Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Flow loop”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Coulomb gauge QCD from flow gauge at three loops

We study the consistency of the non-Abelian Coulomb gauge. There are energy divergences in individual diagrams, which are known to cancel to 2-loop order when suitable sets of graphs are summed. We investigate to 3-loop order the inclusion of UV divergent sub-graphs into the energy divergences. In all the examples we study, we find sets of graphs which are free of energy divergences. We make use of an interpolating gauge to regularize the energy divergences while integrals are manipulated. We comment on radiative corrections to the Christ–Lee terms in the Hamiltonian.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Catalytic Resonance Theory: Forecasting the Flow of Programmable Catalytic Loops

Chemical transformations on catalyst surfaces occur through series and parallel reaction pathways. These complex networks and their behavior can be most simply evaluated through a three-species surface reaction loop (A* to B* to C* to A*) that is internal to the overall chemical reaction. Application of an oscillating dynamic catalyst to this reactive loop has been shown to exhibit one of three types of behavior: (1) a positive net flux of molecules about the loop in the clockwise direction, (2) a negative net flux of molecules about the loop in the counterclockwise direction, or (3) negligible flux of molecules about the loop at the limit cycle of reaction. Three-species surface loops were simulated with microkinetic modeling to assess the reaction loop behavior resulting from a catalytic surface oscillating between two or more catalyst surface energy states. Selected input parameters for the simulations spanned an 11-dimensional parameter space using 127 688 different parameter combinations. Their converged limit cycle solutions were analyzed for their loop turnover frequencies, the majority of which were found to be approximately zero. Classification and regression machine learning models were trained to predict the sign and magnitude of the loop turnover frequency and successfully performed above accessible baselines. Notably, the classification models exhibited a baseline weighted F1 score of 0.49, whereas trained models achieved weighted F1 scores of 0.94 and 0.96 when trained on the parameters used to define the simulations and derived rate constants, respectively. The trained models successfully predicted catalytic loop behavior, and interpretation of these models revealed all input parameters to be important for the prediction and performance of each model.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Heating-related flows in cool solar loops

The effects of spatial and temporal variations in the heating of cool loop models are investigated in an attempt to explain the net redshifts that are observed on the sun. The response of initially static cool loops to changes in the energy input is simulated. For hot loops, it is found that spatially asymmetric changes produce a final steady state that is dynamic, and that spatially symmetric changes produce a final state that is static. Some general properties of cool loop equilibria are discussed, emphasizing the relationship between structure and energy input. The results are unable to explain the net redshifts observed in emission lines formed near 100,000 K on the sun.

Klimchuk, J. A.↗

3D MHD Models of Active Region Loops

Present imaging and spectroscopic observations of active region loops allow to determine many physical parameters of the coronal loops, such as the density, temperature, velocity of flows in loops, and the magnetic field. However, due to projection effects many of these parameters remain ambiguous. Three dimensional imaging in EUV by the STEREO spacecraft will help to resolve the projection ambiguities, and the observations could be used to setup 3D MHD models of active region loops to study the dynamics and stability of active regions. Here the results of 3D MHD models of active region loops are presented, and the progress towards more realistic 3D MHD models of active regions. In particular the effects of impulsive events on the excitation of active region loop oscillations, and the generation, propagations and reflection of EIT waves are shown. It is shown how 3D MHD models together with 3D EUV observations can be used as a diagnostic tool for active region loop physical parameters, and to advance the science of the sources of solar coronal activity.

Ofman, Leon↗

Facility to Alleviate Salt Technology Risks (FASTR): Commissioning Update

The Facility to Alleviate Salt Technology Risks (FASTR) is a versatile, high-temperature (>600°C) molten chloride salt test facility designed to enable a variety of testing to advance the Generation 3 (Gen 3) concentrated solar power (CSP) molten salt technology. FASTR includes a salt preparation system and a forced flow test loop with a suite of instrumentation. The FASTR loop is capable of operating at 725°C with flow rates of 3–7 kg/s, and it includes heated and cooled sections and swappable components to facilitate testing future vendor-supplied hardware. The salt preparation system supplies large batches of clean salt for use in the FASTR forced circulation loop. This report summarizes the shakedown and initial operation of the FASTR forced circulation loop through December 2022.

