Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Eye Movements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Normative Baseline Oculomotor Performance

Future missions to the moon or Mars will require the crew to monitor and assess their health and performance more autonomously, necessitating approaches that are easily useable and interpretable by non-clinicians. The eye-movement-based performance metrics (oculometrics) obtained from NASA-patented technology developed at the Visuomotor Control Laboratory can reliably detect and discriminate the source of mild neural impairment relative to an individual’s baseline visual and sensorimotor performance and can predict performance in manual control tasks. This study aims to develop a database of normative performance that can be used to enable the detection of impairment without a within-subject baseline and to facilitate power analyses for the design of future studies.

eye movements↗

Do morphemes matter when reading compound words with transposed letters? Evidence from eye-tracking and event-related potentials

We investigate the online processing consequences of encountering compound words with transposed letters (TLs), in order to determine if cross-morpheme TLs are more disruptive to reading than those within a single morpheme, as would be predicted by accounts of obligatory morpho-orthopgrahic decomposition. Two measures of online processing, eye movements and event-related potentials (ERPs), were collected in separate experiments. Participants read sentences containing correctly spelled compound words (cupcake), or compounds with TLs occurring either across morphemes (cucpake) or within one morpheme (cupacke). Results showed that between- and within-morpheme transpositions produced equal processing costs in both measures, in the form of longer reading times (Experiment 1) and a late posterior positivity (Experiment 2) that did not differ between conditions. Our findings converge to suggest that within- and between-morpheme TLs are equally disruptive to recognition, providing evidence against obligatory morpho-orthographic processing and in favour of whole-word access of English compound words during sentence reading.

97 MATHEMATICS AND COMPUTING↗

Oculometric Detection and Characterization of Sub-Clinical Visual/Visuomotor Impairment

It has long been known that qualitative abnormalities in eye movements can be used to diagnose overt brain pathologies (Diefendorf & Dodge, 1908; Fox & Holmes, 1926; Leigh & Zee, 2015). Here, we will examine the use of a set of quantitative measures of the human behavioral response (oculometrics) in a 5-minute radial ocular tracking task (Krukowski & Stone, 2005) with sufficient temporal, spatial, and directional uncertainty to minimize the contribution of a priori prediction or anticipation, and to emphasize the use of a posteriori visual processing of the stimulus trajectory (Liston & Stone, 2014). The derived oculometrics provide a largely independent, reliable set of metrics that are sensitive enough to detect mild sub-clinical impairment across a range of possible neural loci (Stone et al., 2019) with the pattern of impairment across the set providing specificity as to its nature (Tyson et al., 2023). We will review our earlier findings where oculometrics have been used to detect mild impairment due to traumatic brain injury, sleep loss, and low-dose alcohol (Liston et al., 2017; Stone et al., 2019; Tyson et al., 2021). We will also report on a recent clinical study of asymptomatic patients at risk of retinal pathology (Leung et al., 2022) and show that oculometrics can detect and characterize substantive loss of visual function in the absence of clinical indicators of pathology. We conclude that oculometric testing could be used as a routine non-invasive ophthalmological or neurological tool to aid in the early detection and diagnosis of neural injury, toxicity, or disease.

eye movements↗

Effects of spaceflight on ocular counterrolling and the spatial orientation of the vestibular system

We recorded the horizontal (yaw), vertical (pitch), and torsional (roll) eye movements of two rhesus monkeys with scleral search coils before and after the COSMOS Biosatellite 2229 Flight. The aim was to determine effects of adaptation to microgravity on the vestibulo-ocular reflex (VOR). The animals flew for 11 days. The first postflight tests were 22 h and 55 h after landing, and testing extended for 11 days after reentry. There were four significant effects of spaceflight on functions related to spatial orientation: (1) Compensatory ocular counterrolling (OCR) was reduced by about 70% for static and dynamic head tilts with regard to gravity. The reduction in OCR persisted in the two animals throughout postflight testing. (2) The gain of the torsional component of the angular VOR (roll VOR) was decreased by 15% and 50% in the two animals over the same period. (3) An up-down asymmetry of nystagmus, present in the two monkeys before flight was reduced after exposure to microgravity. (4) The spatial orientation of velocity storage was shifted in the one monkey that could be tested soon after flight. Before flight, the yaw axis eigenvector of optokinetic afternystagmus was close to gravity when the animal was upright or tilted. After flight, the yaw orientation vector was shifted toward the body yaw axis. By 7 days after recovery, it had reverted to a gravitational orientation. We postulate that spaceflight causes changes in the vestibular system which reflect adaptation of spatial orientation from a gravitational to a body frame of reference. These changes are likely to play a role in the postural, locomotor, and gaze instability demonstrated on reentry after spaceflight.

