Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Dose Estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Ecdysteroids affect in vivo protein metabolism of the flight muscle of the tobacco hornworm (Manduca sexta)

Ecdysteroid growth promotion of the dorsolongitudinal flight muscle of Manduca sexta was studied by measuring in vivo protein metabolism using both "flooding-dose" and "non-carrier" techniques. These procedures differ in that the former method includes injection of non-labelled phenylalanine (30 micromoles/insect) together with the [3H]amino acid. Injected radioactivity plateaued in the haemolymph within 7 min. With the flooding-dose method, haemolymph and intramuscular specific radioactivities were similar between 15 min and 2 h. Incorporation of [3H]phenylalanine into muscle protein was linear with either method between 30 and 120 min. Fractional rates (%/12 h) of synthesis with the flooding-dose technique were best measured after 1 h because of the initial delay in radioactivity equilibration. Estimation of body phenylalanine turnover with the non-carrier method showed 24-53%/h which was negligible with the flooding-dose method. Since the two methods yielded similar rates of protein synthesis, the large injection of non-labelled amino acid did not alter the rate of synthesis. Because the flooding-dose technique requires only a single time point measurement, it is the preferred method. The decline and eventual cessation of flight-muscle growth was mostly a consequence of declining protein synthesis though degradation increased between 76-86 h before eclosion and was relatively rapid. This decline in muscle growth could be prevented by treating pupae with 20-hydroxyecdysone (10 micrograms/insect). Protein accretion was promoted by a decline of up to 80% in protein breakdown, which was offset in part by a concurrent though much smaller decrease in protein synthesis. Therefore, ecdysteroids may increase flight-muscle growth by inhibiting proteolysis.

NASA Discipline Developmental Biology↗

Radiation dosimetry measurements during U.S. Space Shuttle missions with the RME-III

Time-resolved radiation dosimetry measurements inside the crew compartment have been made during recent Shuttle missions with the U.S. Air Force Radiation Monitoring Equipment-III (RME-III), a portable battery-powered four-channel tissue equivalent proportional counter. Results from the first six missions are presented and discussed. Half of the missions had orbital inclinations of 28.5 degrees with the remainder at inclinations of 57 degrees or greater; altitudes ranged from 300 to 600 km. The determined dose equivalent rates ranged from 70 to 5300 microSv/day. The RME-III measurements are in good agreement with other dosimetry measurements made aboard the vehicles. Measurements indicate that medium- and high-LET particles contribute less than 2% of the particle fluence for all missions, but up to 50% of the dose equivalent, depending on the spacecraft's altitude and orbital inclination. Isocontours of fluence, dose and dose equivalent rate have been developed from measurements made during the STS-28 mission. The drift rate of the South Atlantic Anomaly is estimated to be 0.49 degrees W/yr and 0.12 degrees N/yr. The calculated trapped proton and GCR dose for the STS-28 mission was significantly lower than the measured values.

STS-28 Shuttle Project↗

Analytical Calculation of the Energy Deposition Spectrum and Average Dose to A Spherical Target By Ion Tracks at All Impact Parameters

Microdosimetry is used to estimate quality factors for risk assessment in radiation protection [1] and to quantify relative biological effectiveness (RBE) for treatment planning of hadron radiation therapy [2]. Radiation physics has shown that energetic ions deposit energy in a complex manner: the track structure. The Local Effect Model (LEM) [3] is often used as an approximation to describe this complex track structure. We have previously calculated an analytical expression for the dose to a spherical target fully located in the penumbra of an ion track using the LEM [4]. In this work, the calculation has been extended to all impact parameters. Furthermore, using these analytical expressions, it was possible to obtain the theoretical energy deposition spectra to a sphere irradiated uniformly.

