Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “EA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Male Runners With Lower Energy Availability Have Impaired Skeletal Integrity Compared to Nonathletes

Abstract Context Female athletes, particularly runners, with insufficient caloric intake for their energy expenditure [low energy availability (EA) or relative energy deficiency] are at risk for impaired skeletal integrity. Data are lacking in male runners. Objective To determine whether male runners at risk for energy deficit have impaired bone mineral density (BMD), microarchitecture, and estimated strength. Design Cross-sectional. Setting Clinical research center. Participants 39 men (20 runners, 19 controls), ages 16–30 years. Main Outcome Measures Areal BMD (dual-energy x-ray absorptiometry); tibia and radius volumetric BMD and microarchitecture (high-resolution peripheral quantitative computed tomography); failure load (microfinite element analysis); serum testosterone, estradiol, leptin; energy availability. Results Mean age (24.5 ± 3.8 y), lean mass, testosterone, and estradiol levels were similar; body mass index, percent fat mass, leptin, and lumbar spine BMD Z-score (−1.4 ± 0.8 vs −0.8 ± 0.8) lower (P < .05); and calcium intake and running mileage higher (P ≤ .01) in runners vs controls. Runners with EA <median had lower lumbar spine (−1.5 ± 0.7, P = .028), while runners with EA ≥median had higher hip (0.3 ± 0.7 vs −0.4 ± 0.5, P = .002), BMD Z-scores vs controls. After adjusting for calcium intake and running mileage, runners with EA <median had lower mean tibial total and trabecular volumetric BMD, trabecular bone volume fraction, cortical porosity, and apparent modulus vs controls (P < .05). Appendicular lean mass and serum estradiol (R ≥ 0.45, P ≤ .046), but not testosterone, were positively associated with tibial failure load among runners. Conclusions Despite weight-bearing activity, skeletal integrity is impaired in male runners with lower caloric intake relative to exercise energy expenditure, which may increase bone stress injury risk. Lower estradiol and lean mass are associated with lower tibial strength in runners.

Haines, Melanie S. (ORCID:0000000310024754)↗

Ionization potential and electron affinity for six common explosive compounds by DFT, MP2, and CBS-QB3

The vertical and adiabatic ionization potential (IP V and IP A ) and vertical electron affinity (EA V ) for six explosives (RDX, HMX, TNT, PETN, HMTD, and TATP) have been studied by ab initio computational methods. The IPV was calculated using MP2 and CBS-QB3 while the IP A was calculated with B3LYP, CAM-B3LYP, ω B97XD, B2PLYP, and MP2. RDX and TNT IP A ’s were also reported using CBS -QB3. Excluding results by CBS-QB3, B3LYP and B2PLYPD provided superior and more consistent results for calculating the IP. The EA V were calculated using the same methods however B3LYP performed the worst in this case with MP2 and B2PLYPD predicting values closest to those made by CBS-QB3, which was used a reference due to lacking experimental data. Basis set effects were evaluated using 6- 31+G(d,p), 6-311+G(d,p), and 6-311+(3df,2p) for both IP and EA. 6-31+G(d,p) gave satisfactory results for calculating both IP however 6-311+G(3df,2p) had improved results in calculating the EA. The four nitro containing compounds had exothermic reduction potentials while the peroxides were unfavorable. Additionally, it was seen that RDX, HMX, TATP and HMTD were unstable in their reduced forms. Results are aimed to assist detection and screening methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Energy Auditor and Quality Control Inspector Competency Model

The Energy Auditor (EA) and Quality Control Inspector (QCI) Competency model was developed to identify the soft skills, foundational competencies and define the levels of Knowledge, Skills, and Abilities (KSAs) required to successfully perform the tasks defined in the EA and QCI Job Task Analysis (JTAs), the U.S. Department of Energy (DOE) used the U.S. Department of Labor's (DOL) Competency Model Clearinghouse resources to develop a QCI and EA Competency Model. To keep the QCI and EA competency model consistent with other construction and energy management competency models, DOE and the National Renewable Energy Laboratory used the existing 'Residential Construction Competency Model' and the 'Advanced Commercial Building Competency Model' where appropriate.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Carbon, Nitrogen, and Sulfur Analysis of the Cetama Viognier Standard Reference Material

