Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FLOW RATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Emergent Behavior at the Calcite–Water Interface during Reactive Transport in a Simple Microfluidic Channel

Geochemical reactive transport processes in natural mineral-fluid systems may produce a wide array of emergent phenomena that are difficult to predict from basic principles and to reproduce in model systems. In this study, we present experimental results obtained from a simple microfluidic system with which we explored the consequences of reacting the calcite (104) cleavage surface with an acidic Pb-bearing solution (pH = 3.5, [Pb] total = 5 mM) as a function of flow rate. This system is relevant to passive remediation systems for Pb-rich acid mine drainage. We observed periodic banding in the amounts of Pb sorption at flow velocities ≥ 926 μm s -1 , where the band spacing was spatially correlated with the amount of calcite dissolution and the development of micropyramidal topography on the calcite (104) surface. The equivalent coverage of Pb deposited in these Pb-rich bands was at least several monolayers per unit cell, yet there was no evidence for precipitation of any secondary Pb phase implying incorporation of Pb within the near-surface calcite lattice. We also observed spatial variations in nucleation and growth of euhedral secondary Pb-carbonate minerals hydrocerusite and cerussite at flow rates ≤ 278 μm s -1 ,. These findings demonstrate potential for exploiting the rich phenomenology afforded by the interplay among transport phenomena and chemical kinetics in experimental systems designed to yield deeper insights into geochemical self-organization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rarefied xenon flow in orificed hollow cathodes

A parametric study is conducted to quantify the effect of the keeper electrode geometry on the xenon neutral flow quantities within orificed hollow cathodes, prior to ignition. The keeper impinges directly on the flow out of the cathode orifice and its geometry influences the product between the pressure in the orifice–keeper region and the cathode-to-keeper distance. A representative cathode is simulated using the Direct Simulation Monte Carlo method. The numerical model is first validated with computational results from the literature. A parametric study is then conducted. Parameters include the cathode pressure–diameter in the range of 1–5 Torr cm and the following geometric ratios (and ranges): cathode orifice-to-inner radii (0.1–0.7), keeper orifice-to-cathode orifice radii (1–5), and keeper distance-to-cathode-orifice diameter (0.5–10). It is found that, if both keeper and cathode have identical orifice radii, the flow remains subsonic in the orifice-to-keeper region. In most cases, however, the flow becomes underexpanded and supersonic, and the static pressure within the orifice-to-keeper region is, on average, 4% that of the upstream pressure value. The orifice–keeper region pressure increases with either a decrease in the keeper orifice diameter or an increase in the distance between cathode and keeper, in agreement with literature data. Both trends are explained through conservation laws. A statistical study of numerical results reveals that the ratio of ignition-to-nominal mass flow rates has a most probable value of 50, which suggests that heaterless cathode ignition at a minimum DC voltage may be achieved by increasing the input mass flow rate by a factor of 50.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hydrogen embrittlement of Zircaloy-4 fabricated by ultrasonic additive manufacturing

Ultrasonic additive manufacturing (UAM) was successfully applied to the zirconium material system to create a planar geometry. Following fabrication, SS-J3 type tensile specimens of the UAM and wrought Zircaloy-4 with a nominal gage section of 5×1.2×0.75 mm were machined for hydriding studies and mechanical testing. The SS-J3 type tensile specimens were gas-charged with hydrogen using a custom system that precisely controls hydrogen gas flow rate, hydrogen partial pressure, and temperature. To avoid altering the UAM material, the maximum process temperature was limited to 550°C. Using different initial hydrogen gas pressures and flow rates, various hydrogen contents (70–1755 wppm) were achieved for Zircaloy-4 specimens. Tensile testing shows that, regardless of hydrogen content, all UAM specimens measured yield strengths in the range of 557±16 MPa and ultimate tensile strengths of 660±4MPa. However, total elongation clearly decreased as a function of increasing hydrogen content. Further, at the lowest hydrogen content, the total plastic elongation measured 21.5%, and this value decreased to less than 2% when the hydrogen content was increased to 1000 wppm. Cross-sectional optical microscopy images revealed that the hydride distributions are randomly oriented. For the low hydrogen content specimen, these randomly distributed hydrides are isolated from each other. A sandwiched structure, consisting of high-density and low-density layers, was also observed for the specimens with hydrogen content between 200 and 400 wppm. As the hydrogen content increases, the hydrides diffuse into the low-density hydride layers to form a network across the whole specimen. Although the tensile properties of UAM and wrought Zircaloy-4 exhibit the same behavior with increasing hydrogen content, the distinctions in grain orientations led to differences in the hydride orientations at low and intermediate hydrogen concentrations.

