Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Defect detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Active Thermography Based on Tensor Rank Decomposition

Principal Component Thermography applies Singular Value Decomposition (SVD) to post-process data that are derived from active thermographic inspections. SVD provides useful compression of the data and allows for better understanding of substructure and indications of potential damage. In the standard approach, SVD is applied to a certain reshaping of a three-dimensional data stack into a two-dimensional array. This work applies the CANDECOMP-PARAFAC (CP) tensor rank decomposition directly to the three-dimensional data to avoid the initial reshaping step in order to begin to develop an inspection method that can more accurately detect defects in non-homogeneous and anisotropic materials. Tests against simulated data that compare the CP decomposition method with traditional Principal Component Thermography based on SVD are described. Finally, the method of Proper Generalized Decomposition (PGD) is used to derive the CP decomposition, and its performance against other algorithms is also discussed.

Thermography↗

Simurgh: A Framework for Cad-Driven Deep Learning Based X-Ray CT Reconstruction

High-resolution X-ray computed tomography (XCT) is an important technique for the inspection of additively manufactured (AM) parts. While XCT is typically used off-line to inspect a subset of manufactured parts, significantly accelerating measurement speed while retaining accuracy would enable use of XCT for in-line inspection to rapidly identify defects in each part as it is manufactured. Here, we propose a deep learning (DL) based approach that uses computer aided design (CAD) models of the AM parts and physics-based information to rapidly produce high-quality reconstructions from sparse XCT measurements without high quality ground truth data. Our approach uses a generative adversarial neural network (GAN) to produced realistic training data from the CAD-based simulations and a deep neural network that is trained using data from the first stage to produce accurate 3D reconstructions. Using experimental XCT data of metal parts, we demonstrate enhanced defect detection capabilities while dramatically reducing the scan time.

Ziabari, Amir↗

Integrating Predictions for Improving Defect Classification Accuracy in NDT-based Assessment of Concrete - 20229

There is an increasing need to create predictive models for defect classification in concrete using the output of non-destructive testing (NDT) techniques. Recent advancement of machine-learning algorithms has offered several techniques for developing classification models for different types of data sets. However, the performance of these algorithms is very uncertain, mainly when applied to small and noisy datasets. For example, when human access is limited (e.g., nuclear facility), robot-based NDT is preferred. But compared to manual tests with humans present on site, the data sets are small, and more noise can exist. Therefore, it is imperative to develop new approaches to ensure a consistently high classification accuracy for inadequate data sets. This study explores the classification performance on NDT dataset using classifiers from different machine-learning algorithms, namely k-Nearest Neighbor (kNN), Decision Tree, Naive Bayes, Logistic Regression, and Support Vector Machine (SVM). The authors further integrated the predictions from these classifiers using proposed methods. The integration strategy combines the output of the classifiers based on two different measures, accuracy, and performance (ACC and PERF), using equations such as sum, average, and square-root-of-sums-of-squares (SRSS). Our results reveal varying classification accuracies across individual classifiers with different misclassifications across the test data set. The integration strategy provided significant improvement in the classification accuracy compared to the individual classifiers. Furthermore, the results indicate minimal variation across the integration methods as compared to the variation across the individual classifiers. To conclude, prediction integration offers a unique approach for combining the output of multiple classifiers to create redundancies with the potential of achieving high classification performance and improved reliability in predictive models for defect detection in concrete. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Towards in-situ certification of additively manufactured parts: the vital roles of physics-based and data-driven models

Certifying additively manufactured (AM) parts in-situ at the completion of a build is an enticing prospect, as it can help reduce the high costs associated with post-build testing and evaluation. However, achieving this goal presents significant challenges that may keep it aspirational for the foreseeable future. Nonetheless, incremental progress can pave the way forward. A critical aspect of in-situ certification involves continuous quality checking due to the random nature of the AM process and the difficulties in detecting defects or anomalies once layers are built over. While real-time in-situ monitoring strategies assisted by machine learning (ML) play a pivotal role in auditing part quality, they must ideally be supported by real-time (or near real-time) adaptive process control enabled by ML-assisted decision-making. By analyzing in-situ monitoring data in real-time (or near real- time) to dynamically adjust manufacturing parameters, such intervention can ensure AM parts are built to meet stringent certification standards. This can be achieved virtually by using high-fidelity performance models for the physical testing and evaluation tasks. In this short editorial, we discuss the key contributions made by data-driven and physics-based models in providing intelligence to the monitoring and process control tasks underpinning in-situ certification and in the simulation of the build’s performance under test and service conditions. While our focus lies in metal AM, the concepts discussed here are also relevant to other AM processes.

