Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “EVAPORATION RATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Pressurization of a Flightweight, Liquid Hydrogen Tank: Evaporation and Condensation at a Liquid Vapor Interface

Evaporation and condensation at a liquid-vapor interface is important for long-term, in-space cryogenic propellant storage. Yet the current understanding of inter-facial physics does not consistently predict behavior of evaporation or condensation rates. The proposed paper will present a physical model, based on the 1-D Heat equation and Schrage's equation, which demonstrates thin thermal layers at the fluid vapor interface.

cryogenic hydrogen↗

Control of solvent evaporation in hen egg white lysozyme crystallization

An investigation of the role of solvent evaporation in tetragonal lysozyme crystallization was preformed with a device that employs N2(g) to control the evaporation of solvent from a micro-volume crystallization hanging drop. The number of crystals was found to vary with the rate at which the final supersaturation level was achieved. It was found that the more rapid the approach to supersaturation the larger the number of crystals. Accordingly, the crystals reached a smaller terminal size. Elongation of the (110) face parallel to the four-fold axis was observed with the slower evaporation rates.

Wilson, L. J.↗

Evaluating the Impacts of NASA/SPoRT Daily Greenness Vegetation Fraction on Land Surface Model and Numerical Weather Forecasts

The NASA Short-term Prediction Research and Transition (SPoRT) Center has developed a Greenness Vegetation Fraction (GVF) dataset, which is updated daily using swaths of Normalized Difference Vegetation Index data from the Moderate Resolution Imaging Spectroradiometer (MODIS) data aboard the NASA EOS Aqua and Terra satellites. NASA SPoRT began generating daily real-time GVF composites at 1-km resolution over the Continental United States (CONUS) on 1 June 2010. The purpose of this study is to compare the National Centers for Environmental Prediction (NCEP) climatology GVF product (currently used in operational weather models) to the SPoRT-MODIS GVF during June to October 2010. The NASA Land Information System (LIS) was employed to study the impacts of the SPoRT-MODIS GVF dataset on a land surface model (LSM) apart from a full numerical weather prediction (NWP) model. For the 2010 warm season, the SPoRT GVF in the western portion of the CONUS was generally higher than the NCEP climatology. The eastern CONUS GVF had variations both above and below the climatology during the period of study. These variations in GVF led to direct impacts on the rates of heating and evaporation from the land surface. In the West, higher latent heat fluxes prevailed, which enhanced the rates of evapotranspiration and soil moisture depletion in the LSM. By late Summer and Autumn, both the average sensible and latent heat fluxes increased in the West as a result of the more rapid soil drying and higher coverage of GVF. The impacts of the SPoRT GVF dataset on NWP was also examined for a single severe weather case study using the Weather Research and Forecasting (WRF) model. Two separate coupled LIS/WRF model simulations were made for the 17 July 2010 severe weather event in the Upper Midwest using the NCEP and SPoRT GVFs, with all other model parameters remaining the same. Based on the sensitivity results, regions with higher GVF in the SPoRT model runs had higher evapotranspiration and lower direct surface heating, which typically resulted in lower (higher) predicted 2-m temperatures (2-m dewpoint temperatures). Portions of the Northern Plains states experienced substantial increases in convective available potential energy as a result of the higher SPoRT/MODIS GVFs. These differences produced subtle yet quantifiable differences in the simulated convective precipitation systems for this event.

Bell, Jordan R.↗

Observation of chromospheric evaporation during the Solar Maximum Mission

A study is presented of the upward motions of part of the soft X-ray emitting plasma using data for flares collected in 1980 by the Bent Crystal Spectrometer and the Hard X-ray Burst Spectrometer on the Solar Maximum Mission satellite. Results show that upward motions of the soft X-ray plasma are temporally associated with the build up of the thermal phase of flares and with the period of energy deposition as indicated by the hard X-ray emission. In addition, it is found that the hardness of the hard X-ray spectrum, the evaporation velocity, and the rate of increase of the gradual phase are correlated. It is also possible that the total electron energy deposited in the chromosphere, the peak emission measure of the evaporating plasma, and the peak emission measure of the thermal coronal plasma may also be correlated.