The Viognier sample was analyzed for C, N, and S concentrations and stable isotope compositions using an Elementar Vario Isotope Cube Elemental Analyzer (EA) that is coupled to an IsoPrime PrecisION IRMS. Powder samples were placed in tin capsules and then loaded onto a rotary autosampler. The autosampler dropped samples into the EA, and samples were combusted at 1175 °C over tungsten oxide in a continuous stream of helium carrier gas. A pulse of oxygen is added to the gas stream resulting in flash combustion of the tin capsule containing the sample, which raises the reaction temperature to approximately 1800 °C for a few seconds. The combustion reaction produces SO 2 , N 2 and CO 2 from any sulfur, nitrogen and carbon present in the sample. The resulting gases were then passed through a reduced copper reactor that was heated to 850 °C, to reduce NO x to N 2 , reduce SO 3 to SO 2 , and trap any volatile halogen compounds on silver wool. Following water removal using an adsorption tube, the N 2 , CO 2 , and SO 2 analyte gases were separated and purified using purge-trap columns. The purified gases were then carried through a thermal conductivity detector. The detector signal was passed to software that calculated elemental abundances based on integrated peak areas. The sample gases were then passed to the IRMS and stable isotope ratios were measured. Raw sample peak areas were corrected by subtracting the average peak area from blanks consisting of empty tin capsules run using the same EA analysis method. Blanks were also run following each replicate to verify that all the material was combusted. The Viognier sample was analyzed in triplicate on two days (target sample masses: 30, 60 and 90 mg). The following standards were analyzed to calibrate EA-IRMS measurements: IAEA-C6, USGS-40, USGS-41, IAEA-S1, and IAEA-S2.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Shuttle orbiter KU-band radar/communications system design evaluation

An expanded introduction is presented which addresses the in-depth nature of the tasks and indicates continuity of the reported effort and results with previous work and related contracts, and the two major modes of operation which exist in the Ku-band system, namely, the radar mode and the communication mode, are described. The Ku-band radar system is designed to search for a target in a designated or undesignated mode, then track the detected target, which might be cooperative (active) or passive, providing accurate, estimates of the target range, range rate, angle and angle rate to enable the orbiter to rendezvous with this target. The radar mode is described along with a summary of its predicted performance. The principal sub-unit that implements the radar function is the electronics assembly 2(EA-2). The relationship of EA-2 to the remainder of the Ku-band system is shown. A block diagram of EA-2 is presented including the main command and status signals between EA-2 and the other Ku-band units.

Source record↗

Beginning Research with the 1.8-meter Spacewatch Telescope

The purpose of this grant was to bring the Spacewatch 1.8-m telescope to operational status for research on asteroids and comets. This objective was achieved; first light with the telescope was in May 2000 and since then several tests and demonstrations of the facility's capability to observe Earth-approaching Asteroids (EAs) have been made, including the first observations to be incorporated into a peer-reviewed publication. The Spacewatch 1.8-m telescope will be the largest in the world dedicated full time to finding and doing astrometry of asteroids and comets. It will be used to search for asteroids and comets anywhere from the space near Earth to regions beyond the orbit of Neptune, and to do astrometry and lightcurves on the fainter of such objects that are already known. Its comparatively large aperture will permit faster discovery of the very small asteroids in Earthlike orbits, such as 1998 KY(sub 26), that are coveted for their accessibility as material resources in space, as well as recovery of EAs on their return apparitions when they tend to be more distant and fainter than they were at the times of their discoveries. It will also tend to find EAs when they do not happen to be close to Earth. Discoveries made under those circumstances allow the objects to be followed for longer intervals, providing better determinations of their orbits during their discovery apparitions. In addition to its size, the 1.8-m Spacewatch telescope will have the unique capability of long strip scanning in any direction, for example along the ecliptic (the plane of the solar system), and along the line of variation of EAs with uncertain orbits that are being targeted for recovery.

