Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Flow cell”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Chloride-Based Volatility for Waste Reduction and/or Reuse of Metallic-, Oxide- and Salt-Based Reactor Fuels

The objective of the chloride based volatility project (CBV) was to demonstrate the ability to separate uranium from used fuel to enable process improvements resulting in 10x reduction of waste volume, while maintaining safeguards standards and global backend costs at $\$$1/MW-hr. Current industrial practices perform separations of used fuel using solvent media in the form of aqueous and molten salt processes, resulting in contaminated process waste. The CBV approach utilized solid state chemistry with no solvent media and was successful in chlorinating uranium and fission product oxides that sublimed into the gas phase and were collected in targeted condensation zones based on temperature gradients of chlorinated products. Recovery of better than 95% of initial uranium in the form of UCl4 was demonstrated when simulated used nuclear fuel was used. Laser induced breakdown spectroscopy, LIBS, and ultraviolet-visible spectroscopy, UV-Vis, were combined into a high temperature flow cell design and utilized as process monitoring techniques to observed chlorinated products leave the reaction vessel in real time.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Findings from Large Bench-Scale Testing of Denitration Electrolyzers for the EDCGe Project

This report highlights the key findings and outcomes relevant to the processability of waste supernatant at Hanford using a denitration electrolyzer. The Electrosynthesis Company issued a Phase 1 report to the Savannah River National Laboratory (SRNL), summarizing the evaluation of large bench-scale denitration electrolyzers to support the electrochemical denitration and caustic generation (EDCGe) project. The Electrosynthesis Company’s report (attached as Appendix A) provides insights into the initial steps required to implement an electrolyzer system at Hanford. Phase 1 experiments focused on validating the denitration electrolyzer’s performance, operating parameters, and reaction products. The robustness of the electrochemical denitration process was demonstrated by two electrolyzer flow cell systems (a 100 cm 2 ElectroCell MP and a 150 cm 2 NESI NS01 cell), both of which achieved significant nitrate and nitrite removal (>50%) with a current efficiency of ~95% for both systems. Higher current densities (500 mA cm –2 ) improved nitrate and nitrite removal rates compared to lower current densities (333 mA cm –2 ), while maintaining a current efficiency of ~94%. The NS01 cell achieved a nitrate species removal rate of ~0.41 mol h –1 at 5 kA m –2 (equiv. to 500 mA cm –2 ). The primary reaction product was ammonia (NH 3 ), constituting 78.3–91.6% of the products (excluding OH – formation). NH 3 was predominantly retained in the catholyte liquid phase rather than being off-gassed. Additionally, the NS01 cell reported an NH 3 generation rate of ~0.36 mol h –1 at 5 kA m –2 . Other gas formation included ~7% N 2 , ~7% H 2 , and trace amounts of N 2 O. The estimated power requirement (extrapolated from the 0.015 m 2 cell data) for a full-scale denitration electrolyzer is approximated to be ~1.6 MW (DC-only) to treat 50% of nitrate and nitrite in a waste stream and generates ~2.1 kmol h –1 of NH 3 with an initial concentration of 4 M NO 3 – /NO 2 – at 300 gal h –1 . Simulated waste containing aluminate, carbonate, oxalate, and halogens exhibited no adverse effects on denitration performance. A preliminary experiment comparing alkaline anolyte (5 M NaOH) with a nickel based anode to acidic media (2 M H 2 SO 4 ) with a DSA-O 2 anode showed a lower operating voltage and generated less H 2 than the acid media. Maintaining a stable 5 M OH – concentration in the anolyte through periodic additions of caustic did not significantly impact denitration performance. This operational mode will be required for long-term experiments. All the experiments demonstrated that electrochemical denitration is a promising approach for treating nitrate and nitrite in simulated waste streams, achieving significant conversion and robustness across varying experimental conditions and electrochemical cell configurations. Lastly, the ability to generate a nearly pure NH 3 stream may prove advantageous for processing at other locations within the Hanford site.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Novel Dew Point Meter: Application to the Measurement of the Sulfuric Acid Dew Point for Combustion Flue Gas

