SU-G-BRB-15: Verifications of Absolute and Relative Dosimetry of a Novel Stereotactic Breast Device: GammaPodTM

Purpose: A dedicated stereotactic breast radiotherapy device, GammaPod, was developed to treat early stage breast cancer. The first clinical unit was installed and commissioned at University of Maryland. We report our methodology of absolute dosimetry in multiple calibration conditions and dosimetric verifications of treatment plans produced by the system. Methods: GammaPod unit is comprised of a rotating hemi-spherical source carrier containing 36 Co-60 sources and a concentric tungsten collimator providing beams of 15 and 25 mm. Absolute dose calibration formalism was developed with modifications to AAPM protocols for unique geometry and different calibration medium (acrylic, polyethylene or liquid water). Breast cup-size specific and collimator output factors were measured and verified with respect to Monte-Carlo simulations for single isocenter plans. Multiple isocenter plans were generated for various target size, location and cup-sizes in phantoms and 20 breast cancer patients images. Stereotactic mini-farmer chamber, OSL and TLD detectors as well as radio-chromic films were used for dosimetric measurements. Results: At the time of calibration (1/14/2016), absolute dose rate of the GammaPod was established to be 2.10 Gy/min in acrylic for 25 mm for sources installed in March 2011. Output factor for 15 mm collimator was measured to be 0.950. Absolute dose calibration was independently verified by IROC-Houston with a TLD/Institution ratio of 0.99. Cup size specific output measurements in liquid water for single isocenter were found to be within 3.0% of MC simulations. Point-dose measurements of multiple isocenter treatment plans were found to be within −1.0 ± 1.2 % of treatment planning system while 2-dimensional gamma analysis yielded a pass rate of 97.9 ± 2.2 % using gamma criteria of 3% and 2mm. Conclusion: The first GammaPod treatment unit for breast stereotactic radiotherapy was successfully installed, calibrated and commissioned for patient treatments. An absolute dosimetry and dosimetric verification protocols were successfully created.

60 APPLIED LIFE SCIENCES↗

SU-G-TeP2-06: Development of Novel Radiochromic Films for Radiotherapy Dosimetry

Purpose: To develop and evaluate novel radiochromic films for quality assurance in radiotherapy dosimetry. Materials and Methods: Novel radiochromic film compositions were formulated using leuco crystal violet (LCV) as a reporting system and tetrabromoethane as a free radical source. The film matrix used consisted of polyurethane polymer mixed with dibutyl phthalate plasticizer (20 wt%). The concentration of the radical initiator was kept constant at 10 wt% and the concentration of the LCV dye varied (1 and 2 wt%). To ensure uniform thickness of the film, its precursors were sandwiched between two pieces of glass separated by a 1 mm gap between during the curing process. The films were cut into pieces and were irradiated with a 6 MV X-ray beam to selected doses. The change in optical density was measured using a flatbed scanner and a spectrophotometer. Results: The results showed that all film formulations exhibited a linear response with dose and an absorption maximum at ∼ 590 nm. The formulation with 2 wt% LCV was ∼ 30% more sensitive to dose than the formulation with 1 wt% LCV. Both films were very deformable. In addition, the radiochromic response of the film was found to bleach over a short period of time (few weeks) allowing the film to be reused for dose verification measurements. Conclusion: Both film formulations displayed excellent sensitivity and linearity to radiation dose and thus can be used for the 2D dosimetry of clinical megavoltage and kilovoltage X-ray beams. In addition, the thickness of the film could easily be increased allowing for their potential use as a deformable bolus material. However, thicker films would need more optimization of the manufacturing procedure to ensure consistent material uniformity and sensitivity are recommended.

60 APPLIED LIFE SCIENCES↗

SU-G-TeP3-08: Pre-Clinical Radionuclide Therapy Dosimetry in Several Pediatric Cancer Xenografts

