Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Flow loop”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

PLASMA MOTIONS AND HEATING BY MAGNETIC RECONNECTION IN A 2007 MAY 19 FLARE

Based on scanning spectroscopic observations with the Hinode EUV imaging spectrometer, we have found a loop-top hot source, a fast jet nearby, and an inflow structure flowing to the hot source that appeared in the impulsive phase of a long-duration flare at the disk center on 2007 May 19. The hot source observed in Fe XXIII and Fe XXIV emission lines has the electron temperature of 12 MK and density of 1 Multiplication-Sign 10{sup 10} cm{sup -3}. It shows excess line broadening, which exceeds the thermal Doppler width by {approx}100 km s{sup -1}, with a weak redshift of {approx}30 km s{sup -1}. We have also observed a blueshifted faint jet whose Doppler velocity exceeds 200 km s{sup -1} with an electron temperature of 9 MK. Coronal plasmas with electron temperature of 1.2 MK and density of 2.5 Multiplication-Sign 10{sup 9} cm{sup -3} that flow into the loop-top region with a Doppler velocity of 20 km s{sup -1} have been identified in the Fe XII observation. They disappeared near the hot source, possibly by being heated to the hotter faint jet temperature. From the geometrical relationships of these phenomena, we conclude that they provide evidence for magnetic reconnection that occurs near the loop-top region. The estimated reconnection rate is 0.05-0.1, which supports the Petschek-type magnetic reconnection. Further supporting evidence for the presence of the slow-mode and fast-mode MHD shocks in the reconnection geometry is given based on the observed quantities.

79 ASTRONOMY AND ASTROPHYSICS↗

Orientation of the intra-unit-cell magnetic moment in the high- T c superconductor HgBa 2 CuO 4+δ

Polarized-neutron diffraction (PND) experiments have revealed that the pseudogap state of the cuprates exhibits unusual intra-unit-cell (IUC) magnetism. At a qualitative level, the data indicate a moment direction that is neither perpendicular nor parallel to the CuO 2 layers, yet an accurate measurement at a high-symmetry momentum point in a structurally simple compound has been lacking. Such a measurement would be crucial, as it would help to narrow down the scenarios for the microscopic origin of the IUC magnetism. Here we report PND results with unprecedented accuracy for the IUC magnetic order in the simple-tetragonal single-CuO 2 -layer compound HgBa 2 CuO 4+δ . At the pseudogap temperature, we find evidence for magnetic critical scattering. Deep in the ordered state, we determine the moment direction to be 70° ± 10° away from the normal to the CuO 2 layers, which rules out both purely planar loop currents and high-symmetry Dirac multipoles, the two most prominent theoretical proposals for the microscopic origin of the IUC magnetism. Furthermore, the data are consistent with Dirac multipoles of lower symmetry or, alternatively, with a particular configuration of loop currents that flow on the faces of the CuO 6 octahedra.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Towards Generalizable and Efficient Circuit Topology Design: A Graph-Transformer-based Surrogate Model with Curriculum Learning

Unlike circuit parameter and sizing optimizations, the automated design of analog circuit topologies poses significant challenges for learning-based approaches. One challenge arises from the combinatorial growth of the topology space with circuit size, which limits the topology optimization efficiency. Moreover, traditional circuit evaluation methods are time-consuming, while the presence of data discontinuity in the topology space makes the accurate prediction of circuit performance exceptionally difficult for unseen topologies. To tackle these challenges, we design a novel Graph-Transformer-based Network (GTN) as the surrogate model for circuit evaluation, offering a substantial acceleration in the speed of circuit topology optimization without sacrificing performance. Our GTN model architecture is designed to embed voltage changes in circuit loops and current flows in connected devices, enabling accurate performance predictions for circuits with unseen topologies. To address the cold start problem when scaling GTN to large-scale circuits, we further introduce a curriculum learning strategy that progressively trains GTN from small-scale to large-scale circuits. This approach enables the model to first learn fundamental physical principles from simpler topologies and gradually adapt to complex configurations, effectively bridging the circuit complexity gap and improving prediction accuracy. Taking the power converter circuit design as an experimental task, our GTN model significantly outperforms an analytical approach and baseline methods directly utilizing graph neural networks. Furthermore, GTN achieves less than 5% relative error and 196× speed-up compared with high-fidelity simulation. Notably, our GTN surrogate model empowers an automatic circuit design framework to discover circuits of comparable quality to those identified through high-fidelity simulation while reducing the time required by up to 98.2%. With curriculum learning, the enhanced GTN achieves a 51% improvement for performance prediction of large-scale circuits compared to the GTN model without this strategy. These advancements establish GTN as a scalable framework for automated analog circuit design across varying circuit complexity levels.

