Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “December 2010”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Summary of Surface Swipe Sampling for Beryllium on Lead Bricks and Shielding

Approximately 25,000 lbs of lead bricks at Site 300 were assessed by the Site 300 Industrial Hygienis tand Health Physicist for potential contamination of beryllium and radiation for reuse. These lead bricks and shielding had been used as shielding material during explosives tests that included beryllium and depleted uranium. Based on surface swipe sampling that was performed between July 26 and October 11, 2010, specifically for beryllium, the use of a spray encapsulant was found to be an effective means to limit removable surface contamination to levels below the DOE release limit for beryllium, which is 0.2 mcg/100 cm{sup 2}. All the surface swipe sampling data for beryllium and a timeline of when the samples were collected (and a brief description) are presented in this report. On December 15, 2010, the lead bricks and shielding were surveyed with an ion chamber and indicated dose rates less than 0.05 mrem per hour on contact. This represents a dose rate consistent with natural background. An additional suevey was performed on February 8, 2011, using a GM survey instrument to estimate total activity on the lead bricks and shielding, confirming safe levels of radioactivity. The vendor is licensed to possess and work with radioactive material.

61 RADIATION PROTECTION AND DOSIMETRY↗

Upgrades to meet LANL SF, 121-2011, hazardous waste facility permit requirements

Members of San IIdefonso have requested information from LANL regarding implementation of the revision to LANL's Hazardous Waste Facility Permit (the RCRA Permit). On January 26, 2011, LANL staff from the Waste Disposition Project and the Environmental Protection Division will provide a status update to Pueblo members at the offices of the San IIdefonso Department of Environmental and Cultural Preservation. The Waste Disposition Project presentation will focus on upgrades and improvements to LANL waste management facilities at TA-50 and TA-54. The New Mexico Environment Department issued LANL's revised Hazardous Waste Facility permit on November 30, 2010 with a 30-day implementation period. The Waste Disposition Project manages and operates four of LANL's permitted facilities; the Waste Characterization, Reduction and Repackaging Facility (WCRRF) at TA-SO, and Area G, Area L and the Radioassay and Nondestructive Testing facility (RANT) at TA-54. By implementing a combination of permanent corrective action activities and shorter-term compensatory measures, WDP was able to achieve functional compliance on December 30, 2010 with new Permit requirements at each of our facilities. One component of WOP's mission at LANL is centralized management and disposition of the Laboratory's hazardous and mixed waste. To support this mission objective, WOP has undertaken a project to upgrade our facilities and equipment to achieve fully compliant and efficient waste management operations. Upgrades to processes, equipment and facilities are being designed to provide defense-in-depth beyond the minimum, regulatory requirements where worker safety and protection of the public and the environment are concerned. Upgrades and improvements to enduring waste management facilities and operations are being designed so as not to conflict with future closure activities at Material Disposal Area G and Material Disposal Area L.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

STS-133/ET-137 Tanking Test Photogrammetry Assessment

Following the launch scrub of Space Shuttle mission STS-133 on November 5, 2010, an anomalous condition of cracked and raised thermal protection system (TPS) foam was observed on the External Tank (ET). Subsequent dissection of the affected TPS region revealed cracks in the feet of two Intertank (IT) metallic stringers. An extensive investigation into the cause(s) and corrective action(s) for the cracked stringers was initiated, involving a wide array of material and structural tests and nondestructive evaluations, with the intent to culminate into the development of flight rational. One such structural test was the instrumented tanking test performed on December 17, 2010. The tanking test incorporated two three-dimensional optical displacement measurement systems to measure full-field outer surface displacements of the TPS surrounding the affected region that contained the stringer cracks. The results showed that the radial displacement and rotation of the liquid oxygen (LO2) tank flange changed significantly as the fluid level of the LO2 approached and passed the LO2 tank flange.

