Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DOSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Location Modification Factors for Potential Dose Estimation

A Department of Energy facility must comply with the National Emission Standard for Hazardous Air Pollutants for radioactive air emissions. The standard is an effective dose of less than 0.1 mSv yr-1 to the maximum public receptor. Additionally, a lower dose level may be assigned to a specific emission point in a State issued permit. A method to efficiently estimate the expected dose for future emissions is described. This method is most appropriately applied to a research facility with several emission points with generally low emission levels of numerous isotopes.

Radiation, radionuclide NESHAPs, Dose, 40CFR61 Sub↗

Biological equivalent dose studies for dose escalation in the stereotactic synchrotron radiation therapy clinical trials

Synchrotron radiation is an innovative tool for the treatment of brain tumors. In the stereotactic synchrotron radiation therapy (SSRT) technique a radiation dose enhancement specific to the tumor is obtained. The tumor is loaded with a high atomic number (Z) element and it is irradiated in stereotactic conditions from several entrance angles. The aim of this work was to assess dosimetric properties of the SSRT for preparing clinical trials at the European Synchrotron Radiation Facility (ESRF). To estimate the possible risks, the doses received by the tumor and healthy tissues in the future clinical conditions have been calculated by using Monte Carlo simulations (PENELOPE code). The dose enhancement factors have been determined for different iodine concentrations in the tumor, several tumor positions, tumor sizes, and different beam sizes. A scheme for the dose escalation in the various phases of the clinical trials has been proposed. The biological equivalent doses and the normalized total doses received by the skull have been calculated in order to assure that the tolerance values are not reached.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dose convolution filter: Incorporating spatial dose information into tissue response modeling

Purpose: A model is introduced to integrate biological factors such as cell migration and bystander effects into physical dose distributions, and to incorporate spatial dose information in plan analysis and optimization. Methods: The model consists of a dose convolution filter (DCF) with single parameter {sigma}. Tissue response is calculated by an existing NTCP model with DCF-applied dose distribution as input. The authors determined {sigma} of rat spinal cord from published data. The authors also simulated the GRID technique, in which an open field is collimated into many pencil beams. Results: After applying the DCF, the NTCP model successfully fits the rat spinal cord data with a predicted value of {sigma}=2.6{+-}0.5 mm, consistent with 2 mm migration distances of remyelinating cells. Moreover, it enables the appropriate prediction of a high relative seriality for spinal cord. The model also predicts the sparing of normal tissues by the GRID technique when the size of each pencil beam becomes comparable to {sigma}. Conclusions: The DCF model incorporates spatial dose information and offers an improved way to estimate tissue response from complex radiotherapy dose distributions. It does not alter the prediction of tissue response in large homogenous fields, but successfully predicts increased tissue tolerance in small or highly nonuniform fields.

61 RADIATION PROTECTION AND DOSIMETRY↗

Necrosis and Apoptosis in Hepatocellular Carcinoma Following Low-Dose Versus High-Dose Preoperative Chemoembolization

Our purpose was to study necrosis and apoptosis of hepatocellular carcinoma (HCC) cells after preoperative transcatheter arterial chemoembolization (TACE) with use of low-dose and high-dose anticancer drugs in HCCs. Fifty-four patients with advanced but surgically resectable HCC were studied. Thirty-four patients who elected to undergo preoperative superselective TACE were randomized to low- and high-dose TACE. Patients in group A (n = 16) received low-dose anticancer drugs: 2 mg mitomycin C (MMC), 10 mg epirubicin (EPI), and 100 mg carboplatin (CBP). Patients in group B (n = 18) were given high doses of anticancer drugs (10 mg MMC, 40 mg EPI, and 300 mg CBP). Hepatic resection was subsequently performed. Group C comprised 20 patients who underwent resection without TACE. In all patients the necrosis rates and apoptosis index of tumor cells were evaluated by pathologic examinations and terminal deoxynucleotidyl transferase-mediated nick-end labeling assay. There was no significant difference between group A and group B in tumor response (p > 0.05) after TACE. Necrosis rates in groups A, B, and C were 88.4 {+-} 11.1%, 87.1 {+-} 12.5%, and 7.3 {+-} 3.5%, respectively. There was no significant difference between group A and group B (p > 0.05), while statistical difference was found between group A and group C (p < 0.001) and between group B and group C (p < 0.001). Apoptosis indexes in the three groups were 11.0 {+-} 4.0%, 10.7 {+-} 3.9%, and 5.6 {+-} 2.6%, respectively. Statistical difference exhibited between group A and group C (p < 0.001) and group B versus group C (p < 0.001). No significant difference was observed between group A and group B (p > 0.05). In conclusion, superselective TACE with low- and high-dose chemotherapeutic agents induced similar degrees of cellular apoptosis and necrosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation Dose and Risk Estimates of CT-Guided Percutaneous Liver Ablations and Factors Associated with Dose Reduction