14 SOLAR ENERGY↗

Fluid motions in the solar chromosphere-corona transition region. III - Active region flows from wide slit Dopplergrams

Large-scale velocity patterns observed in C IV in active regions show close correspondence with photospheric magnetic field patterns. In a large majority of cases, magnetic neutral lines show blueshift on their sun center side and redshift on their limbward side. The large-scale flow is consistent with widespread loop structure having downflow in both legs of the loops. Studies of individual bright loops, confirm that the flow is downward in most cases. However, an important subset of loops show flow from one end of the loop to the other.

Athay, R. G.↗

Effects of plasma mass flow on Alfven wave phase mixing in coronal loops

Ground-based and space observations suggest that flow phenomena are intrinsic to the solar corona loops. The present analysis addresses flow effects on Alfven wave behavior in coronal loops. The effect of flow on the shear Alfven wave continuum and the associated damping process resulting from phase-mixing is investigated. Flow Doppler-shifts the Alfven wave continuum, thus displacing the range of frequencies for optimum heating. The present study explores Alfven resonance effects on surface waves propagating along coronal loops that are under the influence of flow. Coupling to the Alfven resonance leads to damping of the surface waves. The damping rate in the presence of sub-Alfvenic flows is computed. Flow increases the damping rate of certain modes, thus enhancing the heating effectiveness of those modes. Therefore, these calculations suggest that flow is potentially an important ingredient for an accurate evaluation of heating the solar corona by dissipation of Alfven waves via phase-mixing.

Peredo, M.↗

Sensor Development for Active Flow Control

Presented are the developmental efforts for MEMS sensors for a closed-loop active flow control in a low-speed wind tunnel evaluation. The MEMS sensors are designed in-house and fabricated out of house, and the shear sensors are a thermal type that are collocated with temperature and pressure sensors on a flexible polyimide sheet, which conforms to surfaces of a simple curvature. A total of 6 sensors are located within a 1.5 by 3 mm area as a cluster with each sensor being 300 pm square. The thickness of this sensor cluster is 75 pm. Outputs from the shear sensors have been compared with respect to those of the Preston tube for evaluation of the sensors on a flat plate. Pressure sensors are the absolute type and have recorded pressure measurements within 0.05 percent of the tunnel ESP pressure sensor readings. The sensors and signal conditioning electronics have been tested on both a flat plate and a ramp in Langley s 15-Inch Low-Turbulence Tunnel. The system configuration and control PC is configured with LabView, where calibration constants are stored for desired compensation and correction. The preliminary test results are presented within.

Kahng, Seun K.↗

Assessment of Flow-Enhanced Electrochemical Sensor Testing and Deployments for MSRs

This report serves as the deliverable for Milestone M3RS-23AN0401061 that is part of Work Package RS-23AN040106 (Flow Enhanced Sensors for MSRs – ANL). The goal of this milestone was to determine performance of the flow enhanced electrochemical sensor (FEES) and modular flow instrumentation testbed (MFIT) in safeguards relevant scenarios. Flow enhanced electrochemical sensors are a type of electroanalytical sensor that has been developed at Argonne National Laboratory to be installed directly into MSR flow conduits to make measurements of the salt composition. These sensors represent a significant improvement in capabilities compared to earlier electroanalytical sensors that instead can only be operated in quiescent conditions. Previous work has focused on testing of the FEES in flowing conditions provided by the MFIT to assess the accuracy and precision of the sensor measurements. To further improve this capability, in FY23 we undertook a campaign of safeguards relevant scenarios in molten salt containing a range of uranium chloride concentrations (0 to 3 wt%). All the testing carried out in FY23 was aided by a control system designed to automatically actuate flow conditions and collect data. This new automation system is estimated to have increased experimental throughput by a factor of four and enabled testing in a variety of complex conditions. The advancements in throughput and repeatability led to improved quantification of actinide concentrations using the in-flow sensors, with a reduction of the mean absolute relative error from 5.6% in FY22 to 3.1% in FY23. In addition to safeguards scenarios run in the MFIT, FY23 work included deployment of a FEES at a partner institution where it will be tested in a flowing salt loop. The FEES was successfully integrated into that loop and is being tested prior to loop startup. In FY23, work also continued on the smaller flow system that we have named the mini-MFIT. This smaller system is capable of rapid prototyping of new sensor designs prior to installation in the larger MFIT radiological flow system. Work was carried out to test this new system in non-radiological molten salts in a separate glovebox. This work is helping us to enhance the accuracy of our salt monitoring capabilities through the integration of multiple types of sensors. The high degree of accuracy required by 10 CFR 74 represents a significant challenge, and further design evolution and integration of the sensors into multimodal sensing frameworks will be needed to further push the measurement accuracy to the needed level.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