Oliver, Stanley T.↗

Lunar Reconnaissance Orbiter (LRO) Thermal On-Orbit Performance

The Lunar Reconnaissance Orbiter (LRO) was launched on June 18, 2009. The nominal mission ended on September 15, 2010 and LRO is now on a four-year extended mission. The LRO performances in hot and cold cases are compared to pre-launch analysis predicts, and operational lessons learned are discussed. One instrument has required tighter-than-anticipated thermal control, and two others have frequently requested unanticipated calibration maneuvers that had to be evaluated for their thermal performance. A series of off nadir thermal analyses of the entire orbiter were performed prior to launch, and these predictions are compared to actual maneuvers, with a discussion of the process by which maneuvers can be rapidly evaluated for thermal concerns. On December 21st, 2010, LRO experienced its first severe Lunar Eclipse. Operationally, this required the Spacecraft to pre-heat its main avionics panel in order to minimize control heater power during the period when the Earth blocks the sun from the moon. The operational design and in-flight performance are summarized.

Baker, Charles↗

Early Significant Tumor Volume Reduction After Radiosurgery in Brain Metastases From Renal Cell Carcinoma Results in Long-Term Survival

Purpose: To retrospectively evaluate survival of patients with brain metastasis from renal cell carcinoma (RCC) after radiosurgery. Patients and Methods: Between 1998 and 2010, 46 patients were treated with radiosurgery, and the total number of lesions was 99. The mean age was 58.9 years (range, 33-78 years). Twenty-six patients (56.5%) had a single brain metastasis. The mean tumor volume was 3.0 cm{sup 3} (range, 0.01-35.1 cm{sup 3}), and the mean marginal dose prescribed was 20.8 Gy (range, 12-25 Gy) at the 50% isodose line. A patient was classified into the good-response group when the sum of the volume of the brain metastases decreased to less than 75% of the original volume at a 1-month follow-up evaluation using MRI. Results: As of December 28, 2010, 39 patients (84.8%) had died, and 7 (15.2%) survived. The overall median survival time was 10.0 {+-} 0.4 months (95% confidence interval, 9.1-10.8). After treatment, local tumor control was achieved in 72 (84.7%) of the 85 tumors assessed using MRI after radiosurgery. The good-response group survived significantly longer than the poor-response group (median survival times of 18.0 and 9.0 months, respectively; p = 0.025). In a multivariate analysis, classification in the good-response group was the only independent prognostic factor for longer survival (p = 0.037; hazard ratio = 0.447; 95% confidence interval, 0.209-0.953). Conclusions: Radiosurgery seems to be an effective treatment modality for patients with brain metastases from RCC. The early significant tumor volume reduction observed after radiosurgery seems to result in long-term survival in RCC patients with brain metastases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clearance Analysis of CTC2 (on ELC4) to S-TRRJ HRS Radiator Rotation Envelope

