Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTROMAGNETIC MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

A Demonstration of Light-Augmented Calorimetry For Low-Energy Electrons in Liquid Argon.

The ability to resolve electrons with energies as low as 5 MeV in liquid argon (LAr) is important for future studies of astrophysical neutrinos in liquid argon time projection chambers (LArTPCs). Existing methods for measuring the energy of electromagnetic showers in LArTPCs rely solely on charge-based reconstruction which requires correcting for assumed electron-ion recombination. However, LAr scintillation light has the potential to improve energy reconstruction over charge-based measurements alone. Here we present a demonstration of a light-augmented calorimetric technique for low-energy electrons in LAr that foregoes the need to correct for recombination. A sample of Michel electrons from stopping cosmic muons is collected in LArIAT (Liquid Argon In A Testbeam), a single-phase LArTPC at Fermilab’s Test Beam Facility. Michel electron energy spectra are reconstructed using both a traditional charge-based approach as well as a more holistic approach that incorporates both charge and light. A maximum-likelihood fitter, using LArIAT’s well-tuned simulation, is developed for combining these quantities to achieve optimal energy resolution. A sample of isolated electrons with Ee < 60 MeV is then simulated to better determine the energy resolution of this topology. Due to LArIAT’s low wire noise, the addition of light is not found to significantly improve upon the achieved charged-based resolution of σ/E ≃ 9%/√E ⊕ 1%. However, additional samples are generated with varying wire noise levels and light yields to gauge the impact of light-augmented calorimetry in large LArTPCs such as DUNE and SBND. At a charge-readout signal-to-noise of ≈10, the energy resolution for low-energy electrons is improved by ∼15%, ∼25%, and ∼45% over charge-only calorimetry for average light yields of 10, 20, and 100 pe/MeV, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Progress in the Construction and Testing of the Tianlai Radio Interferometers

The Tianlai Pathfinder is designed to demonstrate the feasibility of using a wide field of view radio interferometers to map the density of neutral hydrogen in the Universe after the Epoch of Reionizaton. This approach, called 21~cm intensity-mapping, promises an inexpensive means for surveying the large-scale structure of the cosmos. The Tianlai Pathfinder presently consists of an array of three, 15~m $\times$ 40~m cylinder telescopes and an array of sixteen, 6~m diameter dish antennas located in a radio-quiet part of western China. The two types of arrays were chosen to determine the advantages and disadvantages of each approach. The primary goal of the Pathfinder is to make 3D maps by surveying neutral hydrogen over large areas of the sky %$20,000 {\rm deg}^2$ in two different redshift ranges: first at $1.03 > z > 0.78$ ($700 - 800$~MHz) and later at $0.21 > z > 0.12$ ($1170 - 1270$~MHz). The most significant challenge to $21$~cm intensity-mapping is the removal of strong foreground radiation that dwarfs the cosmological signal. It requires exquisite knowledge of the instrumental response, i.e. calibration. In this paper, we provide an overview of the status of the Pathfinder and discuss the details of some of the analysis that we have carried out to measure the beam function of both arrays. We compare electromagnetic simulations of the arrays to measurements, discuss measurements of the gain and phase stability of the instrument, and provide a brief overview of the data processing pipeline.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hand-held UXO Discriminator

With prior funding (UX-1225, MM-0437, and MM-0838), we have successfully designed and built a cart-mounted Berkeley UXO Discriminator (BUD) and demonstrated its performance at various test sites (e.g., Gasperikova et al., 2007, 2009). It is a multi-transmitter multi-receiver active electromagnetic system that is able to discriminate UXO from scrap at a single measurement position, hence eliminates equirement of a very accurate sensor location. The cart-mounted system comprises of three orthogonal transmitters and eight pairs of differenced receivers (Smith et al., 2007). Receiver coils are located on ymmetry lines through the center of the system and see identical fields during the on-time of the pulse in all of the transmitter coils. They can then be wired in opposition to produce zero output during the n-ime of the pulses in three orthogonal transmitters. Moreover, this configuration dramatically reduces noise in the measurements by canceling the background electromagnetic fields (these fields are uniform ver the scale of the receiver array and are consequently nulled by the differencing operation), and by canceling the noise contributed by the tilt of the receivers in the Earth's magnetic field, and therefore reatly enhances receivers sensitivity to the gradients of the target.