NaK loop testing of thermoelectric converter modules (SNAP program)

The history of testing of compact tubular modules in flowing NaK loops is summarized. Test procedures, data handling, and instrument calibration are discussed. Also included is descriptive information of the test facilities, operational problems encountered, and some recommendations for testing.

Johnson, J. L.↗

Experimental investigation on multiscale hydrodynamics in a novel gas–Liquid–Solid three phase jet-Loop reactor

Multiphase flow hydrodynamics in a novel gas–liquid–solid jet-loop reactor (JLR) were experimentally investigated at the macroscales and mesoscales. The chord length distribution was measured by an optical fiber probe and transformed for bubble size distribution through the maximum entropy method. The impacts of key operating conditions (superficial gas and liquid velocity, solid loading) on hydrodynamics at different axial and radial locations were comprehensively investigated. JLR was found to have good solid suspension ability owing to the internal circulation of bubbles and liquid flow. The gas holdup, axial liquid velocity, and bubble velocity increase with gas velocity, while liquid velocity has little influence on them. Compared with the gas–liquid JLRs, solids decrease the gas holdup and liquid circulation, reduces the bubble velocity and delays the flow development due to the enhanced interaction between bubbles and particles (Stokes number >1). This work also provides a benchmark data for computational fluid dynamics (CFD) model validation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Expanding and Contracting Coronal Loops as Evidence of Vortex Flows Induced by Solar Eruptions

Eruptive solar flares were predicted to generate large-scale vortex flows at both sides of the erupting magnetic flux rope. This process is analogous to a well-known hydrodynamic process creating vortex rings. The vortices lead to advection of closed coronal loops located at the peripheries of the flaring active region. Outward flows are expected in the upper part and returning flows in the lower part of the vortex. Here, we examine two eruptive solar flares, the X1.1-class flare SOL2012-03-05T03:20 and the C3.5-class SOL2013-06-19T07:29. In both flares, we find that the coronal loops observed by the Atmospheric Imaging Assembly in its 171 Å, 193 Å, or 211 Å passbands show coexistence of expanding and contracting motions, in accordance with the model prediction. In the X-class flare, multiple expanding and contracting loops coexist for more than 35 minutes, while in the C-class flare, an expanding loop in 193 Å appears to be close by and cotemporal with an apparently imploding loop arcade seen in 171 Å. Later, the 193 Å loop also switches to contraction. These observations are naturally explained by vortex flows present in a model of eruptive solar flares.