Lu, Haoshu [New Jersey Institute of Technology (NJ↗

Active Magnetic Regenerative Liquefier

This final report for the DOE Project entitled Active Magnetic Regenerative Liquefier (AMRL) funded under Grant DE-FG36-08GO18064 to Heracles Energy Corporation d.b.a. Prometheus Energy (Heracles/Prometheus) describes an active magnetic regenerative refrigerator (AMRR) prototype designed and built during the period from July 2008 through May 2011. The primary goal of this project was to make significant technical advances toward highly efficient liquefaction of hydrogen. Conventional hydrogen liquefiers at any scale have a maximum FOM of ~0.35 due primarily to the intrinsic difficulty of rapid, efficient compression of either hydrogen or helium working gases. Numerical simulation modeling of high performance AMRL designs indicates certain designs have promise to increase thermodynamic efficiency from a FOM of ~0.35 toward ~0.5 to ~0.6. The technical approach was the use of solid magnetic working refrigerants cycled in and out of high magnetic fields to build an efficient active regenerative magnetic refrigeration module providing cooling power for AMRL. A single-stage reciprocating AMRR with a design temperature span from ~290 K to ~120 K was built and tested with dual magnetic regenerators moving in and out of the conductively-cooled superconducting magnet subsystem. The heat transfer fluid (helium) was coupled to the process stream (refrigeration/liquefaction load) via high performance heat exchangers. In order to maximize AMRR efficiency a helium bypass loop with adjustable flow was incorporated in the design because the thermal mass of magnetic refrigerants is higher in low magnetic field than in high magnetic field. Heracles/Prometheus designed experiments to measure AMRR performance under a variety of different operational parameters such as cycle frequency, magnetic field strength, heat transfer fluid flow rate, amount of bypass flow of the heat transfer fluid while measuring work input, temperature span, cooling capability as a function of cold temperature as a function of the amount of bypass flow of the heat transfer fluid. The operational AMRR prototype can be used to answer key questions such as the best recipe for multiple layers of different magnetic refrigerants in one or more integrated regenerators with varying amounts of bypass flow of the heat transfer fluid. Layered regenerators are necessary to span the AMRR range from 290 K to 120K. Our AMRR performance simulation model predicts that ~10-15 % of bypass flow should significantly improve the thermodynamic performance. Initial results obtained with regenerators made of gadolinium spheres were very encouraging; a temperature span of ~ 50 K (between 295K and 245 K) across both regenerators was achieved with zero bypass flow of the heat transfer fluid and with the magnetic field strength of ~4 T.

