Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Failure Diameter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Notch insensitivity in fatigue failure of chopped carbon fiber chip-reinforced composites using experimental and computational analysis

This study focuses on the notch effect on the fatigue failure of chopped carbon fiber chip-reinforced sheet molding compound (SMC) composites by using both experimental and numerical methods. The S-N diagrams of notched specimens are first obtained experimentally, which exhibit large scatter and are shown to depend on the spatial distribution of local fiber orientations. After considering the effect of this spatial distribution by adopting a new fatigue damage parameter to normalize the results, we achieve a much better correlation in the normalized S-N diagram for all the notched specimens with different hole diameters. Next, compared with the fatigue results of smooth specimens without notches, we find that SMC composites under tension-tension fatigue loading exhibit notch-insensitivity, which renders this type of composites a better candidate in joints or similar applications. Meanwhile, the fatigue failure mechanisms of notched SMC composites are explored through a microstructure characterization procedure. On this basis, a computational micromechanics model considering the notch effect and an improved multi-scale progressive damage fatigue law, calibrated by coupon-level fatigue tests of smooth SMC composites under different loading conditions, are employed to predict the fatigue behavior of notched SMC composites. We show that detailed failure processes and fatigue life of notched SMC composites can be efficiently and adequately predicted by this computational framework.

36 MATERIALS SCIENCE↗

Perineural Infiltration of Cutaneous Squamous Cell Carcinoma and Basal Cell Carcinoma Without Clinical Features

Purpose: To review the factors that influence outcome and patterns of relapse in patients with cutaneous squamous cell carcinoma (SCC) and basal cell carcinoma (BCC) with perineural infiltration (PNI) without clinical or radiologic features, treated with surgery and radiotherapy. Methods and Materials: Between 1991 and 2004, 222 patients with SCC or BCC with PNI on pathologic examination but without clinical or radiologic PNI features were identified. Charts were reviewed retrospectively and relevant data collected. All patients were treated with curative intent; all had radiotherapy, and most had surgery. The primary endpoint was 5-year relapse-free survival from the time of diagnosis. Results: Patients with SCC did significantly worse than those with BCC (5-year relapse-free survival, 78% vs. 91%; p < 0.01). Squamous cell carcinoma with PNI at recurrence did significantly worse than de novo in terms of 5-year local failure (40% vs. 19%; p < 0.01) and regional relapse (29% vs. 5%; p < 0.01). Depth of invasion was also a significant factor. Of the PNI-specific factors for SCC, focal PNI did significantly better than more-extensive PNI, but involved nerve diameter or presence of PNI at the periphery of the tumor were not significant factors. Conclusions: Radiotherapy in conjunction with surgery offers an acceptable outcome for cutaneous SCC and BCC with PNI. This study suggests that focal PNI is not an adverse feature.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessment of Cold Spraying Mild-Steel Powder onto Mild-Steel Substrate for Development of Waste Tank Repair System - 20515

Infrastructure for nuclear waste storage and processing (e.g., waste tanks, transfer pipelines, evaporators) at the U.S. Department of Energy (DOE) Hanford Site has been in service well beyond its original design life. Past corrosion control methods at Hanford for waste tanks have not been fully successful, as evidenced by leaks forming in tank AY-102, the first double-shell tank (DST) constructed, and significant degradation detected in the primary tanks of AP-102 and AY-101. Failure of infrastructure components can pose a significant risk to the environment, worker safety, and project schedules. Therefore, remotely deployable methods for repairing and extending the service life of the existing tank waste infrastructure are needed. Cold spray has been identified as a potential technique for performing in situ repairs and material buildup for life extension of waste storage and processing infrastructure. Cold-spray repair methods and technology are well-established and are used extensively by industry and the military for making repairs using dissimilar materials. Pacific Northwest National Laboratory is evaluating the process of making repairs using mild-steel powder applied to a mild-steel substrate to minimize the galvanic corrosion potential. This paper presents the initial results for a feasibility ('go/no-go') assessment as to whether low-density deposits with sound metallurgic bonds, to build-back steel plate material, can be achieved using existing commercial cold-spray equipment. An assessment of steel-on-steel deposit is necessary to determine if cold spray is a viable candidate for DST carbon steel plate restoration/repair and thus DST service life extension. Powder properties and preparation requirements have been investigated and operating conditions and parameters for depositing a cold-spray buildup of mild steel on a mild-steel substrate have been determined. Soundness of metallurgic bonding as a function of the operating parameters exercised and results from applying cold spray to lay a deposit over simulated small-diameter flaws in 1/2-inch mild-steel plate are presented. Application of in situ cold-spray repair to the DOE complex has the potential to reduce cost and schedule impacts associated with component failures and the need to procure and construct replacement infrastructure. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Material Open Test Assembly Specimen Retrieval from Hanford's Shielded Material Facility