36 MATERIALS SCIENCE↗

Comparative Analysis of HEATNETS for Geothermal Network Performance

Thermal energy networks (TENs), also known as 5th generation district energy systems, or more specifically geothermal networks when exchanging heat with geothermal boreholes, are an important technology for decarbonization. In these networks an ambient loop connects buildings and thermal sources, such as a borehole field, to exchange energy and maintain a desired loop temperature. Water-source heat pumps are used at the buildings to connect to the ambient or thermal loop to meet to the building heating and cooling loads and maintain comfort. A semi-transient, reduced-order technical model and techno-economic model, called HEATNETS, has been developed at NREL that captures the flow of energy around a TEN. In this work, a comparison of the HEATNETS technical model and a well-known coding platform used for modeling geothermal networks, TRNSYS, has been completed for a proposed geothermal network as a verification and validation process. Hourly data provided from the TRNSYS simulation included building loads, pumping power, heat pump power, temperature entering and leaving the borehole field, and mass flow rates. The hourly borehole temperatures were used to create a linear regression model utilized in HEATNETS to estimate the borehole field heat exchange. The building loads and mass flow rates were direct inputs to HEATNETS while the pumping power, heat pump power, borehole temperatures, and coefficients of performance were all simulated and calculated by HEATNETS, allowing for direct comparison of the thermal energy transfer HEATNETS considers the full process from design inputs to economic outputs and can provide modeling options for high-level initial system design and operational optimization. This study focuses on a validation of HEATNETS using results from TRNSYS. HEATNETS is not intended to replace other modeling tools, but this work demonstrates, via a comparison with an industry standard code, that HEATNETS can be a unique, high-level and rapid modeling tool for estimating the performance of a full geothermal network system.

15 GEOTHERMAL ENERGY↗

Hydraulic and Thermal Stimulation Program at Raft River Idaho, A DOE EGS

A Department of Energy Enhanced Geothermal System (EGS) stimulation program has injected over 254 million gallons of water into the well RRG-9 ST1 since the summer of 2013. Three major stimulations have been conducted during the program increasing injection flow rates from less than 20 gpm to 550 gpm. Geologic, water chemistry, microseismic activity, and borehole imaging data have been used to develop a conceptual model describing possible flow paths of this injected water. This model contains two major fracture zones one of which intersects the RRG-9 ST1 wellbore. Modified Hall and injectivity index plots constructed using injection flow rates, surface temperatures, and wellhead pressures show steady improvement in the injectivity of the well. Here, the injectivity index has risen from 0.15 gpm/psi to 2.0 gpm/ psi. A pressure falloff test conducted on April 28, 2015 indicates a reservoir permeability of 1,220 md and -5.38 skin factor. The well stimulation program was simulated numerically using an Idaho National Laboratory reservoir simulation code, FALCON. These simulations show a significant increase in the permeability of connecting fracture pathways after each stimulation event.

Enhanced geothermal system↗

Development of dispensing hardware for safe fueling of heavy duty vehicles

The development of safe dispensing equipment for the fueling of heavy duty (HD) vehicles is critical to the expansion of this newly and quickly expanding market. This paper discusses the development of a HD dispenser and nozzles assembly (nozzle, hose, breakaway) for these new, larger vehicles where flow rates are more than double compared to light duty (LD) vehicles. This equipment must operate at nominal pressures of 700 bar, -40o C gas temperature, and average flow rate of 5-10 kg/min at a high throughput commercial hydrogen fueling station without leaking hydrogen. The project surveyed HD vehicle manufacturers, station developers, and component suppliers to determine the basic specifications of the dispensing equipment and nozzle assembly. The team also examined existing codes and standards to determine necessary changes to accommodate HD components. From this information, the team developed a set of specifications which will be used to design the dispensing equipment. In order to meet these goals, the team performed computational fluid dynamic, pressure modelling, and temperature analysis in order to determine the necessary parameters to meet existing safety standards modified for HD fueling. The team also considered user, operational, and maintenance requirements, such as freeze lock which has been an issue which prevents the removal of the nozzle from LD vehicles. The team also performed a failure mode and effects analysis (FMEA) to identify the possible failures in the design. The dispenser and nozzle assembly will be tested separately, and then installed on an innovative, HD fueling station which will use a HD vehicle simulator to test the entire system.

