Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FREQUENCY SYNCHRONIZATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

On the spectral behaviour of the turbulence-driven power fluctuations of horizontal-axis turbines

In this article we consider the spectral behaviour of turbulence-driven power fluctuations for a single horizontal-axis turbine. To this end, a small-scale instrumented axial-flow hydrokinetic turbine model ( diameter=0.724 m ) is deployed in the long water flume situated in the laboratory facilities of IFREMER in Boulogne-sur-Mer, France, and synchronous measurements of the upstream velocity and the rotor are collected for different tip-speed ratios. The study confirms previous findings suggesting that the power spectra follow the velocity spectra behaviour in the large scales region and a steeper power law slope behaviour ( -11/3 ) over the inertial frequency sub-range. However, we show that both the amplitude of the power spectra and low-pass filtering effect over the inertial sub-range also depend on the rotor aero/hydrodynamics (e.g. dC L /dα) and the approaching flow deceleration and not solely on the rotational effects. In addition, we present a novel semi-analytical model to predict the dominant blade-passing frequency harmonics in the high-frequency regime using the rotationally sampled spectra technique. For all calculations, the distortion of incoming turbulence is taken into account.

42 ENGINEERING↗

PMU-data-driven Event Classification in Power Transmission Grids

This paper presents an event classification in transmission grids. The convolutional neural network (CNN)-based classifier is proposed to capture the temporal similarity of time-synchronized data stream from phasor measurement units (PMUs). The proposed CNN is trained using Bayesian optimization to search for the best hyperparameters. The effectiveness of the proposed event classification is validated through the real-world dataset from the U.S. transmission grids. This dataset includes line outage, transformer outage, frequency, and oscillation events. The validation process also includes different PMU outputs, such as voltage magnitude, phase angle, current magnitude, frequency, and rate of change of frequency (ROCOF). The results show that ROCOF gives the best classification performance compared to other PMU outputs. In addition, it is shown that the classifier trained with a larger dataset has higher accuracy. Moreover, the superiority of the proposed method is validated through comparison with other state-of-the-art classification methods.

Niazazari, Iman↗

Impact of Aggregated PV on Subsynchronous Torsional Interaction: Preprint

This paper investigates induced oscillation (specifically subsynchronous torsional interactions) in power systems arising from photovoltaic (PV) power modulation. Time domain simulations of a modified IEEE first-benchmark system are presented and analyzed. In the IEEE benchmark system, a PV generator was added at the same bus where the synchronous generator is connected. The impact of different parameters of the PV inverters volt-volt-ampere reactive (volt-var) curve on SSTI is examined. The most severe impact found arises from the time response of the inverters reactive power change. A second-order time response with natural frequency matching the rotor speed deviation oscillation frequency and low-damping ratio quickly drives the system to an unstable region. Although it is highly unlikely that conditions necessary for distributed energy resource-induced oscillations would occur in the field, with knowledge of this vulnerability in mind, inverters' control parameters can be designed to avoid it.

