Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FEET”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Final Rulison Path Forward

The U.S. Department of Energy (DOE) Office of Legacy Management developed this report as a guide for discussions with the Colorado State regulators and other interested stakeholders in response to increased drilling for natural gas reserves near the underground nuclear explosion site at Rulison, Colorado. The Rulison site is located in the Piceance Basin of western Colorado, 40 miles northeast of Grand Junction. The Rulison test was the second natural gas reservoir stimulation experiment in the Plowshare Program, which was designed to develop peaceful uses for nuclear energy. On September 10, 1969, the U.S. Atomic Energy Commission, a predecessor agency of DOE, detonated a 40-kiloton nuclear device 8426 feet below the ground surface in an attempt to release commercially marketable quantities of natural gas. The blast vaporized surrounding rock and formed a cavity about 150 feet in diameter. Although the contaminated materials from drilling operations were subsequently removed from the surface of the blast site, no feasible technology exists to remove subsurface radioactive contamination in or around the test cavity. An increase in drilling for natural gas near the site has raised concern about the possibility of encountering residual radioactivity from the area of the detonation. DOE prohibits drilling in the 40-acre lot surrounding the blast site at a depth below 6000 feet. DOE has no evidence that indicates contamination from the Rulison site detonation has migrated or will ever migrate beyond the 40-acre institutional control boundary. The Colorado Oil and Gas Conservation Commission (COGCC) established two wider boundaries around the site. When a company applies for a permit to drill within a 3-mile radius of surface ground zero, COGCC notifies DOE and provides an opportunity to comment on the application. COGCC also established a half-mile radius around surface ground zero. An application to drill within one-half mile requires a full hearing before the commission. This report outlines DOE's recommendation that gas developers adopt a conservative, staged drilling approach allowing gas reserves near the Rulison site to be recovered in a manner that minimizes the likelihood of encountering contamination. This staged approach calls for collecting data from wells outside the half-mile zone before drilling closer, and then drilling within the half-mile zone in a sequential manner, first at low contamination probability locations and then moving inward. DOE's recommended approach for drilling in this area will protect public safety while allowing collection of additional data to confirm that contamination is contained within the 40-acre institutional control boundary.

54 ENVIRONMENTAL SCIENCES↗

ORNL Parking Structure Mitigation Report

Approximately 200 feet of an unnamed tributary to Fifth Creek and approximately 0.08 acres of wetland were impacted as a result of the construction of a new parking structure at Oak Ridge National Laboratory (ORNL) that was completed in Fiscal Year 2011. Compensatory mitigation, as per requirements set by the Tennessee Department of Environment and Conservation (TDEC), included the following: • On-site expansion of an existing wetland (P2) by 0.04 acres adjacent to the new ORNL parking structure. • On-site enhancement and preservation of approximately 800 feet of First Creek (between White Oak Avenue and West End Circle), 400 feet of White Oak Creek (at Building 4515, the High Temperature Materials Laboratory), and associated riparian zones.

Giffen, Neil R.↗

sRecovery Act: Geologic Characterization of the South Georgia Rift Basin for Source Proximal CO 2 Storage

