Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “G&C”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Nanotechnology for catalysis and solar energy conversion

This roadmap on Nanotechnology for Catalysis and Solar Energy Conversion focuses on the application of nanotechnology in addressing the current challenges of energy conversion: 'high efficiency, stability, safety, and the potential for low-cost/scalable manufacturing' to quote from the contributed article by Nathan Lewis. This roadmap focuses on solar-to-fuel conversion, solar water splitting, solar photovoltaics and bio-catalysis. It includes dye-sensitized solar cells (DSSCs), perovskite solar cells, and organic photovoltaics. Smart engineering of colloidal quantum materials and nanostructured electrodes will improve solar-to-fuel conversion efficiency, as described in the articles by Waiskopf and Banin and Meyer. Semiconductor nanoparticles will also improve solar energy conversion efficiency, as discussed by Boschloo et al in their article on DSSCs. Perovskite solar cells have advanced rapidly in recent years, including new ideas on 2D and 3D hybrid halide perovskites, as described by Spanopoulos et al 'Next generation' solar cells using multiple exciton generation (MEG) from hot carriers, described in the article by Nozik and Beard, could lead to remarkable improvement in photovoltaic efficiency by using quantization effects in semiconductor nanostructures (quantum dots, wires or wells). These challenges will not be met without simultaneous improvement in nanoscale characterization methods. Terahertz spectroscopy, discussed in the article by Milot et al is one example of a method that is overcoming the difficulties associated with nanoscale materials characterization by avoiding electrical contacts to nanoparticles, allowing characterization during device operation, and enabling characterization of a single nanoparticle. Besides experimental advances, computational science is also meeting the challenges of nanomaterials synthesis. The article by Kohlstedt and Schatz discusses the computational frameworks being used to predict structure–property relationships in materials and devices, including machine learning methods, with an emphasis on organic photovoltaics. The contribution by Megarity and Armstrong presents the 'electrochemical leaf' for improvements in electrochemistry and beyond. In addition, biohybrid approaches can take advantage of efficient and specific enzyme catalysts. These articles present the nanoscience and technology at the forefront of renewable energy development that will have significant benefits to society.

14 SOLAR ENERGY↗

Trimerized small-molecule acceptors enable high-performance organic solar cells with high open-circuit voltage and prolonged life-time

Although the recent development of Y-series small-molecule acceptors (SMAs) has led to a dramatic increase in the power conversion efficiency (PCE) of organic solar cells (OSCs), the operational stability (device lifetime) of OSCs is inadequate for commercialization. In this study, we develop a new trimer acceptor (TYT), consisting of three Y-based molecules linked by electron-donating spacers, to realize an OSC with high-performance (PCE > 18%) and -stability (t 80% lifetime > 8000 h under 1 sun illumination, in which t 80% lifetime is the time required for the PCE of the OSC to reach 80% of its initial value). We demonstrate that the trimerization approach affords an acceptor, TYT, with an upshifted lowest unoccupied molecular orbital energy level, which, in turn, affords an efficient OSC with a high open-circuit voltage (0.964 V). In addition, the glass-transition temperature (T g ) of TYT (217 °C) is significantly higher than those of monomer (MYT, T g = 80 °C) and dimer (DYT, T g = 127 °C) acceptors, which effectively suppresses the molecular diffusion of TYT in a blend film with a polymer donor. Accordingly, a TYT-based OSC demonstrates a high PCE (18.2%) and long t 80% lifetime under 1 sun illumination (8454 h), outperforming MYT- and DYT-based OSCs that exhibit PCEs and t 80% lifetimes of 16.4% and 35 h, and 17.3% and 2551 h, respectively. Therefore, this study provides important guidelines for the design of electron acceptors in achieving OSCs with high performance and stability close to a commercial level.

14 SOLAR ENERGY↗

Results and Limits of Time-Division Multiplexing for the BICEP Array High-Frequency Receivers

Time-division multiplexing is the readout architecture of choice for many ground and space experiments, as it is a very mature technology with proven outstanding low-frequency noise stability, which represents a central challenge in multiplexing. Once fully populated, each of the two BICEP Array high-frequency receivers, observing at 150 GHz and 220/270 GHz, will have 7776 TES detectors tiled on the focal plane. The constraints set by these two receivers required a redesign of the warm readout electronics. The new version of the standard multichannel electronics, developed and built at the University of British Columbia, is presented here for the first time. BICEP Array operates time-division multiplexing readout technology to the limits of its capabilities in terms of multiplexing rate, noise and cross talk, and applies them in rigorously demanding scientific application requiring extreme noise performance and systematic error control. Finally, future experiments like CMB-S4 plan to use TES bolometers with time-division/SQUID-based readout for an even larger number of detectors.

