Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fire Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Final Report for FE0032098: Improving the cost-effectiveness of algal CO2 utilization by synergistic integration with power plant and wastewater treatment operations

The overall goal of this project was to demonstrate an engineering-scale open raceway pond algae cultivation system (approximately 180 m²), including the integration of technologies that utilized carbon dioxide (CO₂) from a coal-fired power plant and wastewater-derived nutrient inputs for cost-effective and environmentally friendly biomass production. The key advantages associated with the innovative algae cultivation system and its integration with wastewater treatment functions, as described herein, had been demonstrated in previous bench- and pilot-scale work by the project team partners. This project combined those approaches to maximize practical benefits and available synergies, resulting in a significant reduction in the net cost of producing algal biomass products. The primary target algal species for the project was Spirulina, which served as a high-protein content ingredient for food and animal feed. Spirulina was selected because it had already been approved by the FDA, was in use as a food ingredient, and commanded prices of up to $30/kg. It had a typical protein content of 50–75%, comparable to other high-protein concentrates, featured high digestibility without requiring pretreatment, and offered a high conversion ratio in animal feed applications. In addition, Spirulina had a relatively high content of the blue pigment phycocyanin, which could be extracted as a high-value co-product prior to using the remaining biomass for nutritional purposes.

Schideman, Lance [University of Illinois]↗

A legacy of fire emerges from multiple disturbances to most shape microbial and nitrogen dynamics in a deciduous forest

Healthy forests are vital components of terrestrial ecosystems for their raw materials, high biodiversity, cycling of nutrients, and potential to sequester carbon. However, these ecosystems are sensitive to disturbances, and anthropogenic activities pose a serious threat to forest ecosystems globally. For example, human activities have dramatically altered multiple historical disturbance regimes in forests, including suppressing fire, increasing the density of large herbivores, and reducing the size of canopy gaps, among other disturbances. Such disturbances can have dramatic impacts on microbially-mediated forest soil functions, but more research is needed to determine the collective impacts of these disturbances. In this study, we investigated the interactive effects of disturbances, namely the legacies of fire, large herbivore densities, and canopy gap creation, in a deciduous forest soil. We determined that forest floor and mineral soil carbon and nitrogen pools were shaped by multiple disturbances, but fire was more influential than the other disturbances. The abundance of several functionally-relevant microbial taxa were significantly impacted by fire, and the effect was more pronounced in the mineral soil than in the forest floor. Together, these findings demonstrate that multiple disturbances, especially a legacy of fire, exerts long-term control over soil carbon, nitrogen and microbial dynamics in a deciduous forest system.

59 BASIC BIOLOGICAL SCIENCES↗

Electrochemical Conversion of Carbon Dioxide to Alcohols

The vast quantities of fossil fuels used by our society have led to unprecedented atmospheric carbon dioxide levels with widespread climate impacts. Electrochemical conversion of carbon dioxide to valuable fuels and chemicals is a promising technology to utilize carbon dioxide emitted from coal-fired power plants. In this project, the team developed an integrated electrolyzer system that takes the flue gas from the power plant and produce C2/C3 alcohols (i.e., ethanol and n-propanol) through a two-stage electrolysis process. The pretreated carbon dioxide from the flue gas is converted into carbon monoxide by the first stage carbon dioxide electrolysis, followed by the second stage where the produced carbon monoxide is further converted into liquid C2/C3 alcohols with a high selectivity and energy efficiency. Impact and anticipated fate of flue gas contaminants, such as sulfur dioxide and nitrogen oxides, on the proposed technology was also evaluated. Furthermore, a full analysis of economics and life-cycle of the carbon dioxide electrolysis technology for carbon dioxide emissions mitigation from coal-fired power plants was conducted to evaluate the economic feasibility and carbon dioxide mitigation potential of the proposed technology.

