation-induced changes in mechanical properties. Similar samples were cut from the second SNS target after it was removed from service in mid 2010. More extensive damage was observed on the target inner wall but damage to the containment wall was minimal.

cavitation↗

Effects of Mass Addition on the Stability of Slender Cones at Hypersonic Speeds

The effect of mass addition on the flow over bodies moving at hypersonic speeds has been studied by several investigators (e.g., Cresci and Libby). In most of this work, primary attention logically has been directed toward the effects of foreign-gas injection on heat transfer and pressure distributions, and, principally for this reason, most of the work ha been done at zero angle of attack. The foreign gas can be provided either by some active injection system or by the action of an ablation heat shield. With increasing rates of injection, the basic flow about the body can be affected significantly. One such effect was observed in the paper by Cresci and Libby, where it was shown that the shockwave standoff distance can be increased by gas injection at the nose of a body.

SLENDER BODY↗

Alternative Techniques for Injecting Massive Quantities of Gas for Plasma Disruption Mitigation

Injection of massive quantities of noble gases or D2 has proven to be effective at mitigating some of the deleterious effects of disruptions in tokamaks. Two alternative methods that might offer some advantages over the present technique for massive gas injection are shattering massive pellets and employing closecoupled rupture disks. Laboratory testing has been carried out to evaluate their feasibility. For the study of massive pellets, a pipe gun pellet injector cooled with a cryogenic refrigerator was fitted with a relatively large barrel (16.5 mm bore), and D2 and Ne pellets were made and were accelerated to speeds of ~600 and 300 m/s, respectively. Based on the successful proof-of-principle testing with the injector and a special double-impact target to shatter pellets, a similar system has been prepared and installed on DIII-D, with preliminary experiments already carried out. To study the applicability of rupture disks for disruption mitigation, a simple test apparatus was assembled in the lab. Commercially available rupture disks of 1 in. nominal diameter were tested at conditions relevant for the application on tokamaks, including tests with Ar and He gases and rupture pressures of ~54 bar. Some technical and practical issues of implementing this technique on a tokamak are discussed.

disruption↗

Rapid hydrogen gas generation using reactive thermal decomposition of uranium hydride.

Oxygen gas injection has been studied as one method for rapidly generating hydrogen gas from a uranium hydride storage system. Small scale reactors, 2.9 g UH{sub 3}, were used to study the process experimentally. Complimentary numerical simulations were used to better characterize and understand the strongly coupled chemical and thermal transport processes controlling hydrogen gas liberation. The results indicate that UH{sub 3} and O{sub 2} are sufficiently reactive to enable a well designed system to release gram quantities of hydrogen in {approx} 2 seconds over a broad temperature range. The major system-design challenge appears to be heat management. In addition to the oxidation tests, H/D isotope exchange experiments were performed. The rate limiting step in the overall gas-to-particle exchange process was found to be hydrogen diffusion in the {approx}0.5 {mu}m hydride particles. The experiments generated a set of high quality experimental data; from which effective intra-particle diffusion coefficients can be inferred.

08 HYDROGEN↗

Gas Lift Petroleum Extraction

Petroleum production by injecting gas into production tubing. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=8AFC95C8-1D61-4191-B18F-01512E7C5AE8

02 PETROLEUM↗

First demonstration of rapid shutdown using neon shattered pellet injection for thermal quench mitigation on DIII-D

Shattered pellet injection (SPI) is one of the prime candidates for the ITER disruption mitigation system because of its deeper penetration and larger particle flux than massive gas injection (MGI) using deuterium. Here, the ITER disruption mitigation system will likely use mostly high Z species such as neon because of more effective thermal mitigation and pumping constraints on the maximum amount of deuterium or helium that could be injected. An upgrade of the SPI on DIII-D enables ITER relevant injection characteristics in terms of quantities and gas species. This upgraded SPI system was used on DIII-D for the first time in 2014 for a direct comparison with MGI using identical quantities of neon.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of Long-Lifetime Pulsed Gas Valves for Pulsed Electric Thrusters