: In-situ monitoring↗

Ultrasonic detection of bearing defects

Experimental study shows that various sensors can be used to detect and monitor vibrations and stress waves emitted by defective bearings, giving early warning of impending bearing failure.

Ensor, L. C.↗

Method of Generating X-Ray Diffraction Data for Integral Detection of Twin Defects in Super-Hetero-Epitaxial Materials

A method provides X-ray diffraction (XRD) data suitable for integral detection of a twin defect in a strained or lattice-matched epitaxial material made from components having crystal structures having symme try belonging to different space groups. The material is mounted in a n X-ray diffraction (XRD) system. In one embodiment, the XRD system's goniometer angle Omega is set equal to (Theta(sub B)-Beta) where The ta(sub B) is a Bragg angle for a designated crystal plane of the allo y that is disposed at a non-perpendicular orientation with respect to the {111) crystal plane, and Beta is the angle between the designate d crystal plane and a { 111 } crystal plane of one of the epitaxial components. The XRD system's detector angle is set equal to (Theta(su b B)+Beta). The material can be rotated through an angle of azimuthal rotation Phi about the axis aligned with the material. Using the det ector, the intensity of the X-ray diffraction is recorded at least at the angle at which the twin defect occurs.

Park, Yeonjoon↗

Photorefractor ocular screening system

A method and apparatus for detecting human eye defects, particularly detection of refractive error is presented. Eye reflex is recorded on color film when the eyes are exposed to a flash of light. The photographs are compared with predetermined standards to detect eye defects. The base structure of the ocular screening system is a folding interconnect structure, comprising hinged sections. Attached to one end of the structure is a head positioning station which comprises vertical support, a head positioning bracket having one end attached to the top of the support, and two head positioning lamps to verify precise head positioning. At the opposite end of the interconnect structure is a camera station with camera, electronic flash unit, and blinking fixation lamp, for photographing the eyes of persons being evaluated.

Richardson, John R.↗

Effects of digital fringe projection operational parameters on detecting powder bed defects in additive manufacturing

Additive manufacturing is a technology transforming traditional production timelines. Specifically, metal additive manufacturing (MAM) has been increasingly adopted by a variety of industries, not only to prototype, but also to fulfill full production scale applications with much lower lead times. Like any maturing manufacturing technology, developments in verifying and validating processes are necessary to support continuous growth. Due to the complex nature of MAM, part quality and repeatability remain integral challenges that inhibit further adoption of MAM for critical component production. In this study, we present data taken from a developing in-process monitoring system designed to measure and detect powder bed defects (PBDs) in powder bed fusion MAM systems using surface height maps created with structured light illumination. We showcase the feasibility of the monitoring technique for in-process implementation by detecting streak PBDs with varying severities (height, width) created in a lab environment. We present results of powder bed measurements for varying experimental parameters of the structured light system such as illumination angle, illumination pattern, and number of illuminations. We also present an expression used to determine experimental height noise based on input parameters for PBD detection based on the instrument transfer function of the structured light monitoring system for arbitrary pixel intensity noise contributions. In conclusion, with the results of PBD detection across multiple experimental measurement parameters, we provide a best practices approach to in-process implementation of the monitoring system in powder bed fusion manufacturing.

36 MATERIALS SCIENCE↗

NASA Hybrid Reflectometer Project

Time-domain and frequency-domain reflectometry have been used for about forty years to locate opens and shorts in cables. Interpretation of reflectometry data is as much art as science. Is there information in the data that is being missed? Can the reflectometers be improved to allow us to detect and locate defects in cables that are not outright shorts or opens? The Hybrid Reflectometer Project was begun this year at NASA Ames Research Center, initially to model wire physics, simulating time-domain reflectometry (TDR) signals in those models and validating the models against actual TDR data taken on testbed cables. Theoretical models of reflectometry in wires will give us an understanding of the merits and limits of these techniques and will guide the application of a proposed hybrid reflectometer with the aim of enhancing reflectometer sensitivity to the point that wire defects can be detected. We will point out efforts by some other researchers to apply wire physics models to the problem of defect detection in wires and we will describe our own initial efforts to create wire physics models and report on testbed validation of the TDR simulations.

Lynch, Dana↗

Method and apparatus for detecting flaws and defects in heat seals

Flaws and defects in heat seals formed between sheets of translucent film are identified by optically examining consecutive lateral sections of the seal along the seal length. Each lateral seal section is illuminated and an optical sensor array detects the intensity of light transmitted through the seal section for the purpose of detecting and locating edges in the heat seal. A line profile for each consecutive seal section is derived having an amplitude proportional to the change in light intensity across the seal section. Instances in the derived line profile where the amplitude is greater than a threshold level indicate the detection of a seal edge. The detected edges in each derived line profile are then compared to a preset profile edge standard to identify the existence of a flaw or defect.