Non-NASA Center↗

Correlated Changes in Retinal Thickness and Visuomotor Function in Asymptomatic Plaquenil Toxicity Patients

We have previously shown that a 5-minute eye-movement test can capture a number of largely independent “oculometric” parameters of human visual/visuomotor function (Liston & Stone, 2014). This test has been successfully used to characterize mild neural impairment due to traumatic brain injury, sleep and circadian disruption, and alcohol consumption (Liston et al., 2017; Stone et al, 2019; Tyson et al, 2021). Here, we extend this approach to study patients at risk of progressive posterior-segment illness to see how oculometrics relate to standard clinical ophthalmological measures. Five female patients (<20:40 BCVA, 34-60 years old) undergoing hydroxychloroquine treatment (2-7mg/kg/day for 10-23 years for rheumatologic illness) have participated thus far. Under monocular viewing conditions in randomized order, they tracked a moving spot undergoing radial step-ramp motion in one of 90 randomized directions, at one of 5 randomized speeds, starting at random times (for details, see Stone et al, 2019). We computed nine independent oculometrics (latency, initial acceleration, steady-state gain, proportion smooth, saccadic rate, saccadic amplitude, direction noise, speed responsiveness, and speed noise). Spectral-domain optical coherence tomography (Zeiss, Dublin, CA) was used to measure the average thickness of the nine Early Treatment Diabetic Retinopathy Study macular sectors from the internal limiting membrane to the retinal pigmented epithelium. We used Pearson’s correlation between retinal thickness and our oculometrics with t-statistics to test separate one-sided hypotheses across 10 retinae. Our preliminary analysis found significant changes in several different aspects of visuomotor performance. Most notably, latency increased, initial acceleration decreased, and steady-state pursuit gain decreased as retinal thickness decreased (r2 = 0.364, 0.579, and 0.692; one-tailed P = 0.032, 0.005, and 0.001, respectively). Speed responsiveness appeared to decrease, but this effect was marginal for our current sample (r2 = 0.253, P = 0.069). Lastly, direction discrimination and saccadic behavior appeared unchanged. We conclude that oculometrics may provide sensitive measures of changes in retinal thickness. More importantly, oculometrics have the potential to detect impairment before it becomes evident with standard clinical imaging tools, while also providing insight into the behavioral implications of any resulting deficits in visual/visuomotor function.

eye movements↗

Eye tracking studies based on attentional-resource effectiveness - 310

In the majority of cases, the primary means of information input to operators in nuclear power plants (NPPs) control rooms is through the visual channel. In this study, eye movement patterns of NPP operators are analyzed with eye tracking data obtained from simulator-based experimental studies. Two eye tracking measures of attentional-resource effectiveness in monitoring and detection tasks in NPPs which had been developed by the authors are introduced and several applications with the two eye tracking measures are discussed for the use of the measures. The underlying principle of the measures is that information sources should be selectively attended according to their importance. One of the two measures is the fixation to importance ratio (FIR), which represents attentional resource (eye fixations) spent on an information source compared to the importance of the information source. The other measure is selective attention effectiveness (SAE), which incorporates the FIRs of all information sources. The FIR represents the effectiveness on an information source, whereas the SAE represents the overall effectiveness on all information sources. Frequency and the duration of eye fixations of an operator on information sources are used as attentional resource. Finally feasible future applications with eye tracking data were discussed in terms of plant systems automation and operator training. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Stabilization of gaze during circular locomotion in light. I. Compensatory head and eye nystagmus in the running monkey