aggregated↗

WBG-Enabled Current-Source Inverters for Integrated PM Motor Drives

This project takes advantage of the special capabilities of wide-bandgap (WBG) power semiconductor devices to develop innovative power electronics in the form of new current-source inverters (CSIs) that offer promising advantages over the dominant voltage-source inverter (VSI) topology. These CSIs, in turn, are extremely well-suited for integration into the housings of permanent magnet synchronous machines (PMSMs) to form integrated motor drives (IMDs). These new IMDs offer great promise for achieving major energy savings in a wide variety of applications that benefit from adjustable-speed control, including air conditioners, laundry appliances, industrial pumps/compressors, electric vehicles, and aerospace drives. WBG devices play a critical enabling role in these new IMDs because of their transformative features including much higher switching frequencies, lower losses, and compatibility with high operating temperatures. When incorporated into new CSI-based IMDs with PM machines, these WBG switches open the door to achieving major increases in power density, drive system efficiency, and fault tolerance, as well as substantial reductions in electromagnetic interference (EMI), manufacturing cost, and temperature-induced failures. The higher operating temperature capability of WBG devices compared to conventional silicon power devices is very appealing in IMD applications because the power electronics is mounted in close proximity to the motors which typically operate at temperatures well above the maximum limits of today’s silicon-based power electronics. This project has succeeded in designing, building, and testing multiple prototype versions of this CSI-IMD that have overcome many technical challenges in order to demonstrate the impressive performance improvements that can be achieved by the WBG-enabled CSI-IMD. The preliminary demo and bench-top versions of the current-source inverter developed during the first two years of the project were critical to laying the technical foundations for the 3 kW prototype CSI-IMD unit that was successfully built and tested during the third year. This prototype CSI-IMD unit was designed to fit within the housing envelope of the original permanent magnet (PM) synchronous machine in order to meet the demanding power density requirements that were set at the beginning of the project. All of the remaining performance objectives set for the prototype CSI-IMD unit including efficiency and electromagnetic interference (EMI) were also met. The last 18 months of the project were devoted to developing further enhancements of the WBG-enabled CSI-IMD technology that better prepare it for commercial production. More specifically, an upgraded version of the prototype CSI-IMD unit was developed that moved the power electronics into the same machine housing chamber as the motor, substantially raising the thermal demands on the power electronics. Tests with five different combinations of motor enclosure types and air cooling configurations were evaluated. Importantly, this work confirmed that the power electronics can deliver its full rated power and still operate well within its maximum temperature limits even for worst-case conditions when the housing is “totally-enclosed” without any openings for air to enter or exit the enclosure, and no blower/fan is provided to blow air over the outside surface of the enclosure. Reaching the full performance and energy-savings potential of this disruptive CSI-IMD motor drive technology is highly consistent with ARPA-E’s stated mission to “enhance the economic and energy security of the United States” while also supporting its commitment to “ensure that the U.S. maintains a technological lead in developing and deploying advanced energy technologies”. Follow-on projects are under way to explore the scalability of WBG-enabled CSI-IMD technology to 100 kW (peak) electric vehicle traction drives and fault-tolerant modular motor drives for future electrified aircraft propulsion applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact of Aggregated PV on Subsynchronous Torsional Interaction

This paper investigates induced oscillation (specifically subsynchronous torsional interactions) in power systems arising from photovoltaic (PV) power modulation. Time domain simulations of a modified IEEE first-benchmark system are presented and analyzed. In the IEEE benchmark system, a PV generator was added at the same bus where the synchronous generator is connected. The impact of different parameters of the PV inverters’ volt-volt-ampere reactive (volt-var) curve on SSTI is examined. The most severe impact found arises from the time response of the inverter’s reactive power change. A second-order time response with natural frequency matching the rotor speed deviation oscillation frequency and low-damping ratio quickly drives the system to an unstable region. Although it is highly unlikely that conditions necessary for distributed energy resource-induced oscillations would occur in the field, with knowledge of this vulnerability in mind, inverters' control parameters can be designed to avoid it.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Probing-Based Inertia Estimation Method Using Hybrid Power Plants

With the displacement of synchronous generation by inverter-based resources (IBRs), power systems could face the challenge of reduced inertia since IBRs do not inherently contribute to system inertia. Therefore, there is rising interest in monitoring system inertia in real-time applications for situational awareness. In addition, there is a growing number of IBRs that provide fast frequency responses (FFR) in the form of synthetic inertia and P-f droop. It is desirable to quantify the contribution of these FFR controls as equivalent inertia. This paper proposes a probing-based inertia estimation method using a PV-battery hybrid power plant in the Kauai island power system. The method is validated under different operating conditions.

hybrid power plant↗

Robust Decentralized Secondary Control Scheme for Inverter-based Power Networks

Inverter-dominated microgrids are quickly becoming a key building block of future power systems. They rely on centralized controllers that can provide reliability and resiliency in extreme events. Nonetheless, communication failures due to cyber-physical attacks or natural disasters can make autonomous operation of islanded microgrids challenging. This paper examines a unified decentralized secondary control scheme that is robust to inverter clock synchronization errors and can be seamlessly applied to grid-following or grid-forming control architectures. The proposed scheme overcomes the well-known stability problem that arises from parallel operation of local integral controllers. Theoretical guarantees for stability are provided along with criteria to appropriately tune the secondary control gains to achieve good frequency regulation performance while ensuring fair power sharing. The efficacy of our approach is demonstrated through simulations on a 5-bus microgrid with four grid-forming inverters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Short pulsewidth high repetition rate nanosecond transient absorption spectrometer

A high-sensitivity nanosecond to millisecond transient absorption spectrometer for measurements of miniscule signals under low excitation intensities includes an excitation source generating a >100 Hz, <5 ns pulsewidth excitation pulse for exciting a light absorbing sample, a probe light source for generating a high photon flux probe light beam producing an average irradiance greater than 1 μW m-2 nm-1 for measuring the transient absorption spectrum of the sample before and after excitation by the excitation source, a DC-coupled detector capable of measuring light for enabling synchronous measurement of both the transmission of the probe light beam and the change in transmission of the probe light beam between a signal with the excitation pulse present and a signal in the absence of the excitation pulse, and a digital oscilloscope with a trigger rearm time capable of collecting every trigger event at frequencies including 1MHz, for enabling sequential noise subtraction protocols.