It is advantageous for gas-fed pulsed electric thrusters to employ pulsed valves so propellant is only flowing to the device during operation. The propellant utilization of the thruster will be maximized when all the gas injected into the thruster is acted upon by the fields produced by the electrical pulse. Gas that is injected too early will diffuse away from the thruster before the electrical pulse can act to accelerate the propellant. Gas that is injected too late will miss being accelerated by the already-completed electrical pulse. As a consequence, the valve must open quickly and close equally quickly, only remaining open for a short duration. In addition, the valve must have only a small amount of volume between the sealing body and the thruster so the front and back ends of the pulse are as coincident as possible with the valve cycling, with very little latent propellant remaining in the feed lines after the valve is closed. For a real mission of interest, a pulsed thruster can be expected to pulse at least 10(exp 10) - 10(exp 11) times, setting the range for the number of times a valve must open and close. The valves described in this paper have been fabricated and tested for operation in an inductive pulsed plasma thruster (IPPT) for in-space propulsion. In general, an IPPT is an electrodeless space propulsion device where a capacitor is charged to an initial voltage and then discharged, producing a high-current pulse through a coil. The field produced by this pulse ionizes propellant, inductively driving current in a plasma located near the face of the coil. Once the plasma is formed, it can be accelerated and expelled at a high exhaust velocity by the electromagnetic Lorentz body force arising from the interaction of the induced plasma current and the magnetic field produced by the current in the coil. The valve characteristics needed for the IPPT application require a fast-acting valve capable of a minimum of 10(exp 10) valve actuation cycles. Since even 10(exp 9) cycles is well above anything demonstrated, this lower value was selected as the design point for the present work. The valve seal must remain leak-tight throughout operation, and the body must maintain a low internal leakage at relatively high operating temperatures. The full set of design requirements used for this program are summarized in Table 1. In this work, we describe two pulsed gas valves that have been fabricated to have long lifetime and demonstrate the characteristics listed above. The first is a miniaturized, conventional electromagnet-based valve while the second is a piezoelectric-based valve design. The conventional valve, shown in Fig. 1, is opened by use of a solenoid electromagnetic actuator. When current is applied to the solenoid coil, magnetic forces pull the plunger away from the valve seat, allowing fluid to flow through the valve. Removal of electrical current permits the spring and fluid pressure to seat the plunger, halting the flow of fluid. The valve body is fabricated from 304L corrosion resistant steel (CRES) and while the parts that form the magnetic circuit are fabricated from 430 CRES. This material does not have optimum magnetic properties, but its corrosion resistance permits incorporation into a design without requiring an additional plating process. A viton O-ring compound (Parker V0884-75), selected for its mechanical strength at elevated temperatures, was used for the valve seat seal. The design was based solely on the use of analytical sizing calculations, as opposed to a more rigorous finite element analysis. While this valve is small and relatively lightweight, it does not represent a design that is optimized for mass and/or a given volume envelope. The piezoelectric valve is a "puller" valve design. Applying a voltage to the piezo crystal causes it to elongate and pull a pintle off the seat, opening the valve. The valve seal consists of the pintle with an external, spherically-formed tip fabricated from Inconel 625 and the seat fabricated from Inconel 718 and possessing a spherical surface that permits the pintle to align with the valve body centerline after each cycle, maintaining the circumferential metal-on-metal seal. The contact stress on the valve pintle is expected in the worst case to be 96.5 MPa (14 ksi), which is well below the work hardening value of 413.7 MPa (60 ksi) for Inconel 615. Results presented in this work will compare the performance of each valve, both to each other and to the valve design requirements given in Table 1. In general, both valves meet all the performance envelope requirements, but the piezoelectric valve consumes considerably less power and has a faster response time over the conventional solenoid-driven valves.