Rai, Kula R.↗

Are Soft Short Tests Good Indicators of Internal Li-ion Cell Defects?

The self discharge test at full state of charge, may not be a good one to detect subtle defects since the li-ion chemistry has the highest self discharge at full state of charge. One should characterize self discharge versus storage time for each cell manufacturer/design to differentiate between normal self discharge and that due to a subtle manufacturing defect. The various soft short test methods indicate that if this test is carried out at full discharge (0% SOC) with all capacity removed (by lowering the current load in a stepwise manner to the same end of discharge voltage), then the cells need to be placed in storage for more than 72 hours to get a good analysis on the presence of subtle defects since it takes more than 72 hours to achieve voltage stabilization. If the cells are to be charged up even to a small percentage (ex. 1%), 72 hours are sufficient to determine issues. However, the pass/fail criteria should be based on a valid OCV decline. Less than 10 mV voltage decline is not a good method to detect subtle defects. As mentioned in the first bullet, self discharge is a competing reaction when a charge is introduced and hence a characterization of the self discharge versus storage time is required to fully correlate voltage decline to a failure due to a subtle defect. Soft short test method cannot be relied on for defect detection because cells with and without voltage decline seemed to have similar defects and characteristics. Screening methods such as internal resistance and capacity as well as a 3-sigma range for OCV, mass and dimensions should be used to screen out outliers. A very critical aspect in the understanding of subtle defects is to carry out destructive analysis of cells from every lot to confirm the quality of production and screen all cells and batteries in a stringent manner to have a high quality set of flight cells. Self Discharge Test: Fully charged cells shall be placed in Open circuit stand for 72 hours (OCV measurement twice a day); continue for total of 14 days with 1 reading per day 2. Soft Short Test 1: Fully charge; cells discharged to manufacturer's end of disch. Voltage (EODV) cutoff at C/5 rate; stand for 30 minutes; discharge with C/500 to the same EODV. stand for another 30 minutes; discharge the cells again using C/1000 current to the same EODV. OCV measurements twice a day for 72 hours and then for total of 14 days (data collection same as in 1.) 3. Soft Short Test 2: Fully charge; cells discharged to the manuf. EODV with a C/13 constant current; provide a 10 hour rest, discharge again to the same EODV with a current of C/250, provide a 10 hour rest, discharge again using a C/250 rate, provide a 24 hour rest, charge using C/250 to 3.15 V (for ~12 hours). OCV measurements twice a day for at 72 hours. (data collection same as in 1.) 4. Soft Short Test 3: Fully charge; cells shall be discharged using C/10 current to manuf. EODV. Allow the cell to remain at Open circuit for 10 seconds. Discharge the cell at C/20 rate to the same EODV, hold open circuit for 24 hours. Discharge the cells at C/200 rate to the same end of voltage cutoff and hold open circuit for 24 hours. Discharge the cells one more time at C/200 rate to the same EODV and hold open circuit for 36 hours. Charge at C/200 rate to 3.15 V and hold for 3 days. Record OCV during the open circuit stand periods every 12 hours and at the beginning and end of the 3 day hold (include the 12 hour OCV recording during this time also). Capacity Cycling: Cells with declining voltages - one cell from each manufacturer chosen for cycling Destructive Physical Analysis (DPA): Cells with and without decline chosen from each lot for DPA.

Jeevarajan, J.↗

Low Temperature SQUID for NDE Applications

We have developed a low temperature SuperConducting Quantum Interference Device - SQUID measurement system for detection of defects deep under the surface of aluminum structures using eddy current techniques. The system uses a two dimensional planar inducer with two different excitation frequencies to induce a current in the sample. We have developed a data analysis software program that enabled us to distinguish between round defects (holes), straight defects (slots) and slots close to holes simulating cracks starting from rivets in aluminum structures. We were able to detect defects that are 8mm below the surface. We have also measured the change in phase of the detected signal as a function of depth of the defect. This relationship can be used to determine the depth of hidden flaws. Using this analysis software with the high temperature SQUID system at NASA Langley we were able to detect slots close to holes in layered aluminum sample.