1. A rhesus and cynomolgus monkey were trained to run around the perimeter of a circular platform in light. We call this "circular locomotion" because forward motion had an angular component. Head and body velocity in space were recorded with angular rate sensors and eye movements with electrooculography (EOG). From these measurements we derived signals related to the angular velocity of the eyes in the head (Eh), of the head on the body (Hb), of gaze on the body (Gb), of the body in space (Bs), of gaze in space (Gs), and of the gain of gaze (Gb/Bs). 2. The monkeys had continuous compensatory nystagmus of the head and eyes while running, which stabilized Gs during the slow phases. The eyes established and maintained compensatory gaze velocities at the beginning and end of the slow phases. The head contributed to gaze velocity during the middle of the slow phases. Slow phase Gb was as high as 250 degrees/s, and targets were fixed for gaze angles as large as 90-140 degrees. 3. Properties of the visual surround affected both the gain and strategy of gaze compensation in the one monkey tested. Gains of Eh ranged from 0.3 to 1.1 during compensatory gaze nystagmus. Gains of Hb varied around 0.3 (0.2-0.7), building to a maximum as Eh dropped while running past sectors of interest. Consistent with predictions, gaze gains varied from below to above unity, when translational and angular body movements with regard to the target were in opposite or the same directions, respectively. 4. Gaze moved in saccadic shifts in the direction of running during quick phases. Most head quick phases were small, and at times the head only paused during an eye quick phase. Eye quick phases were larger, ranging up to 60 degrees. This is larger than quick phases during passive rotation or saccades made with the head fixed. 5. These data indicate that head and eye nystagmus are natural phenomena that support gaze compensation during locomotion. Despite differential utilization of the head and eyes in various conditions, Gb compensated for Bs. There are various frames of reference in which an estimate of angular velocity that drives the head and eyes could be based. We infer that body in space velocity (Bs) is likely to be represented centrally to provide this signal.

Non-NASA Center↗

Vestibular compensation and orientation during locomotion

Body, head, and eye movements were studied in three dimensions while walking and turning to determine the role of the vestibular system in directing gaze and maintaining spatial orientation. The body, head, and eyes were represented as three-dimensional coordinate frames, and the movement of these frames was related to a trajectory frame that described the motion of the body on a terrestrial plane. The axis-angle of the body, head, and eye rotation were then compared to the axis-angle of the rotation of the gravitoinertial acceleration (GIA). We inferred the role of the vestibular system during locomotion and the contributions of the VCR and VOR by examining the interrelationship between these coordinate frames. Straight walking induced head and eye rotations in a compensatory manner to the linear accelerations, maintaining head pointing and gaze along the direction of forward motion. Turning generated a combination of compensation and orientation responses. The head leads and steers the turn while the eyes compensate to maintain stable horizontal gaze in space. Saccades shift horizontal gaze as the turn is executed. The head pitches, as during straight walking. It also rolls so that the head tends to align with the orientation of the GIA. Head orientation changes anticipate orientation changes of the GIA. Eye orientation follows the changes in GIA orientation so that the net orientation gaze is closer to the orientation of the GIA. The study indicates that the vestibular system utilizes compensatory and orienting mechanisms to stabilize spatial orientation and gaze during walking and turning.

Non-NASA Center↗

Report for 2.2.1 Task 2: Provide execution support for the human factors studies conducted for the LWRS Control Room Modernization project for PVNGS

INL contracted IFE to develop custom software functionality to support INL’s use of eye movement tracking in simulator studies. This includes the support of remote eye trackers, the support of dynamic Areas of Interest based on simulator events, and a general-purpose communication protocol between a simulator and the eye tracking software. The report summarises the task deliverables, which include a requirements identification workshop at INL, a software package, and instructional videos.

99 GENERAL AND MISCELLANEOUS↗

DVA as a Diagnostic Test for Vestibulo-Ocular Reflex Function

The vestibulo-ocular reflex (VOR) stabilizes vision on earth-fixed targets by eliciting eyes movements in response to changes in head position. How well the eyes perform this task can be functionally measured by the dynamic visual acuity (DVA) test. We designed a passive, horizontal DVA test to specifically study the acuity and reaction time when looking in different target locations. Visual acuity was compared among 12 subjects using a standard Landolt C wall chart, a computerized static (no rotation) acuity test and dynamic acuity test while oscillating at 0.8 Hz (+/-60 deg/s). In addition, five trials with yaw oscillation randomly presented a visual target in one of nine different locations with the size and presentation duration of the visual target varying across trials. The results showed a significant difference between the static and dynamic threshold acuities as well as a significant difference between the visual targets presented in the horizontal plane versus those in the vertical plane when comparing accuracy of vision and reaction time of the response. Visual acuity increased proportional to the size of the visual target and increased between 150 and 300 msec duration. We conclude that dynamic visual acuity varies with target location, with acuity optimized for targets in the plane of rotation. This DVA test could be used as a functional diagnostic test for visual-vestibular and neuro-cognitive impairments by assessing both accuracy and reaction time to acquire visual targets.