Purpose: The focus of this work is to perform Monte Carlo-based dosimetry for several pediatric cancer xenografts in mice treated with a novel radiopharmaceutical {sup 131}I-CLR1404. Methods: Four mice for each tumor cell line were injected with 8–13 µCi/g of the {sup 124}124I-CLR1404. PET/CT images of each individual mouse were acquired at 5–6 time points over the span of 96–170 hours post-injection. Following acquisition, the images were co-registered, resampled, rescaled, corrected for partial volume effects (PVE), and masked. For this work the pre-treatment PET images of {sup 124}I-CLR1404 were used to predict therapeutic doses from {sup 131}I-CLR1404 at each time point by assuming the same injection activity and accounting for the difference in physical decay rates. Tumors and normal tissues were manually contoured using anatomical and functional images. The CT and the PET images were used in the Geant4 (v9.6) Monte Carlo simulation to define the geometry and source distribution, respectively. The total cumulated absorbed dose was calculated by numerically integrating the dose-rate at each time point over all time on a voxel-by-voxel basis. Results: Spatial distributions of the absorbed dose rates and dose volume histograms as well as mean, minimum, maximum, and total dose values for each ROI were generated for each time point. Conclusion: This work demonstrates how mouse-specific MC-based dosimetry could potentially provide more accurate characterization of efficacy of novel radiopharmaceuticals in radionuclide therapy. This work is partially funded by NIH grant CA198392.

60 APPLIED LIFE SCIENCES↗

TU-H-CAMPUS-TeP2-03: High Sensitivity and High Resolution Fiber Based Micro-Detector for Sub-Millimeter Preclinical Dosimetry

Purpose: Current precision of small animal and cell micro-irradiators has continuously increased during the past years. Currently, preclinical irradiators can deliver sub-millimeter fields with micrometric precision but there are no water equivalent dosimeters to determine small field profiles and dose in the orthovoltage range of energies with micrometric resolution and precision. We have developed a fiber based micro-dosimeter with the resolution and dosimetric accuracy required for radiobiological research. Methods: We constructed two prototypes of micro-dosimeters based on different compositions of fiber scintillators to study the spatial resolution and dosimetric precision of small animal and cell micro-irradiators. The first has green output and the second has blue output. The blue output dosimeter has the highest sensitivity because it matches the spectral sensitivity of silicon photomultipliers. A blue detector with 500um cross section was built and tested respect to a CC01 ion chamber, film, and the 1500um green output detector. Orthovoltage fields from 1×1mm2 to 5×5mm2 were used for detector characteristics comparison. Results: The blue fiber dosimeter shows great agreement with films and matches dose measurements with the gold-standard ion chamber for 5×5mm2 fields. The detector has the appropriate sensitivity to measure fields from 1×1mm2 to larger sizes with a 1% dosimetric accuracy. The spatial resolution is in the sub-millimeter range and the spectral matching with the photomultiplier allows reducing the sensor cross section even further than the presented prototype. These results suggest that scintillating fibers combined with silicon photomultipliers is the appropriate technology to pursue micro-dosimetry for small animals and disperse cell samples. Conclusion: The constructed detectors establish a new landmark for the resolution and sensitivity of fiber based microdetectors. The validation of the detector in our small animal and cell irradiator shows that they are appropriate for preclinical and micro single cell irradiation quality assurance and dosimetry.

60 APPLIED LIFE SCIENCES↗

TH-CD-201-05: Characterization of a Novel Light-Collimating Tank Optical-CT System for 3D Dosimetry

Purpose: Comprehensive 3D dosimetry is highly desirable for advanced clinical QA, but costly optical readout techniques have hindered widespread implementation. Here, we present the first results from a cost-effective Integrated-lens Dry-tank Optical Scanner (IDOS), designed for convenient 3D dosimetry readout of radiochromic plastic dosimeters (e.g. PRESAGE). Methods: The scanner incorporates a novel transparent light-collimating tank, which collimates a point light source into parallel-ray CT geometry. The tank was designed using an in-house Monte-Carlo optical ray-tracing simulation, and was cast in polyurethane using a 3D printed mould. IDOS spatial accuracy was evaluated by imaging a set of custom optical phantoms, with comparison to x-ray CT images. IDOS dose measurement performance was assessed by imaging PRESAGE dosimeters irradiated with simple known dose distributions (e.g., 4 field box 6MV treatment with Varian Linac). Direct comparisons were made to images from our gold standard DLOS scanner and calculated dose distributions from a commissioned Eclipse planning system. Results: All optical CT images were reconstructed at 1mm isotropic resolution. Comparison of IDOS and x-ray CT images of the geometric phantom demonstrated excellent IDOS geometric accuracy (sub-mm) throughout the dosimeter. IDOS measured 3D dose distribution agreed well with prediction from Eclipse, with 95% gamma pass rate at 3%/3mm. Cross-scanner dose measurement gamma analysis shows >90% of pixels passing at 3%/3mm. Conclusion: The first prototype of the IDOS system has demonstrated promising performance, with accurate dosimeter readout and negligible spatial distortion. The use of optical simulations and 3D printing to create a light collimating-tank has dramatically increased convenience and reduced costs by removing the need for expensive lenses and large volumes of refractive matching fluids.