Antonucci, E.↗

Limits on supernova rates and interstellar densities from X-ray observations of M101

Measurements of the X-ray surface brightness of a face-on disk galaxy M101 have previously been used to place upper limits on the power radiated by a hot corona. Such analysis constrains the effective density of the disk; either it must be so low that the remnants drive a fast hot wind (low radiated power), or so high that the remnant temperature at overlap is low (low X-ray power). These X-ray measurements are here used to constrain the properties of the population of supernova remnants evolving in the disk. This adds a further constraint since young remnants evolving in higher density radiate more of their energy in X-rays, whether or not they eventually overlap to generate a hot corona. The strength of this second limit depends strongly on the density history of the remnants (e.g., evaporative vs. nonevaporative evolution) and on the assumed supernova rate. For evaporative evolution the analysis rules out the McKee (1977) and Ostriker (1977) interstellar medium model in particular and evaporative evolution in general unless the supernova rate is at least several times lower than current expectations. For standard Sedov evolutions, the density limit marginally admits 0.2/cu cm, a popular alternative to the McKee and Ostriker model.

Cox, D. P.↗

Combustion of LOX with H2(sub g) under subcritical, critical, and supercritical conditions and experimental observation of dense spray and mixing of impinging jets

Progress made during the period of February 1 to October 15, 1992 is reported. The overall objective of Task 1 of the investigation is to achieve a better understanding of the combustion processes of liquid oxygen and gaseous hydrogen under subcritical, critical, and supercritical conditions. Specific objectives of the research program are: (1) to determine the evaporation- and burning-rate characteristics of LOX in hydrogen/helium environments under broad ranges of operating conditions; (2) to measure species concentration profile and surface temperature of LOX employing the gas chromatography and fine-wire thermocouples under non-reacting flow situations; (3) to perform a fugacity-based multicomponent thermodynamic phase equilibrium analysis for examining the high-pressure vapor-liquid equilibrium behavior at the liquid surface of LOX; (4) to formulate and solve a theoretical model for simulating the evaporation and combustion processes in a LOX/H2/He system; and (5) to validate the theoretical model with the measured experimental data. Task 2 of the investigation is described. Observation of a like-on-like injector element in the near-injector region performed in the previous phase of this project has identified the existence of a high Reynolds number regime in which the pre-impingement jets are fully turbulent and undergoing surface breakup. The new spray regime, which has not been observed by previous investigators, is characterized by the presence of many fine droplets and the disappearance of the well-defined liquid breakup wave pattern in the post-impingement region. It is speculated that a cavitating region may be present within the orifice so that it could induce strong turbulence, leading to an onset of atomization of the jets prior to impingement. To further investigate the dense spray behavior of the impinging jets in the high Reynolds number region, experiments were conducted using Plexiglas injector components for direct internal flow observation. The main objective is to determine under what conditions a cavitating region would form and whether or not the cavitation is reponsible for the development of the high Reynolds number spray regime. The procedure and major findings of the injector cavitation study are described.

Kuo, Kenneth K.↗

A Study of Nucleate Boiling with Forced Convection in Microgravity

Boiling is a rather imprecise term applied to the process of evaporation in which the rate of liquid-vapor phase change is large. In seeking to determine the role and significance of body forces on the process, of which buoyancy or gravity is just one agent, it becomes necessary to define the term more precisely. It is generally characterized by the formation and growth of individual vapor bubbles arising from heat transfer to the liquid, either at a solid/liquid or liquid/liquid interface, or volumetrically. The terms 'bubble' boiling and 'nucleate' boiling are frequently used, in recognition of the interactions of surface tension and other forces in producing discrete bubbles at distinctive locations (although not always). Primary considerations are that evaporation can occur only at existing liquid-vapor interfaces, so that attention must be given to the formation of an interface (the nucleation process), and that the latent heat for this evaporation can come only from the superheated liquid, so that attention must also be given to the temperature distributions in the liquid.