54 ENVIRONMENTAL SCIENCES↗

Development of an MCP-Based Timing Layer for the LHCb ECAL Upgrade-2

The increase in instantaneous luminosity during the high-luminosity phase of the LHC represents a significant challenge for future detectors. A strategy to cope with high-pileup conditions is to add a fourth dimension to the measurements of the hits, by exploiting the time separation of the various proton–proton primary collisions. According to LHCb simulation studies, resolutions of about 10–20 picoseconds, at least an order of magnitude shorter than the average time span between primary interactions, would be greatly beneficial for the physics reach of the experiment. Microchannel plate (MCP) photomultipliers are compact devices capable of measuring the arrival time of charged particles with the required resolution. The technology of large-area picosecond photodetectors (LAPPDs) is under investigation to implement a timing layer that can be placed within a sampling calorimeter module with the purpose of measuring the arrival time of electromagnetic showers. LAPPD performances, using a Gen-I tile with a delay-line anode and a Gen-II with a capacitively coupled anode, have been measured thoroughly both with laser (wavelength of 405 nm and pulse width of 27.5 ps FWHM) and high-energy electron (1–5.8 GeV) beams. Time resolutions of the order of 30 ps for single photoelectrons and 15 ps for electromagnetic showers initiated by 5-GeV electrons, as measured at the shower maximum, are obtained.

47 OTHER INSTRUMENTATION↗

Reactor Power Level Estimation by Fusing Multi-Modal Sensor Measurements

Estimates of the power level of a nuclear reactor based on measurements from an independent monitoring sensor system can help in the compliance verification of its declared operations. We present a three-level fusion method to estimate the power level of a nuclear reactor using features derived from infrared, electromagnetic, and acoustic sensor measurements collected in proximity to the reactor. Based on a simplified analytical model of the secondary coolant system of the reactor, we identify partial regression functions of the power level in terms of the temperature difference between inlet and outlet of coolant pipes, and the activity levels of four fans and four pumps, which are estimated as features from the sensor measurements. The power level estimator employs a combination of aggregate and complementary fusion steps at three levels to incorporate the multi-modal features in a structure that reflects the secondary cooling system and its partial regression functions. Using the measurements from a test campaign at an operational reactor, we show that this estimator achieves 3.47% or lower root mean square error under 5-fold cross validation. More generally, these results illustrate a progressive reduction in estimation error as additional modalities are appropriately incorporated, and that the fuser outperforms single modality features and their sub-combinations.

Rao, Nageswara↗

Time domain-induced polarization geophysical data collected in the Rifle Floodplain, Colorado, USA

The IP data set was collected using a time domain-induced polarization (TDIP) method along 65 profiles of various lengths over the floodplain. Surface time domain?induced polarization (TDIP) data was collected to create the 3?D images of the complex electrical resistivity, in terms of magnitude and phase, which are associated with mineral precipitation and other lithological properties. The TDIP data was then used to estimate the spatial distribution of naturally reduced zones, which are known to be biogeochemical hotspots in floodplains having increased uranium and other redox-sensitive metal concentrations as well as high carbon contents. In the TDIP method, the transient decay of voltage is measured after current shut-off, typically in the form of an integral of decay curves over a predefined time window (so-called integral chargeability). TDIP measurements at the site were collected using the Syscal Iris Pro Switch equipment with a square-wave current injection, 50% duty cycle, and a pulse length of 2 s. The integral chargeability measurements were carried out using 20 windows during voltage decay between 240 and 1840 ms after current shut-off. Tomographic measurements were collected by deploying stainless steel electrodes with an electrode separation of 1.8 m and using a dipole-dipole ‘‘skip-2’’ and ‘‘skip-3’’ measuring protocol (i.e., for a dipoles length of 5.4 and 7.2 m, respectively). The sequence of dipole-dipole measurements was carefully arranged to (1) minimize unwanted electromagnetic coupling effects in the data, avoiding potential measurements with electrodes located inside the current dipole, (2) prevent voltage measurements using electrodes, which might be polarized due to previous current injection, and (3) increase the signal-to-noise ratio for an intended exploration depth of 8 m, i.e., the bottom of the aquifer. All measurements were collected as normal and reciprocal pairs for estimation of the data error. The IP measurements were collected with symmetric arrays (i.e., the measuring equipment placed at the center of the electrode array) with a maximum of 36 electrodes, considering that longer profiles revealed a significant increase in the normal-reciprocal misfit for the measurements of the decay curve, probably due to greater impact of electromagnetic coupling on the data. The TDIP data sets were inverted in a twodimensional domain along each transect using CRTomo, which is a smoothness-constraint inversion code based on a finite element algorithm. The resistivity and phase shift values at each pixel were then assigned at the corresponding point within the 3-D floodplain domain (the black rectangle Figure 1b) and used in the 3-D estimation. The TDIP inversion results provided the distribution of the complex resistivity, expressed in terms of its magnitude and phase-shift. The analysis of the normal-reciprocal misfit was used to estimate the relative error. We removed the measurement with smallest voltage difference (<2 mV), representing about 2% variations in the data. For the inversion of TDIP measurements, chargeability values were linearly converted to frequency domain phase values (at the fundamental frequency of 0.125 Hz), by assuming a constant-phase response. This approach has been demonstrated to provide consistent results in previous studies