60 APPLIED LIFE SCIENCES↗

Improved accuracy of S-value-based dosimetry: a guide to transition from Cristy–Eckerman to ICRP adult phantoms

Background: In 2016, the International Commission on Radiological Protection (ICRP) published the results of Monte Carlo simulations performed using updated and anatomically realistic voxelized phantoms. The resulting specific absorbed fractions are based on more realistic human anatomy than those computed in the stylized, geometrical Cristy–Eckerman (CE) phantom. Despite this development, the ICRP-absorbed fractions have not been widely adopted for radiopharmaceutical dosimetry. To help make the transition, we have established a correspondence between source and target tissues defined in the CE phantom and those defined in the ICRP phantoms. Results: The ICRP phantom has 79 source regions and 43 target regions in comparison with the 23 source and 18 target tissue regions defined in the CE phantom. The ICRP phantom provides tissue regions with greater anatomical detail. Some of this additional detail is focused on radiation protection and dosimetry of inhaled/ingested radioactivity. Some, but not all, of this detail is useful and appropriate for radiopharmaceutical therapy. We have established the correspondence between CE and ICRP phantom source and target regions and attempted to highlight the ICRP source tissues relevant to radiopharmaceutical therapy (RPT). This paper provides tables and figures highlighting the correspondences established. Conclusion: The results provide assistance in transitioning from CE-stylized phantoms to the anatomically accurate voxelized ICRP phantoms. It provides specific guidance for porting the total absorbed activity for regions as defined in the CE phantom to regions within the ICRP phantoms.

61 RADIATION PROTECTION AND DOSIMETRY↗

Godiva-IV Dosimetry Exercise 2022 (IER-538 CED4A Report)

This report presents the final results of IER 538, The International Nuclear Accident Dosimeter (NAD) Intercomparison Exercise with Godiva-IV. The purpose of the exercise, held in August of 2022, was to test participants’ NADs and dosimetry personnel to the dose estimation requirements established by ANSI/HPS-N13.3 Dosimetry for Criticality Accidents and DOE-STD-1098-2017, Radiological Control. Two prompt critical bursts of the Godiva critical assembly were used to simulate criticality accidents, and NADs from participating laboratories were placed at known locations around Godiva, mounted on either BOttle Manikin ABsorptions (BOMABs) phantoms (to simulate doses received by people) or plates (to simulate doses in free air). Similar exercises have been held in 2016 and 2018 using National Criticality Experiments Research Center’s (NCERC’s) Flattop and Godiva assemblies.

61 RADIATION PROTECTION AND DOSIMETRY↗

Logistics for the 2026 International Nuclear Accident Dosimetry Intercomparison Exercise

The purpose of this exercise is to test participants’ nuclear accident dosimeters (NADs) and personnel to the requirements established by American National Standards Institute (ANSI), Health Physics Society (HPS) standard ANSI/HPS-N13.3-2013 (R2025) Dosimetry for Criticality Accidents. IER-634 is the second nuclear accident dosimetry exercise taking place at the Armed Forces Radiobiology Research Institute (AFRRI) in Bethesda, MD, a Department of Defense (DOD) facility. This effort continues use of the high-dose neutron exposure test bed maintained by the DOD and represents the continued collaboration between the DOD and Department of Energy (DOE). Previous work at AFRRI included a reactor characterization (IER 484) in 2023 and a nuclear accident intercomparison exercise (IER-602) in 2024.