PurposeTo determine the radiation dose associated with CT-guided percutaneous liver ablations and identify potential risk factors that result in higher radiation doses.Materials and MethodsBetween June 2011 and June 2015, 245 consecutive patients underwent 304 CT-guided liver ablation treatments. Patient demographics, tumor characteristics and procedural parameters were identified and analyzed. The peak skin dose and effective dose were assessed for each procedure. Excess relative risk related to radiation effects was calculated. A logistic regression model was prepared by means of stepwise logistic regression to identify variables predictive of increased radiation exposure.ResultsTumor ablations were performed with microwave (n = 220), radiofrequency (n = 74) or irreversible electroporation (IRE) (n = 10). The mean peak skin dose for ablations was 239.2 ± 136.4 mGy, and the mean effective dose was 36.6 ± 22.3 mSv. Of the patient and procedural parameters that were analyzed, increasing weight, use of intravenous contrast and/or hydrodissection during the procedure, together with treatment of multiple lesions in the same sitting were all associated with higher radiation exposure. The mean increase in the absolute risk of fatal malignancy from a single procedure was 0.18% (range 0.02–0.9%). No deterministic skin changes were identified in the patient cohort.ConclusionThe overall risk of stochastic and deterministic effects from radiation associated with CT-guided ablations is low compared with other inherent procedural complications. This study identifies several factors that are associated with higher radiation dose in percutaneous liver ablation procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose-Volume Parameters of the Corpora Cavernosa Do Not Correlate With Erectile Dysfunction After External Beam Radiotherapy for Prostate Cancer: Results From a Dose-Escalation Trial

Purpose: To analyze the correlation between dose-volume parameters of the corpora cavernosa and erectile dysfunction (ED) after external beam radiotherapy (EBRT) for prostate cancer. Methods and Materials: Between June 1997 and February 2003, a randomized dose-escalation trial comparing 68 Gy and 78 Gy was conducted. Patients at our institute were asked to participate in an additional part of the trial evaluating sexual function. After exclusion of patients with less than 2 years of follow-up, ED at baseline, or treatment with hormonal therapy, 96 patients were eligible. The proximal corpora cavernosa (crura), the superiormost 1-cm segment of the crura, and the penile bulb were contoured on the planning computed tomography scan and dose-volume parameters were calculated. Results: Two years after EBRT, 35 of the 96 patients had developed ED. No statistically significant correlations between ED 2 years after EBRT and dose-volume parameters of the crura, the superiormost 1-cm segment of the crura, or the penile bulb were found. The few patients using potency aids typically indicated to have ED. Conclusion: No correlation was found between ED after EBRT for prostate cancer and radiation dose to the crura or penile bulb. The present study is the largest study evaluating the correlation between ED and radiation dose to the corpora cavernosa after EBRT for prostate cancer. Until there is clear evidence that sparing the penile bulb or crura will reduce ED after EBRT, we advise to be careful in sparing these structures, especially when this involves reducing treatment margins.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Method of predicting the mean lung dose based on a patient's anatomy and dose-volume histograms

The aim of this study was to propose a method to predict the minimum achievable mean lung dose (MLD) and corresponding dosimetric parameters for organs-at-risk (OAR) based on individual patient anatomy. For each patient, the dose for 36 equidistant individual multileaf collimator shaped fields in the treatment planning system (TPS) was calculated. Based on these dose matrices, the MLD for each patient was predicted by the homemade DosePredictor software in which the solution of linear equations was implemented. The software prediction results were validated based on 3D conformal radiotherapy (3D-CRT) and volumetric modulated arc therapy (VMAT) plans previously prepared for 16 patients with stage III non–small-cell lung cancer (NSCLC). For each patient, dosimetric parameters derived from plans and the results calculated by DosePredictor were compared. The MLD, the maximum dose to the spinal cord (D{sub max} {sub cord}) and the mean esophageal dose (MED) were analyzed. There was a strong correlation between the MLD calculated by the DosePredictor and those obtained in treatment plans regardless of the technique used. The correlation coefficient was 0.96 for both 3D-CRT and VMAT techniques. In a similar manner, MED correlations of 0.98 and 0.96 were obtained for 3D-CRT and VMAT plans, respectively. The maximum dose to the spinal cord was not predicted very well. The correlation coefficient was 0.30 and 0.61 for 3D-CRT and VMAT, respectively. The presented method allows us to predict the minimum MLD and corresponding dosimetric parameters to OARs without the necessity of plan preparation. The method can serve as a guide during the treatment planning process, for example, as initial constraints in VMAT optimization. It allows the probability of lung pneumonitis to be predicted.