In response to the planned retirement of the Space Shuttle Program, International Space Station (ISS) management began stockpiling spare parts on the ISS. Many of the larger orbital replacement units were stored on the Expedite the Processing of Experiments to Space Station (EXPRESS) Logistics Carriers (ELCs) mounted on the end of the S3 and P3 truss segments, immediately outboard of the Thermal Radiator Rotary Joints (TRRJs) and their attached radiators. In an August 2009 computer-aided design (CAD) assessment, it was determined that mounting the Cargo Transport Container (CTC) 2 on the inboard face of ELC4 as planned would create insufficient clearance between the CTC2 and the rotational envelope of the radiators when the TRRJs were rotated to a gamma angle of 35.0 degrees. The true clearance would depend on how the Unpressurized Cargo Carrier Attachment System (UCCAS) was mounted to the S3 truss and how the ELC4 was attached to it. If the plane of the UCCAS attachment points were tilted even slightly inboard, it would significantly change the clearance between CTC2 and the Starboard TRRJ (S-TRRJ) radiators. Additionally, since CTC2 would be covered in multilayer insulation (MLI), the true outer profile of CTC2 was not captured in the CAD models used for the clearance assessment. It was possible that, even if the S-TRRJ radiators cleared CTC2, they could snag the MLI covering. In the fall of 2010, the Image Science and Analysis Group (ISAG) was asked to perform an on-orbit clearance analysis to determine the location of CTC2 on ELC4 and the S-TRRJ radiators at the angle of closest approach so that a positive clearance could be assured. To provide the measurements as quickly as possible to aid in the assessment, it was decided that the clearance analysis would be broken into two phases. Phase I: The location and orientation of the UCCAS fittings, which support and hold the ELC4 in place, would be measured relative to the ISS Analytical Coordinate System (ISSACS) as defined by nine preexisting Space Vision System (SVS) targets affixed to the forward/zenith side of the S1 and S3 truss segments. The location of the outboard edge of the S-TRRJ radiator would also be measured when positioned at the angle of closest approach to CTC2 (gamma = 35.0 degrees). This data would allow the Digital Pre-Assembly Group to predict how the ELC4 would sit on the UCCAS and how that would translate into the clearance between CTC2 and the S-TRRJ radiators. Phase II: After the ELC4 was delivered and installed into the UCCAS, the position of the CTC2 mounting plate on the inboard face of ELC4, would be measured in the ISSACS coordinate system relative to the SVS control points used in Phase I. Although CTC2 would not yet be mounted on ELC4, the working envelope of CTC2 could be mathematically added to the measured position of ELC4 to produce a best estimate for CTC2's mounted location. Comparing CTC2's best estimated location to the S-TRRJ radiator (measured in Phase I); relative to the ISSACS coordinate system, would provide a direct measurement of the expected clearance. Due to the impending delivery of ELC4 (scheduled for January 2011), planning for the Phase I clearance analysis began immediately. Using the Dynamic Onboard Ubiquitous Graphics (DOUG) program, ISAG designed a way to acquire images of the SVS control points on truss segments S1 and S3, the aft facing edge of the S-TRRJ Heat Rejection Subsystem (HRS) radiator, and the three UCCAS latch mechanisms mounted on the zenith face of the S3 truss using the Space Station Remote Manipulator System (SSRMS). To minimize the number of SSRMS movements, the Special Purpose Dexterous Manipulator (SPDM) would be attached to the SSRMS. This would make it possible to park the SPDM in one position and acquire multiple images by changing the viewing orientation of the SPDM body cameras using the pan/tilt units on which they are mounted. Using this implementation concept, ISAG identified four SSRMS/SPDM positions from which the majority of the needed imagery could be acquired. Five additional images would be acquired using the CP-3 external ISS camera mounted on the S1 truss immediately inboard of ELC4. Based on a photogrammetric simulation, it was estimated that the measured location of the HRS radiator and UCCAS latch points would be accurate to about 0.3 in. in each of the three axes relative to ISSACS. Working with ROBO, ISAG collected 78 images of the ISS December 29, 2010. From this imagery, the best 40 were selected for use in the analysis process. The images were radiometrically enhanced to improve color and contrast and loaded into the FotoG analysis software along with the camera parameters and control data, which consisted of the coordinates for the nine SVS targets on the S1 and S3 trusses in the ISSACS coordinate system.

Liddle, Donn↗

Morphological State as a Predictor for Reintervention and Mortality After EVAR for AAA

