Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FLUOROSCOPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Percutaneous Biopsy of Retrobulbar Masses: Anatomical Considerations and MRI Guidance

PurposeObtaining adequate tissue from retrobulbar masses remains a challenge. To this end, a new method of retrobulbar mass biopsy using MRI guidance is presented.Materials and MethodsTwo patients (7- and 71-year-old male) with indeterminate retrobulbar masses underwent bioptic and cytological samplings using MR-compatible 18G and 20–22G needles, and multi-planar MR fluoroscopy. An inferior approach was taken to avoid injury to the optic nerve and ophthalmic arteries.ResultsThe two biopsies were completed without complication. The core biopsy resulted in a final diagnosis, whereas the cytological sampling was non-diagnostic.ConclusionPercutaneous MR-guided retrobulbar mass biopsy proved to be feasible and safe in the two cases described in this report.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

New Alcohol and Onyx Mixture for Embolization: Feasibility and Proof of Concept in Both In Vitro and In Vivo Models

IntroductionOnyx and ethanol are well-known embolic and sclerotic agents that are frequently used in embolization. These agents present advantages and disadvantages regarding visibility, injection control and penetration depth. Mixing both products might yield a new product with different characteristics. The aim of this study is to evaluate the injectability, radiopacity, and mechanical and occlusive properties of different mixtures of Onyx 18 and ethanol in vitro and in vivo (in a swine model).Materials and MethodsVarious Onyx 18 and ethanol formulations were prepared and tested in vitro for their injectability, solidification rate and shrinkage, cohesion and occlusive properties. In vivo tests were performed using 3 swine. Ease of injection, radiopacity, cohesiveness and penetration were analyzed using fluoroscopy and high-resolution CT.ResultsAll mixtures were easy to inject through a microcatheter with no resistance or blockage in vitro and in vivo. The 50%-ethanol mixture showed delayed copolymerization with fragmentation and proximal occlusion. The 75%-ethanol mixture showed poor radiopacity in vivo and was not tested in vitro. The 25%-ethanol mixture showed good occlusive properties and accepted penetration and radiopacity.ConclusionMixing Onyx and ethanol is feasible. The mixture of 25% of ethanol and 75% of Onyx 18 could be a new sclero-embolic agent. Further research is needed to study the chemical changes of the mixture, to confirm the significance of the added sclerotic effect and to find out the ideal mixture percentages.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Using a Motion Sensor-Equipped Smartphone to Facilitate CT-Guided Puncture

PurposeTo demonstrate the use of “Smart Puncture,” a smartphone application to assist conventional CT-guided puncture without CT fluoroscopy, and to describe the advantages of this application.Materials and MethodsA puncture guideline is displayed by entering the angle into the application. Regardless of the angle at which the device is being held, the motion sensor ensures that the guideline is displayed at the appropriate angle with respect to gravity. The angle of the smartphone’s liquid crystal display (LCD) is also detected, preventing needle deflection from the CT slice image. Physicians can perform the puncture procedure by advancing the needle using the guideline while the smartphone is placed adjacent to the patient. In an experimental puncture test using a sponge as a target, the target was punctured at 30°, 50°, and 70° when the device was tilted to 0°, 15°, 30°, and 45°, respectively. The punctured target was then imaged with a CT scan, and the puncture error was measured.ResultsThe mean puncture error in the plane parallel to the LCD was less than 2°, irrespective of device tilt. The mean puncture error in the sagittal plane was less than 3° with no device tilt. However, the mean puncture error tended to increase when the tilt was increased.ConclusionThis application can transform a smartphone into a valuable tool that is capable of objectively and accurately assisting CT-guided puncture procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characteristics of a New X-Ray Imaging System for Interventional Procedures: Improved Image Quality and Reduced Radiation Dose