I Plante↗

Persistence of Space Radiation-Induced Cytogenetic Damage in the Blood Lymphocytes of Astronauts and the Effects of Repeat Long Duration Space Missions

The yield of chromosome damage in astronauts blood lymphocytes has been shown to increase after long duration space missions of a few months or more. This provides a useful in vivo measurement of space radiation induced damage that takes into account individual radiosensitivity and considers the influence of microgravity and other stress conditions. We present our latest follow-up analyses of chromosome damage in astronauts blood lymphocytes assessed by fluorescence in situ hybridization (FISH) chromosome painting and collected at various times, from directly after return from space to several years after flight. For most individuals the analysis of individual time-courses for translocations revealed a temporal decline of yields with different half-lives. Dose was derived from frequencies of chromosome exchanges using preflight calibration curves, and estimates derived from samples collected a few days after return to earth lie within the range expected from physical dosimetry. However, a temporal decline in yields may indicate complications with the use of stable aberrations for retrospective dose reconstruction, and the differences in the decay time may reflect individual variability in risk from space radiation exposure. Limited data on three individuals who have participated in repeat long duration space flights indicates a lack of correlation between time in space and translocation yields, and show a possible adaptive response to space radiation exposure.

George, Kerry A.↗

In-flight radiation measurements on STS-60

A joint investigation between the United States and Russia to study the radiation environment inside the Space Shuttle flight STS-60 was carried out as part of the Shuttle-Mir Science Program (Phase 1). This is the first direct comparison of a number of different dosimetric measurement techniques between the two countries. STS-60 was launched on 3 February 1994 in a nearly circular 57 degrees x 353 km orbit with five U.S. astronauts and one Russian cosmonaut for 8.3 days. A variety of instruments provided crew radiation exposure, absorbed doses at fixed locations, neutron fluence and dose equivalent, linear energy transfer (LET) spectra of trapped and galactic cosmic radiation, and energy spectra and angular distribution of trapped protons. In general, there is good agreement between the U.S. and Russian measurements. The AP8 Min trapped proton model predicts an average of 1.8 times the measured absorbed dose. The average quality factor determined from measured lineal energy, y, spectra using a tissue equivalent proportional counter (TEPC), is in good agreement with that derived from the high temperature peak in the 6LiF thermoluminescent detectors (TLDs). The radiation exposure in the mid-deck locker from neutrons below 1 MeV was 2.53 +/- 1.33 microSv/day. The absorbed dose rates measured using a tissue equivalent proportional counter, were 171.1 +/- 0.4 and 127.4 +/- 0.4 microGy/day for trapped particles and galactic cosmic rays, respectively. The combined dose rate of 298.5 +/- 0.82 microGy/day is about a factor of 1.4 higher than that measured using TLDs. The westward longitude drift of the South Atlantic Anomaly (SAA) is estimated to be 0.22 +/- 0.02 degrees/y. We evaluated the effects of spacecraft attitudes on TEPC dose rates due to the highly anisotropic low-earth orbit proton environment. Changes in spacecraft attitude resulted in dose-rate variations by factors of up to 2 at the location of the TEPC.

NASA Discipline Radiation Health↗

Galactic cosmic ray radiation levels in spacecraft on interplanetary missions

Using the Langley Research Center Galactic Cosmic Ray (GCR) transport computer code (HZETRN) and the Computerized Anatomical Man (CAM) model, crew radiation levels inside manned spacecraft on interplanetary missions are estimated. These radiation-level estimates include particle fluxes, LET (Linear Energy Transfer) spectra, absorbed dose, and dose equivalent within various organs of interest in GCR protection studies. Changes in these radiation levels resulting from the use of various different types of shield materials are presented.

Shinn, J. L.↗

Neutron influences and energy spectra in the Cosmos-2044 biosatellite orbit

Joint Soviet-American measurements of the neutron component of space radiation (SR) were carried out during the flight of the Soviet biosatellite Cosmos-2044. Neutron flux densities and differential energy spectra were measured inside and on the external surface of the spacecraft. Three energy intervals were employed: thermal (E(sub n) less than or equal to 0.2 eV), resonance (0.2 eV less than E(sub n) less than 1.0 MeV) and fast (E(sub n) greater than or equal to 1.0 MeV) neutrons. The first two groups were measured with U.S. (6)LiF detectors, while fast neutrons were recorded both by U.S. fission foils and Soviet nuclear emulsions. Estimations were made of the contributions to absorbed and equivalent doses from each neutron energy interval and a correlation was presented between fast neutron fluxes, measured outside the satellite, and the phase of solar activity (SA). Average dose equivalent rates of 0.018 and 0.14 mrem d(exp -1) were measured for thermal and resonance neutrons, respectively, outside the spacecraft. The corresponding values for fast neutrons were 3.3 (U.S.) and 1.8 (U.S.S.R.) mrem d(exp -1). Inside the spacecraft, a value of 3.5 mrem d(exp -1) was found.