This study focuses on evaluating the feasibility and suitability of using the Jurassic/Triassic (J/TR) sediments of the South Georgia Rift basin (SGR) for CO 2 storage in southern South Carolina and southern Georgia The SGR basin in South Carolina (SC), prior to this project, was one of the least understood rift basin along the east coast of the U.S. In the SC part of the basin there was only one well (Norris Lightsey #1) the penetrated into J/TR. Because of the scarcity of data, a scaled approach used to evaluate the feasibility of storing CO 2 in the SGR basin. In the SGR basin, 240 km (~149 mi) of 2-D seismic and 2.6 km2 3-D (1 mi2) seismic data was collected, process, and interpreted in SC. In southern Georgia 81.3 km (~50.5 mi) consisting of two 2-D seismic lines were acquired, process, and interpreted. Seismic analysis revealed that the SGR basin in SC has had a very complex structural history resulting the J/TR section being highly faulted. The seismic data is southern Georgia suggest SGR basin has not gone through a complex structural history as the study area in SC. The project drilled one characterization borehole (Rizer # 1) in SC. The Rizer #1 was drilled but due to geologic problems, the project team was only able to drill to 1890 meters (6200 feet) instead of the proposed final depth 2744 meters (9002 feet). The drilling goals outlined in the original scope of work were not met. The project was only able to obtain 18 meters (59 feet) of conventional core and 106 rotary sidewall cores. All the conventional core and sidewall cores were in sandstone. We were unable to core any potential igneous caprock. Petrographic analysis of the conventional core and sidewall cores determined that the average porosity of the sedimentary material was 3.4% and the average permeability was 0.065 millidarcy. Compaction and diagenetic studies of the samples determined there would not be any porosity or permeability at depth in SC. In Georgia there appears to be porosity in the J/TR section based on neutron log porosity values. The only zones in Rizer #1 that appear to be porous were fractured diabase units where saline formation water was flowing into the borehole. Two geocellular models were created for the SC and GA study area. Flow simulation modeling was performed on the SC data set. The injection simulation used the newly acquired basin data as well as the Petrel 3-D geologic model that included geologic structure. Due to the new basin findings as a result of the newly acquired data, during phase two of the modeling the diabase unit was used as reservoir and the sandstone units were used as caprock. Conclusion are: 1) the SGR basin is composed of numerous sub-basins, 2) this study only looked at portions of two sub-basins, 3) in SC, 30 million tonnes of CO 2 can be injected into the diabase units if the fracture network is continuous through the units, 4) due to the severity of the faulting there is no way of assuring the injected CO 2 will not migrate upward into the overlying Coastal Plain aquifers, 5) in Georgia there appears to porous zones in the J/TR sandstones, 6) as in SC there is faulting in the sub-basin and the seismic suggest the faulting extends upward into the Coastal Plain making that area not suitable for CO 2 sequestration, 7) the complex faulting observed at both study areas appear to be associated with transfer fault zones (Heffner 2013), if sub-basins in the Georgia portion of the SGR basin can be located that are far away from the transfer fault zones there is a strong possibility of sequestering CO 2 in these areas, and 9) the SGR basin covers area in three states and this project only studied two small areas so there is enormous potential for CO 2 sequestration in other portions the basin and further research needs to be done to find these areas.

58 GEOSCIENCES↗

Excavationless Exterior Foundation Insulation Field Study

Building science research supports installing exterior (soil side) foundation insulation as the optimal method to enhance the hygrothermal performance of new homes. With exterior foundation insulation, water management strategies are maximized while insulating the basement space and ensuring a more even temperature at the foundation wall. However, such an approach can be very costly and disruptive when applied to an existing home, requiring deep excavation around the entire house. The NorthernSTAR Building America Partnership team implemented an innovative, minimally invasive foundation insulation upgrade technique on an existing home. The approach consisted of using hydrovac excavation technology combined with liquid insulating foam. The team was able to excavate a continuous 4 inches wide by 4 feet to 5 feet deep trench around the entire house, 128 linear feet, except for one small part under the stoop that was obstructed with concrete debris. The combination pressure washer and vacuum extraction technology also enabled the elimination of large trenches and soil stockpiles normally produced by backhoe excavation. The resulting trench was filled with liquid insulating foam, which also served as a water-control layer of the assembly. The insulation was brought above grade using a liquid foam/rigid foam hybrid system and terminated at the top of the rim joist. Cost savings over the traditional excavation process ranged from 23% to 50%. The excavationless process could result in even greater savings since replacement of building structures, exterior features, utility meters, and landscaping would be minimal or non-existent in an excavationless process.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of Advanced Signal Processing Techniques to Improve Detection and Identification of Embedded Defects