20 FOSSIL-FUELED POWER PLANTS↗

Land-use history, fire regime, and large-mammal herbivory affect deer-preferred plant diversity in longleaf pine woodlands

Since ecological systems often experience multiple disturbances, understanding changes in important ecological interactions, such as plant-herbivore interactions, may require studies capable of disentangling the unique and interactive effects of multiple forms of disturbance. For example, understanding how mammalian herbivores affect plant communities may require understanding how widespread past disturbances, such as agricultural land use, interact with contemporary disturbances, such as prescribed fire. Here, we tested if past agricultural land use and contemporary fire regime modified the effects of mammalian herbivory on focal plant communities by measuring the richness of plant species preferred by deer at 26 longleaf pine woodlands containing paired open and large-mammal exclusion plots. Land-use history significantly affected the community composition of deer-preferred species, and focal species were 8.19 times more likely to be present in post-agricultural sites than non-agricultural sites. Large-mammal herbivory only affected plant species richness in woodlands with low fire frequencies wherein focal species were on average 2.23 times more likely to be present in exclusion plots than open plots. These results suggest that past and present disturbances can mediate contemporary plant-animal interactions and may explain spatial patterns in the intensity of large-mammal herbivory. Our findings also suggest that common management practices, such as use of prescribed burns, may indirectly promote plant species richness by reducing deer herbivory.

60 APPLIED LIFE SCIENCES↗

Quantifying the reductions in mortality from air-pollution by cancelling new coal power plants

Deep decarbonization paths to the 1.5°C or 2°C temperature stabilization futures require a rapid reduction in conventional coal-fired power plants, but countries are currently building 223 GW of new coal power capacity and plan to build 377 GW more in the next decade. Coal-fired plants are also a major contributor to air pollution related health impacts. Here, we couple an integrated human-earth system model (GCAM) with an air quality model (TM5-FASST) to examine regional health co-benefits from cancelling new coal-fired plants worldwide. Additionally, we find that cancelling all new proposed projects would decrease air pollution related premature mortality between 101,388 - 213,205 deaths (2-5%) in 2030, and 213,414 - 373,054 (5-8%) in 2050, globally, but heavily concentrated in developing Asia. Furthermore, we estimate that strengthening the climate target from 2°C to 1.5°C would avoid 326,351 additional mortalities in 2030, of which 251,011 (75%) are attributable to the incremental coal plant shutdown.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Ceramic High Efficiency Particulate Air (HEPA) Filter Research and Development at Lawrence Livermore National Laboratory

Ceramic high efficiency particulate air (HEPA) filter development program began at Lawrence Livermore National Laboratory (LLNL) over 20 years ago. Historical incidents motivated current safety systems at nuclear facilities. A ceramic filter that can survive a fire can provide robust, passive safety protection. Research has been conducted to improve the safety of nuclear facilities and to reduce operational and lifecycle costs, through ceramic filter technology that can survive fire conditions. Here, the research focused on applications in both new facilities as well as meeting operational requirements necessary to retrofit filters into existing DOE facilities. The research has developed multiple filter technologies spanning traditional HEPA filter materials to advanced manufacturing technologies (e.g., electrospinning, additive manufacturing, etc.). This communication will present highlights of selected development efforts for ceramic HEPA filter research, current state-of-the-art for ceramic filters, and future needs including technical, regulatory, and commercial efforts.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Spin frustration and an exotic critical point in ferromagnets from nonuniform opposite g factors

Here, it is demonstrated that novel spin frustration can be induced in ferromagnets with nonuniform opposite Landé g-factors. The frustrated state is characterized by a mutual interplay of typical ferromagnetic (FM) and antiferromagnetic (AF) features, such as the zero-field susceptibility being FM-like at low temperatures but AF-like at high temperatures. It is also found to contain an exotic zero-temperature 'half fire, half ice' critical point at which the spins on one sublattice are fully disordered and on the other one are fully ordered. We suggest that such frustration may occur in a number of copper-iridium oxides such as Sr 3 CuIrO 6 . We also anticipate a realization of the frustration and 'partial fire, partial ice' states in certain antiferromagnets, lattice gas, and neuron systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Approaches for Water Removal in Direct-Fired sCO 2 Power Cycles