54 ENVIRONMENTAL SCIENCES↗

Polarimetry-Interferometry Diagnostic for Magnetic Field and Magnetic Fluctuation Measurements in High-Performance and Long-Pulse Tokamaks (Final Report)

In this grant, we executed a multi-year plan to develop an advanced Faraday-effect polarimeter-interferometer system to address both fluctuation and equilibrium diagnostic needs by providing a measurement of the plasma internal magnetic field fluctuations (including non-axisymmetric 3-D perturbations) and plasma vertical position. This diagnostic included both fast time response and low phase noise so that both the temporal dynamics of equilibrium quantities as well as high-frequency electromagnetic fluctuations could be measured simultaneously, adding new and unique measurement capabilities for the core of high-temperature plasmas. The combined polarimeter-interferometer diagnostic development was applied primarily to the tokamak magnetic configuration, focusing on high-performance regimes including H-mode, reversed shear advanced tokamak scenarios, and non-inductive current drive.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reconstructing the neutron-star equation of state from astrophysical measurements

The properties of matter at ultrahigh densities, low temperatures, and with a significant asymmetry between protons and neutrons can be studied exclusively through astrophysical observations of neutron stars. We show that measurements of the masses and radii of neutron stars can lead to tight constraints on the pressure of matter at three fiducial densities, from 1.85 to 7.4 times the density of nuclear saturation, in a manner that is largely model independent and that captures the key characteristics of the equation of state. We demonstrate that observations with 10% uncertainties of at least three neutron stars can lead to measurements of the pressure at these fiducial densities with an accuracy of 0.11 dex or {approx_equal}30%. Observations of three neutron stars with 5% uncertainties are sufficient to distinguish at a better than 3{sigma} confidence level between currently proposed equations of state. In the electromagnetic spectrum, such accurate measurements will become possible for weakly magnetic neutron stars during thermonuclear flashes and in quiescence with future missions such as the International X-ray Observatory.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sea-ice thickness from field measurements in the northwestern Barents Sea: SEA-ICE THICKNESS, NW BARENTS SEA

The Barents Sea is one of the fastest changing regions of the Arctic, and has experienced the strongest decline in winter-time sea-ice area in the Arctic, at 22364% decade21. Sea-ice thickness in the Barents Sea is not well studied. We present two previously unpublished helicopter-borne electromagnetic(HEM) ice thickness measurements from the northwestern Barents Sea acquired in March 2003 and 2014.The HEM data are compared to ice thickness calculated from ice draft measured by ULS deployed between1994 and 1996. These data show that ice thickness varies greatly from year to year; influenced by the thermodynamic and dynamic processes that govern local formation vs long-range advection. In a year with a large inflow of sea-ice from the Arctic Basin, the Barents Sea ice cover is dominated by thick multiyear ice;as was the case in 2003 and 1995. In a year with an ice cover that was mainly grown in situ, the ice will be thin and mechanically unstable; as was the case in 2014. The HEM data allow us to explore the spatial and temporal variability in ice thickness. In 2003 the dominant ice class was more than 2 years old; and modal sea-ice thickness varied regionally from 0.6 to 1.4 m, with the thinner ice being either irst-year ice, or multiyear ice which had come into contact with warm Atlantic water. In 2014 the ice cover was predominantly locally grown ice less than 1 month old (regional modes of 0.5–0.8 m). These two situations represent two extremes of a range of possible ice thickness distributions that can present very different conditions for shipping traffic; or have a different impact on heat transport from ocean to atmosphere.