47 OTHER INSTRUMENTATION↗

Optical Characterization of the Keck Array and BICEP3 CMB Polarimeters from 2016 to 2019

The BICEP/Keck experiment (BK) is a series of small-aperture refracting telescopes observing degree-scale cosmic microwave background (CMB) polarization from the South Pole in search of a primordial B-mode signature. This B-mode signal arises from primordial gravitational waves interacting with the CMB and has amplitude parametrized by the tensor-to-scalar ratio r. Since 2016, BICEP3 and the Keck Array have been observing with 4800 total antenna-coupled transition-edge sensor detectors, with frequency bands spanning 95, 150, 220, and 270 GHz. Here we present the optical performance of these receivers from 2016 to 2019, including far-field beams measured in situ with an improved chopped thermal source and instrument spectral response measured with a field-deployable Fourier transform spectrometer. As a pair differencing experiment, an important systematic that must be controlled is the differential beam response between the co-located, orthogonally polarized detectors. We generate per-detector far-field beam maps and the corresponding differential beam mismatch that is used to estimate the temperature-to-polarization leakage in our CMB maps and to give feedback on detector and optics fabrication. The differential beam parameters presented here were estimated using improved low-level beam map analysis techniques, including efficient removal of non-Gaussian noise as well as improved spatial masking. These techniques help minimize systematic uncertainty in the beam analysis, with the goal of constraining the bias on r induced by temperature-to-polarization leakage to be subdominant to the statistical uncertainty. This is essential as we progress to higher detector counts in the next generation of CMB experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurement of the Isolated Nuclear Two-Photon Decay in Ge 72

The nuclear two-photon or double-gamma (2 γ ) decay is a second-order electromagnetic process whereby a nucleus in an excited state emits two gamma rays simultaneously. To be able to directly measure the 2⁢ γ decay rate in the low-energy regime below the electron-positron pair-creation threshold, we combined the isochronous mode of a storage ring with Schottky resonant cavities. The newly developed technique can be applied to isomers with excitation energies down to ~100 keV and half-lives as short as ~10 ms. The half-life for the 2⁢ γ decay of the first-excited 0 + state in bare 72 Ge ions was determined to be 23.9(6) ms, which strongly deviates from expectations.

59 ≤ A ≤ 89↗

On-Sky Performance of the SPT-3G Frequency-Domain Multiplexed Readout

Frequency-domain multiplexing (fMux) is an established technique for the readout of large arrays of transition-edge sensor (TES) bolometers. Each TES in a multiplexing module has a unique AC voltage bias that is selected by a resonant filter. This scheme provides for the operation and readout of multiple bolometers on a single pair of wires, reducing thermal loading onto sub-Kelvin stages. The current receiver on the South Pole Telescope, SPT-3G, uses a 68x fMux system to operate its large-format camera of ~16,000 TES bolometers. We present here the successful implementation and performance of the SPT-3G readout as measured on-sky. Characterization of the noise reveals a median pair-differenced 1/f knee frequency of 33 mHz, indicating that low-frequency noise in the readout will not limit SPT-3G’s measurements of sky power on large angular scales. Measurements further show that the median readout white noise level in each of the SPT-3G observing bands is below the expectation for photon noise, demonstrating that SPT-3G is operating in the photon-noise-dominated regime.

