Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Display Devices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

A device-dependent interface for interactive image display

The structure of the device independent Display Management Subsystem (DMS) and the interface routines that are available to the applications programmer for use in developing a set of portable image display utility programs are described.

Perkins, D. C.↗

Research Needs for Developing Qualification Standards for Flight Simulation Training Devices with Head Mounted Displays

This presentation discusses research needs to support evidence-based qualification standards for Flight Simulation Training Devices (FSTDs) with head mounted displays (HMDs). Currently, the FAA and EASA have no qualification standards specifically for FSTDs using HMDs and extended reality (XR) visuals, and existing qualification standards may not be sufficient. Special Conditions can be prescribed for the evaluation and qualification of individual devices, but these Special Conditions need to be assessed and adjusted on a case-by-case basis resulting in an elaborate process. Furthermore, test tolerances used in Special Conditions are often based on conventional visual systems and may not be adequate. This presentation first identifies gaps in the current knowledge of using HMDs in pilot training, and, more specifically, using HMDs in the training of manual aircraft control with motion cues. Next, research is proposed to help close these gaps, inform the development of qualification criteria and tolerances, and guide efforts to update regulations. The Vertical Motion Simulator (VMS) at NASA Ames Research Center, with its large motion capability, is currently undergoing significant upgrades including a state-of-the-art out-the-window visual system. In addition, an HMD capability will be introduced to use in conjunction with the conventional visual system. With its long history of setting standards in the simulation industry, the VMS is the ultimate tool to conduct research that could help accelerate the development of standards for the use of HMDs in FSTDs. The goal of the talk is ultimately to spark a discussion about the research needs and priorities to best serve the development of new qualification standards.

XR↗

Semiconductor-based, large-area, flexible, electronic devices on {110}<100> oriented substrates

Novel articles and methods to fabricate the same resulting in flexible, oriented, semiconductor-based, electronic devices on {110}<100> textured substrates are disclosed. Potential applications of resulting articles are in areas of photovoltaic devices, flat-panel displays, thermophotovoltaic devices, ferroelectric devices, light emitting diode devices, computer hard disc drive devices, magnetoresistance based devices, photoluminescence based devices, non-volatile memory devices, dielectric devices, thermoelectric devices and quantum dot laser devices.

36 MATERIALS SCIENCE↗

[100] or [110] aligned, semiconductor-based, large-area, flexible, electronic devices

Novel articles and methods to fabricate the same resulting in flexible, large-area, [100] or [110] textured, semiconductor-based, electronic devices are disclosed. Potential applications of resulting articles are in areas of photovoltaic devices, flat-panel displays, thermophotovoltaic devices, ferroelectric devices, light emitting diode devices, computer hard disc drive devices, magnetoresistance based devices, photoluminescence based devices, non-volatile memory devices, dielectric devices, thermoelectric devices and quantum dot laser devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electrothermal follow display apparatus for electroexplosive device testing

A self-balancing bridge for ascertaining the electrothermal and nonlinear behavior of an electroexplosive device is described. A sinusiodal current is passed through the device which provides a signal in the form of a unique Lissajous display. The display can be qualitatively evaluated and abnormal units can be readily detected.

Rosenthal, L. A.↗

A device-independent interface for interactive image display

NASA's Goddard Space Flight Center (GSFC) has developed a Transportable Applications Executive (TAE) for use in implementing portable applications software that can be shared by different research projects. Since many of the supported disciplines require the interactive display and manipulation of remotely sensed images, a device independent Display Management Subsystem (DMS) was written as a TAE extension. The DMS attempts to abstract and standardize the device dependent functions that are used in the display and manipulation of image data on image analysis terminals. This paper explores the concept of DMS and the interface routines that are available to the applications programmer for use in developing a set of portable image display utility programs.

Perkins, D. C.↗

Phototelevision data display methods

Phototelevision devices (PTD) used to graphically display the results obtained from computerized data processing are described. The possibility and specifics of the use of PTD with a digital computer are presented. Requirements are formulated, and the principles used in the design of the PTD are given. General problems in interfacing the PTD and the digital computer are discussed. Recommendations are included.

Avanesov, G. A.↗

The Fundamentals of Using the Digital Micromirror Device (DMD(TM)) for Projection Display

Developed by Texas Instruments (TI) the digital micromirror device (DMD(tm)) is a quickly emerging and highly useful micro-electro-mechanical structures (MEMS) device. Using standard semiconductor fabrication technology, the DMD's simplicity in concept and design will provide advantageous solutions for many different applications. At the rudimentary level, the DMD is a precision, semiconductor light switch. In the initial commercial development of DMD technology, TI has concentrated on projection display and hardcopy. This paper will focus on how the DMD is used for projection display. Other application areas are being explored and evaluated to find appropriate and beneficial uses for the DMD.

Yoder, Lars A.↗

Advanced C and D techniques and application study

A study was conducted to identify a broad base of payload control and display requirements for space missions. The subjects discussed are: (1) functional requirements and allocation analysis, (2) control and display generic device matrix, (3) control functional requirements, and (4) display functional requirements. Specific applications of payload control and display requirements for various disciplines are defined.