79 ASTRONOMY AND ASTROPHYSICS↗

Thermal and Well Flow Performance of Closed-Loop Geothermal in the Wattenberg Area: Preprint

Closed-loop geothermal systems provide an alternative to resource-constrained hydrothermal systems and stimulation-intensive enhanced geothermal systems. In this work, we apply the slender-body theory (SBT) model, to simulate the well flow and heat transfer performance of U-loop well designs drilled in the Wattenberg area of the Denver-Julesburg Basin. Three U-loop well patterns are investigated including a single, double, and multi-lateral design. The subsurface within area is characterized by deep, hot (> 200degreesC) igneous/metamorphic basement rock underlying multiple sedimentary formations. The lateral section(s) of the U-loop lies within a target depth of 6 km where temperatures are estimated to approach 300degreesC. As a base case, conduction-only heat transfer is investigated through simulations with the SBT model within U-loops with open-hole laterals that exchange heat directly with the hot dry rock using water as a working fluid. The utilization of supercritical CO2 as a heat transfer fluid is also considered. For each scenario, the system performance in terms of annual heat production and temperature profile over a 20-year project lifetime are assessed. Also, the levelized costs of heat and electricity (LCOH and LCOE) are determined using a top-down technoeconomic analysis model. The results show that the performance and cost optimized U-loop design is one having an injection-production well spacing of 1,000 meters with ten 50-meter-spaced laterals that traverse a subsurface system with a temperature gradient of 60degreesC/km. By injecting 20 degreesC-water at a rate of 60 kg/s through this loop, an average heat production of 19 MWth can be achieved, resulting in an LCOE and LCOH of $136/MWh and $1.53/GJ, respectively, over a 20-year project life.

closed-loop geothermal↗

Thermal and Well Flow Performance of Closed-Loop Geothermal in the Wattenberg Area

Closed-loop geothermal systems provide an alternative to resource-constrained hydrothermal systems and stimulation-intensive enhanced geothermal systems. In this work, we apply the slender-body theory (SBT) model, to simulate the well flow and heat transfer performance of U-loop well designs in the Wattenberg area of the Denver-Julesburg Basin. Three U-loop well patterns are investigated, including a single-, double-, and multi-lateral design. The subsurface within the area of interest is characterized by deep, hot (> 200 degrees C) igneous/metamorphic basement rock underlying multiple sedimentary formations. The lateral section(s) of the U-loop lie(s) within a target depth of 6 km, where temperatures are estimated to approach 300 degrees C. As a base case, conduction-only heat transfer is investigated through simulations with the SBT model within U-loops with open-hole laterals that exchange heat directly with the hot, dry rock using water as a working fluid. The utilization of supercritical CO2 as a heat transfer fluid is also considered. For each scenario, the system performance in terms of annual heat production and temperature profile over a 20-year project lifetime are assessed. Also, the levelized costs of heat and electricity (LCOH and LCOE) are determined using a top-down techno-economic analysis model. The results show that the performance- and cost-optimized U-loop design is one having an injection-production well spacing of 1,000 meters with ten 50-meter-spaced laterals that traverse a subsurface system with a temperature gradient of 60 degrees C/km. By injecting 20 degrees C-water at a rate of 60 kg/s through this loop, an average heat production of 19 MWth (i.e., 2.2 MWe net plant output) can be achieved, resulting in an LCOE and LCOH of $136/MWhe and $1.53/GJ, respectively, over a 20-year project life.