There is interest in investigation of water removal processes in direct fired sCO 2 flows, as this may potentially lead to greater system efficiency as the removal of this contaminant will result in sCO 2 behaving close to idealized behaviors. Water removal should be split into a two-step process, condensation of the water, followed by separation of the liquid phase water from the sCO 2 . The two main avenues of condensation are manipulation of pressure and temperature for phase change. For this paper, temperature-based phase change is the primary focus through the implementation of heat exchangers. Of the heat exchangers investigated it was found that printed circuit heat exchangers (PCHEs) could be an alternative for this use case, though the specific design of flow channel geometry and flow direction depends on the specific system case and cannot be determined at this point. For water separation there were four processes identified, all of which already assume water is in liquid phase at that point in the system. Of these separation avenues the best candidate is the hydrocyclone as it has a proven history of separating liquid-liquid phase mixtures with small density differences in oilfield use, in addition they have been investigated and modeled specifically for water separation for sCO 2 flows and the footprint is relatively small.

20 FOSSIL-FUELED POWER PLANTS↗

Rapid Characterization and Statistical Analysis of High-Volume Field-Harvested Photovoltaic Connectors

Photovoltaic (PV) installations heavily depend on connectors for efficient module and string interconnections without requiring skilled labor. Yet this seemingly innocuous component of PV systems is a leading cause of module failures, multiple high-profile fires, and lawsuits in the PV industry. This work aims to answer critical questions regarding why connectors fail and the contributing factors to their failure. The study involves collecting and analyzing more than 17,000 field-harvested connectors from various solar installations across the United States. The vast dataset, which includes connector metadata, visual inspections, and resistance measurements, provides unprecedented insight into the state of health of PV connectors across the US, including the geographic locations, connector types, and installation practices most prone to failures. The work presented here describes a novel rapid characterization method for processing large numbers of connectors and is supported by parallel forensic analysis to discern the root causes of failures as well as a levelized cost of lifetime model to determine the economic ramifications of connector failure. Ultimately, the findings may inform PV developers about the best practices to extend connector longevity and lead to more resilient and reliable PV systems.

connectors↗

Long-term drought promotes invasive species by reducing wildfire severity

Anthropogenic climate change has increased the frequency of drought, wildfire, and invasions of non-native species. Although high-severity fires linked to drought can inhibit recovery of native vegetation in forested ecosystems, it remains unclear how drought impacts the recovery of other plant communities following wildfire. We leveraged an existing rainfall manipulation experiment to test the hypothesis that reduced precipitation, fuel load, and fire severity convert plant community composition from native shrubs to invasive grasses in a Southern California coastal sage scrub system. We measured community composition before and after the 2020 Silverado wildfire in plots with three rainfall treatments. Drought reduced fuel load and vegetation cover, which reduced fire severity. Native shrubs had greater prefire cover in added water plots compared to reduced water plots. Native cover was lower and invasive cover was higher in postfire reduced water plots compared to postfire added and ambient water plots. Our results demonstrate the importance of fuel load on fire severity and plant community composition on an ecosystem scale. Management should focus on reducing fire frequency and removing invasive species to maintain the resilience of coastal sage scrub communities facing drought. In these communities, controlled burns are not recommended as they promote invasive plants.

54 ENVIRONMENTAL SCIENCES↗

Atikokan Digital Twin: Machine learning in a biomass energy system

The Atikokan Generating Station, operated by Ontario Power Generation, has a 200 MW, biomass-fired tower boiler that operates on a dispatch schedule with a five-minute cycle. The boiler is generally operated in the range of 40–100 MW using two of five burner levels. In order to optimize boiler performance, we propose the implementation of a unique digital twin. Our digital twin abstraction couples Bayesian inference from science-based models and from observations (machine learning) with decision theory to predict operating-variable set points that optimize the physical asset (the boiler) in the presence of uncertainty (artificial intelligence). We focus this paper on the continuous Bayesian machine learning part of the Atikokan Digital Twin; we discuss decision theory in a companion paper. We identify and learn about 12 operational, model, and measured-output parameters and their uncertainties from high-fidelity, science-based simulations of the Atikokan boiler and from the observed measurements at the power plant. Since the goal of the Atikokan Digital Twin is to implement it online in real time, we require fast function evaluations for the quantities of interest extracted from the simulations in the Bayesian analysis. We use Gaussian process regression/interpolation to create accurate, robust surrogate models. We define the Bayesian priors and likelihood function and solve for the posterior distributions of the 12 parameters. Here we then propagate these distributions (i.e., parameters with uncertainty) into the predicted distributions of 790 quantities of interest to learn about the relative importance of various sources of error including experimental, model, and operating-parameter errors.