Rimshaw, Adam↗

Parametric Comparative Analysis between Virtual Synchronous Generator and Droop-based Inertia for Inverter-Based Microgrids

This paper presents a parametric comparative analysis between the virtual synchronous generator (VSG) method and the droop control method to emulate inertia in the voltage-source inverter (VSI). Droop controllers are commonly used to regulate sharing power in microgrids and distribute power generation proportionally among VSI’s depending on their rated power. Additionally, VSG has been used to regulate the Rate-of-Change-of-Frequency (RoCoF) of the microgrid using virtual inertia. Although both methods can be used to regulate the frequency variation, the influence of each method on the closed loop eigenvalues is not the same. In this work, the transient response of the frequency is analyzed for each method to determine their advantages and disadvantages regarding frequency regulation in microgrid applications. The results were verified by conducting experimental trials using VSI’s. These experiments demonstrated that VSG is more suitable for regulating RoCoF and frequency nadir than droop controllers since it provides inertial support and improves frequency response.

Campo-Ossa, Daniel D.↗

Use of a non-collinear wave mixing technique to image internal microscale damage in concrete

This research demonstrates the feasibility of using a non-collinear wave mixing technique to image internal microscale damage throughout the interior volume of a relatively large (28 cm thick) concrete component. By exploiting the underlying mechanics of nonlinear wave mixing, it is possible to mix two incident waves with frequencies low enough to propagate without being scattered by the inherently heterogenous, concrete microstructure, while still being sensitive to damage features with length scales well below these incident wavelengths. For this study, scanning and imaging is accomplished by manually adjusting the locations of the two incident waves, while a knowledge of the wave speeds in concrete plus synchronization identifies the location of the mixing zone—the specific volume of concrete being imaged. The viability of the proposed technique is demonstrated by examining a concrete prism specimen with known, embedded internal microscale damage.

Kim, Jin-Yeon (ORCID:0000000255180032)↗

Synchronized Phasor Measurement Unit-based Central Controller for Normal and Contingent Operation of a High-Capacity HVDC Macrogrid for the Continental US

This paper presents a Synchronized Phasor Measurement Unit (PMU) based controller to support the coordination and operation of a high-capacity high-voltage direct current (HVDC) macrogrid transmission for the continental US. The proposed controller allows for optimal scheduling of each segment of the multi-terminal HVDC network under normal and contingent conditions, while considering minimum levels of frequency response requirements. The performance of the proposed controller is tested on a 100,222-bus representation of the US Eastern and Western interconnections. Results show that a centralized PMU-based controller improves the frequency nadir of the HVDC macrogrid under contingency conditions by 25.9%. Furthermore, the primary frequency response (PFR) of the HVDC macrogrid is increased by 33.4%. The performance of each interconnection under the largest credible contingency conditions is also discussed.

Mohan, Nihal↗

Large-Scale Adoption of Self-Synchronized Universal Droop Controller-Based Inverters to Enable Ancillary Services for Different Modes of Distribution System Operations

This work proposes the large-scale adoption of self-synchronized universal droop controller (SUDC)-based inverters to enable ancillary services for different modes of distribution system operations. The IEEE 123 bus system was modeled on a real-time simulator to study the performance of large-scale adoption of SUDC inverters in a distribution system. The resulting data collected shows that the voltage and the frequency were regulated within ranges, such as less than 5% for voltage and less than 0.5% for frequency, under different load variations and grid operations. Also, the black start was achieved within 0.4 s without any voltage overshoot. Through the simulation and validation on a small microgrid and the IEEE 123 bus distribution system, it can be concluded that the SUDC was successfully adopted to regulate the voltage and the frequency within the given ranges, and black start achieved within 1 s without voltage overshoot for different modes of distribution system operations.