Wood, Scott J.↗

Using Eye-Tracking to Quantify Reverse Engineering Expertise

Software reverse engineering (RE) requires analysts to closely read and make decisions about code. Little is known about what makes an analyst successful, making it difficult to train new analysts or design tools to augment existing ones. The goal of this project was to quantify the eye movement behaviors supporting RE and code comprehension more generally. We applied eye-tracking methods from the language comprehension literature to understand where analysts direct their attention over time when completing tasks (e.g., function identification, bug detection). Across three studies, we manipulated aspects of code hypothesized to impact comprehension (e.g., variable name meaningfulness, code complexity) and presentation methods (e.g., line-by-line, free viewing, gaze-contingent moving window) to understand effects on accuracy and gaze patterns. Results showed clear benefits of meaningful variable names, and effects of expertise on global and line-specific viewing patterns. Findings could inspire empirically-supported tool or analytic adaptations that help to reduce analyst workload.

97 MATHEMATICS AND COMPUTING↗

High-Procession Eye Tracking Using Fundus Images

Fundus images provide high optical gain for eye movement tracking, i.e. large image displacements occur as a result of small eye rotations. Subpixel registration techniques can provide resolution better than 1 arc minute using images acquired with a CCD camera. Ocular torsion may also be estimated, with a precision of approximately 0.1 degree. This talk will discuss the software algorithms used to attain this performance.

Mulligan, Jeffrey B.↗

Comparison of Predictable Smooth Ocular and Combined Eye-Head Tracking Behaviour in Patients with Lesions Affecting the Brainstem and Cerebellum

We compared the ability of eight normal subjects and 15 patients with brainstem or cerebellar disease to follow a moving visual stimulus smoothly with either the eyes alone or with combined eye-head tracking. The visual stimulus was either a laser spot (horizontal and vertical planes) or a large rotating disc (torsional plane), which moved at one sinusoidal frequency for each subject. The visually enhanced Vestibulo-Ocular Reflex (VOR) was also measured in each plane. In the horizontal and vertical planes, we found that if tracking gain (gaze velocity/target velocity) for smooth pursuit was close to 1, the gain of combined eye-hand tracking was similar. If the tracking gain during smooth pursuit was less than about 0.7, combined eye-head tracking was usually superior. Most patients, irrespective of diagnosis, showed combined eye-head tracking that was superior to smooth pursuit; only two patients showed the converse. In the torsional plane, in which optokinetic responses were weak, combined eye-head tracking was much superior, and this was the case in both subjects and patients. We found that a linear model, in which an internal ocular tracking signal cancelled the VOR, could account for our findings in most normal subjects in the horizontal and vertical planes, but not in the torsional plane. The model failed to account for tracking behaviour in most patients in any plane, and suggested that the brain may use additional mechanisms to reduce the internal gain of the VOR during combined eye-head tracking. Our results confirm that certain patients who show impairment of smooth-pursuit eye movements preserve their ability to smoothly track a moving target with combined eye-head tracking.

Grant, Michael P.↗

Measuring Human Performance in Simulated Nuclear Power Plant Control Rooms Using Eye Tracking

Control room modernization will be an important part of life extension for the existing light water reactor fleet. As part of modernization efforts, personnel will need to gain a full understanding of how control room technologies affect performance of human operators. Recent advances in technology enables the use of eye tracking technology to continuously measure an operator’s eye movement, which correlates with a variety of human performance constructs such as situation awareness and workload. This report describes eye tracking metrics in the context of how they will be used in nuclear power plant control room simulator studies.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The Vestibular System and Human Dynamic Space Orientation