PurposeTo compare image quality and radiation exposure between a new angiographic imaging system and the preceding generation system during uterine artery embolization (UAE).Materials and MethodsIn this retrospective, IRB-approved two-arm study, 54 patients with symptomatic uterine fibroids were treated with UAE on two different angiographic imaging systems. The new system includes optimized acquisition parameters and real-time image processing algorithms. Air kerma (AK), dose area product (DAP) and acquisition time for digital fluoroscopy (DF) and digital subtraction angiography (DSA) were recorded. Body mass index was noted as well. DF image quality was assessed objectively by image noise measurements. DSA image quality was rated by two blinded, independent readers on a four-rank scale. Statistical differences were assessed with unpaired t tests and Wilcoxon rank-sum tests.ResultsThere was no significant difference between the patients treated on the new (n = 36) and the old system (n = 18) regarding age (p = 0.10), BMI (p = 0.18), DF time (p = 0.35) and DSA time (p = 0.17). The new system significantly reduced the cumulative AK and DAP by 64 and 72%, respectively (median 0.58 Gy and 145.9 Gy*cm{sup 2} vs. 1.62 Gy and 526.8 Gy*cm{sup 2}, p < 0.01 for both). Specifically, DAP for DF and DSA decreased by 59% (75.3 vs. 181.9 Gy*cm{sup 2}, p < 0.01) and 78% (67.6 vs. 312.2 Gy*cm{sup 2}, p < 0.01), respectively. The new system achieved a significant decrease in DF image noise (p < 0.01) and a significantly better DSA image quality (p < 0.01).ConclusionsThe new angiographic imaging system significantly improved image quality and reduced radiation exposure during UAE procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Technical and Imaging Outcomes from the UK Registry of Prostate Artery Embolization (UK-ROPE) Study: Focusing on Predictors of Clinical Success

Introduction: The UK Registry of Prostate Artery Embolization (UK-ROPE) was a prospective, multicentre study comparing PAE against surgical therapies for symptomatic benign prostatic hyperplasia (BPH). A wealth of data was collected supplementary to the main study outcomes which provide a snapshot of UK PAE practice. We aimed to interpret these data in the hope of providing insight into factors which affect clinical outcome and radiation dose. Methods: 216 patients (mean age 66, mean IPSS 21.3) undergoing PAE at 20 British centres from July 2014 to January 2016 were prospectively followed up to 12 months with retrospective analysis of the data. Technical outcome was evaluated based on procedural and fluoroscopy times, skin dose and dose area product (DAP). Clinical outcome was evaluated through collection of Qmax, IPSS reduction and prostate volume reduction. Multiple analysis of variance (MANOVA) was used to assess the significance of various patients and procedural factors on clinical outcome and patient dose. Results: Significant predictors of technical outcome which affected patient skin dose included severity of CTA-detected atheroma (p < 0.001), the practitioner (p < 0.001) and use of protective coil embolization (p = 0.019). Predictors of clinical outcome included initial prostate size (dichotomized into groups > 80 ml and = <80 ml, d = 1, p = 0.0138), embolic agent (spherical particles < 300 nm performed best, p = 0.01) and number of arteries embolized (IPSS reduction of 32.9% in unilateral PAE versus 54.4% for bilateral PAE, p = 0.026). Conclusion: We have identified several important factors which are associated with improved clinical outcome and increased patient dose which we hope will facilitate optimal patient selection and encourage improved embolization technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fenestrated Thoracic Endovascular Aortic Repair Using Physician-Modified Stent Grafts (PMSGs) in Zone 0 and Zone 1 for Aortic Arch Diseases