47 OTHER INSTRUMENTATION↗

Optical Design and Characterization of 40-GHz Detector and Module for the BICEP Array

Families of cosmic inflation models predict a primordial gravitational-wave background that imprints B-mode polarization pattern in the cosmic microwave background (CMB). High-sensitivity instruments with wide frequency coverage and well-controlled systematic errors are needed to constrain the faint B-mode amplitude. We have developed antenna-coupled transition edge sensor arrays for high-sensitivity polarized CMB observations over a wide range of millimeter-wave bands. BICEP array, the latest phase of the BICEP/Keck experiment series, is a multi-receiver experiment designed to search for inflationary B-mode polarization to a precision σ(r) between 0.002 and 0.004 after 3 full years of observations, depending on foreground complexity and the degree of lensing removal. We describe the electromagnetic design and measured performance of BICEP array’s low-frequency 40-GHz detector, their packaging in focal plane modules, and optical characterization including efficiency and beam matching between polarization pairs. We summarize the design and simulated optical performance, including an approach to improve the optical efficiency due to mismatch losses. Here, we report the measured beam maps for a new broadband corrugation design to minimize beam differential ellipticity between polarization pairs caused by interactions with the module housing frame, which helps minimize polarized beam mismatch that converts CMB temperature to polarization (T→P) anisotropy in CMB maps.

47 OTHER INSTRUMENTATION↗

Design and Performance of the First BICEP Array Receiver

Branches of cosmic inflationary models, such as slow-roll inflation, predict a background of primordial gravitational waves that imprints a unique odd-parity “B-mode” pattern in the Cosmic Microwave Background (CMB) at amplitudes that are within experimental reach. The BICEP/Keck (BK) experiment targets this primordial signature, the amplitude of which is parameterized by the tensor-to-scalar ratio r, by observing the polarized microwave sky through the exceptionally clean and stable atmosphere at the South Pole. B-mode measurements require an instrument with exquisite sensitivity, tight control of systematics, and wide frequency coverage to disentangle the primordial signal from the Galactic foregrounds. BICEP Array represents the most recent stage of the BK program and comprises four BICEP3-class receivers observing at 30/40, 95, 150 and 220/270 GHz. The 30/40 GHz receiver will be deployed at the South Pole during the 2019/2020 austral summer. After 3 full years of observations with 30,000+ detectors, BICEP Array will measure primordial gravitational waves to a precision σ(r) between 0.002 and 0.004, depending on foreground complexity and the degree of lensing removal. Here in this paper, we give an overview of the instrument, highlighting the design features in terms of cryogenics, magnetic shielding, detectors and readout architecture as well as reporting on the integration and tests that are ongoing with the first receiver at 30/40 GHz.

79 ASTRONOMY AND ASTROPHYSICS↗

Searching for the origin of the rare-earth peak with precision mass measurements across Ce–Eu isotopic chains

A nuclear mass survey of rare-earth isotopes has been conducted with the Canadian Penning Trap mass spectrometer using the most neutron-rich nuclei thus far extracted from the CARIBU facility. Here, we present a collection of 12 nuclear masses determined with a precision of ≤ 10 keV/c 2 for Z = 58-63 nuclei near N = 100. Independently, a detailed study exploring the role of nuclear masses in the formation of the r-process rare-earth abundance peak has been performed. Employing a Markov chain Monte Carlo (MCMC) technique, mass predictions of lanthanide isotopes have been made which uniquely reproduce the observed solar abundances near A = 164 under three distinct astrophysical outflow conditions. We demonstrate that the mass surface trends thus far mapped out by our measurements are most consistent with MCMC mass predictions given an r process that forms the rare-earth peak during an extended (n, γ) ⇌ (γ, n) equilibrium.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thermodynamic stability of xenon-doped liquid argon detectors

Liquid argon detectors are employed in a wide variety of nuclear and particle physics experiments. The addition of small quantities of xenon to argon modifies its scintillation, ionization, and electroluminescence properties and can improve its performance as a detection medium. However, a liquid argon-xenon mixture can develop instabilities, especially in systems that require phase transitions or that utilize high xenon concentrations. In this work, we analyze the causes of these instabilities and describe a small (liter-scale) apparatus with a unique cryogenic circuit specifically designed to handle argon-xenon mixtures. The system is capable of condensing argon gas mixed with $\mathscr{O}$ (1%) xenon by volume and maintains a stable liquid mixture near the xenon saturation limit while actively circulating it in the gas phase. We also demonstrate control over instabilities that develop when the detector condition is allowed to deviate from optimized settings. This progress enables future liquid argon detectors to benefit from the effects of high concentrations of xenon doping, such as more efficient detection of low-energy ionization signals. In conclusion, this work also develops tools to study and mitigate instabilities in large argon detectors that use low concentration xenon doping.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The DESI Survey Validation: Results from Visual Inspection of Bright Galaxies, Luminous Red Galaxies, and Emission-line Galaxies