Gehrels, Tom↗

Hologic QDR 2000 whole-body scans: a comparison of three combinations of scan modes and analysis software

This study reports on the short-term in vivo precision and absolute measurements of three combinations of whole-body scan modes and analysis software using a Hologic QDR 2000 dual-energy X-ray densitometer. A group of 21 normal, healthy volunteers (11 male and 10 female) were scanned six times, receiving one pencil-beam and one array whole-body scan on three occasions approximately 1 week apart. The following combinations of scan modes and analysis software were used: pencil-beam scans analyzed with Hologic's standard whole-body software (PB scans); the same pencil-beam analyzed with Hologic's newer "enhanced" software (EPB scans); and array scans analyzed with the enhanced software (EA scans). Precision values (% coefficient of variation, %CV) were calculated for whole-body and regional bone mineral content (BMC), bone mineral density (BMD), fat mass, lean mass, %fat and total mass. In general, there was no significant difference among the three scan types with respect to short-term precision of BMD and only slight differences in the precision of BMC. Precision of BMC and BMD for all three scan types was excellent: < 1% CV for whole-body values, with most regional values in the 1%-2% range. Pencil-beam scans demonstrated significantly better soft tissue precision than did array scans. Precision errors for whole-body lean mass were: 0.9% (PB), 1.1% (EPB) and 1.9% (EA). Precision errors for whole-body fat mass were: 1.7% (PB), 2.4% (EPB) and 5.6% (EA). EPB precision errors were slightly higher than PB precision errors for lean, fat and %fat measurements of all regions except the head, although these differences were significant only for the fat and % fat of the arms and legs. In addition EPB precision values exhibited greater individual variability than PB precision values. Finally, absolute values of bone and soft tissue were compared among the three combinations of scan and analysis modes. BMC, BMD, fat mass, %fat and lean mass were significantly different between PB scans and either of the EPB or EA scans. Differences were as large as 20%-25% for certain regional fat and BMD measurements. Additional work may be needed to examine the relative accuracy of the scan mode/software combinations and to identify reasons for the differences in soft tissue precision with the array whole-body scan mode.

NASA Discipline Musculoskeletal↗

Mass Changes of the Greenland and Antarctic Ice Sheets and Shelves and Contributions to Sea-level Rise: 1992-2002

Changes in ice mass are estimated from elevation changes derived from 10.5 years (Greenland) and 9 years (Antarctica) of satellite radar altimetry data from the European Remote-sensing Satellites ERS-1 and -2. For the first time, the dH/dt values are adjusted for changes in surface elevation resulting from temperature-driven variations in the rate of fun compaction. The Greenland ice sheet is thinning at the margins (-42 plus or minus 2 Gta(sup -1) below the equilibrium line altitude (ELA)) and growing inland (+53 plus or minus 2 Gt a(sup -1)above the ELA) with a small overall mass gain (+11 plus or minus 3 Gt a(sup -1); -0.03 mm a(sup -1) SLE (sea level equivalent)). The ice sheet in West Antarctica (WA) is losing mass (-47 (dot) 4 GT a(sup -1) and the ice sheet in East Antarctica (EA) shows a small mass gain (+16 plus or minus 11 Gt a(sup -1) for a combined net change of -31 plus or minus 12 Gt a(sup -1) (+0.08 mm a(sup -1) SLE)). The contribution of the three ice sheets to sea level is +0.05 plus or minus 0.03 mm a(sup -1). The Antarctic ice shelves show corresponding mass changes of -95 (dot) 11 Gt a(sup -1) in WA and +142 plus or minus 10 Gt a(sup -1) in EA. Thinning at the margins of the Greenland ice sheet and growth at higher elevations is an expected response to increasing temperatures and precipitation in a warming climate. The marked thinnings in the Pine Island and Thwaites Glacier basins of WA and the Totten Glacier basin in EA are probably ice-dynamic responses to long-term climate change and perhaps past removal of their adjacent ice shelves. The ice growth in the southern Antarctic Peninsula and parts of EA may be due to increasing precipitation during the last century.

