Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Freezing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

NMR study of Ni 50+x ⁢Ti 50-x strain glasses

Here, we studied Ni 50+x ⁢Ti 50-x with compositions up to x = 2, performing 47 Ti and 49 Ti nuclear magnetic resonance (NMR) measurements from 4 to 400 K. For large x in this system, a strain glass appears in which frozen ferroelastic nanodomains replace the displacive martensite structural transition. Here, we demonstrate that NMR can provide an extremely effective probe of the strain-glass freezing process, with large changes in NMR line shape due to the effects of random strains which become motionally narrowed at high temperatures. At the same time with high-resolution x-ray diffraction we confirm the lack of structural changes in x ≥ 1.2 samples, while we show that there is little change in the electronic behavior across the strain-glass freezing temperature. NMR spin-lattice relaxation time (T 1 ) measurements provide a further measure of the dynamics of the freezing process, and indicate a predominantly thermally activated behavior both above and below the strain-glass freezing temperature. We show that the strain-glass results are consistent with a very small density of critically divergent domains undergoing a Vogel-Fulcher-type freezing process, coexisting with domains exhibiting faster dynamics and stronger pinning.

36 MATERIALS SCIENCE↗

Vertical Structure and Ice Production Processes of Shallow Convective Postfrontal Clouds over the Southern Ocean in MARCUS. Part II: Modeling Study

Abstract Part I of this series presented a detailed overview of postfrontal mixed-phase clouds observed during the Measurements of Aerosols, Radiation, and Clouds over the Southern Ocean (MARCUS) field campaign. In Part II, we focus on a multiday (23–26 February 2018) case with the aim of understanding ice production as well as model sensitivity to ice process parameterizations using the Weather Research and Forecasting (WRF) Model. The control simulation with the Predicted Particle Properties (P3) microphysics scheme underestimates the ice content and overestimates the supercooled liquid water content, contrary to the bias common in global climate models. The simulations targeted at ice production processes show negligible sensitivity to cloud droplet number concentrations. Further, neither increasing ice nuclei particle (INP) concentrations to an unrealistic level nor adjusting it to MARCUS field estimations alone guarantees more ice production in the model. However, the simulated clouds are found to be highly sensitive to the implementation of immersion freezing, the thresholding of condensation/deposition freezing initiation, and the rime splintering process. By increasing immersion freezing of cloud droplets, relaxing thresholds for condensation/deposition freezing, or removing rime splintering thresholds, the model significantly improves its performance in producing ice. The relaxation of the immersion freezing temperature threshold to the observed cloud-top temperature suggests an in-cloud seeder–feeder mechanism. The results of this work call for an increase in observations of INP, especially over the remote Southern Ocean and at relatively high temperatures, and measurements of ice particle size distributions to better constrain ice nucleating processes in models.