Kendall, K.↗

Grayscale/resolution trade-off for text: Model predictions and psychophysical results for letter confusion and letter discrimination

In a series of papers presented in 1994, we examined the grayscale/resolution trade-off for natural images displayed on devices with discrete pixellation, such as AMLCD's. In the present paper we extend this study by examining the grayscale/resolution trade-off for text images on discrete-pixel displays. Halftoning in printing is an example of the grayscale/resolution trade-off. In printing, spatial resolution is sacrificed to produce grayscale. Another example of this trade-off is the inherent low-pass spatial filter of a CRT, caused by the point-spread function of the electron beam in the phosphor layer. On a CRT, sharp image edges are blurred by this inherent low-pass filtering, and the block noise created by spatial quantization is greatly reduced. A third example of this trade-off is text anti-aliasing, where grayscale is used to improve letter shape, size and location when rendered at a low spatial resolution. There are additional implications for display system design from the grayscale/resolution trade-off. For example, reduced grayscale can reduce system costs by requiring less complexity in the framestore, allowing the use of lower cost drivers, potentially increasing data transfer rates in the image subsystem, and simplifying the manufacturing processes that are used to construct the active matrix for AMLCD (active-matrix liquid-crystal display) or AMTFEL (active-matrix thin-film electroluminescent) devices. Therefore, the study of these trade-offs is important for display designers and manufacturing and systems engineers who wish to create the highest performance, lowest cost device possible. Our strategy for investigating this trade-off is to generate a set of simple test images, manipulate grayscale and resolution, predict discrimination performance using the ViDEOS(Sarnoff) Human Vision Model, conduct an empirical study of discrimination using psychophysical procedures, and verify the computational results using the psychophysical results.

Gille, Jennifer↗

Doppler detection of decompression bubbles with computer assisted digitization of ultrasonic signals

The use of an inexpensive, commercially available audio digitizer in conjunction with a PC to digitize Doppler bubble signals for visual and electronic evaluation is reported. This device can be operated simultaneously with Doppler audio monitoring. Precordial and arterial Doppler recordings of gas bubbles were obtained from anesthetized dogs after intravascular infusion or following decompression. Additional evaluations were conducted on Doppler bubble recordings obtained from human decompression studies. The device can be used in real-time or for later signal analysis. Accompanying menu-driven software provides for numerous signal modification options and visual displays. This device can provide a simultaneous visual display of Doppler signals normally available only for audio evaluation.

Butler, B. D.↗

A survey of laser display

Laser display systems, discussing mechanical, diffractive and refractive beam deflection techniques, electro-optical polarization devices, holographic displays, etc

Devaney, A. J.↗

Video System for Viewing From a Remote or Windowless Cockpit

A system of electronic hardware and software synthesizes, in nearly real time, an image of a portion of a scene surveyed by as many as eight video cameras aimed, in different directions, at portions of the scene. This is a prototype of systems that would enable a pilot to view the scene outside a remote or windowless cockpit. The outputs of the cameras are digitized. Direct memory addressing is used to store the data of a few captured images in sequence, and the sequence is repeated in cycles. Cylindrical warping is used in merging adjacent images at their borders to construct a mosaic image of the scene. The mosaic-image data are written to a memory block from which they can be rendered on a head-mounted display (HMD) device. A subsystem in the HMD device tracks the direction of gaze of the wearer, providing data that are used to select, for display, the portion of the mosaic image corresponding to the direction of gaze. The basic functionality of the system has been demonstrated by mounting the cameras on the roof of a van and steering the van by use of the images presented on the HMD device.

Banerjee, Amamath↗

Intercomparison of Commercially Available Active Radon Measurement Devices in a Discovered Radon Chamber

An unventilated 70 m 3 underground space, with 2.1 m high ceilings and an inner set of concrete walls to damp vibrations, was discovered to have relatively stable radon levels of ~1,080 Bq m -3 over a 1-y period. The addition of radium sources was not required to achieve high and somewhat variable radon levels, as these arise naturally in the space. Several active radon monitoring devices designed for homeowners, radon screeners, radon mitigation professionals, and researchers were tested in the space. These devices were variable in both cost and intended user sophistication. Data were collected at specific time intervals that varied for each device. A cellphone was deployed with an available camera application to periodically capture photographs of the displays of devices not enabled for automatic temporal recording. Attempts were made to alter the radon concentration using fans, radium-laden objects, and radon impermeable sheets. Statistical methods were employed to compare the device's performance under the minor radon transients produced by the addition of 226 Ra sources during the test period. The evaluation of the overall accuracy, noise, and response to transients revealed highly affordable devices that may be useful for future research applications.While unsuitable for precise calibrations at stable radon levels, the space was determined to be adequate as a radon chamber for general research purposes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Aircraft control position indicator

An aircraft control position indicator was provided that displayed the degree of deflection of the primary flight control surfaces and the manner in which the aircraft responded. The display included a vertical elevator dot/bar graph meter display for indication whether the aircraft will pitch up or down, a horizontal aileron dot/bar graph meter display for indicating whether the aircraft will roll to the left or to the right, and a horizontal dot/bar graph meter display for indicating whether the aircraft will turn left or right. The vertical and horizontal display or displays intersect to form an up/down, left/right type display. Internal electronic display driver means received signals from transducers measuring the control surface deflections and determined the position of the meter indicators on each dot/bar graph meter display. The device allows readability at a glance, easy visual perception in sunlight or shade, near-zero lag in displaying flight control position, and is not affected by gravitational or centrifugal forces.

Dennis, Dale V.↗

Simultaneous EKG and ultrasonoscope display

Display of two dimensional image of heart and EKG waveform concurrently on same cathode-ray, is achieved by device. Concurrent display allows continuous comparision of dimensional changes in heart and periodicity of EKG waveform.

Lee, R. D.↗