Merte, Herman, Jr.↗

Atmospheric Pressure Effects on Cryogenic Storage Tank Boil-Off

The Cryogenics Test Laboratory (CTL) at the Kennedy Space Center (KSC) routinely utilizes cryostat test hardware to evaluate comparative and absolute thermal conductivities of a wide array of insulation systems. The test method is based on measurement of the flow rate of gas evolved due to evaporative boil-off of a cryogenic liquid. The gas flow rate typically stabilizes after a period of a couple of hours to a couple of days, depending upon the test setup. The stable flow rate value is then used to calculate the thermal conductivity for the insulation system being tested. The latest set of identical cryostats, 1,000-L spherical tanks, exhibited different behavior. On a macro level, the flow rate did stabilize after a couple of days; however the stable flow rate was oscillatory with peak to peak amplitude of up to 25 percent of the nominal value. The period of the oscillation was consistently 12 hours. The source of the oscillation has been traced to variations in atmospheric pressure due to atmospheric tides similar to oceanic tides. This paper will present analysis of this phenomenon, including a calculation that explains why other cryostats are not affected by it.

Sass, J. P.↗

Flow Visualization in Evaporating Liquid Drops and Measurement of Dynamic Contact Angles and Spreading Rate

A new hybrid optical system, consisting of reflection-refracted shadowgraphy and top-view photography, is used to visualize flow phenomena and simultaneously measure the spreading and instant dynamic contact angle in a volatile-liquid drop on a nontransparent substrate. Thermocapillary convection in the drop, induced by evaporation, and the drop real-time profile data are synchronously recorded by video recording systems. Experimental results obtained from this unique technique clearly reveal that thermocapillary convection strongly affects the spreading process and the characteristics of dynamic contact angle of the drop. Comprehensive information of a sessile drop, including the local contact angle along the periphery, the instability of the three-phase contact line, and the deformation of the drop shape is obtained and analyzed.

Zhang, Neng-Li↗

The Question of Future Droughts in a CO2-Warmed World

Increased droughts are to be expected in a warmer world, and so are increased floods. A warmer atmosphere can hold more moisture, and evaporate more water from the surface. Thus, when it is not raining, available soil water should be reduced. When it is raining, it could very well rain harder. Most researchers agree then that a warmer world will have greater hydrologic extremes. In addition, there is a basic imbalance that develops as climate warms, between the loss of moisture from the soil by evaporation and replenishment via precipitation. The land has a smaller heat capacity than the ocean, so it should warm faster. Evaporation from the land proceeds at the rate of its warming, while precipitation derives primarily from evaporation at the ocean surface. As the latter is increasing more slowly, in a warmer world, precipitation will not increase as rapidly as evaporation due to the fact that the oceans warm more slowly than the land surface (evaporation over the ocean is slower than over the land). Hence, more droughts are anticipated in a warmer world, but the specific location of such droughts is somewhat uncertain. To address the question of where droughts are likely to occur, one first needs to have a reasonable sense of what the future magnitude of warming will be, and what the latitudinal distribution of warming will be. For example, the greater the warming at high latitudes relative to low latitudes, the more likely there will be increased drought over the U.S. in summer. In contrast, substantial tropical warming could give us El Nino-like precipitation, with intensified flooding along the southern tier of the U.S. All of these conditions are likely to intensify as the global temperature rises.

Rind, David↗

Estimation of Transpiration and Water Use Efficiency Using Satellite and Field Observations

Structure and function of terrestrial plant communities bring about intimate relations between water, energy, and carbon exchange between land surface and atmosphere. Total evaporation, which is the sum of transpiration, soil evaporation and evaporation of intercepted water, couples water and energy balance equations. The rate of transpiration, which is the major fraction of total evaporation over most of the terrestrial land surface, is linked to the rate of carbon accumulation because functioning of stomata is optimized by both of these processes. Thus, quantifying the spatial and temporal variations of the transpiration efficiency (which is defined as the ratio of the rate of carbon accumulation and transpiration), and water use efficiency (defined as the ratio of the rate of carbon accumulation and total evaporation), and evaluation of modeling results against observations, are of significant importance in developing a better understanding of land surface processes. An approach has been developed for quantifying spatial and temporal variations of transpiration, and water-use efficiency based on biophysical process-based models, satellite and field observations. Calculations have been done using concurrent meteorological data derived from satellite observations and four dimensional data assimilation for four consecutive years (1987-1990) over an agricultural area in the Northern Great Plains of the US, and compared with field observations within and outside the study area. The paper provides substantive new information about interannual variation, particularly the effect of drought, on the efficiency values at a regional scale.

