Characterization of the low electric field and zero-temperature two-level-system loss in hydrogenated amorphous silicon
Not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not provided.
This study investigates the high-temperature electrical properties and microstructural characteristics of brazed joints combining La₀.₈Sr₀.₂CrO₃ (LSC) with nickel and nickel-based alloys. Using nickel-based filler metals (NB LM and NB 130), the joints were tested in controlled atmospheres (95% N₂ and 5% H₂). Electrical resistivity was analyzed across a range of temperatures (25–727°C), and contact resistance was evaluated using a composite model. Results indicate that joint resistance decreases with increasing temperature, with optimal brazing achieved at 1160°C. Diffusion processes involving Si, Ni, O, and Sr were identified, with silicon oxide formation contributing to joint bonding.
Numerous efficient semiconductors suffer from instability in aqueous electrolytes. Strategies utilizing protective coatings have thus been developed to protect these photoabsorbers against corrosion while synergistically improving charge separation and reaction kinetics. Recently, various photoelectrochemical (PEC) protective coatings have been reported with suitable electronic properties to ensure low charge transport loss and reveal the fundamental photoabsorber efficiency. However, protocols for studying the critical figures of merit for protective coatings have yet to be established. For this reason, we propose four criteria for evaluating the performance of a protective coating for PEC water-splitting: stability, conductivity, optical transparency, and energetic matching. We then propose a flow chart that summarizes the recommended testing protocols for quantifying these four performance metrics. In particular, we lay out the stepwise testing protocols to evaluate the energetics matching at a semiconductor/coating/(catalyst)/liquid interface. Finally, we provide an outlook for the future benchmarking needs for coatings.
Web Dendritic Si ribbons are deformed under a well-defined four point bending stress. Since the mechanical properties of Si are known to depend on the 0 content of the material, 0 measurements using Fourier Transform Infrared Spectroscopy were done to determine a proper control sample of non-defected single crystal Si. Four point bending revealed a unique two step bending behavior for the Web Si ribbons. An initial theory for this behavior involves the interaction of the dislocations generated by the deformation with the central twin planes of the ribbons. Measurements showed a uniformly high 0 content for the Web Si ribbons, approximately 10 to the 18th power atoms/cu.cm. The Web samples had a much broader absorption peak at 9 microns than is usually seen for well-annealed single crystal Si. This broadening is thought to be related to stress in the Web Si ribbons. Two samples containing a known amount of residual stress support this hypothesis. Also, a shoulder on the infrared absorption peak associated with interstitial 0 in Si appears in the transmission vs. wavenumber plots for some of the Web samples. This shoulder has been associated with 0-vacancy complexes or with 0 at dislocations. The O content and configuration do not seem to correlate with the growth configuration of the Web Si ribbon.
Rocket-based instrumentation investigations of middle atmospheric electrodynamics during thunderstorms were conducted in coordination with balloon-measurements at Wallops Island, Virginia. Middle atmosphere electrodynamics and energy coupling are of particular importance to associated electrical processes at lower and higher altitudes. Objectives of this research effort included: (1) investigation of thunderstorm effects on middle atmosphere electrical structure, including spatial and temporal dependence; (2) characterization of electric field transients and the associated energy deposited at various altitudes; (3) evaluation of the vertical Maxwell current density over a thunderstorm to study the coupling of energy to higher altitudes; and (4) investigation of the coupling of energy to the ionosphere and the current supplied to the 'global circuit.'
An acousto-electric levitator has been developed to study the behavior of liquid drop and solid particle clusters and arrays. Unlike an ordinary acoustic levitator that uses only a standing acoustic wave to levitate a single drop or particle, this device uses an extra electric static field and the acoustic field simultaneously to generate and levitate charged drops in two-dimensional arrays in air without any contact to a solid surface. This cluster and array generation (CAG) instrument enables us to steadily position drops and arrays to study the behavior of multiple drop and particle systems such as spray and aerosol systems relevant to the energy, environmental, and material sciences.