Zwally, H. Jay↗

[Stardust Amines]

We investigated the abundances of amino acids and amines, as well as their enantiomeric composition in water extracts of comet Wild 2 exposed aerogel and aluminum foils returned by Stardust using liquid chromatography with UV fluorescence detection and time of flight-mass spectrometry (LC-FD/ToF-MS). A suite of amino acids and amines including glycine, L-alanine, methylamine (MA), and ethylamine (EA) were identified in the Stardust bulk aerogel. With the exception of MA and EA, all other primary amines detected in comet-exposed aerogels were also present in the aerogel witness tile that was not exposed to Wild 2, suggesting that most amines are terrestrial in origin. The enhanced abundances of MA, EA, and possibly glycine in comet-exposed aerogel compared to controls, coupled with MA to EA ratios (approx.1 to 2) that are distinct from preflight aerogels (approx.7 to lo), suggest that these amines were captured from Wild 2. The presence of cometary amines in Stardust material supports the hypothesis that comets were an important source of prebiotic organics on the early Earth. To better understand their origin, a systematic study of all these species with C, N, and H compound specific isotopic analysis (CSIA) via gas chromatography quadrupole mass spectrometry in with parallel with combustion isotope ratio mass spectrometry (GC-QMS/IRMS) is being conducted. We will discuss our latest C-CSIA measurements and what they indicate about the origin of the amino acids extracted from Stardust samples.

Dworkin, Jason P.↗

Point Spread Function of ASTRO-H Soft X-Ray Telescope (SXT)

ASTRO-H (Hitomi) satellite equips two Soft X-ray Telescopes (SXTs), one of which (SXT-S) is coupled to Soft-X-ray Spectrometer (SXS) while the other (SXT-I) is coupled to Soft X-ray Imager (SXI). Although SXTs are lightweight of approximately 42 kgmodule1 and have large on-axis effective area (EA) of approximately 450 cm(exp 2) at 4.5 keV module(sub 1) by themselves, their angular resolutions are moderate approximately 1.2 arcmin in half power diameter. The amount of contamination into the SXS FOV (3.05 times 3.05 arcmin(exp 2) from nearby sources was measured in the ground-based calibration at the beamline in Institute of Space and Astronautical Science. The contamination at 4.5 keV were measured with sources distant from the SXS center by one width of the FOV in perpendicular and diagonal directions, that is, 3 and 4.5 arcmin-off, respectively. The average EA of the contamination in the four directions with the 3 and 4.5 arcmin-off were measured to be 2 and 0.6% of the on-axis EA of 412 cm (exp) for the SXS FOV, respectively. The contamination from a source distant by two FOV widths in a diagonal direction, that is, 8.6 arcmin-off was measured to be 0.1% of the on-axis at 4.5 keV. The contamination amounts were also measured at 1.5 keV and 8.0 keV which indicated that the ratio of the contamination EA to that of on-axis hardly depended on the source energy. The off-axis SXT-I images from 4.5 to 27 arcmin were acquired at intervals of -4.5 arcmin for the SXI FOV of 38 times 38 arcmin(exp 2). The image shrinked as the off-axis angle increased. Above 13.5 arcmin of off-angle, a stray appeared around the image center in the off-axis direction. As for the on-axis image, a ring-shaped stray appeared at the edge of SXI of approximately 18 arcmin distant from the image center.

