Swept-slot film-cooling effectiveness in hypersonic turbulent flow

Measurement results are presented for the surface equilibrium temperature downstream of swept slots, with sonic tangential air injection into a thick hypersonic turbulent boundary layer. These results are compared with unswept slot results for cooling effectiveness.

Hefner, J. N.↗

A two-dimensional cascade solution using minimized surface singularity density distributions - with application to film cooled turbine blades

An investigation of the effects of coolant injection on the aerodynamic performance of cooled turbine blades is presented. The coolant injection is modeled in the inviscid irrotational adiabatic flow analysis through the cascade using the distributed singularities approach. The resulting integral equations are solved using a minimized surface singularity density criteria. The aerodynamic performance was evaluated using this solution in conjunction with an existing mixing theory analysis. The results of the present analysis are compared with experimental measurements in cold flow tests.

Mcfarland, E.↗

Two-dimensional cold-air cascade study of a film-cooled turbine stator blade. 5: Comparison of experimental and analytical aerodynamic results for blade with 12 rows of 0.038-centimeter-(0.015 inch) diameter coolant holes having streamwise ejection angles

Published experimental aerodynamic efficiency results were compared with results predicted from two published analytical methods. This is the second of two such comparisons. One of the analytical methods was used as published; the other was modified for certain cases of coolant discharge from the blade suction surface. The results show that for 23 cases of single row and multirow discharge covering coolant fractions from 0 to about 9 percent, the difference between the experimental and predicted results was no greater than about 1 percent in any case and less than 1/2 percent in most cases.

Prust, H. W., Jr.↗

A computer program for full-coverage film-cooled blading analysis including the effects of a thermal barrier coating

The program input, coolant flow and heat transfer model, and the program output are discussed. As an example, sections of the suction and pressure sides of a high temperature, high pressure turbine vane are analyzed to show the effects of a thermal barrier coating. Compared to the uncoated design, the coating halves the required coolant flow, while simultaneously reducing metal outer temperatures by over 111 K.

Source record↗

Full-coverage film cooling: 3-dimensional measurements of turbulence structure and prediction of recovery region hydrodynamics

Hydrodynamic measurements were made with a triaxial hot-wire in the full-coverage region and the recovery region following an array of injection holes inclined downstream, at 30 degrees to the surface. The data were taken under isothermal conditions at ambient temperature and pressure for two blowing ratios: M = 0.9 and M = 0.4. Profiles of the three main velocity components and the six Reynolds stresses were obtained at several spanwise positions at each of the five locations down the test plate. A one-equation model of turbulence (using turbulent kinetic energy with an algebraic mixing length) was used in a two-dimensional computer program to predict the mean velocity and turbulent kinetic energy profiles in the recovery region. A new real-time hotwire scheme was developed to make measurements in the three-dimensional turbulent boundary layer over the full-coverage surface.

Yavuzkurt, S.↗

Full-coverage film cooling. I - Three-dimensional measurements of turbulence structure. II - Prediction of the recovery-region hydrodynamics

Hydrodynamic measurements of turbulence structure were performed with a triaxial hot wire in the full coverage and the recovery regions following an array of injection holes under isothermal conditions at ambient temperature and pressure for blowing ratios of 0.9 and 0.4. High levels of turbulence kinetic energy (TKE) were determined for low blowing, and low TKE levels were found for the high blowing levels; in the recovery region, the flow can be represented by a model with an outer boundary layer and a 2-dimensional inner boundary layer. Recovery region hydrodynamics can be modelled by considering that a new boundary layer started to grow immediately after the end of blowing; the Prandtl mixing length distributions calculated from the values of mean velocity and turbulent shear stresses were consistent with the presence of a dual boundary layer structure in the recovery region. The program used here contains a one-equation model of turbulence, using turbulence kinetic energy with an algebraic mixing length; this 2-dimensional, finite difference program can predict the mean velocity and turbulence kinetic energy profiles based on initial values, boundary conditions, and a closure condition.

Yavuzkurt, S.↗

Full-coverage film cooling

Transpiration cooling is treated and then full coverage discrete hole injection for three injection orientations. Spacings with pitch to diameter ratios of 5 and 10 are discussed. The array is staggered, with the transverse pitch and the streamwise pitch the same. Results are presented in terms of the Stanton number using the heat transfer coefficient defined in terms of the difference between the wall temperature and the free stream temperature. Two values of Stanton number are provided for each situation: one with the injectant at wall temperature, and the other with the injectant at free stream temperature. These two values are equivalent to knowing the heat transfer coefficient and the adiabatic effectiveness. The heat transfer coefficient thus defined is used with the actual wall temperature to and the actual gas temperature to calculate the heat load. The principle of superposition thus invoked is valid exactly when the governing equations are linear.