42 ENGINEERING↗

RELAP5-3D Assessment Using High Temperature Test Facility Test PG-22

The RELAP5-3D computer code has been assessed using data from Test PG 22 in Oregon State University’s High Temperature Test Facility. Test PG 22 investigated the gas exchange between the primary coolant system helium and the reactor cavity simulation tank nitrogen following a heatup from ambient temperature. The heatup was terminated when the coolant temperature rise across the core reached 125°C. The code generally under predicted coolant and structure temperatures, likely the result of under predicting the core temperature and stored energy during the initial heatup, although there were no measured values to compare with. A full-loop natural circulation flow that occurred in the test was not predicted in any of the simulations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Directly connected heat exchanger tube section and coolant-cooled structure

A cooling apparatus for an electronics rack is provided which includes an air-to-liquid heat exchanger, one or more coolant-cooled structures and a tube. The heat exchanger, which is associated with the electronics rack and disposed to cool air passing through the rack, includes a plurality of distinct, coolant-carrying tube sections, each tube section having a coolant inlet and a coolant outlet, one of which is coupled in fluid communication with a coolant loop to facilitate flow of coolant through the tube section. The coolant-cooled structure(s) is in thermal contact with an electronic component(s) of the rack, and facilitates transfer of heat from the component(s) to the coolant. The tube connects in fluid communication one coolant-cooled structure and the other of the coolant inlet or outlet of the one tube section, and facilitates flow of coolant directly between that coolant-carrying tube section of the heat exchanger and the coolant-cooled structure.

42 ENGINEERING↗

Directly connected heat exchanger tube section and coolant-cooled structure

A method is provided for fabricating a cooling apparatus for cooling an electronics rack, which includes an air-to-liquid heat exchanger, one or more coolant-cooled structures, and a tube. The heat exchanger is associated with the electronics rack and disposed to cool air passing through the rack, includes a plurality of coolant-carrying tube sections, each tube section having a coolant inlet and outlet, one of which is coupled in fluid communication with a coolant loop to facilitate flow of coolant through the tube section. The coolant-cooled structure(s) is in thermal contact with an electronic component(s) of the rack, and facilitates transfer of heat from the component(s) to the coolant. The tube connects in fluid communication one coolant-cooled structure and the other of the coolant inlet or outlet of the one tube section, and facilitates flow of coolant directly between that coolant-carrying tube section of the heat exchanger and the coolant-cooled structure.

42 ENGINEERING↗

Magnetic Flux Generated by Thermal Current in CEBAF 5-Cell Cavity System

The unloaded quality factor Q0 of many 5-cell CEBAF cavities were lowered by a factor of ~2 from their vertical qualification testing to their beam operation in CEBAF tunnel. Causes of this Q0 degradation were studied previously, including a more recent one addressing static fluxes arising from magnetic components near a 5-cell cavity. This paper reports on a preliminary study of the dynamic fluxes generated by a thermal current. Such a thermal current arises from the Seebeck effect and flows in closed loops formed by a niobium cavity and its surrounding tuner rods and liquid helium vessel that are made of stainless-steel. The behaviors of magnetic fluxes in response to various thermal profiles on a 5-cell CEBAF cavity with integrated tuner rods were studied in a JLAB VTA dewar. An outcome of this study is a proposed cool-down procedure for eliminating the thermal current generated magnetic fluxes around 5-cell cavities placed in CEBAF tunnels. This procedure may be useful to improve cavity Q0 in a cost-effective manner, which in turn saves cryogenic expenditures for sustaining CEBAF operation.

Geng, Rongli↗

BETO 2021 Peer Review - Continuous Enzymatic Hydrolysis Development (CEHD) WBS 2.4.1.101

The Continuous Enzymatic Hydrolysis Development (CEHD) project aims to reduce the cost and commercialization scale-up risks of biorefinery sugar-lignin production through development of a deployable continuous enzymatic hydrolysis (CEH) process. Through the use of external cross flow membrane filtration loops coupled to enzymatic hydrolysis (EH) reactors, pretreated biomass solids and enzymes are retained for reaction while solubilized product sugars are removed in situ, with high extents of conversion achieved through a series of reactor-membrane unit stages. The CEHD project is focused on advancing CEH as a transformational, process-intensified, lower-cost method for producing soluble clarified biomass sugars and insoluble lignin-rich streams than traditional batch enzymatic hydrolysis (BEH). The project's primary objective is to reduce the cost of CEH to be compellingly lower than conventional BEH, 10% lower in year 1 and 20% lower in year 3 (end of project). A related objective is to expand CEH's operating envelope to increase process efficiency. Through more thorough de-risking and demonstration of CEH, in conjunction with building a suite of modeling and optimization tools that allow for more facile rigorous in silico evaluation of novel CEH designs and modalities, this project intends to elevate industry interest in adopting CEH as an improvement over conventional batch processing. This project was merit reviewed in FY20. It's now in its first year of a new 3-year plan spanning FY21-FY23.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Scaling-based Applicability Assessment of the CAER Integrated Systems Test Facility