The Dark Energy Spectroscopic Instrument (DESI) Survey has obtained a set of spectroscopic measurements of galaxies to validate the final survey design and target selections. To assist in these tasks, we visually inspect DESI spectra of approximately 2500 bright galaxies, 3500 luminous red galaxies (LRGs), and 10,000 emission-line galaxies (ELGs) to obtain robust redshift identifications. We then utilize the visually inspected redshift information to characterize the performance of the DESI operation. Based on the visual inspection (VI) catalogs, our results show that the final survey design yields samples of bright galaxies, LRGs, and ELGs with purity greater than 99%. Moreover, we demonstrate that the precision of the redshift measurements is approximately 10 km s –1 for bright galaxies and ELGs and approximately 40 km s –1 for LRGs. The average redshift accuracy is within 10 km s –1 for the three types of galaxies. The VI process also helps improve the quality of the DESI data by identifying spurious spectral features introduced by the pipeline. Finally, we show examples of unexpected real astronomical objects, such as Ly α emitters and strong lensing candidates, identified by VI. These results demonstrate the importance and utility of visually inspecting data from incoming and upcoming surveys, especially during their early operation phases.

79 ASTRONOMY AND ASTROPHYSICS↗

Enhancing physicochemical, bioactive, and nutritional properties of sweet potatoes: Ultrasonic contact drying with slot jet nozzles compared to hot-air drying and freeze drying

Sweet potatoes are a rich source of nutrients and bioactive compounds, but their quality can be impacted by the drying process. This study investigates the impact of slot jet reattachment (SJR) nozzle and ultrasound (US) combined drying (SJR + US) on sweet potato quality, compared to freeze-drying (FD), SJR drying, and hot air drying (HAD). SJR + US drying at 50 °C closely resembled FD in enhancing quality attributes and outperformed HAD and SJR in key areas such as rehydration, shrinkage ratios, and nutritional composition. Notably, SJR + US at 50 °C produced the highest total starch (36.84 g/100 g), total dietary fiber (8.48 g/100 g), total phenolic content (158.19 mg GAE/100 g), total flavonoid content (119.08 mg QE/g), DPPH antioxidant activity (6.44 μmol TE/g), β-carotene (31.98 mg/100 g), and vitamin C (5.27 mg/100 g). It also exhibited higher glass transition temperatures (Tg: 14.49 °C), indicating better stability at room temperature. The hardness values for SJR + US samples were similar to FD, while HAD samples had the highest hardness. SJR + US at 50 °C resulted in the lowest total color changes (ΔE), indicating minimal impact on appearance. Additionally, FTIR analysis revealed that peaks in specific spectral regions indicated superior preservation of bioactive compounds in SJR + US samples compared to other methods, which was also confirmed by principal component analysis (PCA) and heatmap visualization. Overall, these findings suggest that SJR + US is an effective alternative to conventional drying techniques, significantly improving the quality of dried sweet potatoes.

Color↗

First observation of isomeric states in 111 Zr, 113 Nb, and 115 Mo

Isomeric states in the neutron-rich nuclei 111 Zr [T 1/2 =0.10 (7) μs] , 113 Nb [T 1/2 =0.7 (4) μs], 115 Mo [T 1/2 =46 (3) μs] were first identified at the Radioactive Ion Beam Factory (RIBF) of RIKEN by using in-flight fission and fragmentation of a 238 U beam at an energy of 345 MeV/u. Here is a brief report of the γ transitions de-exciting from isomeric states and half-lives measurements, which provides the first spectroscopy in the nuclear region of prolate-to-oblate shape-phase transition around mass A ≈110.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Linear Viscoelastic Properties of Putative Cyclic Polymers Synthesized by Reversible Radical Recombination Polymerization (R3P)