Meteorology & Atmospheric Sciences↗

CACTI ARM Aerial Facility Measurements of Ice Nucleating Particles

The dataset comprises measures, using Colorado State University's Ice Spectrometer (IS, an immersion freezing device with a range from 0°C down to -26 to -29°C) of atmospheric ice nucleating particle (INP) concentrations taken on the Atmospheric Radiation Measurement (ARM) program Aerial Facilty (AAF) G-1 aircraft. INP measurements on the G-1 were collected from varied altitudes on different flights over the region of the Sierras de Córdoba mountain range of north-central Argentina, centred over ARM's Mobile Facility (AMF-1) near Villa Yacanto, where ground-based INP measures were being taken concurrently. Both studies took place as part of the Cloud, Aerosol, and Complex Terrain Interactions (CACTI) Experiment. A filter sampling system was deployed on the G-1 to collect aerosol particles for post-processing of INPs collected on filters (measuring their immersion freezing ability) once returned to Colorado State University (CSU). Filter holders used were pre-cleaned aluminum in-line units loaded with pre-cleaned and pre-sterilized 47 mm dia. Nuclepore polycarbonate filters (0.2 mm pore size). Filters were drawn for varied times, resulting in varied volumes collected (51 to 1667 SL). Mass flow rate was recorded in real-time so that total sampled volume (at standard temperature and pressure) could be determined. A total of 34 sample filters were collected over the IOP, including 5 blanks. Filters were stored at -20°C freezer prior to frozen return to Colorado State University (CSU). . Processing to obtain spectra of INP number concentration active via the immersion freezing mechanism versus temperature was conducted using CSU's IS instrument (McCluskey et al., 2018). For measurment of INPs, collected aerosol particles were re-suspended in 7 mL of 0.02 µm-filtered deionized water. Aliquots of each suspension, and serial dilutions, were dispensed into trays which were fit into aluminum blocks in the IS. Samples are cooled at 0.33°C min-1 and the freezing temperatures of wells recorded automatically. Cumulative INP concentrations were determined by first calculating the INPs per mL of suspension based on Vali (1971) and then converting to concentration per standard liter of air using the proportion of the total liquid sample dispensed and the air sample volumes. Aliquots of suspensions from selected samples were also heat treated (95°C for 20 min) to denature and deactivate biological INPs, and digested in 10% H2O2 at 95°C under UV-B to remove all organic carbon INPs. McCluskey, C. S., J. Ovadnevaite, M. Rinaldi, J. Atkinson, F. Belosi, D. Ceburnis, S. Marullo, T. C. J. Hill, U. Lohmann, Z. A. Kanji, C. O’Dowd, S. M. Kreidenweis, P. J. DeMott, 2018: Marine and Terrestrial Organic Ice Nucleating Particles in Pristine Marine to Continentally-Influenced Northeast Atlantic Air Masses, Journal of Geophysical Research: Atmospheres, 123, 6196–6212, https://doi.org/10.1029/2017JD028033. Vali, G., 1971: Quantitative evaluation of experimental results on the heterogeneous freezing nucleation of supercooled liquids. J. Atmos. Sci., 28, 402–409.

54 ENVIRONMENTAL SCIENCES↗

A 1D Model for Nucleation of Ice From Aerosol Particles: An Application to a Mixed‐Phase Arctic Stratus Cloud Layer

Abstract Mixed‐phase clouds (MPCs) have been identified as significant contributors to uncertainties in climate projections, attributable to model representation of processes controlling the formation and loss of supercooled water droplets and ice particles from the atmosphere. Arctic MPCs are commonly widespread and long‐lived, with sustained ice crystal formation processes that challenge current understanding. This study examines the ice‐nucleating particle (INP) reservoir dynamics governing immersion‐mode heterogeneous freezing in an observed case of Arctic MPCs using a simplified 1D aerosol‐cloud model. The model setup includes prescribed dynamical forcings and thermodynamic profiles, and represents INPs as multicomponent and polydisperse particle size distributions. Diagnostic and prognostic approaches to immersion freezing parameterization are compared, including time‐independent (singular) number‐ and surface area‐based descriptions and a time‐dependent description following classical nucleation theory (CNT). The choice of freezing parameterization defines the size of the INP reservoir. The CNT‐based description yields an orders of magnitude larger INP reservoir than the singular parameterizations, which is the dominant factor for sustained ice crystal formation. The efficiency of the freezing process and cloud cooling are of secondary importance. A diagnostic treatment neglecting INP loss is only accurate when the INP reservoir size is large and INP depletion weak. Since a larger INP reservoir sustains ice crystal formation substantially longer, and ice water path scales with ice crystal concentrations for the conditions considered, resolving the source of differences in INP reservoir dynamics due to model implementation is a high priority for advancing climate model physics.