08 HYDROGEN↗

Comparative Analysis of HEATNETS for Geothermal Network Performance: Preprint

Thermal energy networks (TENs), also known as 5th generation district energy systems, or more specifically geothermal networks when exchanging heat with geothermal boreholes, are an important technology for decarbonization. In these networks an ambient loop connects buildings and thermal sources, such as a borehole field, to exchange energy and maintain a desired loop temperature. Water-source heat pumps are used at the buildings to connect to the ambient or thermal loop to meet to the building heating and cooling loads and maintain comfort. A semi-transient, reduced-order technical model and techno-economic model, called HEATNETS, has been developed at NREL that captures the flow of energy around a TEN. In this work, a comparison of the HEATNETS technical model and a well-known coding platform used for modeling geothermal networks, TRNSYS, has been completed for a proposed geothermal network as a verification process. Hourly data provided from the TRNSYS simulation included building loads, pumping power, heat pump power, temperature entering and leaving the borehole field, and mass flow rates. The hourly borehole temperatures were used to create a linear regression model utilized in HEATNETS to estimate the borehole field heat exchange. The building loads and mass flow rates were direct inputs to HEATNETS while the pumping power, heat pump power, borehole temperatures, and coefficients of performance were all simulated and calculated by HEATNETS, allowing for direct comparison of the thermal energy transfer, rather than also comparing control systems responses. HEATNETS considers the full process from design inputs to economic outputs and can provide modeling options for high-level initial system design and operational optimization. This study shows that HEATNETS, while not intended to replace other modeling tools, can be a unique modeling tool for the performance of a full geothermal network system.

15 GEOTHERMAL ENERGY↗

Optimization of flow in additively manufactured porous columns with graded permeability

Chemical engineering systems often involve a functional porous medium, such as in catalyzed reactive flows, fluid purifiers, and chromatographic separations. Ideally, the flow rates throughout the porous medium are uniform, and all portions of the medium contribute efficiently to its function. The permeability is a property of a porous medium that depends on pore geometry and relates flow rate to pressure drop. Additive manufacturing techniques raise the possibilities that permeability can be arbitrarily specified in three dimensions, and that a broader range of permeabilities can be achieved than by traditional manufacturing methods. Using numerical optimization methods, we show that designs with spatially varying permeability can achieve greater flow uniformity than designs with uniform permeability. We consider geometries involving hemispherical regions that distribute flow, as in many glass chromatography columns. By several measures, significant improvements in flow uniformity can be obtained by modifying permeability only near the inlet and outlet.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Anomaly Detection in Liquid Sodium Cold Trap Operation with Multisensory Data Fusion Using Long Short-Term Memory Autoencoder

Sodium-cooled fast reactors (SFR), which use high temperature fluid near ambient pressure as coolant, are one of the most promising types of GEN IV reactors. One of the unique challenges of SFR operation is purification of high temperature liquid sodium with a cold trap to prevent corrosion and obstructing small orifices. We have developed a deep learning long short-term memory (LSTM) autoencoder for continuous monitoring of a cold trap and detection of operational anomaly. Transient data were obtained from the Mechanisms Engineering Test Loop (METL) liquid sodium facility at Argonne National Laboratory. The cold trap purification at METL is monitored with 31 variables, which are sensors measuring fluid temperatures, pressures and flow rates, and controller signals. Loss-of-coolant type anomaly in the cold trap operation was generated by temporarily choking one of the blowers, which resulted in temperature and flow rate spikes. The input layer of the autoencoder consisted of all the variables involved in monitoring the cold trap. The LSTM autoencoder was trained on the data corresponding to cold trap startup and normal operation regime, with the loss function calculated as the mean absolute error (MAE). The loss during training was determined to follow log-normal density distribution. During monitoring, we investigated a performance of the LSTM autoencoder for different loss threshold values, set at a progressively increasing number of standard deviations from the mean. The anomaly signal in the data was gradually attenuated, while preserving the noise of the original time series, so that the signal-to-noise ratio (SNR) averaged across all sensors decreased below unity. Results demonstrate detection of anomalies with sensor-averaged SNR < 1.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Vibroacoustic Process Monitoring of 5-Stage Centrifugal Contactors