61 RADIATION PROTECTION AND DOSIMETRY↗

Gamma and Beta Absorbed Dose Conversion Coefficients in the Range from 10 keV to 10 MeV for Accidental Exposures From Point Sources Placed in Clothing in Proximity to the Body [Gamma and Beta Absorbed Dose Conversion Coefficients in the Range from 10 keV to 10 MeV for Accidental Exposures From Point Sources Placed in Clothing in Close Vicinity to the Body]

Here, retrospective dose assessment following acute radiation exposures during radiological incidents can be difficult and inaccurate due to the large uncertainties associated with dose estimation. However, rapid and accurate dose assessment is critical following an incident, such that appropriate treatment can be provided to the patient as early as possible. Incident Dose assessment relies heavily on biological dosimetry with corresponding large uncertainties for inhomogeneous exposures, resulting from the estimates of whole-body doses, while the assessment of absorbed doses to individual tissues might actually be more appropriate for acute radiation exposures.

61 RADIATION PROTECTION AND DOSIMETRY↗

Gold nanoparticle-aided brachytherapy with vascular dose painting: Estimation of dose enhancement to the tumor endothelial cell nucleus

Purpose: Theoretical microdosimetry at the subcellular level is employed in this study to estimate the dose enhancement to tumor endothelial cell nuclei, caused by radiation-induced photo/Auger electrons originating from gold nanoparticles (AuNPs) targeting the tumor endothelium, during brachytherapy. Methods: A tumor vascular endothelial cell (EC) is modeled as a slab of 2 {mu}m (thickness) x 10 {mu}m (length) x 10 {mu}m (width). The EC contains a nucleus of 5 {mu}m diameter and thickness of 0.5-1 {mu}m, corresponding to nucleus size 5%-10% of cellular volume, respectively. Analytic calculations based on the electron energy loss formula of Cole were carried out to estimate the dose enhancement to the nucleus caused by photo/Auger electrons from AuNPs attached to the exterior surface of the EC. The nucleus dose enhancement factor (nDEF), representing the ratio of the dose to the nucleus with and without the presence of gold nanoparticles was calculated for different AuNP local concentrations. The investigated concentration range considers the potential for significantly higher local concentration near the EC due to preferential accumulation of AuNP in the tumor vasculature. Four brachytherapy sources: I-125, Pd-103, Yb-169, and 50 kVp x-rays were investigated. Results: For nucleus size of 10% of the cellular volume and AuNP concentrations ranging from 7 to 140 mg/g, brachytherapy sources Pd-103, I-125, 50 kVp, and Yb-169 yielded nDEF values of 5.6-73, 4.8-58.3, 4.7-56.6, and 3.2-25.8, respectively. Meanwhile, for nucleus size 5% of the cellular volume in the same concentration range, Pd-103, I-125, 50 kVp, and Yb-169 yielded nDEF values of 6.9-79.2, 5.1-63.2, 5.0-61.5, and 3.3-28.3, respectively. Conclusions: The results predict that a substantial dose boost to the nucleus of endothelial cells can be achieved by applying tumor vasculature-targeted AuNPs in combination with brachytherapy. Such vascular dose boosts could induce tumor vascular shutdown, prompting extensive tumor cell death.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MO-E-17A-04: Size-Specific Dose Estimate (SSDE) Provides a Simple Method to Calculate Organ Dose for Pediatric CT Examinations

Purpose: Investigate the correlation of SSDE with organ dose in a pediatric population. Methods: Four anthropomorphic phantoms, representing a range of pediatric body habitus, were scanned with MOSFET dosimeters placed at 23 organ locations to determine absolute organ dosimetry. Phantom organ dosimetry was divided by phantom SSDE to determine correlation between organ dose and SSDE. Correlation factors were then multiplied by patient SSDE to estimate patient organ dose. Patient demographics consisted of 352 chest and 241 abdominopelvic CT examinations, 22 ± 15 kg (range 5−55 kg) mean weight, and 6 ± 5 years (range 4 mon to 23 years) mean age. Patient organ dose estimates were compared to published pediatric Monte Carlo study results. Results: Phantom effective diameters were matched with patient population effective diameters to within 4 cm. 23 organ correlation factors were determined in the chest and abdominopelvic region across nine pediatric weight subcategories. For organs fully covered by the scan volume, correlation in the chest (average 1.1; range 0.7−1.4) and abdominopelvic (average 0.9; range 0.7−1.3) was near unity. For organs that extended beyond the scan volume (i.e., skin, bone marrow, and bone surface), correlation was determined to be poor (average 0.3; range: 0.1−0.4) for both the chest and abdominopelvic regions, respectively. Pediatric organ dosimetry was compared to published values and was found to agree in the chest to better than an average of 5% (27.6/26.2) and in the abdominopelvic region to better than 2% (73.4/75.0). Conclusion: Average correlation of SSDE and organ dosimetry was found to be better than ± 10% for fully covered organs within the scan volume. This study provides a list of organ dose correlation factors for the chest and abdominopelvic regions, and describes a simple methodology to estimate individual pediatric patient organ dose based on patient SSDE.