Purpose: This study was designed to assess aorto-iliac morphological characteristics in relation to reintervention and all-cause long-term mortality in patients undergoing standard EVAR for infrarenal AAA. Methods: Patients treated with EVAR (Zenith{sup Registered-Sign} Stentgrafts, Cook) between May 1998 and February 2006 were prospectively enrolled in a computerized database where comorbidities and preoperative aneurysm morphology were entered. Reinterventions and mortality were checked until December 1, 2010. Median follow-up time was 68 months. Results: A total of 304 patients were included, of which 86% were men. Median age was 74 years. The reintervention rate was 23.4% (71/304). A greater diameter of the common iliac artery (p = 0.037; hazard ratio (HR) 1.037 [1.002-1.073]) was an independent factor for an increased number of reinterventions. The 30-day mortality rate was 3.0% (9/304). Aneurysm-related deaths due to AAA occurred in 4.9% (15/304). Five patients died due to a concomitant ruptured thoracic aortic aneurysm. The mortality until end of follow-up was 54.3% (165/304). The proportion of deaths caused by vascular diseases was 61.6%. The severity of angulation of the iliac arteries (p = 0.014; HR 1.018 [95% confidence interval (CI) 1.004-1.033]) and anemia (p = 0.044; HR 2.79 [95% CI 1.029-7.556]) remained as independent factors associated with all-cause long-term mortality. The crude reintervention-free survival rate at 1, 3, and 5 years was 84.5%, 64.8%, and 51.6%, respectively. Conclusions: The initial aorto-iliac morphological state in patients scheduled for standard EVAR for AAA seems to be strongly related to the need for reinterventions and long-term mortality.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Thromboembolic Complications after Zenith{sup ®} Low Profile Endovascular Graft for Infrarenal Abdominal Aneurysms

PurposeThe purpose of this study was to objectify and evaluate risk factors for thromboembolic complications after treatment with a Zenith{sup ®} Low Profile Endovascular Graft (Zenith LP). Results were compared with those in the recent literature on endovascular aortic repair (EVAR) and with the thromboembolic complications in the patient group treated with a Zenith Flex Endovascular Graft in our institute in the period before the use of the Zenith LP.Materials and MethodsAll consecutive patients who were suitable for treatment with a Zenith LP endograft between October 2010 and December 2011 were included. The preprocedural computed tomography scan (CT), procedural angiographic images, and the postprocedural CT scans were evaluated for risk factors for and signs of thromboembolic complications. All patients treated between December 2007 and November 2012 with a Zenith Flex endograft were retrospectively evaluated for thromboembolic complications.ResultsIn the study period 17 patients were treated with a LP Zenith endograft. Limb occlusion occurred in 35 % of the patients. Limb occlusions occurred in 24 % of the limbs at risk (one limb occluded twice). In one patient two risk factors for limb occlusion were identified. Between December 2007 and November 2012, a total of 43 patients were treated with a Zenith Flex endograft. No limb occlusion or distal embolization occurred.ConclusionDespite that this was a small retrospective study, the Zenith LP endograft seems to be associated with more frequent thromboembolic complications compared with the known limb occlusion rates in the literature and those of the patients treated with a Zenith Flex endograft in our institute.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stent-Graft Placement with Early Debridement and Antibiotic Treatment for Femoral Pseudoaneurysms in Intravenous Drug Addicts

PurposeExplore the application of endovascular covered stent-graft (SG) placement in femoral pseudoaneurysms in intravenous drug addicts.Materials and MethodsWe evaluated a consecutive series of pseudoaneurysm in intravenous drug addicts treated with SGs from August 2010 to December 2013.Results15 patients with 16 arterial pseudoaneurysms were enrolled in this study. All were males with a mean age of 36.9 years. Hemorrhage was the most common reason (93.8 %) for seeking medical care, and 3 of these patients were in hemorrhagic shock at admission. All patients received broad-spectrum antibiotics, and debridement and drainage were implemented after SG placement. 7 of the 13 cases which had microbiologic results showed mixed infections, while gram-negative bacteria were the major pathogens. Except for 2 patients, who were lost to follow-up, two new pseudoaneurysms formed due to delayed debridement, and one stent thrombosis occurred, none of the remaining cases had SG infection or developed claudication.ConclusionsSG placement controls massive hemorrhage rapidly, gives enough time for subsequent treatment for pseudoaneurysms due to intravenous drug abuse, and reduces the incidence of postoperative claudication. With appropriate broad-spectrum antibiotics and early debridement, the incidence of SG infection is relatively low. It is an effective alternative especially as temporary bridge measure for critical patients. However, the high cost, uncertain long-term prospects, high demand for medical adherence, and the risk of using the conduits for re-puncture call for a cautious selection of patients. More evidence is required for the application of this treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Effect of Stent Cell Geometry on Carotid Stenting Outcomes