By the end of 1996, 109 Nuclear Power Plants were operating in the United States, producing 22% of the Nation’s electricity [1]. At present, more than two thirds of these power plants are more than 40 years old. The purpose of the U.S. Department of Energy Office of Nuclear Energy’s Light Water Reactor Sustainability (LWRS) Program is to develop technologies and other solutions that can improve the reliability, sustain the safety, and extend the operating lifetimes of nuclear power plants (NPPs) beyond 60 years [2]. The most important safety structures in an NPP are constructed of concrete. The structures generally do not allow for destructive evaluation and access is limited to one side of the concrete element. Therefore, there is a need for techniques and technologies that can assess the internal health of complex, reinforced concrete structures nondestructively. Previously, we documented the challenges associated with Non-Destructive Evaluation (NDE) of thick, reinforced concrete sections and prioritized conceptual designs of specimens that could be fabricated to represent NPP concrete structures [3]. Consequently, a 7 feet tall, by 7 feet wide, by 3 feet and 4-inch-thick concrete specimen was constructed with 2.257-inch-and 1-inch-diameter rebar every 6 to 12 inches. In addition, defects were embedded the specimen to assess the performance of existing and future NDE techniques. The defects were designed to give a mix of realistic and controlled defects for assessment of the necessary measures needed to overcome the challenges with more heavily reinforced concrete structures. Information on the embedded defects is documented in [4]. We also documented the superiority of Frequency Banded Decomposition (FBD) Synthetic Aperture Focusing Technique (SAFT) over conventional SAFT when probing defects under deep concrete cover. Improvements include seeing an intensity corresponding to a defect that is either not visible at all in regular, full frequency content SAFT, or an improvement in contrast over conventional SAFT reconstructed images. This report documents our efforts in four fronts: 1) Comparative study between traditional SAFT and FBD SAFT for concrete specimen with and without Alkali-Silica Reaction (ASR) damage, 2) improvement of our Model-Based Iterative Reconstruction (MBIR) for thick reinforced concrete [5], 3) development of a universal framework for sharing, reconstruction, and visualization of ultrasound NDE datasets, and 4) application of machine learning techniques for automated detection of ASR inside concrete. Our comparative study between FBD and traditional SAFT reconstruction images shows a clear difference between images of ASR and non-ASR specimens. In particular, the left first harmonic shows an increased contrast and sensitivity to ASR damage. For MBIR, we show the superiority of model-based techniques over delay and sum techniques such as SAFT. Improvements include elimination of artifacts caused by direct arrival signals, and increased contrast and Signal to Noise Ratio. For the universal framework, we document a format for data storage based on the HDF5 file format, and also propose a modular Graphic User Interface (GUI) for easy customization of data conversion, reconstruction, and visualization routines. Finally, two techniques for ASR automated detection are presented. The first technique is based on an analysis of the frequency content using Hilbert Transform Indicator (HTI) and the second technique employees Artificial Neural Network (ANN) techniques for training and classification of ultrasound data as ASR or non-ASR damaged classes. The ANN technique shows great potential with classification accuracy above 95%. These approaches are extensible to the detection of additional reinforced, thick concrete defects and damage.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Unconfined Compression Results on Core from Borehole U-15n#10, NNSS, in support of SPE

The Nevada National Security Site (NNSS) serves as the geologic setting for a Source Physics Experiment (SPE) program. The SPE provides ground truth data to create and improve strong ground motion and seismic S-wave generation and propagation models. The NNSS was chosen as the test bed because it provides a variety of geologic settings ranging from relatively simple to very complex. Each series of SPE testing will comprise the setting and firing of explosive charges (source) placed in a central borehole at varying depths and recording ground motions in instrumented boreholes located in two rings around the source, positioned at different radii. Modeling using advanced simulation codes will be performed both before and after each test to predict ground response and to improve models based on acquired field data, respectively. A key component in the predictive capability and ultimate validation of the models is the full understanding of the intervening geology between the source and the instrumented boreholes including the geomechanical behavior of the site's rock/structural features. This memorandum reports on an initial phase of unconfined compression testing from corehole U-15n#10. Specimens tested came from the U-15n#10 core hole, which was drilled at -60° to the horizontal in granitic rock (quartz monzonite) after the second SPE shot (SPE-2). Figure 1 illustrates at the surface, the core hole was approximately 90 feet from the central SPE borehole. Corehole U 15n#10 intersects the central SPE borehole (U-15n) at a core depth of 170 feet (approximately 150 feet vertical depth) which is within the highly damaged zone of SPE-2. The U-15n#10 location is the site of the first, second and third SPE's, in Area 15 of the NNSS.

36 MATERIALS SCIENCE↗

Impacts of Standard 90.1-2007 for Commercial Buildings at State Level

This nationwide analysis of commercial energy code compares ASHRAE Standard 90.1-2007 with the commercial code in each state as of June 2009. The results are provided in chapters specific to each state. States with unique energy codes were not included in the analysis because the codes in these states would be difficult to appropriately compare to ASHRAE Standard 90.1 and most of these states have energy offices that routinely assess their codes against the model codes. In states with codes prior to and including the 2000 IECC or Standard 90.1-1999, those states with no statewide energy code, and home rule states which did not specifically request that another code be used, Standard 90.1-1999 was used as the baseline for comparison. Three DOE benchmark buildings were used for the simulation used in this analysis: a medium office building (53,600 square feet), a mid-rise apartment building (33,700 square feet), and a non-refrigerated warehouse (49,500 square feet) - representing ASHRAE Standard 90.1 non-residential, residential, and semi-heated requirements, respectively. Locations for the analysis were selected based on obtaining a sample representative of each climate zone in the state, where typical meteorological year (TMY2) weather file locations existed, making sure to include the state capital. In the absence of a TMY2 weather file for a particular climate zone in a state, a representative location in an adjacent state was used for the purposes of the simulation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Alabama Department of Environmental Management Plugging and Abandonment Report [Well Name/ID: D9-7]