54 ENVIRONMENTAL SCIENCES↗

Sterile neutrino dark matter and leptogenesis in Left-Right Higgs Parity

The standard model Higgs quartic coupling vanishes at (10 9 – 10 13 ) GeV. We study SU(2) L × SU(2) R × U(1) B–L theories that incorporate the Higgs Parity mechanism, where this becomes the scale of Left-Right symmetry breaking, $v_R$. Furthermore, these theories solve the strong CP problem and predict three right-handed neutrinos. We introduce cosmologies where SU(2) R × U(1) B–L gauge interactions produce right-handed neutrinos via the freeze-out or freeze-in mechanisms. In both cases, we find the parameter space where the lightest right-handed neutrino is dark matter and the decay of a heavier one creates the baryon asymmetry of the universe via leptogenesis. A theory of flavor is constructed that naturally accounts for the lightness and stability of the right-handed neutrino dark matter, while maintaining sufficient baryon asymmetry. The dark matter abundance and successful natural leptogenesis require vR to be in the range (10 10 – 10 13 ) GeV for freeze-out, in remarkable agreement with the scale where the Higgs quartic coupling vanishes, whereas freeze-in requires $v_R$ ≳ 109 GeV. The allowed parameter space can be probed by the warmness of dark matter, precise determinations of the top quark mass and QCD coupling by future colliders and lattice computations, and measurement of the neutrino mass hierarchy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Effect of isotropic and anisotropic porous microstructure on electrochemical performance of Li ion battery cathodes: An experimental and computational study

Liquid electrolyte mass transport is a major limitation affecting high-power Li ion batteries. Fast discharging causes Li salt depletion in the current collector region of the cathode which produces overpotential in the electrolyte and consequently a drop of cell voltage to below the cut-off voltage, especially at higher electrode thickness and discharge rate. In this study, through experiment and simulation, we have investigated the effect of electrode thickness, mass loading, discharge rate and tortuosity on electrolyte mass transport and final derived areal capacity and specific energy for electrodes having isotropic (normal tape casting) and anisotropic (freeze tape casting) porous microstructure. Furthermore, the macroporous channels in freeze tape cast electrodes facilitate Li salt transport and reduce the Li salt mass transport limitations even at high electrode thickness and discharge rates, and high electrode tortuosity. In our results, computer simulations show that freeze tape cast electrodes may be fully discharged up to 750 μm thickness at 1 C rate compared to 300 μm for normal tape cast electrodes with the same mass loading. Freeze tape cast electrodes also show stable maximum areal capacity for C rates about double the maximum C rates of their normal tape cast electrode counterparts with the same mass loading.

25 ENERGY STORAGE↗

Experimental Determination of the Relationship Between Organic Aerosol Viscosity and Ice Nucleation at Upper Free Tropospheric Conditions

Abstract This work presents measurements of the ice nucleating ability of secondary organic material recorded between −40 and −70°C and relative humidity with respect to ice (RH ice ) between 150% and 220%. For a subset of systems, temperature and humidity dependence of particle viscosity as well as dry glass transition temperature were characterized using the dual tandem differential mobility analyzer method. Eleven unique monoterpene, sesquiterpene and aromatic precursors were used to generate secondary organic material (SOM) using either an oxidation flow reactor (OFR) or an environmental chamber (EC). For the SOM for which viscosity was measured, the particle glass transition temperatures varied between 6 and 23°C ( n = 8). Measurements were performed to verify that increased relative humidity did not plasticize the particles below −10°C at residence times similar to those in the ice nucleation instrument. No heterogeneous ice nucleation was observed at the ∼0.5% onset threshold for any of the materials generated. The ice nucleation occurs by the freezing of SOM solution droplets consistent with homogeneous freezing indicating that they form an aqueous solution, or the SOM particles required water saturation to freeze, indicating that they were hydrophobic. Experiments exploring the influence of functional groups and mass loading did not reveal any obvious influence of particle chemistry or generation conditions on the results. Close structural matches between known organic ice nucleating particles as precursor or formed products did not yield materials that promoted freezing. These experiments suggest that heterogeneous ice formation of glassy secondary organic materials is likely uncommon under upper free tropospheric conditions.

54 ENVIRONMENTAL SCIENCES↗

The structural and functional integrities of porcine myocardium are mostly preserved by cryopreservation

Structural and functional studies of heart muscle are important to gain insights into the physiological bases of cardiac muscle contraction and the pathological bases of heart disease. While fresh muscle tissue works best for these kinds of studies, this is not always practical to obtain, especially for heart tissue from large animal models and humans. Conversely, tissue banks of frozen human hearts are available and could be a tremendous resource for translational research. It is not well understood, however, how liquid nitrogen freezing and cryostorage may impact the structural integrity of myocardium from large mammals. In this study, we directly compared the structural and functional integrity of never-frozen to previously frozen porcine myocardium to investigate the consequences of freezing and cryostorage. X-ray diffraction measurements from hydrated tissue under near-physiological conditions and electron microscope images from chemically fixed porcine myocardium showed that prior freezing has only minor effects on structural integrity of the muscle. Furthermore, mechanical studies similarly showed no significant differences in contractile capabilities of porcine myocardium with and without freezing and cryostorage. These results demonstrate that liquid nitrogen preservation is a practical approach for structural and functional studies of myocardium.