Accurate knowledge of acid dew point is essential for industrial and applied combustion applications. Sulfur in the fuel or raw materials is converted to sulfur dioxide (SO2) during combustion, and a portion of the SO2 is oxidized to sulfur trioxide (SO3). The SO3 will react to form H2SO4 vapor when in the presence of water vapor. Even with just trace levels of H2SO4 vapor in the gas phase (1-10 ppm), the dew point can reach 100°C and higher. To avoid acid condensation and the resulting corrosion on heat recovery equipment, plant engineers must ensure that surface temperatures are above the acid dew point, but this decreases the efficiency of thermal energy recovery. Thus, there is a trade-off between minimizing equipment corrosion and maximizing thermal energy recovery, and the acid dew point is a key parameter for this optimization. Commercially available acid dew point meters use electric conductivity sensors. These sensors are known to greatly underestimate the dew point due to their low sensitivity. In addition, no validation testing has been reported for these units and they are often expensive. In this work, we analyze the theory of the sulfuric acid condensation and develop a novel dew point meter based on this analysis. The meter consists of a novel optical instrument that is designed to monitor the slightest appearance of condensation on a hydrophobic window surface as the surface temperature of the window is slowly decreased. In this way, an accurate measurement of the dew point is obtained under a wide range of concentrations. The basis of the instrument is that a collimated beam from a diode laser will generate forward scattered light when the beam encounters surface condensate, and a sophisticated array detector is used to sensitively monitor the onset of light scattering. The measurement procedures are established to rapidly find the acid dew point, while minimizing error. Further, to calibrate the dew point meter we developed a calibration system based on a liquid bubbler that can generate a stable gas flow with a known sulfuric acid dew point. Test results show that the dew point meter can accurately measure acid dew point over a wide range. For H2SO4 vapor concentrations as low as 6 ppm the acid dew point is measured with an error of only ~1°C. To demonstrate the versatility of this instrument, the dew point meter was adapted for use with a high-pressure flow cell to allow for measurements of the dew point of flue gas from pressurized oxy-fuel combustion in a 100 kWth pressurized reactor.

Cheng, Mao↗

Amplification-free nucleic acid detection with a fluorescence-based waveguide biosensor

Early detection of pathogens using nucleic acids in clinical samples often requires sensitivity at the single-copy level, which currently necessitates time-consuming and expensive nucleic acid amplification. Here, we describe 1) a redesigned flow cell in the shape of a trapezoid-subtracted geometric stadium, and 2) modified experimental procedures that allow for the measurement of sub-attomolar analytes in microliter quantities on a fluorescence-based waveguide biosensor. We verified our instrumental sensitivity with a 200-μL sample of a fluorescent streptavidin conjugate at 100 zM (100 zeptomolar, or 100·10 −21 mol L −1 ) and theoretically explored the applicability of this modified sensing platform in a sandwich immunoassay format using a Langmuir adsorption model. We present assays that demonstrate specific detection of synthetic influenza A DNA (in buffer) and RNA (in saliva) oligonucleotides at the single-copy level (200 μL at 10 zM) using a fluorescent molecular beacon. Lastly, we demonstrate detection of isolated genomic influenza A RNA at a clinically relevant concentration. This work constitutes a sensitivity improvement of over twelve orders of magnitude compared to our previous nucleic acid detection work, illustrating the significant enhancements that can be gained with optimized experimental design.

59 BASIC BIOLOGICAL SCIENCES↗

Online Monitoring of Catalytic Processes by Fiber-Enhanced Raman Spectroscopy

An innovative solution for real-time monitoring of reactions within confined spaces, optimized for Raman spectroscopy applications, is presented. This approach involves the utilization of a hollow-core waveguide configured as a compact flow cell, serving both as a conduit for Raman excitation and scattering and seamlessly integrating into the effluent stream of a cracking catalytic reactor. The analytical technique, encompassing device and optical design, ensures robustness, compactness, and cost-effectiveness for implementation into process facilities. Notably, the modularity of the approach empowers customization for diverse gas monitoring needs, as it readily adapts to the specific requirements of various sensing scenarios. As a proof of concept, the efficacy of a spectroscopic approach is shown by monitoring two catalytic processes: CO 2 methanation (CO 2 + 4H 2 → CH 4 + 2H 2 O) and ammonia cracking (2NH 3 → N 2 + 3H 2 ). Leveraging chemometric data processing techniques, spectral signatures of the individual components involved in these reactions are effectively disentangled and the results are compared to mass spectrometry data. This robust methodology underscores the versatility and reliability of this monitoring system in complex chemical environments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Full-Length ASFV B646L Gene Sequencing by Nanopore Offers a Simple and Rapid Approach for Identifying ASFV Genotypes