PurposeThe aim of this study was to investigate the effect of stent cell geometry on midterm results of carotid artery stenting (CAS).Materials and MethodOne hundred fifty-five patients underwent CAS between February 2010 and December 2012. Ninety-one open- and 84 closed-cell stents were used in this non-randomized, retrospective study. Periprocedural complications were defined as the ones happened during the procedure or within 30 days afterwards. Starting from the 6th month after the procedure, in-stent restenosis was detected with multidetector computed tomography angiography and classified into four groups from focal restenosis to occlusion.ResultsEleven complications were encountered in the periprocedural period (four on the open- and seven on the closed-cell group). Total complication rate was 6.3 % (11/175). No significant difference was detected in terms of periprocedural complications between two groups (p = 0.643). There was statistically significant difference between stent design groups in regard to radiological findings (p = 0.002). Sixteen of open-cell stents and three of closed-cell stents had focal restenosis. One closed-cell stent had diffuse proliferative restenosis and one open-cell stent had total occlusion.ConclusionIn-stent restenosis was more common in open-cell stent group, which have larger free cell area than closed-cell stents. Although our radiologic findings promote us to use closed-cell design if ‘possible’, no difference was detected in terms of clinical outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

{sup 18}F-FDG PET/CT-imaging of left ventricular assist device infection: a retrospective quantitative intrapatient analysis

Background: Despite the use of {sup 18}F-fluorodeoxyglucose ({sup 18}F-FDG) positron emission tomography/computed tomography (PET/CT), diagnosis of a driveline infection in ventricular assist device (LVAD) recipients remains challenging. Our aim was to evaluate the potential of a baseline {sup 18}F-FDG PET/CT (prior to an infection) for the diagnosis of an LVAD-related infection. Methods: We retrospectively selected all LVAD recipients who had undergone two consecutive whole-body {sup 18}F-FDG PET/CT examinations between January 2010 and December 2016. PET/CT was analyzed qualitatively (uptake pattern) and semi-quantitatively (SUV{sub max} and ∆SUV{sub max}). SUV{sub max} was measured and compared in five distinctive volumes of interest along the LVAD driveline. An SUV{sub max} threshold was calculated. Final diagnosis was made by clinical examination, microbiological parameters, and molecular imaging. Results: Thirty patients were enrolled (mean age 54 ± 12 years; 26 male). Mean difference in SUV{sub max} for all five positions between the first and the second PET/CT along the driveline was significantly higher in patients with an LVAD-related infection (mean ∆SUV{sub max} = 4.38 ± 1.44) compared to those without a driveline infection (mean ∆SUV{sub max} = 0.03 ± 0.43), P < 0.05. Applying ROC analysis, an SUV{sub max} threshold of 3.88 resulted in a sensitivity and specificity of 100%, respectively. There were three distinctive uptake patterns in patients with a driveline infection. Conclusion: PET/CT diagnosis in the context of an LVAD-related infection can be improved by comparison to a baseline examination using a distinctive SUV{sub max} threshold.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Predictors of Grade 3 or Higher Late Bowel Toxicity in Patients Undergoing Pelvic Radiation for Cervical Cancer: Results From a Prospective Study