Choudhury, Bhaskar J.↗

Climate and atmospheric modeling studies. Climate applications of Earth and planetary observations. Chemistry of Earth and environment

The research conducted during the past year in the climate and atmospheric modeling programs concentrated on the development of appropriate atmospheric and upper ocean models, and preliminary applications of these models. Principal models are a one-dimensional radiative-convective model, a three-dimensional global climate model, and an upper ocean model. Principal applications have been the study of the impact of CO2, aerosols and the solar 'constant' on climate. Progress was made in the 3-D model development towards physically realistic treatment of these processes. In particular, a map of soil classifications on 1 degree x 1 degree resolution has been digitized, and soil properties have been assigned to each soil type. Using this information about soil properties, a method was developed to simulate the hydraulic behavior of soils of the world. This improved treatment of soil hydrology, together with the seasonally varying vegetation cover, will provide a more realistic study of the role of the terrestrial biota in climate change. A new version of the climate model was created which follows the isotopes of water and sources of water (or colored water) throughout the planet. Each isotope or colored water source is a fraction of the climate model's water. It participates in condensation and surface evaporation at different fractionation rates and is transported by the dynamics. A major benefit of this project has been to improve the programming techniques and physical simulation of the water vapor budget of the climate model.

Source record↗

Carbon Nanotubes in Water: MD Simulations of Internal and External Flow, Self Organization

We have developed computational tools, based on particle codes, for molecular dynamics (MD) simulation of carbon nanotubes (CNT) in aqueous environments. The interaction of CNTs with water is envisioned as a prototype for the design of engineering nano-devices, such as artificial sterocillia and molecular biosensors. Large scale simulations involving thousands of water molecules are possible due to our efficient parallel MD code that takes long range electrostatic interactions into account. Since CNTs can be considered as rolled up sheets of graphite, we expect the CNT-water interaction to be similar to the interaction of graphite with water. However, there are fundamental differences between considering graphite and CNTs, since the curvature of CNTs affects their chemical activity and also since capillary effects play an important role for both dynamic and static behaviour of materials inside CNTs. In recent studies Gordillo and Marti described the hydrogen bond structure as well as time dependent properties of water confined in CNTs. We are presenting results from the development of force fields describing the interaction of CNTs and water based on ab-initio quantum mechanical calculations. Furthermore, our results include both water flows external to CNTs and the behaviour of water nanodroplets inside heated CNTs. In the first case (external flows) the hydrophobic behaviour of CNTs is quantified and we analyze structural properties of water in the vicinity of CNTs with diagnostics such as hydrogen bond distribution, water dipole orientation and radial distribution functions. The presence of water leads to attractive forces between CNTs as a result of their hydrophobicity. Through extensive simulations we quantify these attractive forces in terms of the number and separation of the CNT. Results of our simulations involving arrays of CNTs indicate that these exhibit a hydrophobic behaviour that leads to self-organising structures capable of trapping water clusters. In the second case (internal flows) we study the behaviour of water droplets confined inside CNTs. Constant temperature simulations allow us to capture structural properties such as the contact angles and density profiles of the equilibrated drops. By heating and subsequently cooling of the CNT, we are able to measure the evaporation and the condensation rate of the entrapped water.

Jaffe, Richard L.↗

Construction of a Penrose Diagram for a Spatially Coherent Evaporating Black Hole

A Penrose diagram is constructed for an example black hole that evaporates at a steady rate as measured by a distant observer, until the mass vanishes, yielding a final state Minkowski space-time. Coordinate dependencies of significant features, such as the horizon and coordinate anomalies, are clearly demonstrated on the diagram. The large-scale causal structure of the space-time is briefly discussed.