African swine fever (ASF) is an acute, highly hemorrhagic viral disease in domestic pigs and wild boars. The disease is caused by African swine fever virus, a double stranded DNA virus of the Asfarviridae family. ASF can be classified into 25 different genotypes, based on a 478 bp fragment corresponding to the C-terminal sequence of the B646L gene, which is highly conserved among strains and encodes the major capsid protein p72. The C-terminal end of p72 has been used as a PCR target for quick diagnosis of ASF, and its characterization remains the first approach for epidemiological tracking and identification of the origin of ASF in outbreak investigations. Recently, a new classification of ASF, based on the complete sequence of p72, reduced the 25 genotypes into only six genotypes; therefore, it is necessary to have the capability to sequence the full-length B646L gene (p72) in a rapid manner for quick genotype characterization. Here, we evaluate the use of an amplicon approach targeting the whole B646L gene, coupled with nanopore sequencing in a multiplex format using Flongle flow cells, as an easy, low cost, and rapid method for the characterization and genotyping of ASF in real-time.

Virology↗

Altering translation allows E. coli to overcome chemically stabilized G-quadruplexes

Genomic DNA from each sample was prepared using the Wizard Genomic DNA Purification Kit (Promega) and after, DNA was quantified using the QuantiFluor ONE dsDNA System (Promega). Genomic DNA underwent shearing to ~200 bp fragments via sonication and the gDNA fragments were prepared for sequencing using the NEBNext Ultra II DNA Library Prep Kit for Illumina (NEB). Bead-based size selection was used to select ~200 bp fragments and the fragments then underwent a splinkerette PCR using a Tn5-enriching forward primer and custom reverse primers for multiplexing. A final bead-based size selection was used to select for the correct length DNA. DNA was sequenced at the University of Michigan Advanced Genomics Core using Illumina sequencing with a custom read primer reading the last 10 nt of the transposon. PhiX174 DNA spike was added to the run to ensure sufficient sequence diversity on the flow cell. Then, a custom index read primer and standard Illumina primer were used to sequence the index reads and PhiX174, respectively.

Keck, James L.↗

REDOX - electrochemical energy storage

Rechargeable system, which operates at relatively low temperatures from room temperature to about 353 K, consists of analyte and catholyte storage tanks connected to flow cell.

Warshay, M.↗

Experiments on atmospheric processes

Spacelab technology is examined as applied to the observation of the earth's weather patterns, composition, thermodynamics, and kinematics. An atmospheric cloud physics laboratory and a geophysical fluid flow cell are individually outlined as planned payload experiment efforts.

Vaughan, W. W.↗

Advanced designs for fluid flow visualization

Research was carried out on existing and new designs for minimally intrusive measurement of flow fields in the Geophysical Fluid Flow Cell and the proposed Atmospheric General Circulation Experiment. The following topics are discussed: (1) identification and removal of foreign particles, (2) search for higher dielectric photochromic solutions, (3) selection of uv light source, (4) analysis of refractive techniques and (5) examination of fresnel lens applicability.

Source record↗

Heterogeneous atmospheric reactions - Sulfuric acid aerosols as tropospheric sinks

The reaction probabilities of various atmospheric species incident on a bulk sulfuric acid surface are measured in order to determine the role of sulfuric acid aerosols as pollutant sinks. Reaction products and unreacted starting materials leaving a Knudsen cell flow reactor after collision at 300 K with a H2SO4 surface or a soot surface were detected by mass spectrometry. Significant collision reaction probabilities are observed on a H2SO4 surface for H2O2, HNO3, HO2NO2, ClONO2, N2O5, H2O and NH3, and on soot for NH3. Estimates of the contribution of heterogeneous reactions to pollutant removal under atmospheric conditions indicate that while aerosol removal in the stratosphere is insignificant (loss rate constants approximately 10 to the -10th/sec), heterogeneous reactions may be the dominant loss process for several tropospheric species (loss rate constant approximately 10 to the -5th/sec, comparable to photolysis rate constants).