Hanford’s 324 Building, the Shielded Material Facility (SMF), was developed to provide containment for research and fabrication development studies on highly radioactive metallic and ceramic nuclear reactor fuels and structural materials. Between 1983 and 1992, the SMF was used in support of the Department of Energy (DOE)-funded Fast Flux Test Facility (FFTF) Materials Open Test Assembly (MOTA) program. In this program, metallurgical specimens were irradiated in FFTF and then sent to SMF for processing and storage in two cabinets. This effort was abruptly ended in early 1990s due to programmatic shifts within the DOE, leaving many specimens unexamined. In recent years, these specimens have become of high value to new DOE programs. Pacific Northwest National Laboratory (PNNL) was tasked with retrieving specimens from one of the cabinets in support of fuel clad and duct development for the Advanced Fuel Cycle Initiative. Cesium contamination of the cell and failure of the overhead crane system utilized for opening the cabinets prevented PNNL from using the built-in hot cell equipment to gain access to the cabinets. PNNL designed and tested a lifting device to fit through a standard 10 inch diameter mechanical manipulator port in the SMF South Cell wall. The tool was successfully deployed in June 2008 with the support of Washington Closure Hanford.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Defective rapid cell shape and transendothelial migration by calpain-1 null neutrophils

Highlights: • The role of calpain-1 in neutrophil shape change was investigated. • Neutrophils were obtained from knock-out mice and assessed ex vivo. • These cells failed to migrate through endothelial monolayers. • Spontaneous cell spreading was grossly abberant. • Calpain-1 null cells failed to spread in response to IP{sub 3} -induced Ca{sup 2+} signals. It has been proposed that Ca{sup 2+} activation of calpain-1 is an important trigger for rapid cell spreading by neutrophils. In this paper, we have investigated this by assessing the ex vivo functioning of neutrophils from calpain-1 null mice, Calpain-1 null neutrophils failed to migrate through TNF-activated endothelial monolayers. The failure to transmigrate through endothelial monolayers was therefore unlikely to be due to a failure of chemotaxis as chemotaxis by adherent calpain-1 null neutrophils towards fMLP was unpaired. In contrast, the capacity of calpian-1 neutrophils to spontaneously spread was limited to smaller diameters than for wild type cells. Photolytic uncaging of IP{sub 3} with Individual wild type neutrophils resulted in a large Ca{sup 2+} signal and rapid cell spreading. In contrast, calpain-1 neutrophils failed to spread in response to the IP{sub 3}-induced Ca{sup 2+} signal. This work has therefore demonstrated that the presence of calpain-1 was required for effective rapid cell spreading by neutrophils.