Burkhardt, Wendel M.↗

Apparatus and method for generating large mass flow of high temperature air at hypersonic speeds

High temperature, high mass air flow and a high Reynolds number test air flow in the Mach number 8-10 regime of adequate test flow duration is attained by pressurizing a ceramic-lined storage tank with air to a pressure of about 100 to 200 atmospheres. The air is heated to temperatures of 7,000 to 8,000 R prior to introduction into the tank by passing the air over an electric arc heater means. The air cools to 5,500 to 6,000 R while in the tank. A decomposable gas such as nitrous oxide or a combustible gas such as propane is injected into the tank after pressurization and the heated pressurized air in the tank is rapidly released through a Mach number 8-10 nozzle. The injected gas medium upon contact with the heated pressurized air effects an exothermic reaction which maintains the pressure and temperature of the pressurized air during the rapid release.

Sabol, A. P.↗

A method for direct, semi-quantitative analysis of gas phase samples using gas chromatography-inductively coupled plasma-mass spectrometry

A new and complete GC–ICP-MS method is described for direct analysis of trace metals in a gas phase process stream. The proposed method is derived from standard analytical procedures developed for ICP-MS, which are regularly exercised in standard ICP-MS laboratories. In order to implement the method, a series of empirical factors were generated to calibrate detector response with respect to a known concentration of an internal standard analyte. Calibrated responses are ultimately used to determine the concentration of metal analytes in a gas stream using a semi-quantitative algorithm. The method was verified using a traditional gas injection from a GC sampling valve and a standard gas mixture containing either a 1 ppm Xe + Kr mix with helium balance or 100 ppm Xe with helium balance. Data collected for Xe and Kr gas analytes revealed that agreement of 6–20% with the actual concentration can be expected for various experimental conditions. To demonstrate the method using a relevant “unknown” gas mixture, experiments were performed for continuous 4 and 7 hour periods using a Hg-containing sample gas that was co-introduced into the GC sample loop with the xenon gas standard. System performance and detector response to the dilute concentration of the internal standard were pre-determined, which allowed semi-quantitative evaluation of the analyte. The calculated analyte concentrations varied during the course of the 4 hour experiment, particularly during the first hour of the analysis where the actual Hg concentration was under predicted by up to 72%. Calculated concentration improved to within 30–60% for data collected after the first hour of the experiment. Similar results were seen during the 7 hour test with the deviation from the actual concentration being 11–81% during the first hour and then decreasing for the remaining period. The method detection limit (MDL) was determined for the mercury by injecting the sample gas into the system following a period of equilibration. The MDL for Hg was calculated as 6.8 μg · m -3 . This work describes the first complete GC–ICP-MS method to directly analyze gas phase samples, and detailed sample calculations and comparisons to conventional ICP-MS methods are provided.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Aerodynamics of a slender axisymmetric Bunsen flame with large gas expansion

The flow around a stationary axisymmetric premixed flame attached to a plug flow Bunsen burner and propagating with a constant burning velocity relative to the fresh gas is analyzed for large values of the ratio of fresh gas injection velocity to flame burning velocity and small values of the burnt-to-fresh gas density ratio. The shape of the flame is close to a cone of small semiangle, and its presence induces only a small perturbation in the fresh gas. The velocity of the burnt gas is the superposition of a uniform axial velocity and the velocity induced by a line of sources on the axis of the burner. The pressure of the burnt gas on the flame is the sum of a uniform part that does not change the velocity of the fresh gas and a small variable part that causes a vertical acceleration of this gas and a slight deformation of the flame. Only a weak vorticity is generated at the flame. The analysis breaks down in small regions around the tip and the base of the flame where the assumption of a constant burning velocity is not valid. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Water alternative gas (WAG) optimization for a heterogeneous Brazilian pre-salt carbonate reservoir