09 BIOMASS FUELS↗

Projections of wildfire risk and activities under 1.5 °C and 2.0 °C global warming scenarios

Wildfires are important ecosystem processes that have a significant impact on terrestrial vegetation, environment, and climate. This study investigates how future wildfire risk and activities could change under 1.5 °C and 2.0 °C warming scenarios relative to pre-industrial levels using a modified McArthur Forest Fire Danger Index (FFDIn) and the CLM4.5-BGC land surface model. Sixteen Earth System Models (ESMs) from CMIP5 and CMIP6 were employed to supply the variables of climate change under low, middle, and high greenhouse emission scenarios in the 1.5 °C and 2.0 °C scenarios. The ensemble means from the FFDIn and results from the CLM4.5-BGC with multiple forcings show that the dry areas in the southwestern US, Brazilian Highlands, and Arabian islands are projected to face higher wildfire risk with larger burned areas and more carbon emissions under a warmer climate. The Congo Basin and part of the Amazon could have a lower wildfire risk with smaller burned areas and less carbon emissions. The absolute changes in the projected FFDIn are small, although large increases are observed in boreal areas, particularly in the winter and spring. Burned area and carbon emissions are projected to increase in general in the boreal area but decrease in northeastern Asia. Compared to the 1.5 °C scenario, the wildfire risk and burned area levels are projected to increase under the 2.0 °C scenario except in the western Amazon. However, fire carbon emissions are projected to decrease more in tropical areas under the 2.0 °C scenario. The different change directions in eastern North America and eastern China produced by the FFDIn and CLM4.5-BGC suggest the potential effect of non-meteorological elements on fire activities.

1.5 °C and 2.0 °C warming↗

Development of Miniaturized High Temperature Multi Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. This project leveraged the existing electrochemical noise-based monitoring system and the new sensor design is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data is transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, the three mMPMS were installed at a full-scale pulverized coal-fired plant, PacifiCorp’s Hunter 3. The systems were demonstrated over 20,000 hours at the plant during regular operation. Also, the sensor data was fed to the plant’s advanced process control system to evaluate the corrosion control by the operation changes and utilized to understand the impacts of load cycling with different ramping up and down speeds. At the end of the project, the systems were converted to the permanent installation at the power plant to be used with the advanced process control system installed at the plant.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

A. Development of Miniaturized High Temperature Multi Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. This project leveraged the existing electrochemical noise-based monitoring system and the new sensor design is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data is transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, the three mMPMS were installed at a full-scale pulverized coal-fired plant, PacifiCorp’s Hunter 3. The systems were demonstrated over 20,000 hours at the plant during regular operation. Also, the sensor data was fed to the plant’s advanced process control system to evaluate the corrosion control by the operation changes and utilized to understand the impacts of load cycling with different ramping up and down speeds. At the end of the project, the systems were converted to the permanent installation at the power plant to be used with the advanced process control system installed at the plant.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

High-Temperature Multi-Process Sensor Development and Demonstration at Coalfired Power Plants

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. This project leveraged the existing electrochemical noise-based monitoring system and the new sensor design is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data is transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, the three mMPMS were installed at a full-scale pulverized coal-fired plant, PacifiCorp’s Hunter 3. The systems were demonstrated over 20,000 hours at the plant during regular operation. Also, the sensor data was fed to the plant’s advanced process control system to evaluate the corrosion control by the operation changes and utilized to understand the impacts of load cycling with different ramping up and down speeds. At the end of the project, the systems were converted to the permanent installation at the power plant to be used with the advanced process control system installed at the plant.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