59 BASIC BIOLOGICAL SCIENCES↗

Time-resolved cryogenic electron tomography for the study of transient cellular processes

Cryogenic electron tomography (cryo-ET) is the highest resolution imaging technique applicable to the life sciences, enabling sub-nanometer visualization of specimens preserved in their near native states. The rapid plunge freezing process used to prepare samples lends itself to time-resolved studies, which researchers have pursued for in vitro samples for decades. Here, we focus on developing a freezing apparatus for time-resolved studies in situ. The device mixes cellular samples with solution-phase stimulants before spraying them directly onto an electron microscopy grid that is transiting into cryogenic liquid ethane. By varying the flow rates of cell and stimulant solutions within the device, we can control the reaction time from tens of milliseconds to over a second prior to freezing. In a proof-of-principle demonstration, the freezing method is applied to a model bacterium, Caulobacter crescentus, mixed with an acidic buffer. Through cryo-ET we resolved structural changes throughout the cell, including surface-layer protein dissolution, outer membrane deformation, and cytosolic rearrangement, all within 1.5 seconds of reaction time. This new approach, Time-Resolved cryo-ET (TR-cryo-ET), enhances the capabilities of cryo-ET by incorporating a sub-second temporal axis and enables the visualization of induced structural changes at the molecular, organelle, or cellular level.

59 BASIC BIOLOGICAL SCIENCES↗

Genotype-dependent contribution of CBF transcription factors to long-term acclimation to high light and cool temperature

When grown under cool temperature, winter annuals upregulate photosynthetic capacity as well as freezing tolerance. Here, the role of three cold-induced C-repeat-binding factor (CBF1–3) transcription factors in photosynthetic upregulation and freezing tolerance was examined in two Arabidopsis thaliana ecotypes originating from Italy (IT) or Sweden (SW), and their corresponding CBF1–3-deficient mutant lines it: cbf123 and sw: cbf123 . Photosynthetic, morphological and freezing-tolerance phenotypes, as well as gene expression profiles, were characterized in plants grown from the seedling stage under different combinations of light level and temperature. Under high light and cool (HLC) growth temperature, a greater role of CBF1–3 in IT versus SW was evident from both phenotypic and transcriptomic data, especially with respect to photosynthetic upregulation and freezing tolerance of whole plants. Overall, features of SW were consistent with a different approach to HLC acclimation than seen in IT, and an ability of SW to reach the new homeostasis through the involvement of transcriptional controls other than CBF1–3. These results provide tools and direction for further mechanistic analysis of the transcriptional control of approaches to cold acclimation suitable for either persistence through brief cold spells or for maximisation of productivity in environments with continuous low temperatures.

59 BASIC BIOLOGICAL SCIENCES↗

Comments on 'Do ultrafine cloud condensation nuclei invigorate deep convection?'

Here we elaborated on the deficiencies associated with the theoretical arguments and model simulations in Grawbowski and Morrison (2020; GM20), and showed that the concept of convective invigoration by aerosols can be supported by both accurate theoretical analysis and explicit physics modeling with prognostic aerosols and supersaturation. Above the freezing level, droplet freezing itself does not change mass loading and the latent heat release resulting from freezing leads to an increase in the buoyancy. The derivation in GM20 is erroneous because of omitting the liquid water sink term. They also ignored the effect of enhanced latent heating from the subsequent growth processes (deposition and riming) after freezing. Regarding aerosol effect on condensational growth, the quasi-steady assumption for supersaturation as adopted in GM20 is invalidated especially when droplet number concentration is low and updraft is strong from both theoretical analysis and our bin microphysics modeling results. The quasi-steady assumption makes condensation independent of droplet number and size and therefore reduces the overall aerosol effects on cloud dynamics. Studying aerosol effects on clouds particularly deep convective clouds requires the exact solution of supersaturation. Any assumption imposed to supersaturation such as saturation adjustment and quasi-steady approximation leads to incorrect aerosol effects on diffusional growth. The exact supersaturation equation clearly shows that condensation depends on droplet number and size, and more droplets in the polluted clouds increase condensation (thus lower supersaturation), leading to enhanced buoyancy and updraft speeds.