54 ENVIRONMENTAL SCIENCES↗

Transport and Non-Invasive Position Detection of Electron Beams from Laser-Plasma Accelerators

The controlled imaging and transport of ultra-relativistic electrons from laser-plasma accelerators is of crucial importance to further use of these beams, e.g. in high peak-brightness light sources. We present our plans to realize beam transport with miniature permanent quadrupole magnets from the electron source through our THUNDER undulator. Simulation results demonstrate the importance of beam imaging by investigating the generated XUV-photon flux. In addition, first experimental findings of utilizing cavity-based monitors for non-invasive beam-position measurements in a noisy electromagnetic laser-plasma environment are discussed.

43 PARTICLE ACCELERATORS↗

Instrument for spatially resolved simultaneous measurements of forces and currents in particle beams

The article presents a device for spatially resolved and simultaneous measurements of forces and currents in particle beams, especially in beams composed of ions and neutral atoms. The forces are exerted by the impinging beam particles on a plane circular conductive target plate of 20 mm diameter mounted on a pendulum with electromagnetic force compensation. The force measurement in the micronewton range is achieved by electromagnetic compensation by means of static Helmholtz coils and permanent magnets attached to the pendulum. Exemplary measurements are performed in the 1.2 keV beam of a broad beam ion source. The simultaneous measurements of forces and currents onto the same target are compared with each other and with Faraday cup measurements.

43 PARTICLE ACCELERATORS↗

Study of the e + e - → K + K - reaction in the energy range from 2.6 to 8.0 GeV

The e + e - →K + K - cross section and charged-kaon electromagnetic form factor are measured in the e + e - center-of-mass energy range (E) from 2.6 to 8.0 GeV using the initial-state radiation technique with an undetected photon. The study is performed using 469 fb-1 of data collected with the BABAR detector at the PEP-II2 e + e - collider at center-of-mass energies near 10.6 GeV. The form factor is found to decrease with energy faster than 1/E 2 and approaches the asymptotic QCD prediction. Production of the K + K - final state through the J/ψ and ψ(2S) intermediate states is observed. The results for the kaon form factor are used together with data from other experiments to perform a model-independent determination of the relative phases between electromagnetic (single-photon) and strong amplitudes in J/ψ and ψ(2S)→K + K - decays. The values of the branching fractions measured in the reaction e + e - →K + K - are shifted relative to their true values due to interference between resonant and nonresonant amplitudes. The values of these shifts are determined to be about ±5% for the J/ψ meson and ±15% for the ψ(2S) meson.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Position dependent optical coupling between single quantum dots and photonic crystal nanocavities

We demonstrate precise and quick detection of the positions of quantum dots (QDs) embedded in two-dimensional photonic crystal nanocavities. We apply this technique to investigate the QD position dependence of the optical coupling between the QD and the nanocavity. We use a scanning electron microscope (SEM) operating at a low acceleration voltage to detect surface bumps induced by the QDs buried underneath. This enables QD detection with a sub-10 nm precision. We then experimentally measure the vacuum Rabi spectra to extract the optical coupling strengths (gs) between single QDs and cavities, and compare them to the values estimated by a combination of the SEM-measured QD positions and electromagnetic cavity field simulations. We found a highly linear relationship between the local cavity field intensities and the QD-cavity gs, suggesting the validity of the point dipole approximation used in the estimation of the gs. The estimation using SEM has a small standard deviation of ±6.2%, which potentially enables the high accuracy prediction of g prior to optical measurements. Our technique will play a key role for deeply understanding the interaction between QDs and photonic nanostructures and for advancing QD-based cavity quantum electrodynamics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A novel technique to measure interface trap density in a GaAs MOS capacitor using time-varying magnetic fields