Purpose: The present study investigates relationship between dose–volume parameters and severe bowel toxicity after postoperative radiation treatment (PORT) for cervical cancer. Methods and Materials: From June 2010 to December 2012, a total of 71 patients undergoing PORT were included. Small bowel (SB) and large bowel (LB) loops were contoured 2 cm above the target volume. The volume of SB and LB that received 15 Gy, 30 Gy, and 40 Gy was calculated (V15 SB, V15 LB, V30 SB, V30 LB, V40 SB, V 40 LB). On follow-up, bowel toxicity was scored using Common Terminology Criteria for Adverse Events (CTCAE), version 3.0. A reciever operating characteristic (ROC) curve identified volume thresholds that predicted for grade 3 or higher toxicity with highest specificity. All data was dichotomized across these identified cut-off values. Univariate and multivariate analysis was performed using SPSS, version 15. Results: The median patient age was 47 years (range, 35-65 years). Of the 71 patients, 46 received image-guided intensity modulated radiation therapy, and 25 received conformal radiation (50 Gy in 25 fractions for 5 weeks). Overall, 63 of 71 patients received concurrent chemotherapy. On a median follow-up of 18 months (range, 8-29 months), grade 2 or higher bowel toxicity was seen in 22 of 71 patients (30.9%) and grade 3 or higher bowel toxicity was seen in 9 patients (12.6%). On univariate analysis, V15 SB <275 cc (P=.01), V30 SB <190 cc (P=.02), V40 SB <150 cc (P=.01), and V15 LB <250 cc (P=.03), and V40 LB <90 cc (P=.04) predicted for absence of grade 3 or higher toxicity. No other patient- or treatment-related factors were statistically significant. On multivariate analysis, only V15 SB (P=.002) and V15 LB (P=.03) were statistically significant. Conclusions: V 15 Gy SB and LB are independent predictors of late grade 3 or higher toxicity. Restricting V15 SB and V15 LB to <275 cc and <250 cc can reduce grade 3 or higher toxicity to less than 5%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Once-Daily Radiation Therapy for Inflammatory Breast Cancer

Purpose: Inflammatory breast cancer (IBC) is a rare and aggressive breast cancer variant treated with multimodality therapy. A variety of approaches intended to escalate the intensity and efficacy of radiation therapy have been reported, including twice-daily radiation therapy, dose escalation, and aggressive use of bolus. Herein, we examine our outcomes for patients treated with once-daily radiation therapy with aggressive bolus utilization, focusing on treatment technique. Methods and Materials: A retrospective review of patients with nonmetastatic IBC treated from January 1, 2000, through December 31, 2010, was performed. Locoregional control (LRC), disease-free survival (DFS), overall survival (OS) and predictors thereof were assessed. Results: Fifty-two women with IBC were identified, 49 (94%) of whom were treated with neoadjuvant chemotherapy. All underwent mastectomy followed by adjuvant radiation therapy. Radiation was delivered in once-daily fractions of 1.8 to 2.25 Gy (median, 2 Gy). Patients were typically treated with daily 1-cm bolus throughout treatment, and 33 (63%) received a subsequent boost to the mastectomy scar. Five-year Kaplan Meier survival estimates for LRC, DFS, and OS were 81%, 56%, and 64%, respectively. Locoregional recurrence was associated with poorer OS (P<.001; hazard ratio [HR], 4.1). Extracapsular extension was associated with worse LRC (P=.02), DFS (P=.007), and OS (P=.002). Age greater than 50 years was associated with better DFS (P=.03). Pathologic complete response was associated with a trend toward improved LRC (P=.06). Conclusions: Once-daily radiation therapy with aggressive use of bolus for IBC results in outcomes consistent with previous reports using various intensified radiation therapy regimens. LRC remains a challenge despite modern systemic therapy. Extracapsular extension, age ≤50 years, and lack of complete response to chemotherapy appear to be associated with worse outcomes. Novel strategies are needed in IBC, particularly among these subsets of patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Preoperative Chemoradiation Therapy in Combination With Panitumumab for Patients With Resectable Esophageal Cancer: The PACT Study