14 SOLAR ENERGY↗

Broad band tunable energy electron beam pulser

An electromagnetic mechanical pulser implements a transverse wave metallic comb stripline TWMCS kicker having inwardly opposing teeth that retards a phase velocity of an RF traveling wave to match the kinetic velocity of a continuous electron beam, causing the beam to oscillate before being chopped into pulses by an aperture. The RF phase velocity is substantially independent of RF frequency and amplitude, thereby enabling independent tuning of the electron pulse widths and repetition rate. The TWMCS further comprises an electron pulse picker (EPP) that applies a pulsed transverse electric field across the TWMCS to deflect electrons out of the beam, allowing only selected electrons and/or groups of electrons to pass through. The EPP pulses can be synchronized with the RF traveling wave and/or with a pumping trigger of a transverse electron microscope (TEM), for example to obtain dynamic TEM images in real time.

42 ENGINEERING↗

Wound Field and Hybrid Synchronous Machines for EV Traction with Brushless Capacitive Rotor Field Excitation (Final Report)

This project focused on the development of wound field synchronous machines (WFSMs) and hybrid excitation synchronous machines (HESMs) with brushless capacitive power transfer for the field excitation. The target application for the machines developed is the main traction motor in electric vehicles. The magnetization in these types of machines is provided by a field winding on the rotor which is excited with DC current. The magnetization level in the machine can be varied by changing the magnitude of the field current. The variable magnetization or field is one of the key features of WFSMs. WFSMs are commonly used as generators however they have several attractive features for automotive traction applications. 1) No use of permanent magnet: Rare earth permanent magnets are primarily mined and processed in China. They have been subject to large price and supply variations and their export may be restricted during times of geopolitical tension. 2) Easy field weakening: Wound field synchronous machines have complete control of their field excitation. With proper design, this type of machine can electromagnetically have an infinite constant power speed range. 3) High power factor: With proper choice of the field excitation, WFSMs may be operated with high or even unity power factor. This potentially allows for the inverter connected to the stator winding to be downsized. In comparison induction machines and interior permanent magnet synchronous machines must supply reactive power to the stator increasing the kVA rating and cost of the inverter. 4) Reduced iron losses at high speed: By reducing the field excitation, the iron loss in the stator can be reduced. This is in comparison to interior permanent magnet synchronous machines which must use stator current to buck or reduce the flux produced by the permanent magnets. Generally, WFSMs have their highest efficiency at high speed. 5) Torque output at high temperatures: The magnetization provided by the field winding only depends on the field current and not on the field winding temperature. This is in contrast to permanent magnet machines where the permanent magnet flux decreases as the magnet temperature increases. Historically a number of approaches have been developed to provide DC current to the rotating field winding in WFSM’s including brushes and slip rings, low frequency brushless exciters, and high frequency rotary transformers and rectifiers. In this project, a different approach was used: brushless capacitive power transfer. Brushless capacitive power transfer uses two sets of rotating capacitors or electrodes in which an AC electric field is established by a high frequency inverter. A displacement current can flow through the airgap in the rotating capacitors which is rectified on the rotor using a diode bridge. The potential advantage of capacitive power transfer is that there is no need for heavy iron to guide magnetic flux. The electric flux lines terminate on the charges on the rotary capacitor surfaces. This should also limit the electric field outside the rotary capacitor airgaps. The main challenge with capacitive power transfer is that the capacitance and surface area of the rotating capacitors is small. Because capacitive power transfer systems are essentially a dual of a magnetic system, an Ampere per Hertz relationship is characteristic versus a Volts per Hertz relationship. A very high frequency power inverter must be used to provide sufficient excitation to the field winding. The concept of using capacitive power transfer to excite a high performance WFSM was initially developed in a previous U.S.A. Dept. of Energy project, DE-EE0006829. This project focused on increasing the power density of the WFSMs and reducing the cost and manufacturing complexity of the capacitive power transfer system. This project has demonstrated that WFSMs with brushless capacitive field power transfer can provide a high-power density and low-cost automotive powertrain technology.

33 ADVANCED PROPULSION SYSTEMS↗

Implementational Aspects for the Characterization of Low-Inertia in Power Systems

The replacement of conventional generating units with non-conventional renewable energy resources impacts the stability of the power system. While the general goal of supplying demand could be achieved from both generation resources, inverter-based energy resources are different from traditional synchronous machines in the sense that they do not inherently provide inertia to the system. The latter obviously worsen the system ability to maintain the balance between supply and demand after certain contingencies such as generator outages. With high integration of renewable-based generation resources, there is a reduction in total system inertia, which could lead to systems with less time to react for frequency restoration in case of such unexpected unit failures. While conceptually it is true, there is a missing gap in the field of power system stability community in terms of test-bed power systems for characterizing low-inertia conditions. In this paper, a framework for low-inertia power systems is presented. The purpose of the test-bed is to establish an environment for testing and conducting research on power systems experiencing low-inertia issues. The frequency nadir, the rate of change of frequency, and the under-frequency load shedding scheme are used as a measure of the healthiness of power grids.