Baldwin, A. C.↗

Global weather research

Modeling, prediction, and analysis of global meteorological phenomena influencing the large scale behavior of the atmosphere are summarized. Prediction of global weather phenomena based on satellite data is discussed and models of global phenomena developed. The atmospheric general circulation model (AGCE) is reviewed, axisymmetric flow calculated, and axisymmetric states in cylindrical, spherical, three dimensional, and spin up numerical models for AGCE described. The role of latent heat release in baroclinic waves, latent heat and cyclonic systems, and a theoretical study of baroclinic flow related to the AGCE and the flow regime were studied with a simplified general circulation model. AGCE and the geophysical fluid flow cell (GFFC) instrumentation are discussed. Investigation of solar and planetary convection for GFFC is described. The utilization of satellite cloud observations to diagnose the energy state and transformations in extratropical cyclones is reviewed.

Source record↗

A model of the high-latitude ionospheric convection pattern

Mathematical expressions have been constructed that allow the large-scale global convection characteristics of the high-latitude ionosphere to be reproduced. The model contains no discontinuities in the ion convection velocity and as such should be useful in F region chemical models. The number of variables in the model allow such features as the dayside throat and the Harang discontinuity to be modeled. The applicability of the model to magnetospheric physics is limited by the exclusion of large-magnitude small-scale flow features associated with discrete arcs and by the inability of the model to produce separate flow cells at the same local time.

Heelis, R. A.↗

Theoretical and experimental studies in support of the geophysical fluid flow experiment

Computer programming was completed for digital acquisition of temperature and velocity data generated by the Geophysical Fluid Flow Cell (GFFC) during the upcoming Spacelab 3 mission. A set of scenarios was developed which covers basic electro-hydrodynamic instability, highly supercritical convection with isothermal boundaries, convection with imposed thermal forcing, and some stably stratified runs to look at large-scale thermohaline ocean circulations. The extent to which the GFFC experimental results apply to more complicated circumstances within the Sun or giant planets was assessed.

Hart, J.↗

GFFC experiment progress

Vibration, out-gas, and acoustic tests performed on the Geophysical Fluid Flow Cell (GFFC) instrument are reported. The slope of the 59 experiments to be performed by GFFC is outlined. Spacelab 3 crew training on the operation of the GFFC instrument is mentioned.

Leslie, F.↗

Temperature dependent electronic quenching of OH(A 2 Sigma +, v-prime = 0) between 230 and 310 K

The present study is concerned with the electronic quenching of OH(A 2 Sigma +, v-prime = 0) at and below room temperature, taking into account the use of laser-induced fluorescence (LIF) in a low pressure flow cell for H2, CO2, O2, and N2 colliders. The reasons for the selection of the temperature range and the collision partners are related to the quantitative calibration of OH detection techniques in the troposphere, and to considerations of electronic quenching dynamics. Attention is given to production and rotational distribution, temperature measurements, and temperature dependent quenching rate constants.

Copeland, R. A.↗

Theoretical and experimental studies in support of the geophysical fluid flow experiment

Meteorologists and astrophysicists interested in large scale planetary and solar circulations have come to recognize the importance of rotation and stratification in determining the character of these flows. In particular, the effect of latitude-dependent Coriolis force on nonlinear convection is thought to play a crucial role in such phenomena as differential rotation on the Sun, cloud band orientation on Jupiter, and the generation of magnetic fields in thermally driven dynamos. The continuous low-gravity environment of the orbiting space shuttle offers a unique opportunity to make laboratory studies of such large-scale thermally driven flows under the constraint imposed by rotation and sphericity. This is possible because polarization forces in a dielectric liquid, which are linearly dependent on fluid temperature, give rise to an effectively radial buoyancy force when a radial electrostatic field is imposed. The Geophysical Fluid Flow Cell (GFFC) is an implementation of this ideal in which fluid is contained between two rotating hemispheres that are differentially heated and stressed with a large a-c voltage. The experiment, to be flown on Spacelab III (currently set for launch April 29, 1985), will explore non-linear mode selection and high Rayleigh number turbulence in a rotating convecting spherical shell of liquid. Experiments will be carried out in a low driving parameter range where some limited numerical experimentation is currently feasible, as well as in a parameter range significantly beyond numerical computation for many years.

Hart, J.↗