Wincheski, Buzz↗

Large Area Detection of Microstructural Defects with Multi-Mode Ultrasonic Signals

Cyclic loading or other stresses can lead to development of cracks and crack growth in mechanical structures, leading to eventual failure. While ultrasound imaging can be used for non-destructive testing of such structures, conventional ultrasound techniques are often limited by crack size, density, and areal coverage. An effective characterization of real-world, large-area structures is required at an early damage stage to prevent catastrophic failure and predict remaining life. In this study, a new nonlinear ultrasonic testing (NUT) method is proposed for large-area monitoring of practical structures with arbitrary complexity by using multiple-mode guided-wave ultrasonic signals. The proposed guided-wave NUT technique requires single-element transducers, simple electronics, and a mixed time-frequency domain signal processing. As a proof-of-concept demonstration, numerical simulations and experiments are performed on an A36 carbon steel beam assembly with previously formed microstructural defects that cause nonlinearities in ultrasonic response. The quadratic dependence of the nonlinear wave excitation on the input ultrasonic signal amplitude is shown by numerical simulations, and such a nonlinear ultrasonic response is experimentally observed in the zone with a high density of microstructural defects.

36 MATERIALS SCIENCE↗

Detection of tanker defects with infrared thermography

Infrared scanning technique for finding defects in secondary barrier of liquid natural gas (LNG) tank has been successfully tested on ship under construction at Newport News Shipbuilding and Dry Dock Company. Technique determines defects with minimal expenditure of time and manpower. Tests could be repeated during life of tanker and make more complicated testing unnecessary. Tests also confirmed that tank did not have any major defects, and tank was certified.

Kantsios, A. G.↗

Surface Inspection Tool for Optical Detection of Surface Defects

The Space Shuttle Orbiter windows were damaged both by micrometeor impacts and by handling, and required careful inspection before they could be reused. The launch commit criteria required that no defect be deeper than a critical depth. The shuttle program used a refocus microscope to perform a quick pass/fail determination, and then followed up with mold impressions to better quantify any defect. However, the refocus microscope is slow and tedious to use due to its limited field of view, only focusing on one small area of glass at a time. Additionally, the unit is bulky and unable to be used in areas with tight access, such as defects near the window frame or on the glass inside the Orbiter due to interference with the dashboard. The surface inspection tool is a low-profile handheld instrument that provides two digital video images on a computer for monitoring surface defects. The first image is a wide-angle view to assist the user in locating defects. The second provides an enlarged view of a defect centered in the window of the first image. The focus is adjustable for each of the images. However, the enlarged view was designed to have a focal plane with a short depth. This allows the user to get a feel for the depth of different parts of the defect under inspection as the focus control is varied. A light source is also provided to illuminate the defect, precluding the need for separate lighting tools. The software provides many controls to adjust image quality, along with the ability to zoom digitally the images and to capture and store them for later processing.

Nurge, Mark↗

Local Ultrasonic Resonance Spectroscopy of Lithium Metal Batteries for Aerospace Applications

As next-generation aircraft and vehicles continue to develop, so do their associated energy demands. Lithium metal batteries are a leading candidate to fulfill this energy requirement, but these batteries are prone to internal dendrite defects that can lead to catastrophic thermal runaway events. Current battery management systems are capable of mitigating such risks, but are unable to detect such defects until thermal runaway has already begun. Various nondestructive evaluation (NDE) techniques, particularly ultrasonic NDE, can directly monitor internal battery parameters giving them the potential to detect critical defects prior to catastrophic failure. However, most of the current battery NDE research has focused on improved battery state-of-charge (SOC) and stateof- health (SOH) monitoring with little emphasis on critical defect detection. Thus, a measurement technique sensitive to subtle battery defects is needed. In addition, the complex mechanics of ultrasound in porous, thin, multilayered batteries prompt the use of physics-based simulation to guide inspections. In this work, an ultrasonic NDE technique has been developed utilizing frequency domain analysis of local battery resonances to detect the presence of battery defects. This technique is a practical extension of local ultrasonic resonance spectroscopy (LURS) – which previously required non-contact laser ultrasonics – to measurements with piezoelectric contact and immersion scan transducers. To extend the technique to work with piezoelectric transducers, ultrasonic battery measurements were compared to a sans-battery calibration measurement. Then, a linear systems deconvolution was used to eliminate the transfer functions of extraneous factors such as the transducer and electronics, leaving only the frequency-dependent battery reflection coefficient. The LURS technique was first validated on stainless steel and aluminum plates, producing reflection coefficients in line with analytical and numerical finite element modeling (FEM) results. Functioning Li-metal pouch cells were then seeded with lithium chip defects prior to LURS measurements. The presence of these defects is shown to cause a measurable shift in the battery’s through-thickness local resonances. 2D, frequency-domain poroelastic models of ultrasonic propagation in a single-cell lithium metal pouch battery were created and corroborated these findings. Thus, this work has both extended and proven the feasibility of the LURS technique in the detection of local battery defects.

Ultrasound↗