60 APPLIED LIFE SCIENCES↗

Mjölnir: a miniature triaxial rock deformation apparatus for 4D synchrotron X-ray microtomography

An X-ray transparent experimental triaxial rock deformation apparatus, here named 'Mjölnir', enables investigations of brittle-style rock deformation and failure, as well as coupled thermal, chemical and mechanical processes relevant to a range of Earth subsurface environments. Designed to operate with cylindrical samples up to 3.2 mm outside-diameter and up to 10 mm length, Mjölnir can attain up to 50 MPa confining pressure and in excess of 600 MPa axial load. The addition of heaters extends the experimental range to temperatures up to 140°C. Deployment of Mjolnir on synchrotron beamlines indicates that full 3D datasets may be acquired in a few seconds to a few minutes, meaning full 4D investigations of deformation processes can be undertaken. Mjölnir is constructed from readily available materials and components and complete technical drawings are included in the supporting information.

47 OTHER INSTRUMENTATION↗

Direct Subsurface Measurements through Precise Micro Drilling

Wellbore integrity is a significant problem in the U.S. and worldwide, which has serious adverse environmental and energy security consequences. Wells are constructed with a cement barrier designed to last about 50 years. Indirect measurements and models are commonly used to identify wellbore damage and leakage, often producing subjective and even erroneous results. The research presented herein focuses on new technologies to improve monitoring and detection of wellbore failures (leaks) by developing a multi-step machine learning approach to localize two types of thermal defects within a wellbore model, a prototype mechatronic system for automatically drilling small diameter holes of arbitrary depth to monitor the integrity of oil and gas wells in situ, and benchtop testing and analyses to support the development of an autonomous real-time diagnostic tool to enable sensor emplacement for monitoring wellbore integrity. Each technology was supported by experimental results. This research has provided tools to aid in the detection of wellbore leaks and significantly enhanced our understanding of the interaction between small-hole drilling and wellbore materials.

42 ENGINEERING↗

Solid rocket motor aft field joint flow field analysis

An efficient Navier-Stokes analysis was successfully applied to simulate the complex flow field in the vicinity of a slot in a solid rocket motor with segment joints. The capability of the computer code to resolve the flow near solid surfaces without using a wall function assumption was demonstrated. In view of the complex nature of the flow field in the vicinity of the slot, this approach is considered essential. The results obtained from these calculations provide valuable design information, which would otherwise be extremely difficult to obtain. The results of the axisymmetric calculations indicate the presence of a region of reversed axial flow at the aft-edge of the slot and show the over-pressure in the slot to be only about 10 psi. The results of the asymmetric calculations indicate that a pressure asymmetry more than two diameters downstream of the slot has no noticeable effect on the flow field in the slot. They also indicate that the circumferential pressure differential caused in the slot due to failure of a 15 deg section of the castable inhibitor will be approximately 1 psi.

Sabnis, Jayant S.↗

ANS MiNES 2023 Poster

The dynamic mechanical properties of four varieties of high purity graphite as well as the depth of penetration (DoP) of a small-scale shaped charge into these grades was experimentally determined. The grades chosen were PCEA, NBG-18, and NBG-25. These grades provide a wide range of physical properties: in density from 1.80 – 1.85 g/cc, in maximum particle size from 10s to 1000s of µm, and in porosity from 18% to 20%. The quasistatic and dynamic compressive strengths of each grade were determined and correlated to their physical properties. The split Hopkinson pressure bar experiments showed both the dynamic strength and dominant shear failure mechanisms. A small scale shaped charge was used to compare the resistance of graphite to hypervelocity jet impacts: the Teledyne RP-4. The RP-4 has a 1.01” outer diameter and 3.44 g of RDX with an RP-80 booster (86 mg PETN + 123 mg RDX). A select number of samples were analyzed using X-Ray Computed Tomography (XCT), allowing for the full characterization of the undisturbed wound channel. A selection of other samples were physically sectioned and wound channels mapped from the sections. In addition to DoP, the wound geometry was characterized in terms of total volume and diameter at different depths. The wound channel characteristics for each grade were correlated to the compressive strengths and physical properties. In several of the test samples, the wound channel diameter was smaller than the diameter of the shaped charge slug just behind where the slug had penetrated the sample. These results indicated that the wound geometry was dependent on the compressive hysteresis behavior of graphite.