61 RADIATION PROTECTION AND DOSIMETRY↗

Development of a series of Korean pediatric and adult head computational phantoms and application to nuclear medicine dosimetry - Paper 26

Over the past decades, advances in Single Photon Emission Computed Tomography (SPECT) and Positron Emission Tomography (PET) imaging techniques and an increasing number of new radiopharmaceuticals have resulted in a surge of neuroimaging applications in nuclear medicine on pediatric and adult patients. It is not feasible to directly measure the absorbed dose to the organs of the human body from nuclear medicine procedures. The formalism of the Medical Internal Radiation Dose (MIRD) committee of the Society of Nuclear Medicine has been adopted as the calculation method to estimate radiation dose to target organs from radionuclides distributed in source organs. The absorbed dose to a target organ from different types of radionuclides distributed within source organs can be estimated by the products of the time-integrated activity in each source region and organ dose conversion coefficients, called S values (Gy/MBq-s). S values are computed from a comprehensive set of Specific Absorbed Fraction (SAF), which are calculated from computational human phantoms with realistic anatomical structures coupled with Monte Carlo transport technique. The current SAF data for pediatric and adult head and brain dosimetry is based on a series of stylized computational phantoms. However, dosimetric errors caused by the unrealistic anatomy of stylized phantoms in internal dosimetry calculations have been reported by several studies. In the current study, we developed a series of realistic computational head phantoms representing 6, 9, 12, 15, and 22-year-old standard Korean males, and computed a comprehensive set of SAFs using the phantoms coupled with Monte Carlo transport technique. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Radiation Protection and Dosimetry in Medicine - An Overview - Paper 82

In recent years, radiological protection, radiation safety and dosimetry issues have emerged concerning the medical applications of ionizing radiation. Amongst several other issues, the dissemination of the use of Computer Tomography (CT), including for paediatric exams and the growing number of interventional radiology and interventional cardiology procedures have contributed to raise the concerns about the need to more fully justify the medical practices using ionizing radiation and to optimize the protection, reducing the dose to the patients and to the medical staff in the medical applications of ionizing radiation. The importance of implementing the principle of justification in the medical exposures and to further progress in the implementation of the principle of optimization of the protection is of paramount importance for the establishment of a robust international system of radiological protection. The consideration of radiosensitivity issues became mandatory in order to address different issues such as the paediatric CT exposures and the risk of secondary cancer induction in patients years or decades after radiation treatments. Low-dose radiation research also gained a renewed interest in order to overcome longstanding unresolved issues concerning namely the relationship between the radiological risk versus dose in the low dose region characteristic of the medical radiodiagnostic procedures and to shed some light in the mechanisms associated to the biological effects induced by ionizing radiation. Last but not least, the safety of radiotherapy treatments has also driven considerable efforts from the international community of experts, with the aim of reducing the number of incidents and accidents leading to the overexposure of patients to ionizing radiation. In this paper, an overview of the aforementioned topics is provided, considering the international Basic Safety Standards, European Union Directives and national regulations. Views and policies from international organizations such as the IAEA, the WHO and studies and reports from institutions such as the UNSCEAR, ICRP and the NCRP will be conveyed. Recent or ongoing epidemiological studies will be mentioned. Radiological protection and dosimetry of the patient and the workers in the medical applications of ionizing radiation will be discussed. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Luminescence dosimetry for evaluation of the external exposure in Metlino, upper Techa River valley, Southern Urals, Russia: Analysis of new results

Luminescence dosimetry was applied in the former settlement of Metlino, Southern Urals, Russia as part of a full-scale study to validate the Techa River Dosimetry System (TRDS) 2016 for the upper Techa River region. The village, which was evacuated in 1956, was located 7 km downstream of the release point of liquid radioactive waste by the Mayak plutonium facility. Several brick samples were taken from north-eastern and south-eastern walls of the granary, facing the former Techa river shoreline and floodplain. Samples were all taken at the same height and measured at different depths into the brick. For the majority of brick samples, good Optically Stimulated Luminescence properties of the quartz grains were observed. In some cases, however, strong levels of sensitization and/or signal recuperation were encountered which necessitated adjustment in the measurement protocols. Anthropogenic doses in bricks varied from 1.5 to 6.6 Gy and the horizontal profiles along both walls showed significant variation, which is explained on a qualitative basis. Further, a dose depth profile is observed for selected samples, which is different from the dose depth profile measured and simulated for samples from the north-western wall of the granary in previous studies. This is qualitatively explained by the differences in source configuration.