Presently, thermal neutron detectors fabricated from boron-10 enriched hexagonal boron nitride (h-10BN) ultrawide bandgap semiconductor grown by metal organic chemical vapor deposition (MOCVD) hold the record high detection efficiency among all solid-state detectors at 59%. To overcome the short comings of MOCVD growth, including inherently low growth rate and unavoidable impurities such as carbon in metal organic source, we demonstrate here the growth of natural hexagonal boron nitride (h-BN) semi-bulk wafers using halide vapor phase epitaxy (HVPE), which is an established technique for producing GaN semi-bulk crystals at a high growth rate. Electrical transport characterization results revealed that these HVPE grown materials possess an electrical resistivity of 1 × 1013 Ω cm, and a charge carrier mobility and lifetime product of 2 × 10−4 cm2/V s. Detectors fabricated from a 100 μm thick h-BN wafer have demonstrated a thermal neutron detection efficiency of 20%, corresponding to a charge collection efficiency of ∼60% at an operating voltage of 500 V. This initial demonstration opens the door for mass producing high efficiency h-BN semiconductor neutron detectors at a reduced cost, which could create unprecedented applications in nuclear energy, national security, nuclear waste monitoring and management, the health care industry, and material sciences.
Ultrawide bandgap (UWBG) semiconductors inherently exhibit very high electrical resistivities. This property presents not only challenges in probing their electrical transport properties but also difficulties to fabricate, understand, and characterize the electrical properties of metal contacts on these materials. Here, we report the measurements and analysis of the applied electric field dependence of photocurrent to reveal the effect of metal contacts on the transport properties of highly resistive h-BN. Our results indicate that even for h-BN with a room temperature resistivity as high as 1014 Ω cm, the as-deposited metal contact is not a completely blocking type as commonly assumed in previous analyses for other large bandgap insulating materials. By modifying the boundary condition between the metal/semiconductor interface, a quantitative description has been obtained, which can be used to determine if the metal contact is Ohmic or blocking type. This quantitative description should be applicable to all UWBG semiconductors with extremely high electrical resistivities. The work also provides a better understanding of how the metal contact type affects the transport properties of UWBG semiconductors in general.
This paper presents a process for characterizing the oscillatory dynamics of a large bulk power system. As a demonstration, the process is applied to the Western Interconnection of North America. Several complementary analysis approaches, both new and existing, are employed to provide a comprehensive understanding of the oscillatory properties of the system. Established modal analysis techniques based on ringdown and mode-meter algorithms are utilized. In addition, we derive and apply methods based on spectral correlation analysis to identify modal frequencies, distinguish between modes that are closely spaced in frequency, and determine locations at which the modes are observable. Critical interarea modes are identified and characterized using actual-system synchrophasor measurements taken over several years of operation in concert with industry-standard simulation models. This includes 145 hours of PMU data and two planning base cases.
During the fall of 1988, a Schweizer 845 airplane equipped to measure electric field and other meteorological parameters flew over Kennedy Space Center in a program to study clouds defined in the existing launch retriction requirements. The special purpose test vehicle for atmospheric research (SPTVAR) was suitable for flights through thunderclouds and was instrumented to measure all three components of the ambient electric vector. The main goals of the project were: (1) to develop and demonstrate techniques for measuring the electric field aloft and locate regions of charge during flight; (2) to characterize the electrical conditions within and near clouds that are presently identified as a threat to space launch vehicles; and (3) to study the correlation between the electric field aloft and that at Kennedy Space Center's ground-based field mill network for a variety of electrified clouds.
This work evaluates the feasibility to extend spread spectrum time-domain reflectometry (SSTDR) and frequency domain reflectometry (FDR) electrical cable testing to characterize whether an electrical cable is submerged in water or not and where it may be submerged. Using PNNL’s ARENA cable and motor test bed, shielded and non-shielded electrical cables were evaluated using SSTDR and FDR methods to detect and locate electrical cable exposure to water. Both SSTDR and FDR showed the presence of water with a non-shielded cable. Moisture was only detectable with the shielded cable if the insulation was damaged.
The amount of upward current provided to the ionosphere by a thunderstorm that appeared over the Kennedy Space Center (KSC) on July 11, 1978, is reexamined using an analytic equation that describes a bipolar thunderstorm's current contribution to the global circuit in terms of its generator current, lightning currents, the altitudes of its charge centers, and the conductivity profile of the atmosphere. Ground-based measurements, which were obtained from a network of electric field mills positioned at various distances from the thunderstorm, were used to characterize the electrical activity inside the thundercloud. The location of the lightning discharges, the type of lightning, and the amount of charge neutralized during this thunderstorm were computed through a least squares inversion of the measured changes in the electric fields following each lightning discharge. These measurements provided the information necessary to implement the analytic equation, and consequently, a time-averaged estimate of this thunderstorm's current contribution to the global circuit was calculated. From these results the amount of conduction current supplied to the ionosphere by this small thunderstorm was computed to be less than 25% of the time-averaged generator current that flowed between the two vertically displaced charge centers.