36 MATERIALS SCIENCE↗

Real-time visualization of impact damage in monolithic silicon carbide and fibrous silicon carbide ceramic composite

Impact resistance from foreign debris is a critical requirement for brittle ceramic and ceramic composite materials intended for use in the hot-section of gas turbine engines. A design to mitigate against such impact failures necessitates a detailed understanding of the driving failure mechanisms. The present study introduces a unique time-resolved experimental method which advances the latter effort. Specifically, a pulsed synchrotron X-ray source, in phase contrast imaging (PCI) configuration, is used as a medium, to visually characterize the evolution of damage inside the target materials during impact. As a proof of concept, two types of ceramic materials were tested: monolithic silicon carbide and fibrous silicon carbide composite. Impact was performed using a light-gas gun and 1.5 mm diameter spheres of partially stabilized zirconia (PSZ) and silicon nitride (Si 3 N 4 ). The retrieved dynamic X-ray image sequences provided clear outlines of the damage features. In the case of the monolithic ceramic, the impact by a PSZ projectile initially produced a cone crack and complete failure resulted by extension of a median crack. By contrast, the fibrous composite deformed readily prior to cone crack formation. Nearly identical damage features were observed in the monolith for the Si 3 N 4 projectile, with the exception of the added vertical tensile crack. For this same projectile, the fibrous ceramic showed very limited surface deformation and enhanced cone cracking and kinking of laminates along the crack path. The latter response is attributed to the change in projectile properties. Some of the target materials were recovered, and post-mortem analysis via scanning electron microscopy (SEM) showed correlation with observed X-ray damage profiles. Furthermore, simple Hertzian contact was used to estimate damage for the elastic portion of impact. This approach was found to yield a reasonable match with experimental results for the surface displacement near the contact interface.

36 MATERIALS SCIENCE↗

Z-2 Threaded Insert Design and Testing

NASA's Z-2 prototype space suit contains several components fabricated from an advanced hybrid composite laminate consisting of IM10 carbon fiber and fiber glass. One requirement was to have removable, replaceable helicoil inserts to which other suit components would be fastened. An approach utilizing bonded in inserts with helicoils inside of them was implemented. During initial assembly, cracking sounds were heard followed by the lifting of one of the blind inserts out of its hole when the screws were torqued. A failure investigation was initiated to understand the mechanism of the failure. Ultimately, it was determined that the pre-tension caused by torqueing the fasteners is a much larger force than induced from the pressure loads of the suit which was not considered in the insert design. Bolt tension is determined by dividing the torque on the screw by a k value multiplied by the thread diameter of the bolt. The k value is a factor that accounts for friction in the system. A common value used for k for a non-lubricated screw is 0.2. The k value can go down by as much as 0.1 if the screw is lubricated which means for the same torque, a much larger tension could be placed on the bolt and insert. This paper summarizes the failure investigation that was performed to identify the root cause of the suit failure and details how the insert design was modified to resist a higher pull out tension.

Ross, Amy↗

Microstructural Effects on Creep-Fatigue Life of Alloy 709

Cyclic testing has been carried out to characterize the fatigue and creep-fatigue behavior of Alloy 709, an advanced austenitic structural alloy. Specimens were machined from several plates of 709, subjected to different processing conditions and resulting in varying microstructures in the specimens, dependent on both the plate used for the machining and the location the specimen originated from within the plate. The cyclic testing has been conducted primarily at a single fatigue and creep-fatigue condition, which was at 650 °C and 1.0% total strain (+/-0.5% strain). For creep-fatigue, a 30 min. hold time at peak tensile strain was introduced. The combined results of the cyclic testing and post-test metallographic characterization suggest that the investigated microstructures, ultimately controlled by the processing conditions, have limited influence on the Alloy 709 fatigue cycle life. In contrast, some effect on the creep-fatigue cycle life due to the microstructure was observed, specifically that the presence of large grains may negatively impact the creep-fatigue resistance. The number of cycles to failure at the selected creep-fatigue condition varied by up to a factor of 5 for the specimens tested. Specimens with an optimum microstructure, a uniform distribution of grains with diameters less than approximately 200 ?m, resulted in a creep-fatigue resistance similar to that of 316-type stainless steel. The majority of the Alloy 709 cyclic test data has been previously reported in milestone reports - and the microstructural and processing details for the specific heats have been reported by Yamamoto et al. - This summary report includes creep-fatigue test results on three additional heats (011502F, 011502H, and 011539 (note, same plate as ORNL 011593)) for which the processing and microstructural details are available in previous reports.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measurements and mechanisms of localized aqueous corrosion in aluminum-lithium-copper alloys