Purpose: To evaluate the outcomes of fenestrated thoracic endovascular aortic repair (f-TEVAR) using physician-modified stent grafts (PMSGs) in zone 0 and zone 1 for aortic arch diseases. Methods: f-TEVAR using PMSGs in Z0 and Z1 was performed on ten high-risk patients for open surgery from November 2015 to September 2017. Indications were complicated acute type B dissection (ABAD) with retrograde dissection involving the mid-arch (n = 1), distal arch aneurysms (n = 3), mid-arch aneurysms of the inner arch curvature (n = 3) and penetrating aortic ulcer located in the mid- or proximal arch (n = 3). Pre-, intra- and postoperative clinical data were recorded. Results: The median patient age was 61 (range 45–81) years, and 9 (90%) patients were men. Ten PMSGs (Medtronic Valiant stent grafts, n = 1; Relay thoracic stent grafts, n = 4; Cook TX2 device, n = 5) were deployed. PMSGs were deployed from Z0 and Z1 in 5 and 5 patients, respectively. Double small fenestrations for the left subclavian artery (LSA) and the left common carotid artery (LCCA), respectively, were created in 3 patients. Triple small fenestrations for the innominate artery (IA), the LCCA and the LSA, respectively, were created in 2 patients. One large fenestration for both the IA and the LCCA combined with one small fenestration for the LSA was created in 3 patients. One large fenestration for the LCCA combined with one small fenestration for the LSA was created in 2 patients. Posterior diameter-reducing ties were added to all the devices except to one Valiant stent graft. All but 2 patients underwent elective procedure. Median duration for stent graft modifications was 105 (range 90–125) min. The technical success rate was 90%. Overall mortality was 10% (1/10). One patient died of sudden cardiac arrest intraoperatively after the deployment of the PMSG and all the supra-aortic branch stents. Mean operative time was 106.0 ± 43.0 min, and fluoroscopy time was 30.6 ± 22.9 min. There were no type I or type III endoleaks, perioperative neurological complications or spinal cord ischemia. Median length of stay was 8 (range 4–35) days. Nine patients survived at mean 13.3 (range 6.0–19.0) months follow-up. Retrograde dissection occurred in one patient of Z0 group 40 days post-f-TEVAR and resolved after open repair. During follow-up, all target vessels remained patent without fenestration-related type I or III endoleaks. Conclusions: f-TEVAR using PMSGs in Z0 and Z1 for the treatment of aortic arch diseases in high-risk patients is feasible in the hands of experienced operators.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prospective Study on Total Fluoroscopic Time in Patients Undergoing Uterine Artery Embolization: Comparing Transradial and Transfemoral Approaches

Purpose: Comparing total fluoroscopy time (FT) to perform uterine artery embolization (UAE) with transradial approach (TRA) versus transfemoral approach (TFA). Our hypothesis was that there would be no significant procedural time penalty incurred, despite the learning curve associated with adopting a new approach. Materials and Methods: A cohort study was undertaken including 66 consecutive patients undergoing UAE with either TRA/TFA between January and September 2015. Total FT was recorded prospectively for each procedure, and data subsequently analyzed retrospectively. Each operator had at least 2 years of experience as an interventional radiologist having performed at least 200 TFA UAEs. All operators had recently incorporated TRA into their practice. Results: A total of 39 TFA and 27 TRA cases were included in the study; mean age for TFA group was 44.4 years (± 4.9) and for TRA group was 45.1 years (± 4.9) (p = 0.59). Mean FTs were comparable between the two groups (p = 0.86) despite a learning curve associated with TRA: The mean total FT with TFA was 20.36 min (± 9.48) compared to TRA 20.12 min (± 7.67). Conclusions: FTs for TRA UAE were comparable to TFA UAE, even though TRA had been recently adopted as a new approach. Despite the learning curve associated with developing a novel technique, operators should not expect the efficiency of their service to be significantly compromised. Introducing this safe and effective method of vascular access should therefore be considered.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Unusual Access for the Treatment of Iliac Artery Aneurysm in Association with Type II Endoleak After Endovascular Repair of an Aortoiliac Aneurysm

Internal iliac artery aneurysms (IIAAs), although rare, are associated with a significant risk of mortality, if they rupture. Endovascular approach with exclusion of the aneurysm sac from antegrade and retrograde perfusion is proved to be a feasible treatment option. However, this option is not always technically possible with a preexisting endovascular aneurysm repair (EVAR) or surgical aortoiliac reconstruction with ligation of internal iliac artery origin. We report another safe treatment option of an enlarging IIAA associated with a type II endoleak after EVAR and a standard endovascular treatment was not possible. The access to the aneurysm sac was achieved retrograde via percutaneous access to the superior gluteal artery under fluoroscopy followed by treatment with embolization of the inflow and outflow vessels.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Non-conservative Management of Placenta Accreta Spectrum in the Hybrid Operating Room: A Retrospective Cohort Study