Linear viscoelastic properties in both melt and solution states are reported for a series of poly(3,6-dioxa-1,8-octanedithiol) (polyDODT) made by reversible radical recombination polymerization (R 3 P) under conditions designed to produce linear (LDODT), cyclic (RDODT) and linear-cyclic mixtures (LRDODT). PolyDODT is amorphous (T g < -50 °C) and highly flexible (entanglement molecular weight M e,lin ≈ 1850 g/mol for LDODT). PolyDODT’s low T g and low M e,lin enable characterization over a wide dynamic range and a wide range of dimensionless weight-average molecular weight Z w = M w /M e,lin . Measurements at temperatures from -57 °C to 100 °C provide up to 18 deades of reduced frequency, which is necessary to characterize RDODT melts with Z w from 23 to 300. The two highest molecular weight polymers in the present RDODT series have such high M w (406k and 556k g/mol) that mass spectrometry, NMR spectroscopy, and even chemical assays for chain ends are unable to rule out up to 2 mol% linear contaminant. By studying the samples in solution (using dilution to reduce Z w ) we could compare their dynamics with those of previously established high-purity polystyrene (PS) rings (limited to Z w ≤ 13.6). RDODT solutions with Z w < 15 (concentrations <5wt% for RDODT-406k and 556k) have dynamic moduli G^* that accord with LCCC-purified PS rings in terms of the frequency dependence (including the absence of a plateau), the progression of shapes of G* as a function of Z w , and the linear scaling of their zero-shear viscosity η0 with M w . The shape of G* as a function of Z w for solutions of RDODT-406k and -556k also accord with lower M w RDODT melts (which have ≤ 1.3mol% linear contaminant). Thus, measurement of the linear viscoelastic properties of appropriate concentrations of high M w (>200k g/mol) putative cyclic polymers, in which linear chains evade spectroscopic detection, may provide an alternative means (though not fully proven) of validation of sample purity. When Z w > 15 (including all seven RDODT melts and eight of their solutions), G* has a rubbery plateau. This suggests that the onset of entanglement-like behavior in rings requires 4-5-fold greater Z w than is required for linear chains. Further, the plateau moduli of RDODT samples are indistinguishable from G N o of the corresponding LDODT (melt or matched-concentration solutions). In entangled linear polymers, the observation that G N o is independent of Z w follows from limitations on lateral fluctuations due to neighboring chains becoming independent of position along a given chain. The present results for RDODT suggest that this holds for sufficiently long endless chains, too. While the RDODT have the same G N o as entangled LDODT, when Z w > 60 the terminal relaxation, if reached at all, of RDODT extends to orders of magnitude lower frequency than an entangled linear polymer of the same Z w . Consequently, the viscosity of RDODT with Z w > 60 increases with Z w much more strongly than the 3.4-power observed for entangled linear polymers. Lastly, these novel polymers, with disulfide-linked backbone and broad relaxation time distribution may prove important in relation to biodegradable elastomers and materials with exceptional low-frequency dissipation, extending at least 12 decades below the onset of the rubbery plateau.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of a 83 mKr source for the calibration of the CENNS-10 liquid argon detector

We report on the preparation of and calibration measurements with a 83 mKr source for the CENNS-10 liquid argon detector. 83 mKr atoms generated in the decay of a 83 Rb source were introduced into the detector via injection into the Ar circulation loop. Scintillation light arising from the 9.4 keV and 32.1 keV conversion electrons in the decay of 83 mKr in the detector volume were then observed. This calibration source allows the characterization of the low-energy response of the CENNS-10 detector and is applicable to other low-energy-threshold detectors. The energy resolution of the detector was measured to be 9% at the total 83 mKr decay energy of 41.5 keV. Lastly, we performed an analysis to separately calibrate the detector using the two conversion electrons at 9.4 keV and 32.1 keV.

47 OTHER INSTRUMENTATION↗

Search for the semi-muonic charmonium decay J/ψ → D−μ+νμ + c.c.

Abstract Using (10087 ± 44) × 10 6 J/ψevents collected with the BESIII detector at the BEPCIIe + e − storage ring at the center-of-mass energy of$$ \sqrt{s} $$ s = 3.097 GeV, we present a search for the rare semi-muonic charmonium decayJ/ψ→D − μ + ν μ + c.c.. Since no significant signal is observed, we set an upper limit of the branching fraction to be$$ \mathcal{B} $$ B (J/ψ→D − μ + ν μ + c.c.) < 5.6 × 10 −7 at 90% confidence level. This is the first search for the weak decay of charmonium with a muon in the final state.

Physics↗