Purpose: Preoperative chemoradiation therapy (CRT) has become the standard treatment strategy for patients with resectable esophageal cancer. This multicenter phase 2 study investigated the efficacy of the addition of the epidermal growth factor receptor (EGFR) inhibitor panitumumab to a preoperative CRT regimen with carboplatin, paclitaxel, and radiation therapy in patients with resectable esophageal cancer. Methods and Materials: Patients with resectable cT1N1M0 or cT2-3N0 to -2M0 tumors received preoperative CRT consisting of panitumumab (6 mg/kg) on days 1, 15, and 29, weekly administrations of carboplatin (area under the curve [AUC] = 2), and paclitaxel (50 mg/m{sup 2}) for 5 weeks and concurrent radiation therapy (41.4 Gy in 23 fractions, 5 days per week), followed by surgery. Primary endpoint was pathologic complete response (pCR) rate. We aimed at a pCR rate of more than 40%. Furthermore, we explored the predictive value of biomarkers (EGFR, HER 2, and P53) for pCR. Results: From January 2010 until December 2011, 90 patients were enrolled. Patients were diagnosed predominantly with adenocarcinoma (AC) (80%), T3 disease (89%), and were node positive (81%). Three patients were not resected due to progressive disease. The primary aim was unmet, with a pCR rate of 22%. Patients with AC and squamous cell carcinoma reached a pCR of 14% and 47%, respectively. R0 resection was achieved in 95% of the patients. Main grade 3 toxicities were rash (12%), fatigue (11%), and nonfebrile neutropenia (11%). None of the biomarkers was predictive for response. Conclusions: The addition of panitumumab to CRT with carboplatin and paclitaxel was safe and well tolerated but could not improve pCR rate to the preset criterion of 40%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

THE PALOMAR TRANSIENT FACTORY ORION PROJECT: ECLIPSING BINARIES AND YOUNG STELLAR OBJECTS

The Palomar Transient Factory (PTF) Orion project is one of the experiments within the broader PTF survey, a systematic automated exploration of the sky for optical transients. Taking advantage of the wide (3.{sup 0}5 x 2.{sup 0}3) field of view available using the PTF camera installed at the Palomar 48 inch telescope, 40 nights were dedicated in 2009 December to 2010 January to perform continuous high-cadence differential photometry on a single field containing the young (7-10 Myr) 25 Ori association. Little is known empirically about the formation of planets at these young ages, and the primary motivation for the project is to search for planets around young stars in this region. The unique data set also provides for much ancillary science. In this first paper, we describe the survey and the data reduction pipeline, and present some initial results from an inspection of the most clearly varying stars relating to two of the ancillary science objectives: detection of eclipsing binaries and young stellar objects. We find 82 new eclipsing binary systems, 9 of which are good candidate 25 Ori or Orion OB1a association members. Of these, two are potential young W UMa type systems. We report on the possible low-mass (M-dwarf primary) eclipsing systems in the sample, which include six of the candidate young systems. Forty-five of the binary systems are close (mainly contact) systems, and one of these shows an orbital period among the shortest known for W UMa binaries, at 0.2156509 {+-} 0.0000071 days, with flat-bottomed primary eclipses, and a derived distance that appears consistent with membership in the general Orion association. One of the candidate young systems presents an unusual light curve, perhaps representing a semi-detached binary system with an inflated low-mass primary or a star with a warped disk, and may represent an additional young Orion member. Finally, we identify 14 probable new classical T-Tauri stars in our data, along with one previously known (CVSO 35) and one previously reported as a candidate weak-line T-Tauri star (SDSS J052700.12+010136.8).