Introduction: Hysterectomy is the standard of care in placenta accreta spectrum (PAS). To reduce the risks of obstetric hemorrhage during surgery, endovascular interventions have been proposed. Our aim is to evaluate the feasibility and safety of the overall non-conservative management of PAS in the hybrid operating room (OR) to replace the classic two-step procedure (catheterization in the interventional radiology suite and transfer to conventional OR). Materials and Methods: This is a retrospective study of series of patients with histopathologic confirmation of PAS treated in the hybrid OR at the same university hospital. We used for comparison our historical cohort managed with the standard two-step procedure. Results: We included 110 patients, 80 in the conventional OR and 30 in the hybrid OR. There were no cases of major complications attributable to the endovascular procedures. In the two-step procedure, there were 10 (12.5%) intra-arterial catheter displacements that required repositioning in the conventional OR under mobile C-arm fluoroscopy and no cases in the hybrid OR (p = 0.04). The mean operative time was 380 + 42 min in the conventional OR and 296 + 66 min in the hybrid OR (p = .00001). There were no differences in the gestational age at delivery, postoperative length of stay, or large-volume blood transfusion. There were no maternal deaths. Conclusions: The overall non-conservative management of PAS in the hybrid OR has shown to be feasible and safe in our series, offering potential advantages to replace the classic two-step procedure. More studies are needed to evaluate whether this strategy is cost-effective and whether it may improve maternal and perinatal outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image-Guided Percutaneous Bleomycin and Bevacizumab Sclerotherapy of Orbital Lymphatic Malformations in Children

Purpose: To evaluate the effectiveness and safety of image-guided percutaneous sclerotherapy using bleomycin for macrocystic and bevacizumab (Avastin™) for microcystic orbital lymphatic malformations in children. Materials and Methods: Between October 2015 and July 2018, we prospectively evaluated 10 pediatric patients who presented clinically and radiologically with lymphatic malformations and were treated with percutaneous sclerotherapy. Patients with venous malformations were excluded. Eight females and two males with ages ranging from 3 to 17 years (mean: 8.8, SD: 4.9) were included. Guided with ultrasound and fluoroscopy, macrocysts were treated with bleomycin instillation. For microcystic components in three patients, bevacizumab was injected intralesional. All patients underwent ultrasound and non-contrast MRI to evaluate response to treatment after 6 weeks. Results: The malformations were macrocystic in seven patients and complex (macro/microcystic) in three. Twenty sclerotherapy sessions were performed, (range: 1–3 sessions, mean: 2, SD: 0.8). Clinically, there was a significant reduction in the proptosis after treatment (P = 0.007) and dystopia (P = 0.018). The local radiological response showed a reduction in the maximum lesions diameters and volumes after treatment (P = 0.005 and 0.005, respectively). Two of the three patients treated with bevacizumab showed a reduction in the lesions volumes by 90.4% and 63.4%, respectively, whereas one patient did not show volume reduction. Transient periorbital edema and ecchymosis occurred following the procedure with no major complications encountered. Follow-up ranged from 9–33 months, mean: 20.3, SD: 7.4. Conclusion: Bleomycin sclerotherapy is a safe and effective treatment for orbital macrocystic lymphatic malformations. Further use of bevacizumab for microcystic lesions in a larger series is required to outline its efficacy and safety.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Virtual Guidance of Percutaneous Transthoracic Needle Biopsy with C-Arm Cone-Beam CT: Diagnostic Accuracy, Risk Factors and Effective Radiation Dose

Purpose: C-arm cone-beam computed tomography-guided transthoracic lung core needle biopsy (CBCT-CNB) is a safe and accurate procedure for the evaluation of patients with pulmonary nodules. The purpose of our study was to evaluate the diagnostic performance, complication rates and effective radiation dose of CBCT-CNB with virtual guidance. Materials and Methods: We retrospectively collected data regarding 375 CBCT-CNBs performed with virtual guidance (XperGuide—Philips Healthcare, Best, The Netherlands) from January 2010 to June 2015 on 355 patients (mean age, 68.1 years ± 11.8; age range, 31–88 years). Patients were divided into groups and compared based on the diagnostic failure and lesion size (15 mm cutoff). Diagnostic performance, complication rate and effective radiation dose were investigated. Variables influencing diagnostic performance and complications were assessed using Student’s T test and Pearson’s χ{sup 2} test. Results: The sensitivity, specificity, positive and negative predictive value and accuracy for patients subjected to CNBs were 96.8%, 100%, 100%, 100% and 97.2%, respectively. Considering risk factors for pneumothorax, no significant differences were found regarding patient and lesion characteristics. Perilesional hemorrhage occurred more frequently in older patients (p = 0.046) and in smaller lesions (p = 0.001). Hemoptysis was significantly more frequent in patients with perilesional hemorrhage (p = 0.01). Mean effective radiation dose in CBCT-CNB was 7.12 ± 8.78 mSv. Conclusions: CBCT-CNB combined with virtual guidance is a reliable and accurate technique that allows exact localization of pulmonary lesions, effective preprocedural planning and real-time fluoroscopy altogether.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transhepatic Tract Embolisation After Biliary Intervention Using n-Butyl Cyanoacrylate and Autologous Blood: A Retrospective Analysis of 42 Patients