The D 9-7#2 is a UIC Class V injection well (ADEM permit number ALSI9949664), located in Citronelle Oil Field, Citronelle Alabama. The purpose of the well was to inject CO2 into the upper Paluxy formation in an experiment to investigate the potential underground CO2 storage in a deep saline reservoir. A total of 114,104 metric tonnes of CO2 were injected through the D 9-7#2 between August 20, 2012 and September 1, 2014. A minimum three-year post injection site care period began on September 1, 2014. This report summarizes the permanent plugging and abandonment of the D-9-7#2 well. Following the demonstration of CO2 containment and non-endangerment (ref acknowledgement letter from ADEM dated September 27, 2017), Denbury developed a plugging and abandonment (PA) plan for the well. This plan was approved by the Alabama Oil and Gas Board and complies with Denbury’s environmental, health and safety guidelines. The D-9-7#2 well was spud in December 2011 and was drilled to a total depth of 11,790 ft. Prior to the well plugging operations a cement retainer was set in the well casing at 9,336 feet to isolate the injection zone and a 10-feet cement plug was set at 10,790 feet to isolate the oil reservoir, the ‘Donovan’ formation which lies underneath the Paluxy.

01 COAL, LIGNITE, AND PEAT↗

Impact Noise Monitoring at Site 9940: RD-24 Shots

The purpose of this sampling event was to determine if the observation point (inside the MFCP) could be relocated from 74 feet away to 21 feet from ground zero and to determine how much attenuation is provided by the MFCP. The MFCP provides noise attenuation to ensure Members of the Workforce (MOW) exposure to impact noise is below the Occupational Exposure Limit (OEL) of 140 dBC. The MFCP will be used for future tests under similar configurations. Please note that during each test shot, MOW was located inside MFCP that was 74 feet from ground zero and donned hearing protection (e.g., ear plugs with a minimum noise reduction rating of 23).

42 ENGINEERING↗

Petrographic and Advanced Geologic Characterization Report on Lively Grove #1 (API# 1218924947)

Lively Grove #1 (LG1 API number 1218924947) well was drilled to a depth of 5,758 feet, from the Glen Dean Limestone to the top of the Precambrian unit. In total, 49 thin sections were taken from Rotary Sidewall Core (RSWC), and one thin section was taken from Whole Core (2,918 feet, New Albany Shale) from 1,700 to 5,872 feet for this report. This report details specifically thin section point-counting analysis that includes mineralogical and pore space analysis, including grain size analysis annotated thin section photomicrographs, scanning electron microscopy (SEM) with Energy Dispersive x-ray Spectroscopy (EDS), X-ray Diffraction (XRD), statistics of grain size analysis on St. Peter Sandstone thin sections, and Argon-Argon (Ar-Ar) dating on Precambrian samples from LG1. Characterized units include the Salem Limestone, New Albany Shale, Trenton Group, Joachim Dolomite, St. Peter Sandstone, Everton Formation, Eminence Formation, Davis Member, Eau Claire Formation, and Precambrian Basement.

01 COAL, LIGNITE, AND PEAT↗

Data-Driver Interpretation of Ultradeep Azimuthal Propagation

We report the interpretation of geological features around the borehole stresses on the search of true earth model parameters. Different from the conventional logging-while-drilling (LWD) technologies, such as wireline induction and propagation resistivity tools, the azimuthal resistivity measurement acquires the ability of directional sensitivity. Within this decade, this type of tools has been greatly enhanced with over hundred feet depth-of-detection (DoD). To resolve the interpretation of geological features within 100 feet from the borehole, the multiple-layer structure must be considered. However, the traditional methods can never handle the highly nonlinear inverse problems especially facing on the complicated earth structure. Meanwhile, no justifiable uncertainty of inverse parameters can be provided. The statistical methods have been adopted to search for the global statistical distribution and uncertainties of earth model parameters. However, the most attempts are still stuck in non-uniqueness of the solutions since the structure of earth model has been predefined, where the number of layers is assumed, which introduces another ambiguity into the model interpretation. This paper develops a general trans-dimensional Bayesian methodology to solve non-linear inverse problem of earth layer resistivity and depth to the layer boundaries, from the interpretation of ultra-deep azimuthal resistivity measurements. The presented work is a data-driven approach to search out the multi-dimensional parameter spaces. Finally, the simulations tell that the algorithm can efficiently solve the earth model interpretation within a hundred feet from borehole, and examine the uncertainty of earth model parameters.