Water alternating gas (WAG) is a cyclical process that involves alternating water and gas injections with the primary goal to improve sweep efficiency by maintaining initial high pressure, slowing water and gas breakthrough, and lowering oil viscosity. The objective of this work is to apply and optimize a WAG strategy on a carbonate field with light oil, compare it to the initially planned water-flooding strategy, and investigate the capability of WAG to improve field production. In this research, a compositional reservoir simulator was used to model a WAG process by injecting produced gas into the reservoir, using the same well structure as an optimized water-flooding strategy. Subsequently, a WAG strategy was created, optimizing the number and locations of wells, to facilitate a comparative analysis of the two recovery methods. The WAG optimization involved a detailed assessment of variables such as bottom hole pressure (BHP), WAG cycle duration, maximum gas oil ratio (GOR), and well positioning, to achieve a high net present value (NPV). The study focuses on the application of WAG optimization modeling in unconventional reservoirs, specifically pre-salt carbonate reservoirs, and investigates its implications on production strategy and forecast, emphasizing its potential for maximizing NPV and oil recovery in a recently producing field. The results showed that WAG improved reservoir performance when compared to water injection and produced a greater amount of oil. This solution showed potential to be tested under uncertainties (reservoir heterogeneity, faults, fractures, karsts, vugs, etc.) as future steps.

54 ENVIRONMENTAL SCIENCES↗

Effect of Low Temperature Nitrogen Baking on Superconducting Radio Frequency Cavities With Different Frequency

We report the rf performance of several single-cell superconducting radiofrequency cavities frequency ranging from 1.3-3.0 GHz after low temperature baking in nitrogen environment The cavities are treated at different temperature in the range of (120-160oC) for extended period of time (~24-48 hours) with nitrogen gas injection in the furnace. The improvement in Q0 with Q-rise in some case was observed when nitrogen gas was injected at elevated temperature (~250-290 oC) and held at the temperature range 120-200 oC without any degradation in accelerating gradient over the baseline performance. The temperature and time of baking play significant role in dependence of quality factor on accelerating gradient.

Khanal, B.↗

Forged Ingot Niobium Technology for Accelerator Applications and Scientific Frontiers

We report the rf performance of several single-cell superconducting radiofrequency cavities frequency ranging from 1.3-3.0 GHz after low temperature baking in nitrogen environment The cavities are treated at different temperature in the range of (120-160oC) for extended period of time (~24-48 hours) with nitrogen gas injection in the furnace. The improvement in Q0 with Q-rise in some case was observed when nitrogen gas was injected at elevated temperature (~250-290 oC) and held at the temperature range 120-200 oC without any degradation in accelerating gradient over the baseline performance. The temperature and time of baking play significant role in dependence of quality factor on accelerating gradient.

Khanal, B.↗

Cluster ion source for external injection and high capacity filling of light elements into the relativistic heavy ion collider electron beam ion source

An advanced Electron Beam Ion Source (EBIS) is the primary ion source to supply highly charged ion beams of different elements to the Relativistic Heavy Ion Collider (RHIC) and to the NASA Space Radiation Laboratory (NSRL). Intense beams of highly charged ions of various elements of the periodic table, ranging from helium to uranium, have been demonstrated since EBIS became operational in 2010. EBIS routinely provides ion beams to RHIC and NSRL quasisimultaneously with about 1 s switching time between different ion species. Such unique flexibility and rapid switching between ion species are based on external injection of singly charged ions into the EBIS trap either in “fast” or “slow” injection modes. At present, a Laser Ion Source (LIS) provides most of the ion species of solid materials using the “fast” injection mode into the EBIS trap and a Hollow Cathode Ion Source (HCIS) provides most of the ion species of gaseous elements using the “slow” injection mode into the EBIS trap. Gas injection into the EBIS trap is also possible and has been used but imposes some restrictions for the simultaneous generation of highly charged ions such as Au 32+ ions for RHIC and ions of gaseous species for NSRL. Because light ions have relatively high velocity inside the EBIS trap, efficient injection of hydrogen and helium ions and filling of the EBIS trap to high capacity is difficult from either LIS or HCIS. To overcome this restriction and enhance EBIS operational capability, we suggest injecting beams of hydrogen and helium cluster ions into the EBIS trap. Required parameters of cluster ion beam injection into the EBIS trap are estimated, and advantages of such an injection are highlighted. A cluster ion source with required high intensity is visible and will be designed, built, optimized, and tested.

43 PARTICLE ACCELERATORS↗