Purpose: We evaluated the safety and efficacy of transhepatic tract embolisation after a biliary intervention using n-butyl cyanoacrylate (NBCA) and autologous blood. Materials and Methods: Between January 2017 and December 2018, 42 consecutive patients (mean age: 71 ± 15 years, 24 men) with malignant (n = 26) or benign (n = 16) biliary obstructions underwent percutaneous biliary intervention followed by tract embolisation within 2 weeks. Forty-six transhepatic tracts (4 bilateral) in 42 patients were embolised using a NBCA and lipiodol mixtures (1:1–1:2 ratios) after intraductal infusion of peripherally obtained autologous blood. The indwelling catheter diameters were 8.5–14 Fr. The median interval between percutaneous biliary drainage and tract embolisation was 10 days (range 3–14 days). Glue-cast formation via fluoroscopy and immediate complications were reviewed retrospectively in medical records. Follow-up data (median: 135, range 11–720 days) including computed tomography (CT) images (n = 17) were evaluated for delayed complications and glue-cast formation. Results: Successful glue-cast formations were achieved in all 46 tracts. No patients experienced haemorrhage, and only one patient had external bile leakage. Eight patients complained of abdominal pain (numerical scale ≤ 5) immediately after embolisation, which was controlled by analgesics. Two patients had transient fever. Segmental (n = 11) or sub-segmental (n = 6) glue-cast patterns were identified along the transhepatic tract by follow-up CT. No biliary obstructions were caused by inadvertent glue spread. Fragmented glue was detected outside the stent in one patient. Conclusion: Transhepatic parenchymal tract embolisation with NBCA and autologous blood is a safe and feasible method for preventing bile leakage. Level of Evidence: Level 4, Case Series.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simulation of Endovascular Aortic Repair Using 3D Printed Abdominal Aortic Aneurysm Model and Fluid Pump

Background: Abdominal aortic aneurysm (AAA) models can be manufactured with 3D printing technology. This study describes detailed methodology and validation of endovascular aortic repair (EVAR) simulation using 3D printed AAA model connected to hemodynamic pump. Method: The AAA model was printed with Objet500 Connex3 (Stratasys, Eden Prairie, MN) and connected to BDC PD-0500 fluid pump (BDC Laboratories, Wheat Ridge, CO). EVAR procedure metrics were benchmarked in two expert implanters and compared to 20 vascular surgical trainees with different levels of EVAR experience (< 20 or ≥ 20 cases). All simulations were performed using commercially available stent grafts, guidewires, catheters, fluoroscopic guidance and digital subtraction angiography. Studied outcomes included ability to complete the procedure independently, time to deploy aortic component, ability to cannulate contralateral gate and complete the repair, and total fluoroscopy and procedure times. Results: A total of 22 EVAR simulation procedures were performed with mean procedure time of 37 ± 12 min. Experienced trainees had significantly lower total procedural time (32 ± 9 vs. 44 ± 6 min, P = 0.003) and fluoroscopic time (13 ± 5 vs. 23 ± 8 min, P = 0.005). All experienced trainees completed the procedure independently in < 45 min, compared to six (46%) of those with less EVAR experience (P = 0.016). Among less experienced trainees, only two (15%) completed the entire procedure independently (P < 0.001). Benchmark implanters performed significantly better than both trainee groups in nearly all EVAR metrics. Conclusion: EVAR simulation was feasible and simulated all procedural steps with high fidelity. This model may be applicable for assessment of technical competencies and standard endovascular skill acquisition within vascular surgery training curricula.