58 GEOSCIENCES↗

Data for Hadjimichael et al. - Multi-actor, multi-impact scenario discovery

Naming convention for each file is S[scenario_id]_[realization_id].parquet All realizations are generated as per the accompanying paper: Hadjimichael, A., Reed, P.M., Quinn, J.D, Vernon, C.R., Thurber, T., Multi-actor, multi-impact scenario discovery of consequential narrative storylines for human-natural systems planning. Earth's Future (In Review) Each .parquet file contains the following columns: 'structure_id' : StateMod structure ID data corresponds to 'year': simulation year 'month': simulation month 'demand': water demand in acre-feet 'shortage': water shortage in acre-feet 'river_outflow': streamflow in diversion location in acre-feet 'control_location': other structure or reason for shortage

Hadjimichael, Antonia↗

Sensitivity Analysis of Drivers Water Shortage in the Los Angeles Region During Drought

The code and detailed step-by-step instructions for generating the model output data, processing results, and analysis and plotting are provided at https://github.com/IMMM-SFA/Ferencz_et_al_2026_ER_Water. The PyArtes model is a python adaptation of the Artes model. PyArtes uses many of the same input data and optimization model architecture as Artes. Documentation for the PyArtes model is provided in the Supplement to the paper. The primary data product are simulated monthly water shortages for indoor and outdoor demand under a large ensemble of drought scenarios (>13,000). The droughts are hypothetical and are not based on historical time series data of supply sources - though historical data did help inform ranges explored for supply parameters. Demands are informed by recent 2017-2021 water supply data. Demands used for the model can be accessed at https://github.com/IMMM-SFA/Ferencz_et_al_2026_ER_Water. Simulations resolve demand for over 90 water providers in the study region. The results report 36 months of water shortage data for each indoor and outdoor demand node. The study also developed a multilayer perceptron (MLP) neural network trained on a subset of the simulated shortage ensemble to emulate worst annual water shortage for a given set of parameter multipliers -- provided the parameter values fall within the ranges sampled in the ensemble. Emulated water shortages for synthetic ensembles are in the MLP-generated shortages folder. The MLP model was used to generate larger ensembles to support Sobol analysis that would have been extremely computationally expensive to simulate. Datasets provided in this repository*: Simulated shortages. These results are used for the analysis for Figures 5, 8, and 9 in the paper, and also to train the MLP emulator. .zip file containing outputs for the 13,312 scenario ensemble. Separate .csv files for indoor and outdoor shortage for each scenario. Rows = demand ids (~100), Columns = months (36) Units = acre-feet/month of shortage (shortage = monthly demand - supply). 1 acft = 1233.48 m^3 .csv files of aggregated shortages derived from the 13,312 ensemble Rows = scenarios (13,312), Columns = demand ids (~100) Units = acre-feet/year (either worst annual shortage or total shortage over the 3-year drought) .csv file of the parameter multipliers scenarios for the ensemble .csv file of the parameter ranges and baseline values the multipliers were applied to MLP-generated shortages. These results are used for Figures 4, 6, and 7 in the paper. mwd higher folder: scenario ensembles, emulated worst year total shortages (acft), and Sobol results Emulated shortages. Rows = scenarios, columns = demand ids, units acft Sobol results. Rows = demand ids, columns Sobol (S1, ST, or 95% confidence interval) value for each parameter mwd lower folder: scenario ensembles, emulated worst year total shortages (acft), and Sobol results same organization as mwd higher MLP performance: performance metrics (R^2, RMSE, BIAS, MAPE) for the testing subset (20% or 2,662 scenarios) and simulated vs emulated worst year shortage (acre-feet/year) for every demand node, MWD wholesale regions, and the entire study region (LAC). Supporting data for figures. Figure plotting scripts in the associated GitHub repo. These files support analysis and visualization. Geospatial Data used for plotting simulated water shortages and Sobol results. Dictionary of full names for demand nodes in the model and estimates of water supply by source type informed by Artes input files and California Urban Water Management Planning data: https://water.ca.gov/Programs/Water-Use-And-Efficiency/Urban-Water-Use-Efficiency/Urban-Water-Management-Plans *Readme files provided for each folder.