Summary information is included for electrochemical aspects of stress corrosion cracking in alloy 2090 and an introduction to the work to be initiated on the new X2095 (Weldalite) alloy system. Stress corrosion cracking (SCC) was studied in both S-T and L-T orientations in alloy 2090. A constant load TTF test was performed in several environments with a potentiostatically applied potential. In the same environments the electrochemical behavior of phases found along subgrain boundaries was assessed. It was found that rapid failure due to SCC occurred when the following criteria was met: E(sub BR,T1) is less than E(sub applied) is less than E(sub Br, matrix phase). Although the L-T orientation is usually considered more resistant to SCC, failures in this orientation occurred when the stated criteria was met. This may be due to the relatively isotropic geometry of the subgrains which measure approximately 12 to 25 microns in diameters. Initial studies of alloy X2095 includes electrochemical characterization of three compositional variations each at three temperatures. The role of T(sub 1) dissolution in SCC behavior is addressed using techniques similar to those used in the research of 2090 described. SCC susceptibility is also studied using alternate immersion facilities at Reynolds Metals Corporation. Pitting is investigated in terms of stability, role of precipitate phases and constituent particles, and as initiation sites for SCC. In all research endeavors, attempts are made to link electrochemistry to microstructure. Previous work on 2090 provides a convenient basis for comparison since both alloys contain T(sub 1) precipitates but with different distributions. In 2090 T(sub 1) forms preferentially on subgrain boundaries whereas in X2095 the microstructure appears to be more homogeneous with finer T(sub 1) particles. Another point for comparison is the delta prime strengthening phase found in 2090 but absent in X2095.

Wall, Douglas↗

Interfacial shear behavior of sapphire-reinforced NiAl composites

The interfacial shear behavior in near-equiatomic NiAl reinforced by sapphire filaments has been examined at room temperature using a fiber pushout test technique. The load-displacement data indicate a large variability in the initial interface failure stress, although reverse push behavior indicates a comparatively constant interfacial sliding friction stress. The observed behavior suggests that the presence of asperities on the fiber surfaces and nonuniformities in fiber diameter require constrained plastic flow within the NiAl matrix in order for interfacial shear to occur. The location, shape, severity, and distribution of fiber asperities as well as the uniformity of fiber diameter are critical to the interfacial shear process.

Moose, C. A.↗

A New Local Failure Model with Application to the Longitudinal Tensile Behavior of Continuously Reinforced Titanium Composites

A new model for local fiber failures in composite materials loaded longitudinally is presented. In developing the model, the goal was to account for the effects of fiber breakage on the global response of a composite in a relatively simple and efficient manner. Towards this end, the model includes the important feature of local stress unloading, even as global loading of the composite continues. The model has been incorporated into NASA Glenn's Micromechanics Analysis Code with Generalized Method of Cells (MAC/GMC) and was employed to simulate the longitudinal tensile deformation and failure behavior of several silicon carbide fiber/titanium matrix (SiC/Ti) composites. The model is shown to be quite realistic and capable of accurate predictions for various temperatures, fiber volume fractions, and fiber diameters. Further- more, the new model compares favorably to Curtin's (1993) effective fiber breakage model, which has also been incorporated into MAC/GMC.