3D PRINTING↗

Percutaneous Lung Tumor Biopsy Under CBCT Guidance with PET-CT Fusion Imaging: Preliminary Experience

Purpose: The aim of this study is to evaluate the feasibility of percutaneous lung tumor biopsy under cone beam-computed tomography (CBCT) with PET-CT imaging fusion. Materials and Methods: Eleven patients (four women and seven men) underwent C-arm CBCT lung biopsy with PET-CT fusion imaging. A preprocedural PET-CT scan was manually fused with procedural CBCT based on anatomical landmarks; using real-time fluoroscopy, the coregistered PET-CT and CBCT images were overlaid to guide the needle trajectory. Technical success, accuracy, sensibility and specificity were evaluated. Mean total procedure time and time required for image elaboration were recorded. Results: Technical success, diagnostic accuracy, sensitivity and specificity were 100%. The mean procedure time was 38 min. The average time of PET-CT/CBCT image fusion elaboration was 3.53 min for planning and 3.42 min for needle positioning check. Conclusion: CBCT-guided percutaneous lung biopsy with PET-CT fusion imaging is a feasible and effective procedure, with the potential to further improve diagnostic yield by targeting the most metabolically active portion of a lesion, whether it is morphologically altered or normal.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fusion Imaging to Guide Thoracic Endovascular Aortic Repair (TEVAR): A Randomized Comparison of Two Methods, 2D/3D Versus 3D/3D Image Fusion

Purpose: To compare the accuracy of two-dimensional (2D) versus three-dimensional (3D) image fusion for thoracic endovascular aortic repair (TEVAR) image guidance. Materials and Methods: Between December 2016 and March 2018, all eligible patients who underwent TEVAR were prospectively included in a single-center study. Image fusion methods (2D/3D or 3D/3D) were randomly assigned to guide each TEVAR and compared in terms of accuracy, dose area product (DAP), volume of contrast medium injected, fluoroscopy time and procedure time. Results: Thirty-two patients were prospectively included; 18 underwent 2D/3D and 14 underwent 3D/3D TEVAR. The 3D/3D method allowed more accurate positioning of the aortic mask on top of the fluoroscopic images (proximal landing zone error vector: 1.7 ± 3.3 mm) than was achieved by the 2D/3D method (6.1 ± 6.1 mm; p = 0.03). The 3D/3D image fusion method was associated with significantly lower DAP than the 2D/3D method (50.5 ± 30.1 Gy cm{sup 2} for 3D/3D vs. 99.5 ± 79.1 Gy cm{sup 2} for 2D/3D; p = 0.03). The volume of contrast medium injected was significantly lower for the 3D/3D method than for the 2D/3D method (50.6 ± 22.9 ml vs. 98.4 ± 47.9 ml; p = 0.002). Conclusion: Higher image fusion accuracy and lower contrast volume and irradiation dose were observed for 3D/3D image fusion than for 2D/3D during TEVAR. Level of Evidence: II, Randomized trial.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transplantation of dedifferentiation fat cells promotes intervertebral disc regeneration in a rat intervertebral disc degeneration model

Our group has reported that mature adipocyte-derived dedifferentiated fat (DFAT) cells show multilineage differentiation potential similar to that observed in mesenchymal stem cells. In the present study, we examined whether DFAT cell transplantation could contribute to intervertebral disc regeneration using a rat intervertebral disc degeneration (IDD) model. The IDD was created in Sprague-Dawley rats by puncturing at level of caudal intervertebral disc under fluoroscopy. One week after injury, rat DFAT cells (5 × 10{sup 4}, DFAT group, n = 13) or phosphate-buffered saline (PBS, control group, n = 13) were injected into the intervertebral disc. Percent disc height index (%DHI) was measured every week and histology of injured disc was evaluated at 8 weeks after transplantation. Radiographic analysis revealed that the %DHI in the DFAT group significantly higher than that in the control group at 2–3 weeks after transplantation. Histological analysis revealed that ectopic formation of nucleus pulposus (NP)-like tissue at the outer layer of annulus fibrosus was frequently observed in the DFAT group but not in the control group. Transplantation experiments using green fluorescent protein (GFP)-labeled DFAT cells revealed that the ectopic NP-like tissue was positive for GFP, suggesting direct differentiation of DFAT cells into NP-like cells. In conclusion, DFAT cell transplantation promoted the regeneration of intervertebral disc and improved intervertebral disc height in the rat IDD model. Because adipose tissue is abundant and easily accessible, DFAT cell transplantation may be an attractive therapeutic strategy against IDD. - Highlights: • Dedifferentiated fat cells (DFATs) are adipocyte-derived mesenchymal stem-like cells. • DFAT injection increases disc height in a rat intervertebral disc degeneration model. • Transplanted DFATs directly differentiate into the nucleus pulposus-like tissue. • DFATs may be an attractive cell source for intervertebral disc degeneration.