61 RADIATION PROTECTION AND DOSIMETRY↗

Prenatal exposure estimation of BPA and DEHP using integrated external and internal dosimetry: A case study

Prenatal exposure to Endocrine disruptors (EDs), such as Bisphenol A (BPA) and di (2-ethylhexyl) phthalate (DEHP), has been associated with obesity and diabetes diseases in childhood, as well as reproductive, behavioral and neurodevelopment problems. The aim of this study was to estimate the prenatal exposure to BPA and DEHP through food consumption for pregnant women living in Tarragona County (Spain). Probabilistic calculations of prenatal exposure were estimated by integrated external and internal dosimetry modelling, physiologically based pharmacokinetic (PBPK) model, using a Monte-Carlo simulation. Physical characteristic data from the cohort, along with food intake information from the questionnaires (concentrations of BPA and DEHP in different food categories and the range of the different food ratios), were used to estimate the value of the total dietary intake for the Tarragona pregnancy cohort. The major contributors to the total dietary intake of BPA were canned fruits and vegetables, followed by canned meat and meat products. In turn, milk and dairy products, followed by ready to eat food (including canned dinners), were the most important contributors to the total dietary intake of DEHP. Despite the dietary variations among the participants, the intakes of both chemicals were considerably lower than their respective current tolerable daily intake (TDI) values established by the European Food Safety Authority (EFSA). Internal dosimetry estimates suggest that the plasma concentrations of free BPA and the most important DEHP metabolite, mono (2-ethylhexyl) phthalate (MEHP), in pregnant women were characterized by transient peaks (associated with meals) and short half-lives (< 2 h). In contrast, fetal exposure was characterized by a low and sustained basal BPA and MEHP concentration due to a lack of metabolic activity in the fetus. Therefore, EDs may have a greater effect on developing organs in young children or in the unborn child. - Highlights: • Prenatal exposure to EDs using total diet study for the Tarragona cohort presented. • Contribution of food categories to the total dietary intake of BPA and DEHP investigated. • Application of PBPK models to predict the fetus’ toxicokinetic profiles. • Free BPA and MEHP plasma concentrations in women characterized by transient peaks. • Fetus shows high sustained basal concentration of BPA and DEHP due to low or no metabolic activity.

54 ENVIRONMENTAL SCIENCES↗

Pre- and post-treatment image-based dosimetry in 90 Y-microsphere radioembolization using the TOPAS Monte Carlo toolkit

Objective.To evaluate the pre-treatment and post-treatment imaging-based dosimetry of patients treated with 90Y-microspheres, including accurate estimations of dose to tumor, healthy liver and lung. To do so, the Monte Carlo (MC) TOPAS platform is in this work extended towards its utilization in radionuclide therapy. Approach. In this study, five patients treated at the Massachusetts General Hospital were selected for this study. All patients had data for both pre-treatment SPECT-CT imaging using 99mTc-MAA as a surrogate of the 90Y-microspheres treatment and SPECT-CT imaging immediately after the 90Y activity administration. Pre- and post-treatment doses were computed with TOPAS using the SPECT images to localize the source positions and the CT images to account for tissue inhomoegeneities. We compared our results with analytical calculations following the voxel-based MIRD scheme. Main results. TOPAS results largely agreed with the MIRD-based calculations in soft tissue regions: the average difference in mean dose to the liver was 0.14 Gy GBq -1 (2.6%). However, dose distributions in the lung differed considerably: absolute differences in mean doses to the lung ranged from 1.2 to 6.3 Gy GBq -1 and relative differences from 153% to 231%. We also found large differences in the intra-hepatic dose distributions between pre- and post-treatment imaging, but only limited differences in the pulmonary dose. Significance. Doses to lung were found to be higher using TOPAS with respect to analytical calculations which may significantly underestimate dose to the lung, suggesting the use of MC methods for 90Y dosimetry. According to our results, pre-treatment imaging may still be representative of dose to lung in these treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A mixture parameterized biologically based dosimetry model to predict body burdens of polycyclic aromatic hydrocarbons in developmental zebrafish toxicity assays