Dudkin, V. E.↗

Study of Resource Recovery and Epidemiology in an Anaerobic Digester

Three 4-liter packed bed anaerobic digesters were fabricated and operated at 35 degrees C, pH around 7, and hydraulic retention time (HRT) of 20, 10 and 5 days to study the resource recovery and epidemiology in a controlled ecological life support system (CELSS). A simulated wastewater, consisted of shower water, clothwash water, dishwasher water, handwash water, and urine flush water was used as the feeding solution. Under steady-state operation, chemical oxygen demand (COD), total organic carbon (TOC), pH, nitrogen, phosphorus, and potassium wer monitored in the digester input and output solutions. The volume and the CH4/CO2 ratios in the biogas produced from the anaerobic digesters were measured. The results indicate about 90 percent of TOC is converted while only 5-8 percent of N-P-K are consumed in the digester. A multi-drug resistant strain of Salmonella choleraesuis was used as the indicator bacterium in the epidemiology study. The levels of Salmonella choleraesuis in the influent and the effluent wer determined and decimal decay rate constants, k(d), were estimated. The k(d) values were greater at higher initial doses than lower doses for the same HR, and greater for batch digestion (7.89/d) than for continuous digestion (4.28, 3.82, and 3.82/d for 20, 10, and 5 d HRT, respectively).

Li, K. Y.↗

Neutron fluences and energy spectra in the Cosmos-2044 biosatellite orbit

Joint Soviet-American measurements of the neutron component of space radiation (SR) were carried out during the flight of the Soviet biosatellite Cosmos-2044. Neutron flux densities and differential energy spectra were measured inside and on the external surface of the spacecraft. Three energy intervals were employed: thermal (En < or = 0.2 eV), resonance (0.2 eV < En < 1.0 MeV) and fast (En > or = 1.0 MeV) neutrons. The first two groups were measured with U.S. 6LiF detectors, while fast neutrons were recorded both by U.S. fission foils and Soviet nuclear emulsions. Estimations were made of the contributions to absorbed and equivalent doses from each neutron energy interval and a correlation was presented between fast neutron fluxes, measured outside the satellite, and the phase of solar activity (SA). Average dose equivalent rates of 0.018 and 0.14 mrem d-1 were measured for thermal and resonance neutrons, respectively, outside the spacecraft. The corresponding values for fast neutrons were 3.3 (U.S.) and 1.8 (U.S.S.R.) mrem d-1. Inside the spacecraft, a value of 3.5 mrem d-1 was found.

NASA Discipline Number 00-00↗

A Photo-Realistic 3-D Mapping System for Extreme Nuclear Environments: Chornobyl

We present a novel stereoscopic mapping system for use in nuclear accident settings. First we discuss a radiation shielded sensor array desigtned to tolerate 10(sup 6)R of cumulative dose. Next we give procedures to ensure timely, accurate range estimation using trinocular stereo. Finally, we review the implementation of a system for the integration of range information into a 3-D, textured, metrically accurate surface mesh.

3-D mapping Chornobyl robot Pioneer robot Pioneer ↗

Evidence Report: Risk of Cardiovascular Disease and Other Degenerative Tissue Effects from Radiation Exposure