This paper presents a scaling-based applicability assessment of the Integrated Systems Test (IST) facility located at the Center of Advanced Engineering Research in Forest, Virginia. The assessment draws upon both traditional and contemporary scaling methods, seeking an optimal representation of light water reactor (LWR) and small modular reactor (SMR) characteristics during design-basis events. Based on published LWR loss-of-coolant-accident phenomena identification and ranking tables compiled with a similar assessment completed by BWXT mPower, Inc., for the mPower{sup TM} SMR, the phenomena considered in the IST design include break flow, decay heat, loop thermal-hydraulics, and primary-to-secondary heat transfer. Among these, the single- and two-phase natural circulation and system depressurization, by association to loop thermal-hydraulics, were the principal challenges. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Compatibility of an FeCrAl alloy with flowing Pb-Li in a thermal convection loop

A mono-metallic thermal convection loop (TCL) fabricated from alloy APMT (Fe21Cr5Al3Mo) tubing and filled with 0.025 m long tensile specimens of the same alloy was operated continuously for 1000 h with commercially pure Pb-17 at.%Li (Pb-Li) at a peak temperature of 550 ± 1.5 °C and a temperature gradient of ~116 °C. The resulting Pb-Li flow rate was ~0.0067 m/s. A 1050 °C pre-oxidation treatment (to form an external alumina scale) given to most specimens exposed within the TCL decreased total mass loss by a factor of 3–30 compared to adjacent specimens that were not pre-oxidized. However, all specimens exposed above 500 °C lost mass suggesting that the alumina scale was not entirely stable in flowing Pb-Li at these temperatures. Post-exposure room temperature tensile tests indicated that the mechanical properties of APMT were substantially influenced by extended exposures in the range of 435–490 °C, which caused an increase in yield strength (~65%) and a corresponding decrease in ductility associated with α' embrittlement. Specimens annealed in argon at the same temperature exhibited identical changes without exposure to Pb-Li. In conclusion, scanning transmission electron microscopy revealed Cr-clusters within the microstructure in specimens exposed in the low temperature regions (<490 °C) of the TCL, indicating the formation of α' consistent with the mechanism of α' embrittlement.

36 MATERIALS SCIENCE↗

Catalytic resonance theory: Circumfluence of programmable catalytic loops

Chemical reactions on heterogeneous catalyst surfaces exhibit complex networks of elementary reactions with multiple pathways to fluid phase products, sometimes leading to surface reaction loops consisting of a closed cycle reaction pathway. While conventional catalysts at steady state exhibit zero net flux in either direction around a catalytic loop, the loop turnover frequency of three-species surface loops was evaluated in this work via microkinetic modeling to assess the reaction loop behavior resulting from a catalytic surface oscillating between two or more surface energy states. For dynamic heterogeneous catalysts undergoing applied oscillations of surface energy (i.e., programs), surface reaction loops of three species were shown to exhibit non-zero net flow of molecules around the loop, with the extent of loop turnover frequency varying with the applied frequency and amplitude of a sinusoidal or square wave oscillation. Alternatively, some dynamic surface reactions exhibited oscillations only between two surface species or resulted in surfaces covered by a single species at all times. Here, more complex behavior was observed for dynamic surface programs of three distinct electronic states, with the temporal order of applied states controlling the direction of flow of molecules within a three-molecule surface loop. Catalytic loops have the potential to limit overall catalytic reaction rates and use energy in programmable catalysts, while some applications could purposely impose non-zero loop turnover frequency for improved surface reaction control.