High-Temperature Multi-Process Sensor Development and Demonstration at a Full-scale PC Combustion System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. This project leveraged the existing electrochemical noise-based monitoring system and the new sensor design is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data is transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, the three mMPMS were installed at a full-scale pulverized coal-fired plant, PacifiCorp’s Hunter 3. The systems were demonstrated over 20,000 hours at the plant during regular operation. Also, the sensor data was fed to the plant’s advanced process control system to evaluate the corrosion control by the operation changes and utilized to understand the impacts of load cycling with different ramping up and down speeds. At the end of the project, the systems were converted to the permanent installation at the power plant to be used with the advanced process control system installed at the plant.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

Experimental study on particle formation in a pressurized oxy-fuel combustor using a novel in-situ optical instrument

Particle formation in pressurized oxy-fuel combustion can be fundamentally different from oxy-fuel combustion at atmospheric pressure. Under high pressures, the rate of char gasification with CO2 and H2O increases significantly and dominates the char reactions particularly at high temperatures. Also, the extent of fragmentation varies. This could result in a very different particle size distribution from that of air-fired combustion. To accurately obtain the particle size distribution in a pressurized oxy-fuel combustor without sampling bias, the particle measurement should be made at the system pressure. Very few published studies have accomplished this, and never under the conditions reported herein. In this work, we fire PRB coal in a 100 kWth staged pressurized oxy-fuel combustor (SPOC) under two pressures, 15 and 2 bara. A sampling probe (oil-cooled) is installed at the combustor outlet and the aerosol flow are sampled isokinetically. We utilize a state-of-the-art optical analyzer (Malvern Insitec) with a novel high-pressure and high-temperature flow cell to measure the particle size distribution and concentration in-situ in a sampled flow, which contains moist/corrosive flue gas under the process pressure and a controlled temperature that is kept above the dew point. The results show that the pressure can significantly influence the particle size distribution and concentration from the oxy-fuel combustor.

Cheng, Mao↗

Deployment of Dynamic Neural Network Optimization to Minimize Heat Rate During Ramping for Coal Power Plants (Final Technical Report)

Much success was achieved throughout the course of this project. A successful implementation of Dynamic Neural Network Optimization (D-NNO) was coupled with Adaptive Predictive Controls (APC) and a novel hardware installation comprised of an advanced sensor network (ASN) measuring mass-weighted averages of flue gas constituents above the horizontal superheater of a coal-fired utility boiler. From 2019 through 2023 (including an extension due to COVID delays), the team was able to prototype, evaluate, deploy, iterate, and ultimately finalize an advanced closed-loop control D-NNO system which demonstrated the ability to: •improve unit efficiency ~2.0% relative to unoptimized operation (represented as total fuel fired per MWh generated) •improve unit NOx emission rates 10%+ beyond static optimization baselines •improve unit temperature stability as much as 58% and on average 12% •improve operating load stability as much as 35% The culmination of this project has generated an advanced methodology of deploying specially designed recurrent neural networks (long short-term memory, gated recurrent unit, encoder-decoder networks, transformers, etc.), customized trajectory planning and closed-loop optimization modules capable of adapting to live electric grid responses and demands, self-tuning and adaptive expert controls constantly adjusting prediction parameters to real-time unit behavior, and a hardware/software package able to reliably calculate net unit heat rate (NUHR) in real-time using flue gas constituents, machine learning, and known combustion relationships. Through this real-time NUHR value, immediate feedback on system adjustments relative to operating efficiency was available, allowing for rapid improvements to system performance. In addition to development and deployment of the advanced D-NNO system, the approach methodology has been readily commercialized through the project platform Griffin Open Systems, LLC, the D-NNO software platform host. Similar methodologies to those developed by this project have already been deployed at 5 other units across the United States, with another 6 implementations scheduled, and more expected. Over the course of the project, multiple academic papers were submitted and accepted for publication within esteemed academic journals, and PhD students were trained and graduated, as well as undergraduate students becoming involved and participating to project objectives.

01 COAL, LIGNITE, AND PEAT↗