Interface trap density (D{sub it}) in a GaAs metal-oxide-semiconductor (MOS) capacitor can be measured electrically by measuring its impedance, i.e. by exciting it with a small signal voltage source and measuring the resulting current through the circuit. We propose a new method of measuring D{sub it} where the MOS capacitor is subjected to a (time-varying) magnetic field instead, which produces an effect equivalent to a (time-varying) voltage drop across the sample. This happens because the electron chemical potential of GaAs changes with a change in an externally applied magnetic field (unlike that of the gate metal); this is not the voltage induced by Faraday’s law of electromagnetic induction. So, by measuring the current through the MOS, D{sub it} can be found similarly. Energy band diagrams and equivalent circuits of a MOS capacitor are drawn in the presence of a magnetic field, and analyzed. The way in which a magnetic field affects a MOS structure is shown to be fundamentally different compared to an electrical voltage source.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Phase control of the Pancharatnam phase

We propose a method to control the atomic dynamics in the presence of electromagnetic fields. Instead of measuring the population dynamics, we focus on the possibility of controlling the Pancharatnam phase. For a two-level system we find that this phase can be optically induced and controlled by the phase shift. More importantly, the nonlinear interaction between the atom and the field leads to an enhanced sensitivity for the control of the atomic phase evolution and system dynamics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nucleon Structure Studies at Jefferson Lab and the Electron Ion Collider

The research programs of Thomas Jefferson Laboratory (JLab) and the future Electron- Ion Collider (EIC) focus on one of the main goals of strong interaction studies : understanding the structure of nucleons in terms of the quarks and gluons composing them. Their structure is encoded in functions such as Generalized Parton Distributions (GPDs), which describe how quarks and gluons’ transverse position and longitudinal momentum are distributed inside nucleons. GPDs allow to obtain three-dimensional pictures of nucleons and to understand some of their fundamental properties, such as their internal pressure or the emergence of their spin from the dynamics of the partons composing them. At JLab and the EIC, electron beams are used to probe nucleons. Measurement of reactions such as Deeply Virtual Compton Scattering (DVCS) allows access to GPDs. The first longitudinally polarized-target experiment of the CLAS12 program at Jlab took place in 2022-2023. Combining polarized electron beams and nucleon targets, this experiment offers unique access to observables that allow the measurement of different types of GPDs. In particular, the DVCS beam- and target-spin asymmetries for protons and neutrons in deuterium will be measured for the first time. They give access to kinds of GPDs that are still poorly known, and the comparison between proton and neutron data will allow the extraction of the flavor dependence of the structure of nucleons. Specific analysis methods have been implemented to work with a polarized nuclear target and are presented in this thesis. These methods allow to obtain preliminary results for the asymmetries, waiting for the complete statistics to be available. In the long term, the experimental program for the EIC has been established with a strong emphasis on the measurement of the structure of nucleons at high energy. Measurements of reactions such as DVCS impose strict requirements on the electromagnetic calorimeter that will allow to measure the energy of the scattered electrons and photons. This calorimeter, which is under development, will be based on scintillating crystals read by Silicon Photomultipliers (SiPMs). A new type of glass-based scintillating material was tested, evaluating the possibilities to meet the technical requirements concerning their light yield and resistance to radiation damage in particular. Several models of SiPMs have been characterized, demonstrating they can operate over the vast energy range necessary to address the physics case at the EIC and providing guidelines for developing their readout electronics.

Pilleux, Noemie↗

London Penetration Depth Measurements Using Tunnel Diode Resonators

The London penetration depth λ is the basic length scale for electromagnetic behavior in a superconductor. Precise measurements of λ as a function of temperature, field and impurity scattering have been instrumental in revealing the nature of the order parameter and pairing interactions in a variety of superconductors discovered over the past decades. Here we recount our development of the tunnel-diode resonator technique to measure λ as function of temperature and field in small single crystal samples. Furthermore, we discuss the principles and applications of this technique to study unconventional superconductivity in the copper oxides and other materials such as iron-based superconductors. The technique has now been employed by several groups world-wide as a precision measurement tool for the exploration of new superconductors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