Catalysis↗

Physics and the choice of regulators in functional renormalisation group flows

The Renormalisation Group is a versatile tool for the study of many systems where scale-dependent behaviour is important. Its functional formulation can be cast into the form of an exact flow equation for the scale-dependent effective action in the presence of an infrared regularisation. The functional RG flow for the scale-dependent effective action depends explicitly on the choice of regulator, while the physics does not. In this work, we systematically investigate three key aspects of how the regulator choice affects RG flows: (i) We study flow trajectories along closed loops in the space of action functionals varying both, the regulator scale and shape function. Such a flow does not vanish in the presence of truncations. Based on a definition of the length of an RG trajectory, we suggest a constructive procedure for devising optimised regularisation schemes within a truncation. (ii) In systems with various field variables, a choice of relative cutoff scales is required. At the example of relativistic bosonic two-field models, we study the impact of this choice as well as its truncation dependence. We show that a crossover between different universality classes can be induced and conclude that the relative cutoff scale has to be chosen carefully for a reliable description of a physical system. (iii) Non-relativistic continuum models of coupled fermionic and bosonic fields exhibit also dependencies on relative cutoff scales and regulator shapes. At the example of the Fermi polaron problem in three spatial dimensions, we illustrate such dependencies and show how they can be interpreted in physical terms. - Highlights: • We show the regulator dependence of functional renormalisation (FRG) group equations. • Solving FRG equations along closed loops provides a distance between two regulators. • We suggest a practical procedure for devising optimal regulators. • A universality class crossover can be induced by changing relative cutoff scales. • We examine the regulator dependence explicitly in the Fermi polaron problem.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Improved Application of Local Models to Steel Corrosion in Lead-Bismuth Loops

The corrosion of steels exposed to flowing liquid metals is influenced by local and global conditions of flow systems. The present study improves the previous local models when applied to closed loops by incorporating some global condition effects. In particular the bulk corrosion product concentration is calculated based on balancing the dissolution and precipitation in the entire closed loop. Mass transfer expressions developed in aqueous medium and an analytical expression are tested in the liquid-metal environments. The improved model is applied to a pure lead loop and produces results closer to the experimental data than the previous local models do. The model is also applied to a lead-bismuth eutectic (LBE) test loop. Systematic studies illustrate the effects of the flow rate, the oxygen concentration in LBE, and the temperature profile on the corrosion rate.

36 MATERIALS SCIENCE↗

Influence of extreme fracture flow channels on the thermal performance of open-loop geothermal systems at commercial scale

Abstract Adequate stewardship of geothermal resources requires accurate forecasting of long-term thermal performance. In enhanced geothermal systems and other fracture-dominated reservoirs, predictive models commonly assume constant-aperture fractures, although spatial variations in aperture can greatly affect reservoir permeability, fluid flow distribution, and heat transport. Whereas previous authors have investigated the effects of theoretical random aperture distributions on thermal performance, here we further explore the influence of permeability heterogeneity considering field-constrained aperture distributions from a meso-scale field site in northern New York, USA. Using numerical models of coupled fluid flow and heat transport, we conduct thermal–hydraulic simulations for a hypothetical reservoir consisting of a relatively impervious porous matrix and a single, horizontal fracture. Our results indicate that in highly channelized fields, most well design configurations and operating conditions result in extreme rates of thermal drawdown (e.g., 50% drop in production well temperatures in under 2 years). However, some other scenarios that account for the risks of short-circuiting can potentially enhance heat extraction when mass flow rate is not excessively high, and the direction of geothermal extraction is not aligned with the most permeable features in the reservoir. Through a parametric approach, we illustrate that well separation distance and relative positioning play a major role in the long-term performance of highly channelized fields, and both can be used to help mitigate premature thermal breakthrough.