Soft X-ray spectrometer↗

Modeling of the Tau and Muon Neutrino-induced Optical Cherenkov Signals from Upward-moving Extensive Air Showers

We present a detailed modeling and computation methodology to determine the optical Cherenkovsignals produced by upward-moving extensive air showers (EASs) induced byτ-leptons and muons,sourced from the interaction of high-energy astrophysical neutrinos interacting in the Earth. Fol-lowing and extending the physics modeling and Cherenkov signal simulations performed in [1], thisscheme encompasses a new, state-of-the-art computation of the muon neutrino propagation insidethe Earth and the contribution to theτ-lepton muon decay channel. The modeling takes into ac-count all possibleτ-lepton decay and muon energy loss channels that feed the optical Cherenkovemission, produced by both tau and muon initiated EASs. The EAS modeling uses the electronenergy, angular, and lateral distributions in the EAS and their evolution as well as the wavelengthdependence of the Cherenkov emission and its atmospheric attenuation. The results presented hereare focused on the detection capabilities of sub-orbital (balloon-borne) and orbital (satellite) basedinstruments. The latter case was calculated for POEMMAato compare to that presented in [1],specifically including the muon-decay channel ofτ-leptons and the muonic EAS Cherenkov signalfrom muon neutrino interactions in the Earth. By detailing all these individual contributions tothe optical Cherenkov emission and detection, we show how the ensemble that includes muonicchannels provides a large detection capability for space-based, high-energy cosmic neutrino detec-tion. Specifically, we show that for neutrino energies∼<10 PeV, the upward-EAS sensitivity due tomuon neutrino interactions in the Earth begin to dominate over that for tau neutrino interactions,effectively extending the neutrino sensitivity to lower energies.

A L Cummings↗

Mass Balance of the Antarctic Ice Sheet 1992–2016: Reconciling Results from GRACE Gravimetry With ICESat, ERS1/2 and Envisat Altimetry

GRACE and ICESat Antarctic mass-balance differences are resolved utilizing their dependencies on corrections for changes in mass and volume of the same underlying mantle material forced by ice-loading changes. Modeled gravimetry corrections are 5.22 times altimetry corrections over East Antarctica (EA) and 4.51 times over West Antarctica (WA), with inferred mantle densities 4.75 and 4.11 g/cu. cm. Derived sensitivities (Sg, Sa) to bedrock motion enable calculation of motion (δB0) needed to equalize GRACE and ICESat mass changes during 2003–08. For EA, δB0 is −2.2 mm/a subsidence with mass matching at 150 Gt/a, inland WA is −3.5 mm/a at 66 Gt/a, and coastal WA is only −0.35 mm/a at −95 Gt/a. WA subsidence is attributed to low mantle viscosity with faster responses to post-LGM deglaciation and to ice growth during Holocene grounding-line readvance. EA subsidence is attributed to Holocene dynamic thickening. With Antarctic Peninsula loss of −26 Gt/a, the Antarctic total gain is 95 ± 25 Gt/a during 2003–08, compared to 144 ± 61 Gt/a from ERS1/2 during 1992–2001. Beginning in 2009, large increases in coastal WA dynamic losses overcame long-term EA and inland WA gains bringing Antarctica close to balance at −12 ± 64 Gt/a by 2012–16.

Antarctic glaciology↗

Medical Lessons Learned from the Exploration Atmospheres Study

Background: The National Aeronautics and Space Administration’s (NASA) Exploration Atmospheres study (EA) was done to evaluate alternative cabin atmospheres for future spacecraft designs and planetary surface exploration of the Moon, Mars and beyond. Deep space exploration involves creating habitats and environments safe for human occupancy and means to explore the outside environment (extravehicular activities, EVA). In order to validate alternative atmospheres and pre-spacewalk procedures, the EA study was conducted to evaluate factors such as hypoxia risks, denitrogenation protocols, food limitations, medications, and the impact of other factors on human performance. Overview: Space travel is constrained by mass, volume, power and the cost of vehicle development, which creates tradeoffs in various capabilities, including breathing gasses. Higher atmospheric pressure in a vehicle means more gas, and a stronger containment vessel/habitat; while lower pressure requires higher oxygen partial pressure, which may increase fire risk. NASA’s EA study evaluated a proposed alternative cabin environment (8.2 psia, 34% Oxygen), for future spacecraft habitat, and planetary EVAs. EA included both a 3-day and a 11-day trial. These trials included a depressurization and saturation to 8.2psi at 34% O2 with additional depresses to 4.3 psia at 85% O2 for simulated EVAs, (1 EVA during the 3-day and 5 during the 11-day trials). Discussion: Planning for and executing the medical monitoring and response plan for a trial of this scope was a huge undertaking with no prior practice to fall back on. Food obstacles, sleeping issues, medications, joint injury, equipment limitations, medical privacy, multiple cases of decompression sickness, and even a COVID outbreak among the support team proved challenging. Conclusion: Testing of this nature is an essential part NASA’s preparation for the upcoming Lunar Artemis missions. As spaceflight transitions beyond low earth orbit, to planetary, even more trials of this nature will be required to learn what are the optimal atmospheric and associated operational constraints to maintain the optimal health of the crew and achieve mission objectives.