The motion sensors of the vestibular system are studied to determine their role in human dynamic space orientation and manual vehicle control. The investigation yielded control models for the sensors, descriptions of the subsystems for eye stabilization, and demonstrations of the effects of motion cues on closed loop manual control. Experiments on the abilities of subjects to perceive a variety of linear motions provided data on the dynamic characteristics of the otoliths, the linear motion sensors. Angular acceleration threshold measurements supplemented knowledge of the semicircular canals, the angular motion sensors. Mathematical models are presented to describe the known control characteristics of the vestibular sensors, relating subjective perception of motion to objective motion of a vehicle. The vestibular system, the neck rotation proprioceptors and the visual system form part of the control system which maintains the eye stationary relative to a target or a reference. The contribution of each of these systems was identified through experiments involving head and body rotations about a vertical axis. Compensatory eye movements in response to neck rotation were demonstrated and their dynamic characteristics described by a lag-lead model. The eye motions attributable to neck rotations and vestibular stimulation obey superposition when both systems are active. Human operator compensatory tracking is investigated in simple vehicle orientation control system with stable and unstable controlled elements. Control of vehicle orientation to a reference is simulated in three modes: visual, motion and combined. Motion cues sensed by the vestibular system through tactile sensation enable the operator to generate more lead compensation than in fixed base simulation with only visual input. The tracking performance of the human in an unstable control system near the limits of controllability is shown to depend heavily upon the rate information provided by the vestibular sensors.

VESTIBULAR APPARATUS↗

Moving Ahead With Eye Power

NASA's Jet Propulsion Laboratory's collaborated with LC Technologies, Inc., to improve LCT's Eyegaze Communication System, an eye tracker that enables people with severe cerebral palsy, muscular dystrophy, multiple sclerosis, strokes, brain injuries, spinal cord injuries, and ALS (amyotrophic lateral sclerosis) to communicate and control their environment using their eye movements. To operate the system, the user sits in front of the computer monitor while the camera focuses on one eye. By looking at control keys on the monitor for a fraction of a second, the user can 'talk' with speech synthesis, type, operate a telephone, access the Internet and e-mail, and run computer software. Nothing is attached to the user's head or body, and the improved size and portability allow the system to be mounted on a wheelchair. LCT and JPL are working on several other areas of improvement that have commercial add-on potential.

Source record↗

SU-G-IeP4-09: Method of Human Eye Aberration Measurement Using Plenoptic Camera Over Large Field of View

Purpose: The measurement based on Shack-Hartmann wave-front sensor(WFS), obtaining both the high and low order wave-front aberrations simultaneously and accurately, has been applied in the detection of human eyes aberration in recent years. However, Its application is limited by the small field of view (FOV), slight eye movement leads the optical bacon image exceeds the lenslet array which result in uncertain detection error. To overcome difficulties of precise eye location, the capacity of detecting eye wave-front aberration over FOV much larger than simply a single conjugate Hartmann WFS accurately and simultaneously is demanded. Methods: Plenoptic camera’s lenslet array subdivides the aperture light-field in spatial frequency domain, capture the 4-D light-field information. Data recorded by plenoptic cameras can be used to extract the wave-front phases associated to the eyes aberration. The corresponding theoretical model and simulation system is built up in this article to discuss wave-front measurement performance when utilizing plenoptic camera as wave-front sensor. Results: The simulation results indicate that the plenoptic wave-front method can obtain both the high and low order eyes wave-front aberration with the same accuracy as conventional system in single visual angle detectionand over FOV much larger than simply a single conjugate Hartmann systems. Meanwhile, simulation results show that detection of eye aberrations wave-front in different visual angle can be achieved effectively and simultaneously by plenoptic method, by both point and extended optical beacon from the eye. Conclusion: Plenoptic wave-front method possesses the feasibility in eye aberrations wave-front detection. With larger FOV, the method can effectively reduce the detection error brought by imprecise eye location and simplify the eye aberrations wave-front detection system comparing with which based on Shack-Hartmann WFS. Unique advantage of the plenoptic method lies in obtaining wave-front in different visual angle simultaneously, which provides an approach in building up 3-D model of eye refractor tomographically. Funded by the key Laboratory of High Power Laser and Physics, CAS Research Project of National University of Defense Technology No. JC13-07-01; National Natural Science Foundation of China No. 61205144.

60 APPLIED LIFE SCIENCES↗