Rangel-Jurado, Nicolás↗

An Experimental Reversed Heat Flux Investigation of the Helium-Cooled Modular Divertor with Multiple Jets

The Georgia Institute of Technology group has performed studies to characterize the thermal hydraulics of a single “finger” module of the helium-cooled modular divertor with multiple jets (HEMJ) proposed for long-pulse magnetic fusion reactors in a helium (He) loop designed with maximum mass flow rate of 10 g/s. However, testing divertor modules at prototypical heat fluxes and temperatures remains an engineering challenge. A new larger helium loop with a maximum mass flow rate of 100 g/s, suitable for evaluating helium-cooled divertors with larger surface areas such as a nine-finger HEMJ module, is currently being constructed. This work presents an experimental validation of a numerical model exploring the applicability of the “reversed heat flux approach,” which cools (versus heats) the plasma-facing surface of the divertor module to evaluate the helium-side heat transfer coefficient (HTC). The approach is to be used for performance evaluation of single and multiple modules of HEMJ in existing and future large helium loops. A cooling facility for producing a jet of water with a maximum mass flow rate of 1.4 kg/s at a maximum pressure of 0.4 MPa and temperature of 295 K (Re = 2.2 × 10 5 ) is described. Numerical and experimental results are presented for the heat flux and average helium impingement surface temperature over a range of water flow rates (0.5 to 1.4 kg/s) for heat fluxes as high as 5 MW/m 2 . The numerical model suggests that the HTC of the water impingement surface is comparable to or greater than that of the helium impingement surface. For given helium and water temperatures, the heat flux values are generally limited by conduction across the outer shell. These initial studies provide guidance on extending this approach to estimating the thermal-hydraulic performance of larger divertor module designs while reducing the challenges associated with studying such designs in the normal heating configuration at their extremely high prototypical temperatures and incident heat fluxes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

EXPERIMENTAL AND MODELLING ANALYSIS OF A LARGE-SCALE TWO-PHASE LOOP THERMOSYPHON

Liquid pumping requires large quantities of electrical energy, including about 7% of the energy of building heating, ventilation, and air conditioning (HVAC) systems. To replace pumped condenser-cooling tower water loops with a passive alternative system, we implemented a commercial-scale two-phase loop thermosyphon (TPLT). The unit consists of a 13 m riser integrated with a commercially available cooling tower and circulation water heater that simulates heat loads up to 25 kW. In addition to providing passive cooling capabilities, the cooling tower unit is also maintenance free, reliable, and can operate in both dry and wet modes. This study characterizes the performance (temperature difference between the evaporator and condenser) and the two-phase flow behavior of the loop under various refrigerant charges. Sight glasses installed throughout the loop are used to identify the operating flow regimes in the riser and downcomer. Over the range of operating conditions, we identified that there is an optimal refrigerant charge range for a specific heat load at which near-isothermal operation can be achieved. We further developed a model to predict the operating flow rate and gravitational height in the downcomer and compared it with the experimental data. The results show that the model agrees with the experimental data, in particular the threshold gravitational head height at which there will be subcooled liquid at the condenser exit, indicating that it can be used as a predictive tool for identifying the optimal loop charge for a given heat load.

Loop thermosyphon, passive two phase↗

Time-dependent density-functional theory simulation of local currents in pristine and single-defect zigzag graphene nanoribbons

The spatial current distribution in H-terminated zigzag graphene nanoribbons (ZGNRs) under electrical bias is investigated using time-dependent density-functional theory solved on a real-space grid. A projected complex absorbing potential is used to minimize the effect of reflection at simulation cell boundary. The calculations show that the current flows mainly along the edge atoms in the hydrogen terminated pristine ZGNRs. When a vacancy is introduced to the ZGNRs, loop currents emerge at the ribbon edge due to electrons hopping between carbon atoms of the same sublattice. The loop currents hinder the flow of the edge current, explaining the poor electric conductance observed in recent experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