Polycyclic aromatic hydrocarbons (PAHs) are a group of environmental toxicants found ubiquitously as complex mixtures in human-impacted environments. Developmental zebrafish exposures have been used widely to study PAH toxicity, but most studies report nominal exposure concentrations. Nominal exposure concentrations can be unreliable dose metrics due to differences in toxicant bioavailability resulting from disparate exposure methodologies and chemical properties. Toxicokinetic modeling can predict toxicant tissue doses to facilitate comparison between exposures of different chemicals, methodologies, and biological models. We parameterize a biologically based dosimetry model for developmental zebrafish toxicity assays for 9 PAHs. The model was optimized with measurements from media, tissue, and plastic plate walls throughout a static developmental exposure to a mixture of 10 PAHs of high abundance within the Portland Harbor Superfund Site. Plate binding, volatilization, zebrafish permeability, and tissue—media partitioning coefficients vary widely between PAHs. Model predictions accounted for 83% and 54% of 48 hpf body burdens within a factor of 2 resulting from exposures to mixtures and individual PAHs, respectively. Accounting for solubility significantly improves model performance. Competition for active sites in metabolizing enzymes may change biotransformation kinetics between individual PAH and mixture exposures. Area under the curve estimations of concentrations in zebrafish resulted in altered hazard rankings from nominal exposure concentrations. Future work will be oriented to generalizing the model to other PAHs. This PAH dosimetry model improves the interpretability of developmental zebrafish toxicity assays by providing time-resolved body burdens from nominal exposure concentrations.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Development and characterization of a three-dimensional radiochromic film stack dosimeter for megavoltage photon beam dosimetry

Purpose: Three-dimensional (3D) dosimeters are particularly useful for verifying the commissioning of treatment planning and delivery systems, especially with the ever-increasing implementation of complex and conformal radiotherapy techniques such as volumetric modulated arc therapy. However, currently available 3D dosimeters require extensive experience to prepare and analyze, and are subject to large measurement uncertainties. This work aims to provide a more readily implementable 3D dosimeter with the development and characterization of a radiochromic film stack dosimeter for megavoltage photon beam dosimetry. Methods: A film stack dosimeter was developed using Gafchromic{sup ®} EBT2 films. The dosimeter consists of 22 films separated by 1 mm-thick spacers. A Virtual Water™ phantom was created that maintains the radial film alignment within a maximum uncertainty of 0.3 mm. The film stack dosimeter was characterized using simulations and measurements of 6 MV fields. The absorbed-dose energy dependence and orientation dependence of the film stack dosimeter were investigated using Monte Carlo simulations. The water equivalence of the dosimeter was determined by comparing percentage-depth-dose (PDD) profiles measured with the film stack dosimeter and simulated using Monte Carlo methods. Film stack dosimeter measurements were verified with thermoluminescent dosimeter (TLD) microcube measurements. The film stack dosimeter was also used to verify the delivery of an intensity-modulated radiation therapy (IMRT) procedure. Results: The absorbed-dose energy response of EBT2 film differs less than 1.5% between the calibration and film stack dosimeter geometries for a 6 MV spectrum. Over a series of beam angles ranging from normal incidence to parallel incidence, the overall variation in the response of the film stack dosimeter is within a range of 2.5%. Relative to the response to a normally incident beam, the film stack dosimeter exhibits a 1% under-response when the beam axis is parallel to the film planes. Measured and simulated PDD profiles agree within a root-mean-square difference of 1.3%. In-field film stack dosimeter and TLD measurements agree within 5%, and measurements in the field penumbra agree within 0.5 mm. Film stack dosimeter and TLD measurements have expanded (k = 2) overall measurement uncertainties of 6.2% and 5.8%, respectively. Film stack dosimeter measurements of an IMRT dose distribution have 98% agreement with the treatment planning system dose calculation, using gamma criteria of 3% and 2 mm. Conclusions: The film stack dosimeter is capable of high-resolution, low-uncertainty 3D dose measurements, and can be readily incorporated into an existing film dosimetry program.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-235: Varian Portal Dosimetry Accuracy at Detecting Simulated Delivery Errors

Purpose: To use receiver operating characteristic (ROC) analysis to quantify the Varian Portal Dosimetry (VPD) application's ability to detect delivery errors in IMRT fields. Methods: EPID and VPD were calibrated/commissioned using vendor-recommended procedures. Five clinical plans comprising 56 modulated fields were analyzed using VPD. Treatment sites were: pelvis, prostate, brain, orbit, and base of tongue. Delivery was on a Varian Trilogy linear accelerator at 6MV using a Millenium120 multi-leaf collimator. Image pairs (VPD-predicted and measured) were exported in dicom format. Each detection test imported an image pair into Matlab, optionally inserted a simulated error (rectangular region with intensity raised or lowered) into the measured image, performed 3%/3mm gamma analysis, and saved the gamma distribution. For a given error, 56 negative tests (without error) were performed, one per 56 image pairs. Also, 560 positive tests (with error) with randomly selected image pairs and randomly selected in-field error location. Images were classified as errored (or error-free) if percent pixels with γ<κ was < (or ≥) τ. (Conventionally, κ=1 and τ=90%.) A ROC curve was generated from the 616 tests by varying τ. For a range of κ and τ, true/false positive/negative rates were calculated. This procedure was repeated for inserted errors of different sizes. VPD was considered to reliably detect an error if images were correctly classified as errored or error-free at least 95% of the time, for some κ+τ combination. Results: 20mm{sup 2} errors with intensity altered by ≥20% could be reliably detected, as could 10mm{sup 2} errors with intensity was altered by ≥50%. Errors with smaller size or intensity change could not be reliably detected. Conclusion: Varian Portal Dosimetry using 3%/3mm gamma analysis is capable of reliably detecting only those fluence errors that exceed the stated sizes. Images containing smaller errors can pass mathematical analysis, though may be detected by visual inspection. This work was not funded by Varian Oncology Systems. Some authors have other work partly funded by Varian Oncology Systems.