closed-loop geothermal↗

Biomedical Support of U.S. Extravehicular Activity

The world's first extravehicular activity (EVA) was performed by A. A. Leonov on March 18, 1965 during the Russian Voskhod-2 mission. The first US EVA was executed by Gemini IV astronaut Ed White on June 3, 1965, with an umbilical tether that included communications and an oxygen supply. A hand-held maneuvering unit (HHMU) also was used to test maneuverability during the brief EVA; however the somewhat stiff umbilical limited controlled movement. That constraint, plus difficulty returning through the vehicle hatch, highlighted the need for increased thermal control and improved EVA ergonomics. Clearly, requirements for a useful EVA were interrelated with the vehicle design. The early Gemini EVAs generated requirements for suits providing micro-meteor protection, adequate visual field and eye protection from solar visual and infrared radiation, gloves optimized for dexterity while pressurized, and thermal systems capable of protecting the astronaut while rejecting metabolic heat during high workloads. Subsequent Gemini EVAs built upon this early experience and included development of a portable environmental control and life support systems (ECLSS) and an astronaut maneuvering unit. The ECLSS provided a pressure vessel and controller with functional control over suit pressure, oxygen flow, carbon dioxide removal, humidity, and temperature control. Gemini EVA experience also identified the usefulness of underwater neutral buoyancy and altitude chamber task training, and the importance of developing reliable task timelines. Improved thermal management and carbon dioxide control also were required for high workload tasks. With the Apollo project, EVA activity was primarily on the lunar surface; and suit durability, integrated liquid cooling garments, and low suit operating pressures (3.75 pounds per square inch absolute [psia] or 25.8 kilopascal [kPa],) were required to facilitate longer EVAs with ambulation and significant physical workloads with average metabolic rates of 1000 BTU/hr and peaks of up to 2200 BTU/hr. Mobility was further augmented with the Lunar Roving Vehicle. The Apollo extravehicular mobility unit (EMU) was made up of over 15 components, ranging from a biomedical belt for capturing and transmitting biomedical data, urine and fecal containment systems, a liquid cooling garment, communications cap, a modular portable life support system (PLSS), a boot system, thermal overgloves, and a bubble helmet with eye protection. Apollo lunar astronauts performed successful EVAs on the lunar surface from a 5 psia (34.4 kPa) 100% oxygen environment in the Lunar Lander. A maximum of three EVAs were performed on any mission. For Skylab a modified A7LB suit, used for Apollo 15, was selected. The Skylab astronaut life support assembly (ALSA) provided umbilical support through the life support umbilical (LSU) and used open loop oxygen flow, rather than closed-loop as in Apollo missions. Thermal control was provided by liquid water circulated by spacecraft pumps and electrical power also was provided from the spacecraft via the umbilical. The cabin atmosphere of 5 psia (34.4 kPa), 70% oxygen, provided a normoxic atmosphere and because of the very low nitrogen partial pressures, no special protocols were required to protect against decompression sickness (DCS) as was the case with the Apollo spacecraft with a 5 psi, 100% oxygen environment.

Gernhardt, Michael L.↗

Icing of flow conditioners in a closed-loop wind tunnel

Described are the results of an experiment which determined whether flow conditioning screens and honeycombs would ice up in a closed-loop icing wind tunnel when placed downstream of the heat exchanger and upstream of the spray bars. The experiment was performed in the Icing Research Tunnel (IRT) at NASA Lewis Research Center. The investigation involved two separate tests: one to find the icing characteristics of flow conditioners in the IRT, and the second to find the icing characteristics of flow conditioners in the proposed rehabilitation of the Altitude Wind Tunnel (AWT). Both experiments showed that the heat exchanger removed nearly all of the icing cloud so that icing of the flow conditioners would cause no serious tunnel performance degradation during the course of a day's run. Only extremely cold conditions caused frost formation on the flow conditioners. The significance of this frost formation was minimized because frost buildup on the heat exchanger caused a much more severe pressure drop than did icing of the flow conditioners.

Newton, James E.↗

Nonintrusive Flow Rate Determination Through Space Shuttle Water Coolant Loop Floodlight Coldplate

Using a Nonintrusive Flow Measurement System (NFMS), the flow rates through the Space Shuttle water coolant coldplate were determined. The objective of this in situ flow measurement was to prove or disprove a potential block inside the affected coldplate had contributed to a reduced flow rate and the subsequent ice formation on the Space Shuttle Discovery. Flow through the coldplate was originally calculated to be 35 to 38 pounds per hour. This application of ultrasonic technology advanced the envelope of flow measurements through use of 1/4-inch-diameter tubing, which resulted in extremely low flow velocities (5 to 30 pounds per hour). In situ measurements on the orbiters Discovery and Atlantis indicated both vehicles, on the average, experienced similar flow rates through the coldplate (around 25 pounds per hour), but lower rates than the designed flow. Based on the noninvasive checks, further invasive troubleshooting was eliminated. Permanent monitoring using the NFMS was recommended.

Werlink, Rudolph↗