Vibroacoustic monitoring was investigated to aid in informing process operators with parameters regarding aqueous separation techniques. These techniques have a wide range of applications including nuclear fuel reprocessing. A small-scale solvent extraction system was set up with five magnetic drive contactors and two piston pumps to collect realistic operation. Vibration sensors were placed on three of the contactors and both pumps, and a microphone was placed near the system. Contactor rotational speed and pump flow rate were varied with known values to compare against measured vibroacoustic signatures. Spectral analysis allowed for the determination of contactor rotational speed and the ratio of organic to aqueous flow rate, an important parameter for ensuring optimal extraction. Vibration metrics such as kurtosis and crest factor provided additional details regarding individual rotational speeds and have potential in examination of faults for predictive maintenance. Overall, results indicate the capability of vibroacoustic monitoring to improve operator awareness and process outcomes.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Pore size effect on selective gas transport in shale nanopores

In shale gas production, gas composition may vary over time. To understand this phenomenon, we use molecular dynamics simulations to study the permeation of CH 4 , C 2 H 6 and their mixture from a source container through a pyrophyllite nanopore driven by a pressure gradient. For a pure gas, the flow rate of CH 4 is always higher than that of C 2 H 6 , regardless of pore size. For a 1:1 C 2 H 6 : CH 4 mixture, however, C 2 H 6 :CH 4 flow rate ratio is higher than the compositional ratio in the container (i.e., 1:1) when the pore size is smaller than ~1.8 nm. The selective transport is caused by the competitive adsorption of C 2 H 6 over CH 4 in the nanopore. The selectivity is also determined by the interplay between the surface diffusion of the adsorbed molecules and the viscous flow in the center of the pore, and it diminishes as the viscous flow becomes to dominate the surface diffusion when the pore size becomes larger than 1.8 nm. Our work shows that compositional differentiation of shale gas in production is a consequence of nanopore confinement and therefore a key characteristic of an unconventional reservoir. Finally, the related compositional information can potentially be used for monitoring the status of a production well such as its recovery rate.

03 NATURAL GAS↗

Nitrogen p-type doping in polycrystalline zinc selenide telluride films

Nitrogen-doped zinc selenide telluride (N:ZnSe x Te 1−x ) is of interest because it is one of the widest-gap II–VI semiconductors that can still be doped p-type with reasonably high hole concentrations. We sputter deposit N:ZnSe x Te 1−x films, varying Se/(Se + Te), or x, from 0 to 0.7, N 2 flow rate from 0.25 to 0.75 sccm, and substrate temperature from 250 to 370 °C. Increasing x from 0 to 0.39 at the optimal temperature of 370 °C and N 2 flow rate of 0.5 sccm leads to 1.3 atomic % nitrogen incorporation and wurtzite phase stabilization. Such doping and alloying increases hole concentration from 3 × 10 18 cm −3 to 3 × 10 19 cm −3 , although mobility drops from 0.4 to 0.02 cm 2 V −1 s −1 . Our sputtered N:ZnSe 0.38 Te 0.62 has an absorption onset 0.1 eV greater than the ZnTe value of 1.87 eV. Increasing x from 0 to 0.51 enhances transmittance by moving absorption onset from 1.87 to 2.11 eV with diminished band gap bowing likely due to disorder, and increases the work function from 5.12 to 5.42 eV. This combination of tunable properties makes sputtered N:ZnSe x Te 1−x desirable for transparent p-type contacts in polycrystalline Cd(Se,Te) optoelectronic devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Niowave: Flow measurement development - FY2022

It is critical to maintain proper flow rate of lead bismuth eutectic (LBE) for the operation of the Niowave converter. The high temperature of the LBE (> 200 °C) makes it difficult to purchase simple off the shelf flow meters. One method that can be used to measure the flow rate indirectly, is to use a venturi, with a known throat diameter and differential pressure measurement across the throat. LANL designed the venturi and after numerous iterations with vendors, narrowed down a differential pressure transducer to use with the venturi.