60 APPLIED LIFE SCIENCES↗

Clinical Results of Image-Guided Deep Inspiration Breath Hold Breast Irradiation

Purpose: To evaluate the feasibility, cardiac dose reduction, and the influence of the setup error on the delivered dose for fluoroscopy-guided deep inspiration breath hold (DIBH) irradiation using a cone-beam CT for irradiation of left-sided breast cancer patients. Methods and Materials: Nineteen patients treated according to the DIBH protocol were evaluated regarding dose to the ipsilateral breast (or thoracic wall), heart, (left ventricle [LV]and left anterior descending artery [LAD]), and lung. The DIBH treatment plan was compared to the free-breathing (FB) treatment planning and to the dose data in which setup error was taken into account (i.e., actual delivered dose). Results: The largest setup variability was observed in the direction perpendicular to the RT field ({mu} = -0.8 mm, {Sigma} = 2.9 mm, {sigma} = 2.0 mm). The mean (D{sub mean}) and maximum (D{sub max}) doses of the DIBH treatment plan was significantly lower compared with the FB treatment plan for the heart (34% and 25%, p < 0.001), LV (71% and 28%, p < 0.001), and LAD (52% and 39.8%, p < 0.001). For some patients, large differences were observed between the heart D{sub max} according to the DIBH treatment plan and the actual delivered dose (up to 71%), although D{sub max} was always smaller than the planned FB dose (mean group reduction = 29%, p < 0.001). Conclusion: The image-guided DIBH treatment protocol is a feasible irradiation method with small setup variability that significantly reduces the dose to the heart, LV, and LAD.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intrafractional Target Motions and Uncertainties of Treatment Setup Reference Systems in Accelerated Partial Breast Irradiation

Purpose: This study investigated the magnitude of intrafractional motion and level of accuracy of various setup strategies in accelerated partial breast irradiation (APBI) using three-dimensional conformal external beam radiotherapy. Methods and Materials: At lumpectomy, gold fiducial markers were strategically sutured to the surrounding walls of the cavity. Weekly fluoroscopy imaging was conducted at treatment to investigate the respiration-induced target motions. Daily pre- and post-RT kV imaging was performed, and images were matched to digitally reconstructed radiographs based on bony anatomy and fiducial markers, respectively, to determine the intrafractional motion magnitudes over the course of treatment. The positioning differences of the laser tattoo- and the bony anatomy-based setups compared with those of the marker-based setup (benchmark) were also determined. The study included 21 patients. Results: Although lung exhibited significant motion, the average marker motion amplitude on the fluoroscopic image was about 1 mm. Over a typical treatment time period, average intrafractional motion magnitude was 4.2 mm and 2.6 mm based on the marker and bony anatomy matching, respectively. The bony anatomy- and laser tattoo-based interfractional setup errors, with respect to the fiducial marker-based setup, were 7.1 and 9.0 mm, respectively. Conclusions: Respiration has limited effects on the target motion during APBI. Bony anatomy-based treatment setup improves the accuracy relative to that of the laser tattoo-based setup approach. Since fiducial markers are sutured directly to the surgical cavity, the marker-based approach can further improve the interfractional setup accuracy. On average, a seroma cavity exhibits intrafractional motion of more than 4 mm, a magnitude that is larger than that which is otherwise derived based on bony anatomy matching. A seroma-specific marker-based approach has the potential to improve treatment accuracy by taking the true inter- and intrafractional motions into consideration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