Moffat, R. J.↗

Heat transfer and turbulence measurements of a film-cooled flow over a convexly curved surface

Heat transfer and hydrodynamic boundary layer measurements were made in a turbulent boundary layer on a convex surface with 13 rows of injection. Both full- and partial-coverage cases were tested for three blowing ratios: 0.2, 0.4, and 0.6. Heat transfer results are discussed in terms of Stanton number with injection air temperature equal to wall temperature. In the blown region, for both m (blowing ratio) = 0.2 and 0.4, the local response of the boundary layer is dominated by curvature, and m = 0.4 shows higher cooling effects than m = 0.2 or 0.6, as expected, based on flat-plate results. Hydrodynamic measurements with a triple-hot-wire suggest the existence of two streamwise lanes. Lanes containing injection holes are highly affected by injection and show a definite streamwise evolution. Lanes which do not contain holes are not affected much by injection and show little change in the streamwise direction.

Furuhama, K.↗

Development of computer models for correlating data of film cooling of nose cone under hypersonic flow

A 12.5 degree half cone with tangential slot injection at Mach 6.95 was studied to determine the heating rates to the surface of the body near and far downstream of the slot. The cone had a zero degree angle of attack. The heating rates were obtained using a computer program that was developed at NASA-Langley Research Center. The concentration of nitrogen from the slot into the boundary layer was also determined. The ratio of slot to freestream was varied to determine its effect on heating. The numerical heating rates were compared to other correlations obtained from experimental studies as well as theoretical laminar and turbulent results.

Sharpe, L., Jr.↗

Film cooling heat transfer on a turbine airfoil

The objectives of the current program are to develop an analytical approach, based on boundary layer theory, for predicting the effects of airfoil cooling on downstream heat transfer rates and to verify the resulting analytical method by comparison of predictions with hot cascade data obtained under this program.

Hylton, Larry D.↗

Gas-jet and tangent-slot film cooling tests of a 12.5 deg cone at Mach number of 6.7

Tests were conducted in the Langley 8-Foot High Temperature Tunnel to determine the aerothermal effects of gaseous nitrogen-coolant ejection on a 3-ft base-diameter, 12.5 degree half-angle cone. Free-stream Mach number, total temperature, and unit Reynolds number per foot were 6.7, 3300 deg R, and 1.4 million, respectively. Two coolant ejection noses were tested, an ogive frustum with a forward-facing 0.8-in radius gas-jet tip, and a 3-in radius hemisphere with a 0.243-in high rearward-facing tangent slot. Data include surface pressures and heating rates, shock shapes, and shock-layer profiles; results are compared with no-cooling data obtained with 1-in and 3-in radius solid noses. Surface pressures were reduced with gas-jet ejection but were affected little by tangent-slot ejection. For both gas-jet and tangent-slot ejection, high coolant flow rates reduced heating even far downstream from the region of ejection; however, low coolant rates caused transition to turbulence and increased heating. Shock-layer profiles of pitot pressure, Mach number, and total temperature were reduced for both gas-jet and tangent-slot ejection. Insight into the gas-jet heat-flux mechanisms was obtained by using shock-layer rake data and established, no-cooling, heat-transfer equations.

Nowak, Robert J.↗

Assessment of the NASA code FDNS2D for computation of film cooling effectiveness

The role of computational fluid dynamics (CFD) programs is usually one of analysis. Generally they are not used in the design phase of a project. There was an effort to integrate CFD codes into the design phase of combustion devices, specifically, in the design of the Space Transportation Main Engine (STME) nozzle. Before the results of such analyses can be accepted, the credibility of the CFD codes upon which they are based must be established. The effort to assess the capability of the NASA code FDNS2D to compute the heat transfer to a solid bounding surface is detailed. Specifically, high speed flow over a flat plate is considered, and the resulting wall shear stress, and heat transfer are computed. These values are compared against analytical results (for wall shear stress) and experimental data (for heat transfer). A brief description is given of the FDNS2D code, with special emphasis on how it handles solid wall boundary conditions. The flow conditions and the FDNS solution are presented, along with comparison to analytical and experimental data. Some intermediate observations are then made, followed by a recommendation for adoption of an alternate method for computing the wall heat flux.

Woodbury, Keith A.↗

Heat flux sensor research and development: The cool film calorimeter

The goal was to meet the measurement requirement of the NASP program for a gauge capable of measuring heat flux into a 'typical' structure in a 'typical' hypersonic flight environment. A device is conceptually described that has fast response times and is small enough to fit in leading edge or cowl lip structures. The device relies heavily on thin film technology. The main conclusion is the description of the limitations of thin film technology both in the art of fabrication and in the assumption that thin films have the same material properties as the original bulk material. Three gauges were designed and fabricated. Thin film deposition processes were evaluated. The effect of different thin film materials on the performance and fabrication of the gauge was studied. The gauges were tested in an arcjet facility. Survivability and accuracy were determined under various hostile environment conditions.

Abtahi, A.↗