Convective invigoration, deep convective clouds, a↗

A Method to Preserve Wetland Roots and Rhizospheres for Elemental Imaging

Roots extensively interact with their soil environment but visualizing such interactions between roots and the surrounding rhizosphere is challenging. The rhizosphere chemistry of wetland plants is particularly challenging to capture because of steep oxygen gradients from the roots to the bulk soil. Here a protocol is described that effectively preserves root structure and rhizosphere chemistry of wetland plants through slam-freezing and freeze drying. Slam-freezing, where the sample is frozen between copper blocks pre-cooled with liquid nitrogen, minimizes root damage and sample distortion that can occur with flash-freezing while still minimizing chemical speciation changes. While sample distortion is still possible, the ability to obtain multiple samples quickly and with minimal cost increases the potential to obtain satisfactory samples and optimizes imaging time. The data show that this method is successful in preserving reduced arsenic species in rice roots and rhizospheres associated with iron plaques. This method can be adopted for studies of plant-soil relationships in a wide variety of wetland environments that span concentration ranges from trace-element cycling to phytoremediation applications.

59 BASIC BIOLOGICAL SCIENCES↗

Field intercomparison of ice nucleation measurements: the Fifth International Workshop on Ice Nucleation Phase 3 (FIN-03)

Abstract. The third phase of the Fifth International Ice Nucleation Workshop (FIN-03) was conducted at the Storm Peak Laboratory in Steamboat Springs, Colorado, in September 2015 to facilitate the intercomparison of instruments measuring ice-nucleating particles (INPs) in the field. Instruments included two online and four offline measurement systems for INPs, which are a subset of those utilized in the laboratory study that comprised the second phase of FIN (FIN-02). The composition of the total aerosols was characterized using the Particle Analysis by Laser Mass Spectrometry (PALMS) and Wideband Integrated Bioaerosol Sensor (WIBS) instruments, and aerosol size distributions were measured by a laser aerosol spectrometer (LAS). The dominant total particle compositions present during FIN-03 were composed of sulfates, organic compounds, and nitrates, as well as particles derived from biomass burning. Mineral-dust-containing particles were ubiquitous throughout and represented 67 % of supermicron particles. Total WIBS fluorescing particle concentrations for particles with diameters of > 0.5 µm were 0.04 ± 0.02 cm−3 (0.1 cm−3 highest; 0.02 cm−3 lowest), typical of the warm season in this region and representing ≈ 9 % of all particles in this size range as a campaign average. The primary focus of FIN-03 was the measurement of INP concentrations via immersion freezing at temperatures > −33 °C. Additionally, some measurements were made in the deposition nucleation regime at these same temperatures, representing one of the first efforts to include both mechanisms within a field campaign. INP concentrations via immersion freezing agreed within factors ranging from nearly 1 to 5 times on average between matched (time and temperature) measurements, and disagreements only rarely exceeded 1 order of magnitude for sampling times coordinated to within 3 h. Comparisons were restricted to temperatures lower than −15 °C due to the limits of detection related to sample volumes and very low INP concentrations. Outliers of up to 2 orders of magnitude occurred between −25 and −18 °C; a better agreement was seen at higher and lower temperatures. Although the 5–10 factor agreement of INP measurements found in FIN-03 aligned with the results of the FIN-02 laboratory comparison phase, giving confidence in progress of this measurement field, this level of agreement still equates to temperature uncertainties of 3.5 to 5 °C that may not be sufficient for numerical cloud modeling applications that utilize INP information. INP activity in the immersion-freezing mode was generally found to be an order of magnitude or more, making it more efficient than in the deposition regime at 95 %–99 % water relative humidity, although this limited data set should be augmented in future efforts. To contextualize the study results, an assessment was made of the composition of INPs during the late-summer to early-fall period of this study inferred through comparison to existing ice nucleation parameterizations and through measurement of the influence of thermal and organic carbon digestion treatments on immersion-freezing ice nucleation activity. Consistent with other studies in continental regions, biological INPs dominated at temperatures of > −20 °C and sometimes colder, while arable dust-like or other organic-influenced INPs were inferred to dominate below −20 °C.