Brown, Beth A.↗

Design of the Brine Evaporation Bag for Increased Water Recovery in Microgravity

The existing water recovery system on the International Space Station (ISS) is limited to 75% reclamation; consequently, long duration space missions are currently unfeasible due to the large quantity of water necessary to sustain the crew. The Brine Evaporation Bag (BEB) is a proposed system to supplement the existing water recovery system aboard the ISS that can to increase water recovery to 99%. The largest barrier to high water recovery is mineral scaling inside the water recovery equipment, which leads to equipment failure; therefore, some water must remain to keep the minerals dissolved. This waste stream is liquid brine containing salts, acids, organics, and water. The BEB is designed to recover this remaining water while protecting the equipment from scale. The BEB consists of a sealed bag containing a hydrophobic membrane that allows water vapor and gas to pass through. It is operated under vacuum, heated, and continuously filled with brine to boil away the water. The water vapor is recovered and the solids are contained inside the bag for disposal. The BEB can dry the brine to a solid block. Ongoing work includes improving the design of the BEB and the evaporator to prevent leaks, maximize the rate of water removal, and minimize energy use and weight. Additional testing will determine whether designs are heat- or mass-transfer limited and the optimal water recovery rate.

Brine Evaporation Bag↗

Lean Blowout (LBO) Simulations in a Rich-Burn Quick-Quench Lean-Burn (RQL) Gas Turbine Combustor

The transient processes involving lean blowout (LBO) in a RQL combustor such as the single cup combustor in the National Jet Fuels Combustion Program (NJFCP) referee rig are simulated with the reduced mechanisms based on Hybrid Chemistry for two different fuels, Cat-A2 and Cat-C1. Cat-A2 fuel is Jet-A with average or nominal properties based on a survey of the Petroleum Quality Information System database. The Cat-C1, an alternative jet fuel, is a GEVO alcohol-to-jet (ATJ) fuel composed almost entirely of two highly-branched C12 and C16 iso-paraffins. Experiments conducted in the NJFCP referee rig established a stable flame at an equivalence ratio of 0.096 (the near LBO condition) as the starting condition for LBO tests performed with all Category A and C fuels. Simulations of the approach to LBO verify that a stable flame is established at the near-LBO condition for each fuel before reducing fuel flow rate (and thus equivalence ratio) in a step-wise manner. At each new equivalence ratio, the global heat release rate and total fuel evaporation time histories are monitored to verify a new stable flame condition has been established before performing the next reduction in equivalence ratio until the flame is approaching the blowout. Main conclusions are threefold: (1) For Cat-C1 fuel the equivalence ratio for LBO is around 0.087. (2) For Cat-A2 fuel the equivalence ratio for LBO is either 0.082 or 0.078 depended on the time span of equivalence ratio of 0.085. (3) The averaged difference from LES on LBO for Cat-C1 relative to Cat-A2 is 8.75% versus 7.8% from the experimental data.

LES, Lean blow out↗

Evaporator film coefficients of grooved heat pipes

The heat transfer rate in the meniscus attachment region of a grooved heat pipe evaporator is studied theoretically. The analysis shows that the evaporation takes place mainly in the region where the liquid changes its shape sharply. However, comparisons with available heat transfer data indicate that the heat transfer rate in the meniscus varying region is substantially reduced probably due to groove wall surface roughness.

Kamotani, Y.↗

Clogging of Manifolds with Evaporatively Frozen Propellants: Analysis - Part 2

The mechanisms of evaporative freezing of leaking propellant and the creation of flow stoppages within injector manifolds is discussed. A quantitative analysis of the conditions, including the existence of minimum and maximum leak rates, for the accumulation of evaporatively frozen propellant is presented. Clogging of the injector manifolds of the Apollo SPS and the Gemini OAMS engines by the freezing of leaking propellant is predicted and the seriousness of the consequences are discussed. Based on the analysis a realistic evaluation of selected techniques to eliminate flow stoppages by frozen propellant is made.

Simmon, J. A.↗