Occupational radiation exposure from the space environment may result in non-cancer or non-CNS degenerative tissue diseases, such as cardiovascular disease, cataracts, and respiratory or digestive diseases. However, the magnitude of influence and mechanisms of action of radiation leading to these diseases are not well characterized. Radiation and synergistic effects of radiation cause DNA damage, persistent oxidative stress, chronic inflammation, and accelerated tissue aging and degeneration, which may lead to acute or chronic disease of susceptible organ tissues. In particular, cardiovascular pathologies such as atherosclerosis are of major concern following gamma-ray exposure. This provides evidence for possible degenerative tissue effects following exposures to ionizing radiation in the form of the GCR or SPEs expected during long-duration spaceflight. However, the existence of low dose thresholds and dose-rate and radiation quality effects, as well as mechanisms and major risk pathways, are not well-characterized. Degenerative disease risks are difficult to assess because multiple factors, including radiation, are believed to play a role in the etiology of the diseases. As additional evidence is pointing to lower, space-relevant thresholds for these degenerative effects, particularly for cardiovascular disease, additional research with cell and animal studies is required to quantify the magnitude of this risk, understand mechanisms, and determine if additional protection strategies are required.The NASA PEL (Permissive Exposure Limit)s for cataract and cardiovascular risks are based on existing human epidemiology data. Although animal and clinical astronaut data show a significant increase in cataracts following exposure and a reassessment of atomic bomb (A-bomb) data suggests an increase in cardiovascular disease from radiation exposure, additional research is required to fully understand and quantify these adverse outcomes at lower doses (less than 0.5 gray (SI unit for ionizing radiation dosage, i.e. one joule of radiation energy per one kilogram of matter)) to facilitate risk prediction. This risk has considerable uncertainty associated with it, and no acceptable model for projecting degenerative tissue risk is currently available. In particular, risk factors such as obesity, alcohol, and tobacco use can act as confounding factors that contribute to the large uncertainties. The PELs could be violated under certain scenarios, including following a large SPE (solar proton event) or long-term GCR (galactic cosmic ray) exposure. Specifically, for a Mars mission, the accumulated dose is sufficiently high that epidemiology data and preliminary risk estimates suggest a significant risk for cardiovascular disease. Ongoing research in this area is intended to provide the evidence base for accurate risk quantification to determine criticality for extended duration missions. Data specific to the space radiation environment must be compiled to quantify the magnitude of this risk to decrease the uncertainty in current PELs and to determine if additional protection strategies are required. New research results could lead to estimates of cumulative radiation risk from CNS and degenerative tissue diseases that, when combined with the cancer risk, may have major negative impacts on mission design, costs, schedule, and crew selection. The current report amends an earlier report (Human Research Program Requirements Document, HRP-47052, Rev. C, dated Jan 2009) in order to provide an update of evidence since 2009.

Patel, Zarana↗

BioSentinel: Mission Development of a Radiation Biosensor to Gauge DNA Damage and Repair Beyond Low Earth Orbit on a 6U Nanosatellite.

We are designing and developing a "6U" (10 x 22 x 34 cm; 14 kg) nanosatellite as a secondary payload to fly aboard NASA's Space Launch System (SLS) Exploration Mission (EM) 1, scheduled for launch in late 2017. For the first time in over forty years, direct experimental data from biological studies beyond low Earth orbit (LEO) will be obtained during BioSentinel's 12- to 18- month mission. BioSentinel will measure the damage and repair of DNA in a biological organism and allow us to compare that to information from onboard physical radiation sensors. In order to understand the relative contributions of the space environment's two dominant biological perturbations, reduced gravity and ionizing radiation, results from deep space will be directly compared to data obtained in LEO (on ISS) and on Earth. These data points will be available for validation of existing biological radiation damage and repair models, and for extrapolation to humans, to assist in mitigating risks during future long-term exploration missions beyond LEO. The BioSentinel Payload occupies 4U of the spacecraft and will utilize the monocellular eukaryotic organism Saccharomyces cerevisiae (yeast) to report DNA double-strand-break (DSB) events that result from ambient space radiation. DSB repair exhibits striking conservation of repair proteins from yeast to humans. Yeast was selected because of 1) its similarity to cells in higher organisms, 2) the well-established history of strains engineered to measure DSB repair, 3) its spaceflight heritage, and 4) the wealth of available ground and flight reference data. The S. cerevisiae flight strain will include engineered genetic defects to prevent growth and division until a radiation-induced DSB activates the yeast's DNA repair mechanisms. The triggered culture growth and metabolic activity directly indicate a DSB and its successful repair. The yeast will be carried in the dry state within the 1-atm P/L container in 18 separate fluidics cards with each card having 16 independent culture microwells, with integral microchannels and filters to supply nutrients and reagents, confine the yeast to the wells, and enable optical measurement. The measurement subsystem will monitor each subgroup of culture wells continuously for several weeks, optically tracking DSBtriggered cell growth and metabolism. BioSentinel will also include physical radiation sensors based on the TimePix sensor, as implemented by JSC's RadWorks group, which record individual radiation events including estimates of their linear-energytransfer (LET) values. Radiation-dose and LET data will be compared directly to the rate of DSB-and-repair events measured by the S. cerevisiae biosentinels. The spacecraft bus will operate in a deep space environment with functions that include command and data handling, communications, power generation (via deployable solar panels) and storage, and attitude determination-and-control system with micropropulsion. Development of the BioSentinel spacecraft will mature and prove multiple nanosatellite advances in order to function well beyond LEO: Communications from distances of ≥ 500,000 km; Autonomous attitude control, momentum management, and safe mode of nanosatellites in deep space; Shielding-, hardening-, design-, and software-derived radiation tolerance for electronics; Reliable functionality for 12 - 18 months of key subsystems for biofluidics, memory, communications, power, etc.; Close integration of living biological radiation event monitors with miniature physical radiation spectrometers; Biological measurement of solar particle events beyond Earth orbit In addition to providing the first biological results from beyond LEO in over 4 decades, BioSentinel will provide an adaptable small-satellite instrument platform to perform a range of human-exploration-relevant measurements that characterize the biological consequences of multiple outer space environments. BioSentinel is being developed under NASA's Advanced Exploration Systems program.