54 ENVIRONMENTAL SCIENCES↗

Inclusion of a cold hardening scheme to represent frost tolerance is essential to model realistic plant hydraulics in the Arctic–boreal zone in CLM5.0-FATES-Hydro

As temperatures decrease in autumn, vegetation of temperate and boreal ecosystems increases its tolerance to freezing. This process, known as hardening, results in a set of physiological changes at the molecular level that initiate modifications of cell membrane composition and the synthesis of anti-freeze proteins. Together with the freezing of extracellular water, anti-freeze proteins reduce plant water potentials and xylem conductivity. To represent the responses of vegetation to climate change, land surface schemes increasingly employ “hydrodynamic” models that represent the explicit fluxes of water from soil and through plants. The functioning of such schemes under frozen soil conditions, however, is poorly understood. Nonetheless, hydraulic processes are of major importance in the dynamics of these systems, which can suffer from, e.g., winter “frost drought” events. In this study, we implement a scheme that represents hardening into CLM5.0-FATES-Hydro. FATES-Hydro is a plant hydrodynamics module in FATES, a cohort model of vegetation physiology, growth, and dynamics hosted in CLM5.0. We find that, in frozen systems, it is necessary to introduce reductions in plant water loss associated with hardening to prevent winter desiccation. This work makes it possible to use CLM5.0-FATES-Hydro to model realistic impacts from frost droughts on vegetation growth and photosynthesis, leading to more reliable projections of how northern ecosystems respond to climate change.

58 GEOSCIENCES↗

Annual carbon dioxide flux over seasonal sea ice in the Canadian Arctic

Continuous measurements of carbon dioxide (CO 2 ) flux were collected from a 10 m eddy covariance tower in a coastal-marine environment in the Canadian Arctic Archipelago over the course of a 17-month period. The extended length of data collection resulted in a unique dataset that includes measurements from two spring melt and summer seasons and one autumn freeze-up. These field observations were used to verify findings from previous theoretical and laboratory experiments investigating air-sea gas exchange in connection with sea ice. The results corroborated previous findings showing that thick ice cover under winter conditions acts as a barrier to gas exchange. In the spring, CO 2 fluxes were downward (uptake) in both the presence of melt ponds and during ice break-up. However, diurnal cycles were present throughout the early spring melt period, corresponding to the opposing influences of freezing and melting at the ice surface. Fluxes measured during melt periods confirmed previous laboratory tank measurements that showed a gas transfer coefficient of melting ice of 0.4 mol m −2 d −1 atm −1 . Open water CO 2 fluxes showed outgassing in early summer and uptake in mid-to-late summer, tied closely to trends in surface water temperature and its effect on the partial pressure of CO 2 in the water. The autumn period of the field campaign represents the first eddy covariance CO 2 fluxes measured over naturally forming sea ice. Our measurements showed mean upward fluxes (outgassing) of 1.1±1.5 mmol m −2 d −1 associated with the freezing of ice – the same order of magnitude found by previous laboratory tank experiments. However, peak flux periods during ice formation had measured fluxes that were a factor of 3 higher than the tank experiments, suggesting the importance of natural conditions (e.g., wind) on air-ice gas exchange. Conducting an Arctic-wide extrapolation we estimate CO 2 outgassing from the freezing period to be a counterbalance equivalent to 5 to 15 % of the magnitude of the estimated Arctic CO 2 sink. Overall, there was no evidence of dramatically enhanced gas exchange in marginal ice conditions as proposed by previous studies. Although the different seasons showed active CO 2 exchange, there was a balance between upward and downward fluxes at this specific location, resulting in a small net CO 2 uptake over the annual cycle of −0.3 g C m −2 .