Baquedano-Aguilar, Mario D.↗

Rotating spokes, potential hump and modulated ionization in radio frequency magnetron discharges

Here, in this work, the transition from the gradient drift instability (GDI) into an m = 1 rotating spoke in the radio frequency magnetron discharge was studied by means of the two-dimensional axial-azimuthal (z–y) particle-in-cell/Monte Carlo collision method. The kinetic model combined with the linear analysis of the perturbation revealed that the cathode sheath (axial) electric field E z triggers the GDI, deforming the local potential until the instability condition is not fulfilled and the fluctuation growth stops in which moment the instability becomes saturated. The potential deformation consequently leads to the formation of the potential hump, surrounding which the azimuthal electric field E y is present. The saturation level of E y was found to be synchronized with and proportional to the time-changing voltage applied at the cathode, resulting in the RF-modulation of the electron heating in the E y due to $\nabla B$ drift. In the saturated stage of the instability, it was shown that the rotation velocity and direction of the spoke present in the simulations agree well with the experimental observation (Panjan 2019 J. Appl. Phys.125 203303). In the instability linear stage, the instability mode wavelength and the growth rate were also found to be in good agreement with the prediction of the GDI linear fluid theory.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Distinguishing Mesoscale Polar Order (Unidirectional vs Bidirectional) of Cellulose Microfibrils in Plant Cell Walls Using Sum Frequency Generation Spectroscopy

Cellulose in plant cell walls are synthesized as crystalline microfibrils with diameters of 3–4 nm and lengths of around 1–10 μm. These microfibrils are known to be the backbone of cell walls, and their multiscale three-dimensional organization plays a critical role in cell wall functions including plant growth and recalcitrance to degradation. The mesoscale organization of microfibrils over a 1–100 nm range in cell walls is challenging to resolve because most characterization techniques investigating this length scale suffer from low spatial resolution, sample preparation artifacts, or inaccessibility of specific cell types. Here, we report a sum frequency generation (SFG) study determining the mesoscale polarity of cellulose microfibrils in intact plant cell walls. SFG is a nonlinear optical spectroscopy technique sensitive to the molecular-to-mesoscale order of noncentrosymmetric domains in amorphous matrices. However, the quantitative theoretical model to unravel the effect of polarity in packing of noncentrosymmetric domains on SFG spectral features has remained unresolved. In this work, we show how the phase synchronization principle of the SFG process is used to predict the relative intensities of vibrational modes with different polar angles from the noncentrosymmetric domain axis. Applying this model calculation for the first time and employing SFG microscopy, we found that cellulose microfibrils in certain xylem cell walls are deposited unidirectionally (or biased in one direction) instead of the bidirectional polarity which was believed to be dominant in plant cell walls from volume-averaged characterizations of macroscopic samples. Here, with this advancement in SFG analysis, one can now determine the relative polarity of noncentrosymmetric domains such as crystalline biopolymers interspersed in amorphous polymer matrices, which will open opportunities to study new questions that have not been conceived in the past.

36 MATERIALS SCIENCE↗

Cost Estimation of a Permanent Magnet Synchronous Machine for Use in Adjustable Speed-Pumped Storage Hydropower

Electric machine design has become an easier process with the availability of computers in recent decades. However, the interest in electric machine design among students has declined. University-level design courses must compete with courses perceived as more desirable by the potential job market. Hence, the power system engineers with this expertise are very few and are nearing retirement. Contrarily, renewable energy has been picking up in the past few decades. The indeterminacy and variation of renewable energy sources require a balancing mechanism to maintain the constant voltage and frequency of the grid. Adjustable-Speed Pumped-Storage Hydropower plants are considered the contender for future energy storage, providing large capacity and fast-acting response. Large-scale hydropower applications depend on the natural characteristics of each project site, making less expensive, off-the-shelf generators unfeasible. This work gives a shortcut to estimate the cost of constructing a permanent magnet generator for low-volume manufacturing.

13 HYDRO ENERGY↗