43 PARTICLE ACCELERATORS↗

Heat Loss Characteristics and Energy Use of Piperazine with the Advanced Stripper (PZAS) at the UT-SRP Pilot Plant

Heat duty and heat loss were measured at the pilot plant at UT Austin. Heat loss was measured with energy balances using water. Heat loss was studied using surface temperature measurements over 68 different locations at the pilot plant. Surface temperature measurements indicated that bare metal surfaces were the primary source of heat loss from the pilot plant. Heat loss from bare metal surfaces was at least 50% controlled by natural convection and in many cases was as high as 75% natural convection controlled. Measured heat loss at the pilot plant was 20100 BTU/hr and overall heat loss did not show any dependence on the heat rate of the plant. Compared to PZAS™ at the National Carbon Capture Center, heat loss relative to heat rate was higher at 38%. The relative heat loss at the pilot plants was found to decrease by 20% per MW of added capacity. Measured net heat duty was found to be dependent on measured lean loading and cold rich bypass flow rate. Measured net heat duty was between 2.2 and 2.4 GJ/tonne at an optimum lean loading of 0.2–0.21 mol/mol. Data reconciliation by Aspen Plus® Data Fit™ underpredicted CO2 flow rate by 20% due to an overprediction of lean loading by 19%, indicating a necessary change in thermodynamic parameters in the model. This resulted in an over prediction of heat duty by 33% on average.

Amine scrubbing, stripper, energy requirement, hea↗

Predicting Deposition Rate and Closing the Loop on Aerosol Jet Printing with In‐Line Light Scattering Measurements

Aerosol jet printing is a compelling noncontact, digital manufacturing technology for flexible, hybrid, and conformal electronics, but batch‐to‐batch variability and process drift inhibit systematic study and translation to production environments. Emerging measurement techniques for the aerosol volume fraction, a key parameter governing deposition rate, have shown promise for real‐time response, including a recent demonstration of human‐in‐the‐loop control. By integrating improved light scattering measurements with custom software, a robust environment for real‐time monitoring is established and fully automated closed‐loop control over the deposition rate during printing is enabled. The physical basis for scattering measurements as a feedback source is examined and the quantitative insight this provides for ink development and fundamental process studies is highlighted. Three candidate process variables for closed‐loop control, namely the atomizer voltage, carrier gas flow rate, and print speed, are then evaluated. The atomizer voltage demonstrates the best extended duration validity because it addresses atomization variability directly, but carrier gas flow rate and print speed provide faster and more deterministic responses. This methodology is then demonstrated for electrical properties using a silver nanoparticle ink, maintaining 98% of printed patterns within 10% of the mean resistance value over 3 h of printing.

36 MATERIALS SCIENCE↗

In-silico quantification of intersubject variability on aerosol deposition in the oral airway

The extrathoracic oral airway I s not only a major mechanical barrier for pharmaceutical aerosols to reach the lung but also a major source of variability in lung deposition. Using computational fluid dynamics, deposition of 1-30 µm particles was predicted in 11 CT-based models of the oral airways of adults (7 healthy subjects and 4 patients with chronic obstructive pulmonary disease). Simulations were performed for mouth breathing during both inspiration and expiration at two steady-state flow rates representative of resting/light activity (18 L/min) and of that typically used during aerosol inhalation from a dry powder inhaler (45 L/min). For each subject, oral deposition increased with increasing particle size and flow rate. When averaged over all subjects, there was no significant difference in oral deposition efficiency between inspiration and expiration, unlike subregional deposition that show significantly different patterns between the two breathing phases. Consistent with previous in-vitro inspiratory studies, our data showed a large intersubject variability in oral deposition. These results highlight the need for incorporating morphological variation of the upper airway in predictive models of aerosol deposition for accurate predictions of particle dosimetry in the intrathoracic region of the lung.

Computational fluid dynamics (CFD), Inertial impac↗

Geometric Optimization of an Electrochemical Purification Cell to Prevent Corrosion in CSP Plants During Operation

When exposed to moisture or oxygen, molten chloride salts produce corrosive impurities which degrade containment alloys. This can significantly decrease the lifetime and increase costs of molten-salt-based systems. To overcome this barrier, we designed and modeled an electrochemical purification cell to remove the corrosive impurity MgOH+. Various reactor architectures, including continuous stirred tank reactors (CSTRs) and plug flow reactors (PFRs) were investigated. Steady-state thermoelectric properties were evaluated using analytical methods, allowing assessment of the effects of structure and design parameters such as flow rate, cell length, and cross-sectional area of molten salt. The results suggest that our design could most effectively increase reliability and decrease costs of molten-chloride-salt-based systems by protecting them during continuous operation using an annular plug flow reactor.

analytical modeling↗