R Sanders↗

Momentum Spectrum of Cosmic Muons at a Depth of 320 Mwe

Since their discovery, great progress has been achieved in the field of cosmic ray physics particularly towards the understanding of the origin, transport and acceleration mechanisms of the high energy particles that constitute primary cosmic rays, their interaction processes in the galactic and extra galactic media, and also in the Earth's atmosphere. The interaction of primary cosmic ray particles in the Earth's atmosphere leads to the production of a cascade of secondary particles or Extensive Air Showers (EAS) with various components - electromagnetic, hadronic, muon and neutrino components. There is a large number of models to describe these interactions. Many cosmic ray experiments have used a variety of observables in EAS that provide an understanding of the hadronic interactions and also shed some light on the chemical composition of the primary particles. The muon flux at the surface provides a useful tool for the calculations of neutrino fluxes, the reconstruction of EAS and it can serve as a test of various interaction models. The CosmoALEPH detector, whichwas one of the experiments in CosmoLEP used the ALEPH detector at the European Laboratory for Particle Physics, CERN, to measure the muonic component of EAS. Preliminary results have recently shown that the momentum spectrum and charge ratio for cosmic muons measured by CosmoALEPH are well within the world average. This work reports on further improvements in the reconstruction of the cosmic muon events and data analysis. Cosmic muons are produced through interactions of primary cosmic radiation in the atmosphere. They are a component of extensive air showers which can also be measured underground. The CosmoALEPH experiment used the ALEPH detector at the European Laboratory for Particle Physics, CERN, to measure cosmic muon events at a depth of 320 mwe underground. The momentum spectrum and charge ratio of the cosmic muons are measured. The results are compared with the expectations from MC simulations based on different hadronic interaction models.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Air shower detectors in gamma-ray astronomy

Extensive air shower (EAS) arrays directly detect the particles in an EAS that reach the observation altitude. This detection technique effectively makes air shower arrays synoptic telescopes -- they are capable of simultaneously and continuously viewing the entire overhead sky. Typical air shower detectors have an effective field-of-view of 2 sr and operate nearly 100% of the time. These two characteristics make them ideal instruments for studying the highest energy gamma rays, extended sources and transient phenomena. Until recently air shower arrays have had insufficient sensitivity to detect gamma-ray sources. Over the past decade, the situation has changed markedly. Milagro, in the US, and the Tibet AS{gamma} array in Tibet, have detected very-high-energy gamma-ray emission from the Crab Nebula and the active galaxy Markarian 421 (both previously known sources). Milagro has discovered TeV diffuse emission from the Milky Way, three unidentified sources of TeV gamma rays, and several candidate sources of TeV gamma rays. Given these successes and the suite of existing and planned instruments in the GeV and TeV regime (AGILE, GLAST, HESS, VERITAS, CTA, AGIS and IceCube) there are strong reasons for pursuing a next generation of EAS detectors. In conjunction with these other instruments the next generation of EAS instruments could answer long-standing problems in astrophysics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Probing transport energies and defect states in organic semiconductors using energy resolved electrochemical impedance spectroscopy