79 ASTRONOMY AND ASTROPHYSICS↗

OBSERVATIONS OF THE BLAZAR 3C 66A WITH THE MAGIC TELESCOPES IN STEREOSCOPIC MODE

We report new observations of the intermediate-frequency peaked BL Lacertae object 3C 66A with the MAGIC telescopes. The data sample we use were taken in 2009 December and 2010 January, and comprises 2.3 hr of good quality data in stereoscopic mode. In this period, we find a significant signal from the direction of the blazar 3C 66A. The new MAGIC stereoscopic system is shown to play an essential role for the separation between 3C 66A and the nearby radio galaxy 3C 66B, which is at a distance of only 6'. The derived integral flux above 100 GeV is 8.3% of the Crab Nebula flux and the energy spectrum is reproduced by a power law of photon index 3.64 {+-} 0.39{sub stat} {+-} 0.25{sub sys}. Within errors, this is compatible with the one derived by VERITAS in 2009. From the spectra corrected for absorption by the extragalactic background light, we only find small differences between the four models that we applied, and constrain the redshift of the blazar to z < 0.68.

79 ASTRONOMY AND ASTROPHYSICS↗

A RECOLLIMATION SHOCK 80 mas FROM THE CORE IN THE JET OF THE RADIO GALAXY 3C 120: OBSERVATIONAL EVIDENCE AND MODELING

We present Very Long Baseline Array observations of the radio galaxy 3C 120 at 5, 8, 12, and 15 GHz designed to study a peculiar stationary jet feature (hereafter C80) located {approx}80 mas from the core, which was previously shown to display a brightness temperature {approx}600 times larger than expected at such distances. The high sensitivity of the images-obtained between 2009 December and 2010 June-has revealed that C80 corresponds to the eastern flux density peak of an arc of emission (hereafter A80), downstream of which extends a large ({approx}20 mas in size) bubble-like structure that resembles an inverted bow shock. The linearly polarized emission closely follows that of the total intensity in A80, with the electric vector position angle distributed nearly perpendicular to the arc-shaped structure. Despite the stationary nature of C80/A80, superluminal components with speeds up to 3 {+-} 1 c have been detected downstream from its position, resembling the behavior observed in the HST-1 emission complex in M87. The total and polarized emission of the C80/A80 structure, its lack of motion, and brightness temperature excess are best reproduced by a model based on synchrotron emission from a conical shock with cone opening angle {eta} = 10 Degree-Sign , jet viewing angle {theta} = 16 Degree-Sign , a completely tangled upstream magnetic field, and upstream Lorentz factor {gamma}{sub u} = 8.4. The good agreement between our observations and numerical modeling leads us to conclude that the peculiar feature associated with C80/A80 corresponds to a conical recollimation shock in the jet of 3C 120 located at a de-projected distance of {approx}190 pc downstream from the nucleus.

79 ASTRONOMY AND ASTROPHYSICS↗

PHOTOSPHERIC FLUX CANCELLATION AND THE BUILD-UP OF SIGMOIDAL FLUX ROPES ON THE SUN

In this study we explore the scenario of photospheric flux cancellation being the primary formation mechanism of sigmoidal flux ropes in decaying active regions. We analyze magnetogram and X-ray observations together with data-driven non-linear force-free field (NLFFF) models of observed sigmoidal regions to test this idea. We measure the total and canceled fluxes in the regions from MDI magnetograms, as well as the axial and poloidal flux content of the modeled NLFFF flux ropes for three sigmoids-2007 February, 2007 December, and 2010 February. We infer that the sum of the poloidal and axial flux in the flux ropes for most models amounts to about 60%-70% of the canceled flux and 30%-50% of the total flux in the regions. The flux measurements and the analysis of the magnetic field structure show that the sigmoids first develop a strong axial field manifested as a sheared arcade and then, as flux cancellation proceeds, form long S-shaped field lines that contribute to the poloidal flux. In addition, the dips in the S-shaped field lines are located at the sites of flux cancellation that have been identified from the MDI magnetograms. We find that the line-of-sight-integrated free energy is also concentrated at these locations for all three regions, which can be liberated in the process of eruption. Flare-associated brightenings and flare loops coincide with the location of the X-line topology that develops at the site of most vigorous flux cancellation.

79 ASTRONOMY AND ASTROPHYSICS↗