Bednarcyk, Brett A.↗

Surface fatigue life and failure characteristics of EX-53, CBS 1000M, and AISI 9310 gear materials

Spur gear endurance tests and rolling-element surface fatigue tests are conducted to investigate EX-53 and CBS 1000M steels for use as advanced application gear materials, to determine their endurance characteristics, and to compare the results with the standard AISI 9310 gear material. The gear pitch diameter is 8.89 cm (3.50 in). Gear test conditions are an oil inlet temperature of 320 K (116 F), an oil outlet temperature of 350 K (170 F), a maximum Hertz stress of 1.71 GPa (248 ksi), and a speed of 10,000 rpm. Bench-type rolling-element fatigue tests are conducted at ambient temperature with a bar specimen speed of 12,500 rpm and a maximum Hertz stress of 4.83 GPa (700 ksi). The EX-53 test gears have a surface fatigue life of twice that of the AISI 9310 spur gears. The CBS 1000M test gears have a surface fatigue life of more than twice that of the AISI 9310 spur gears. However, the CBS 1000M gears experience a 30-percent tooth fracture failure which limits its use as a gear material. The rolling-contact fatigue lines of RC bar specimens of EX-53 and ASISI 9310 are approximately equal. However, the CBS 1000M RC specimens have a surface fatigue life of about 50 percent that of the AISI 9310.

Townsend, D. P.↗

Exact solutions of burst pressure for thick-walled cylinders in power-law strain hardening steels

Exact solutions of burst pressure for defect-free, thick-walled cylindrical pressure vessels with capped ends are developed using the flow theory of plasticity in terms of the Tresca, von Mises, and Zhu-Leis yield criteria. The material is assumed to obey a power-law strain hardening rule, and the finite strain theory is adopted to describe large plastic deformation. On this basis, internal pressure is obtained as a complex polynomial function of effective strains on the inside and outside surfaces of the pressure vessel with the use of the Bernoulli numbers. At burst failure, the effective strains and stresses on the inside and outside surfaces are first determined, and then three flow solutions of burst pressure are obtained as a power series function of the diameter ratio (D o /D i ), strain hardening exponent (n), and ultimate tensile strength (UTS). The power series solution is confirmed to agree well with the exact flow solution of burst pressure in a closed-form for each yield criterion, and the results show that the von Mises flow solution is an upper bound prediction, the Tresca flow solution is a lower bound prediction, and the Zhu-Leis flow solution is an intermediate prediction of burst pressure. In conclusion, two sets of full-scale burst test data are then utilized to evaluate and validate the proposed flow solutions of burst pressure for both thin-walled pipes and thick-walled cylindrical pressure vessels.

36 MATERIALS SCIENCE↗

Ultrahigh elastically compressible and strain-engineerable intermetallic compounds under uniaxial mechanical loading

Intermetallic compounds possess unique atomic arrangements that often lead to exceptional material properties, but their extreme brittleness usually causes fracture at a limited strain of less than 1% and prevents their practical use. Thus, it is critical for them to exhibit either plasticity or some form of structural transition to absorb and release a sufficient amount of mechanical energy before failure occurs. This study observes that the ThCr 2 Si 2 -structured intermetallic compound (CaFe 2 As 2 ) and a hybrid of its structure (CaKFe 4 As 4 ) with 2 μm in diameter and 6 μm in height can exhibit superelasticity with strain up to 17% through a reversible, deformation-induced lattice collapse, leading to a modulus of resilience orders of magnitude higher than that of most engineering materials. Such superelasticity also can enable strain engineering, which refers to the modification of material properties through elastic strain. Density functional theory calculations and cryogenic nanomechanical tests predict that superconductivity in CaKFe 4 As 4 could be turned on/off through the superelasticity process, before fracture occurs, even under uniaxial compression, which is the favorable switching loading mode in most engineering applications. Our results suggest that other members with the same crystal structure (more than 2500 intermetallic compounds) and substitution series based on them should be examined for the possibility of manifesting similar superelastic and strain-engineerable functional properties.

36 MATERIALS SCIENCE↗