Abstract Determining the relative energies of transport states in organic semiconductors is critical to understanding the properties of electronic devices and in designing device stacks. Futhermore, defect states are also highly important and can greatly impact material properties and device performance. Recently, energy‐resolved electrochemical impedance spectroscopy (ER‐EIS) is developed to probe both the ionization energy (IE) and electron affinity (EA) as well as sub‐bandgap defect states in organic semiconductors. Herein, ER‐EIS is compared to cyclic voltammetry (CV) and photoemission spectroscopies for extracting IE and EA values, and to photothermal deflection spectroscopy (PDS) for probing defect states in both polymer and molecular organic semiconductors. The results show that ER‐EIS determined IE and EA are in better agreement with photoemission spectroscopy measurements as compared to CV for both polymer and molecular materials. Furthermore, the defect states detected by ER‐EIS agree with sub‐bandgap features detected by PDS. Surprisingly, ER‐EIS measurements of regiorandom and regioregular poly(3‐hexylthiophene) (P3HT) show clear defect bands that occur at significantly different energies. In regioregular P3HT the defect band is near the edge of the occupied states while it is near the edge of the unoccupied states in regiorandom P3HT.

14 SOLAR ENERGY↗

Fullerene "Superhalogen" Radicals: The Substituent Effect on Electronic Properties of 1,7,11,24,27-C60X5

Hexasubstituted fullerenes with the skew pentagonal pyramid (SPP) addition pattern are predominantly formed in many types of reactions and represent important and versatile building blocks for supramolecular chemistry, biomedical and optoelectronic applications. Regioselective synthesis and characterization of the new SPP derivative, C60(CF3)4(CN)H, in this work led us to the experimental identification of the new family of "superhalogen fullerene radicals", species with the gas-phase electron affinity higher than that of the most electronegative halogens, F and Cl. Low-temperature photoelectron spectroscopy and DFT studies of different C60X5 radicals reveal a profound effect of X groups on their electron affinities (EA), which vary from 2.76 eV (X = CH3) to 4.47 eV (X= CN). The measured gas-phase EA of the newly synthesized C60(CF3)4CN equals 4.28 (1) eV, which is ca. 1 eV higher than the EA of Cl atom. An observed remarkable stability of C60(CF3)4CN– in solution under ambient conditions opens new venues for design of air-stable molecular complexes and salts for supramolecular structures of electroactive functional materials.

electron affinity↗

PAH/PAH(CF 3 ) n Donor/Acceptor Charge‐Transfer Complexes in Solution and in Solid‐State Co‐Crystals

Abstract A solution, solid‐state, and computational study is reported of polycyclic aromatic hydrocarbon PAH/PAH(CF 3 ) n donor/acceptor (D/A) charge‐transfer complexes that involve six PAH(CF 3 ) n acceptors with known gas‐phase electron affinities that range from 2.11(2) to 2.805(15) eV and four PAH donors, including seven CT co‐crystal X‐ray structures that exhibit hexagonal arrays of mixed π‐stacks with 1/1, 1/2, or 2/1 D/A stoichiometries (PAH=anthracene, azulene, coronene, perylene, pyrene, triphenylene; n= 5, 6). These are the first D/A CT complexes with PAH(CF 3 ) n acceptors to be studied in detail. The nine D/A combinations were chosen to allow several structural and electronic comparisons to be made, providing new insights about controlling D/A interactions and the structures of CT co‐crystals. The comparisons include, among others, CT complexes of the same PAH(CF 3 ) n acceptor with four PAH donors and CT complexes of the same donor with four PAH(CF 3 ) n acceptors. All nine CT complexes exhibit charge‐transfer bands in solution with λ max between 467 and 600 nm. A plot of E ( λ max ) versus [ IE (donor)− EA (acceptor)] for the nine CT complexes studied is linear with a slope of 0.72±0.03 eV eV −1 . This plot is the first of its kind for CT complexes with structurally related donors and acceptors for which precise experimental gas‐phase IE s and EA s are known. It demonstrates that conclusions based on the common assumption that the slope of a CT E ( λ max ) versus [ IE − EA ] plot is unity may be incorrect in at least some cases and should be reconsidered.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