DNA damage↗

Space Radiation Cancer Risk Projections and Uncertainties - 2010

Uncertainties in estimating health risks from galactic cosmic rays greatly limit space mission lengths and potential risk mitigation evaluations. NASA limits astronaut exposures to a 3% risk of exposure-induced death and protects against uncertainties using an assessment of 95% confidence intervals in the projection model. Revisions to this model for lifetime cancer risks from space radiation and new estimates of model uncertainties are described here. We review models of space environments and transport code predictions of organ exposures, and characterize uncertainties in these descriptions. We summarize recent analysis of low linear energy transfer radio-epidemiology data, including revision to Japanese A-bomb survivor dosimetry, longer follow-up of exposed cohorts, and reassessments of dose and dose-rate reduction effectiveness factors. We compare these projections and uncertainties with earlier estimates. Current understanding of radiation quality effects and recent data on factors of relative biological effectiveness and particle track structure are reviewed. Recent radiobiology experiment results provide new information on solid cancer and leukemia risks from heavy ions. We also consider deviations from the paradigm of linearity at low doses of heavy ions motivated by non-targeted effects models. New findings and knowledge are used to revise the NASA risk projection model for space radiation cancer risks.

Cucinotta, Francis A.↗

Results of time-resolved radiation exposure measurements made during U.S. shuttle missions with a tissue equivalent proportional counter

Time resolved exposure measurements inside the crew compartment have been made during recent shuttle missions with the USAF Radiation Monitoring Equipment-III (RME-III), a portable four-channel tissue equivalent proportional counter. Results from the first six missions are presented and discussed. The missions had orbital inclinations ranging from 28 degrees to 57 degrees, and altitudes from 200-600km. Dose equivalent rates ranged from 40-5300 micro Sv/dy. The RME-III measurements are in good agreement with other dosimetry measurements made aboard the vehicle. Measurements indicate that medium- and high- Linear Energy Transfer (LET) particles contribute less than 2% of the particle fluence for all missions, but up to 50% of the dose equivalent, depending on the spacecraft's altitude and orbital inclination. Isa-dose rate contours have been developed from measurements made during the ST-28 mission. The drift rate of the South Atlantic Anomaly (SAA) is estimated to be 0.49 degrees W/yr and 0.12 degrees N/yr. The calculated trapped proton and Galactic Cosmic Radiation (GCR) dose for the STS-28 mission were significantly lower than the measured values.

Golightly, M. J.↗

Monte Carlo Analysis of Pion Contribution to Absorbed Dose from Galactic Cosmic Rays

Accurate knowledge of the physics of interaction, particle production and transport is necessary to estimate the radiation damage to equipment used on spacecraft and the biological effects of space radiation. For long duration astronaut missions, both on the International Space Station and the planned manned missions to Moon and Mars, the shielding strategy must include a comprehensive knowledge of the secondary radiation environment. The distribution of absorbed dose and dose equivalent is a function of the type, energy and population of these secondary products. Galactic cosmic rays (GCR) comprised of protons and heavier nuclei have energies from a few MeV per nucleon to the ZeV region, with the spectra reaching flux maxima in the hundreds of MeV range. Therefore, the MeV - GeV region is most important for space radiation. Coincidentally, the pion production energy threshold is about 280 MeV. The question naturally arises as to how important these particles are with respect to space radiation problems. The space radiation transport code, HZETRN (High charge (Z) and Energy TRaNsport), currently used by NASA, performs neutron, proton and heavy ion transport explicitly, but it does not take into account the production and transport of mesons, photons and leptons. In this paper, we present results from the Monte Carlo code MCNPX (Monte Carlo N-Particle eXtended), showing the effect of leptons and mesons when they are produced and transported in a GCR environment.