54 ENVIRONMENTAL SCIENCES↗

CACTI ARM Mobile Facility (AMF) Measurements of Ice Nucleating Particles

The dataset comprises measures, using Colorado State University's Ice Spectrometer (IS, an immersion freezing device with a range from 0°C down to -26 to -29°C) of atmosperic ice nucleating particle (INP) concentrations taken on ARM's Mobile Facility (AMF-1) Aerosol Observing System, near Villa Yacanto in central Argentina, during the Cloud, Aerosol, and Complex Terrain Interactions (CACTI) Experiment. A filter sampler was mounted on the AOS trailer (2 m below the AOS inlet). Single-use filter units open to the atmosphere fitted with pre-cleaned and pre-sterilized, 47-mm dia. Nuclepore polycarbonate filters were used. Filters were typically drawn for an 8-hour period, totaling 6000 liters sampled on average. After collection, filters were stored at -20°C until processed. Initial processing to obtain spectra of INP number concentration active via the immersion freezing mechanism versus temperature was conducted using CSU's IS instrument (McCluskey et al., 2018). For measurment of INPs, collected aerosol particles were re-suspended in 7-8 mL of 0.1 µm-filtered deionized (DI) water. Aliquots of each suspension, and serial dilutions, were dispensed into trays which were fit into aluminum blocks in the IS. Samples are cooled at 0.33°C min-1 and the freezing temperatures of wells recorded automatically. Cumulative INP concentrations were determined by first calculating the INPs per mL of suspension based on Vali (1971) and then converting to concentration per standard liter of air using the proportion of the total liquid sample dispensed and the air sample volumes. An aliquot of suspension fro selected samples were also heat treated (95°C for 20 min) to denature and deactivate biological INPs, and another aliquot digested in 10% H2O2 at 95°C under UV-B to remove all organic carbon INPs. McCluskey, C. S., J. Ovadnevaite, M. Rinaldi, J. Atkinson, F. Belosi, D. Ceburnis, S. Marullo, T. C. J. Hill, U. Lohmann, Z. A. Kanji, C. O’Dowd, S. M. Kreidenweis, P. J. DeMott, 2018: Marine and Terrestrial Organic Ice Nucleating Particles in Pristine Marine to Continentally-Influenced Northeast Atlantic Air Masses, Journal of Geophysical Research: Atmospheres, 123, 6196–6212, https://doi.org/10.1029/2017JD028033. Vali, G., 1971: Quantitative evaluation of experimental results on the heterogeneous freezing nucleation of supercooled liquids. J. Atmos. Sci., 28, 402–409.

54 ENVIRONMENTAL SCIENCES↗

Data center coolant switch

A data center cooling system has an indoor portion wherein heat is absorbed from components in the data center, and an outdoor heat exchanger portion wherein outside air is used to cool a first heat transfer fluid (e.g., water) present in at least the outdoor heat exchanger portion of the cooling system during a first mode. When an appropriate time has been reached to switch from the first mode to a second mode, the outdoor heat exchanger portion of the data cooling system is switched to a second heat transfer fluid, which is a relatively low performance heat transfer fluid (compared to the first fluid). It has a second heat transfer fluid freezing point, lower than the first heat transfer fluid freezing point, and sufficiently low to operate without freezing when the outdoor air temperature drops below a first predetermined relationship with the first heat transfer fluid freezing point.

Iyengar, Madhusudan Krishnan↗

Data center coolant switch

A data center cooling system has an indoor portion wherein heat is absorbed from components in the data center, and an outdoor heat exchanger portion wherein outside air is used to cool a first heat transfer fluid (e.g., water) present in at least the outdoor heat exchanger portion of the cooling system during a first mode. When an appropriate time has been reached to switch from the first mode to a second mode, the outdoor heat exchanger portion of the data cooling system is switched to a second heat transfer fluid, which is a relatively low performance heat transfer fluid (compared to the first fluid). It has a second heat transfer fluid freezing point, lower than the first heat transfer fluid freezing point, and sufficiently low to operate without freezing when the outdoor air temperature drops below a first predetermined relationship with the first heat transfer fluid freezing point.

Iyengar, Madhusudan K.↗