Flights made by the Special Purpose Test Vehicle for Atmospheric Research (SPTVAR) airplane during a second deployment to Florida during the summer of 1989 are discussed. The findings based on the data gathered are presented. The progress made during the second year of the project is discussed. The summer 1989 study was carried out with the support and guidance of Col. John Madura, Commander of Detachment 11, 2nd Weather Squadron, USAF, at Patrick Air Force Base (PAFB) and Cape Canaveral Air Force Station. The project goals were to develop and demonstrate techniques for measuring the electric field aloft and locating regions of charge during flight within and near clouds; to characterize the electric conditions that are presently identified as a threat to space launch vehicles; and to study the correlation between the electric field aloft and that at Kennedy Space Center's ground-based electric field mill array for a variety of electrified clouds.
We present the design, experimental procedure, and experimental evaluation of a system for fast, simple, and ex situ characterization of electrical conductivity of slurry electrode materials. The system uses a custom-designed electrochemical cell compatible with centrifugation in a swing-bucket centrifuge. The cell features cylindrical graphite electrodes that are partially sheathed so as to expose only 2 mm of the electrode surface to the bottom region of the packed particulate pellet. Also presented is a conduction model that provides a shape factor for estimating effective conductivity. We tested aqueous solutions of carbon black (CB), activated carbon (AC), and mixtures thereof. These particles were dispersed in 0.0 and 0.5 M NaCl solutions. Measurements show that the effective conductivity initially increases linearly with pellet mass and then saturates at higher masses. Notably, CB exhibited a fivefold increase in conductivity than AC at equal pellet masses. CB/AC mixtures at a fixed pellet mass were tested with CB mass fractions of 0 to 100%. Interestingly, the mixture conductivity was found to be a non-monotonic function of CB mass fraction, with a maximum conductivity at about 60 % CB mass fraction. At this maximum, the mixture conductivity is approximately 30 % higher than pure CB. NaCl concentration in the slurry solution had no effects on conductivity. These results highlight the interactions between slurry electrode composition and compaction, offering insights for optimizing slurry electrodes. Furthermore, the system and results may also be applicable to evaluation of particulate materials (including slurries) used for Li-ion batteries, capacitive deionization, fuel cells, and flow electrodes.
A NASA Langley Research Center Learjet 28 research airplane was flown in various adverse weather conditions in the vicinity of the NASA Kennedy Space Center from 1990-1992 to measure airborne electric fields during the Joint NASA/USAF Airborne Field Mill Program. The objective of this program was to characterize the electrical activity in various weather phenomena common to the NASA-Kennedy area in order to refine Launch Commit Criteria for natural and triggered lightning. The purpose of the program was to safely relax the existing launch commit criteria, thereby increasing launch availability and reducing the chance for weather holds and delays. This paper discusses the operational conduct of the flight test, including environmental/safety considerations, aircraft instrumentation and modification, test limitations, flight procedures, and the procedures and responsibilities of the personnel in the ground station. Airborne field mill data were collected for all the Launch Commit Criteria during two summer and two winter deployments. These data are now being analyzed.
The initial phase of a broader, more complete program for the characterization of electrical breakdowns on spacecraft insulating materials is described which consisted of the development of a discharge simulator and characterization facility and the performance of a limited number of discharge measurements to verify the operation of the laboratory setup and to provide preliminary discharge transient field data. A preliminary model of the electromagnetic characteristics of the discharge was developed. It is based upon the "blow off" current model of discharges, with the underlying assumption of a propagating discharge. The laboratory test facility and discharge characterization instrumentation are discussed and the general results of the "quick look" tests are described on quartz solar reflectors aluminized Kapton and silver coated Teflon are described.
NLR's advanced power electronics and electric machines (APEEM) research group develops world-class experimental and modeling capabilities to design and evaluate efficient and reliable power electronics and electric machines, as well as innovative thermal management systems to maximize their performance. They also design, fabricate, and characterize advanced power electronics packaging and are developing state-of-health monitoring techniques.