drought↗

Rooftop Photovoltaic Technical Potential in the United States

This data submission contains a workbook with data, and three sets of shapefiles that correspond to that data. The workbook contains data that underlies the 2016 technical report Rooftop Solar Photovoltaic Technical Potential in the United States: A Detailed Assessment. This data is separated into small, medium, and large buildings. A small building is less than 5,000 square feet, a medium building is between 5,000 and 25,000 square feet, and a large building is greater than 25,000 square feet. The suitability of roof area for hosting PV was determined based on shading (energy production not less than 70% of an identical unshaded system in the same location), tilt (no greater than 60 degree tilt), azimuth (not facing north), and contiguous roof area (at least 10 square meters available) criteria. For further documentation of methods and assumptions, see the 2016 report. The tab Rooftop_PV_with_Lidar_Coverage contains estimates for zip codes where at least some lidar data was available. The zip_percentage column indicates the percentage of area of each zip code was covered by lidar data -- only buildings within the covered area are reported here, meaning that the values for incompletely covered zip codes are under-reported. The tab Small_Building_Suitability contains estimates of the number of small buildings and the percentage of those buildings that have at least some area that is suitable for rooftop PV, for all zip codes in the contiguous US. Where lidar data was not available, a model was used to estimate the data. Estimates for medium and large buildings were not produced at the zip code level, because of insufficient input data.

14 SOLAR ENERGY↗

A Preliminary Investigation of the Performance of a Short-length Turbojet Combustor Using Vaporized Hydrocarbon Fuels

Two short turbojet combustors designed for use with vaporized hydrocarbon fuels were tested in a one-quarter annular duct. The experimental combustors consisted of many small "swirl-can" combustor elements manifolded together. This design approach allowed the secondary mixing zone to be considerably reduced over that of conventional combustors. The over-all combustion lengths, for the two configurations were 13.5 and 11.0 inches, approximately one-half the length of the shortest conventional combustors. These short combustors did not provide combustion efficiencies as high as those for conventional combustors at low pressures. However, over the range of combustor-inlet total-pressures expected in aircraft capable of flight at Mach numbers of 2.5 and above, these short combustors gave very high efficiencies. A combustion efficiency of 97 percent was obtained at a combustor-inlet total-pressure of 25.0 inches of mercury absolute, reference velocity of 120 feet per second, and inlet-air total temperature of 1160 deg R. By proportioning the fuel flow between the manifold rows of can combustor elements, control of the combustor-outlet radial total-temperature profile was demonstrated. Combustor totalpressure loss varied from 0.75 percent of the inlet total pressure at isothermal conditions and a reference velocity of 75 feet per second to 5.5 percent at a total-temperature ratio of 1.8 and a reference velocity of 180 feet per second.

Jones, R. E.↗

Lunar surface navigation analysis

The accuracy of the crew position obtained by using a line-of-sight device such as a sun compass or the rover television camera and the prominent mountains such as Hadley and Hadley delta was investigated. It was determined that with errors of 1 deg (noise only), the crew position can be obtained to sigma sub phi = 850 feet and sigma sub lambda = 400 feet using Hadley and Hadley delta. The addition of West Mountain reduced the errors to 600 and 400 feet, respectively.

Savely, R. T.↗

Wagging tail vibration absorber

A 750-foot cantilever length of extendible-tape boom (very low stiffness) was considered as the main system to be damped. A number of tail lengths were tried from 20 feet to 80 feet after which 40 feet was investigated further as a desirable compromise between performance and practical lengths. A 40-foot damping tail produced a damping effect on the main boom for the first mode equivalent in decay rate to 3.1 percent of critical damping. In this case the spring-hinge and tail were tuned to the main boom first mode frequency and the hinge damping was set at 30 percent of critical based on the tail properties. With this same setting, damping of the second mode was .4 percent and the third mode .1 percent.

Barclay, R. G.↗

An 810 ft/sec soil impact test of a 2-foot diameter model nuclear reactor containment system

A soil impact test was conducted on a 880-pound 2-foot diameter sphere model. The impact area consisted of back filled desert earth and rock. The impact generated a crater 5 feet in diameter by 5 feet deep. It buried itself a total of 15 feet - as measured to the bottom of the model. After impact the containment vessel was pressure checked. No leaks were detected nor cracks observed.

Puthoff, R. L.↗