60 APPLIED LIFE SCIENCES↗

SU-E-T-05: A 2D EPID Transit Dosimetry Model Based On An Empirical Quadratic Formalism

Purpose: To describe a 2D electronic portal imaging device (EPID) transit dosimetry model, based on an empirical quadratic formalism, that can predict either EPID or in-phantom dose distribution for comparisons with EPID captured image or treatment planning system (TPS) dose respectively. Methods: A quadratic equation can be used to relate the reduction in intensity of an exit beam to the equivalent path length of the attenuator. The calibration involved deriving coefficients from a set of dose planes measured for homogeneous phantoms with known thicknesses under reference conditions. In this study, calibration dose planes were measured with EPID and ionisation chamber (IC) in water for the same reference beam (6MV, 100mu, 20×20cm{sup 2}) and set of thicknesses (0–30cm). Since the same calibration conditions were used, the EPID and IC measurements can be related through the quadratic equation. Consequently, EPID transit dose can be predicted from TPS exported dose planes and in-phantom dose can be predicted using EPID distribution captured during treatment as an input. The model was tested with 4 open fields, 6 wedge fields, and 7 IMRT fields on homogeneous and heterogeneous phantoms. Comparisons were done using 2D absolute gamma (3%/3mm) and results were validated against measurements with a commercial 2D array device. Results: The gamma pass rates for comparisons between EPID measured and predicted ranged from 93.6% to 100.0% for all fields and phantoms tested. Results from this study agreed with 2D array measurements to within 3.1%. Meanwhile, comparisons in-phantom between TPS computed and predicted ranged from 91.6% to 100.0%. Validation with 2D array device was not possible for inphantom comparisons. Conclusion: A 2D EPID transit dosimetry model for treatment verification was described and proven to be accurate. The model has the advantage of being generic and allows comparisons at the EPID plane as well as multiple planes in-phantom.

60 APPLIED LIFE SCIENCES↗

SU-E-T-104: Development of 3 Dimensional Dosimetry System for Gamma Knife

Purpose: The aim of this study was to develop a new 3 dimensional dosimetry system to verify the dosimetric accuracy of Leksell Gamma Knife-Perfexion™ (LGK) (Elekta, Norcross, GA). Methods: We designed and manufactured a lightweight dosimetry instrument to be equipped with the head frame to LGK. It consists of a head phantom, a scintillator, a CCD camera and a step motor. The 10×10 cm2 sheet of Gd2O3;Tb phosphor or Gafchromic EBT3 film was located at the center of the 16 cm diameter hemispherical PMMA, the head phantom. The additional backscatter compensating material of 1 cm thick PMMA plate was placed downstream of the phosphor sheet. The backscatter plate was transparent for scintillation lights to reach the CCD camera with 1200×1200 pixels by 5.2 um pitch. With This equipment, 300 images with 0.2 mm of slice gap were acquired under three collimator setups (4mm, 8mm and 16mm), respectively. The 2D projected doses from 3D distributions were compared with the exposured film dose. Results: As all doses normalized by the maximum dose value in 16 mm setup, the relative differences between the equipment dose and film dose were 0.2% for 4mm collimator and 0.5% for 8mm. The acquisition of 300 images by the equipment took less than 3 minutes. Conclusion: The new equipment was verified to be a good substitute to radiochromic film, with which required more time and resources. Especially, the new methods was considered to provide much convenient and faster solution in the 3D dose acquisition for LGK.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