Aghara, S.K.↗

Bioavailability and Pharmacodynamics of Promethazine in Human Subjects

The acute effects of exposure to microgravity include the development of space motion sickness, which usually requires therapeutic intervention. The current drug of choice, promethazine (PMZ), is available to astronauts in three different dosage forms during space flight; its side effects include nausea, dizziness, sedation and impaired psychomotor performance. This ground-based study is designed to validate flight-suitable methods for pharmacodynamic evaluation of PMZ and to estimate bioavailability and pharmacodynamics of PMZ. Experimental design consists of intramuscular administration of three doses of PMZ (12.5,25 and 50 mg) and placebo in a randomized double blind fashion to human subjects and collecting blood, urine and saliva samples for 72 h. Subjects also complete cognitive performance test batteries, WinSCAT (Windows based Space Cognitive Assessment Test) and ARES (ANAM Readiness Evaluation System). Preliminary results indicate a significant relationship (p=9.88e-05) between circulating PMZ levels and cognitive performance parameters. Time to accurately complete memory tasks increases significantly with concentrations; higher concentrations also increase response time and decrease accuracy of substitution and matching tasks. AUC and half-life estimates for PMZ ranged between 0.12 and 1.7 mg.h/L and 15 and 50 h, respectively. These preliminary results indicate that PMZ may exhibit dose-dependent pharmacokinetics in humans; also, WinSCAT and ARES are sensitive for pharmacodynamic assessment of PMZ, and may be applicable for assessing the pharmacodynamics of other neurocognitive drugs.

Boyd, J. L.↗

Regulation of cyclic nucleotide-gated channels and membrane excitability in olfactory receptor cells by carbon monoxide

1. The effect of the putative neural messenger carbon monoxide (CO) and the role of the cGMP second-messenger system for olfactory signal generation was examined in isolated olfactory receptor neurons (ORNs) of the tiger salamander. 2. With the use of whole cell voltage-clamp recordings in combination with a series of ionic and pharmological tests, it is demonstrated that exogenously applied CO is a potent activator (K1/2 = 2.9 microM) of cyclic nucleotide-gated (CNG) channels previously described to mediate odor transduction. 3. Several lines of evidence suggest that CO mediates its effect through stimulation of a soluble guanylyl cyclase (sGC) leading to formation of the second-messenger cGMP. This conclusion is based on the findings that CO responses show an absolute requirement for guanosine 5'-triphosphate (GTP) in the internal solution, that no direct effect of CO on CNG currents in the absence of GTP is detectable, and that a blocker of sGC activation, LY85383 (10 microM), completely inhibits the CO response. 4. The dose-response curve for cGMP at CNG channels is used as a calibration to provide a quantitative estimate of the CO-stimulated cGMP formation. This analysis implies that CO is a potent activator of olfactory sGC. 5. Perforated patch recordings using amphotericin B demonstrate that low micromolar doses of CO effectively depolarize the membrane potential of ORNs through tonic activation of CNG channels. This effect in turn regulates excitable and adaptive properties of ORNs and modulates neuronal responsiveness. 6. These data argue for an important role of the cGMP pathway in olfactory signaling and support the idea that CO may function as a diffusible messenger in the olfactory system.

NASA Discipline Neuroscience↗

Differential neutron energy spectra measured on spacecraft low Earth orbit

Two methods for measuring neutrons in the range from thermal energies to dozens of MeV were used. In the first method, alpha-particles emitted from the (sup 6) Li(n.x)T reaction are detected with the help of plastic nuclear track detectors, yielding results on thermal and resonance neutrons. Also, fission foils are used to detect fast neutrons. In the second method, fast neutrons are recorded by nuclear photographic emulsions (NPE). The results of measurements on board various satellites are presented. The neutron flux density does not appear to correlate clearly with orbital parameters. Up to 50% of neutrons are due to albedo neutrons from the atmosphere while the fluxes inside the satellites are 15-20% higher than those on the outside. Estimates show that the neutron contribution to the total equivalent radiation dose reaches 20-30%.

Benton, E. V.↗