60 APPLIED LIFE SCIENCES↗

SU-D-204-06: Dose and Image Quality Evaluation of a Low-Dose Slot-Scanning X-Ray System for Pediatric Orthopedic Studies

Purpose: Children in early teens with scoliosis require repeated radiographic exams over a number of years. The EOS (EOS imaging S.A., Paris, France) is a novel low-dose slot-scanning digital radiographic system designed to produce full-spine images of a free-standing patient. The radiation dose and image quality characteristics of the EOS were evaluated relative to those of a Computed Radiography (CR) system for scoliosis imaging. Methods: For dose evaluation, a full-torso anthropomorphic phantom was scanned five times using the default standard clinical protocols for both the EOS and a CR system, which include both posteroanterior and lateral full-spine views. Optically stimulated luminescent dosimeters (OSLDs), also known as nanoDots™ (Landauer, Inc., Glenwood, IL), were placed on the phantom’s surface to measure entrance skin dose. To assess image quality, MTF curves were generated from sampling the noise levels within the high-contrast regions of a line-pair phantom. Vertical and horizontal distortions were measured for the square line-pair phantom with the EOS system to evaluate the effects of geometric magnification and misalignment with the indicated imaging plane. Results: The entrance skin dose was measured to be 0.4 to 1.1 mGy for the EOS, and 0.7 to 3.6 mGy for the CR study. MTF comparison shows that CR greatly outperforms the EOS, despite both systems having a limiting resolution at 1.8 line-pairs per mm. Vertical distortion was unaffected by phantom positioning, because of the EOS slot-scanning geometry. Horizontal distortion increased linearly with miscentering distance. Conclusion: The EOS system resulted in approximately 70% lower radiation dose than CR for full-spine images. Image quality was found to be inferior to CR. Further investigation is required to see if EOS system is an acceptable modality for performing clinically diagnostic scoliosis examinations.

60 APPLIED LIFE SCIENCES↗

SU-E-I-32: Benchmarking Head CT Doses: A Pooled Vs. Protocol Specific Analysis of Radiation Doses in Adult Head CT Examinations

Purpose: The aim of this study was to collect CT dose index data from adult head exams to establish benchmarks based on either: (a) values pooled from all head exams or (b) values for specific protocols. One part of this was to investigate differences in scan frequency and CT dose index data for inpatients versus outpatients. Methods: We collected CT dose index data (CTDIvol) from adult head CT examinations performed at our medical facilities from Jan 1st to Dec 31th, 2014. Four of these scanners were used for inpatients, the other five were used for outpatients. All scanners used Tube Current Modulation. We used X-ray dose management software to mine dose index data and evaluate CTDIvol for 15807 inpatients and 4263 outpatients undergoing Routine Brain, Sinus, Facial/Mandible, Temporal Bone, CTA Brain and CTA Brain-Neck protocols, and combined across all protocols. Results: For inpatients, Routine Brain series represented 84% of total scans performed. For outpatients, Sinus scans represented the largest fraction (36%). The CTDIvol (mean ± SD) across all head protocols was 39 ± 30 mGy (min-max: 3.3–540 mGy). The CTDIvol for Routine Brain was 51 ± 6.2 mGy (min-max: 36–84 mGy). The values for Sinus were 24 ± 3.2 mGy (min-max: 13–44 mGy) and for Facial/Mandible were 22 ± 4.3 mGy (min-max: 14–46 mGy). The mean CTDIvol for inpatients and outpatients was similar across protocols with one exception (CTA Brain-Neck). Conclusion: There is substantial dose variation when results from all protocols are pooled together; this is primarily a function of the differences in technical factors of the protocols themselves. When protocols are analyzed separately, there is much less variability. While analyzing pooled data affords some utility, reviewing protocols segregated by clinical indication provides greater opportunity for optimization and establishing useful benchmarks.

60 APPLIED LIFE SCIENCES↗

MO-F-CAMPUS-I-02: Accuracy in Converting the Average Breast Dose Into the Mean Glandular Dose (MGD) Using the F-Factor in Cone Beam Breast CT- a Monte Carlo Study Using Homogeneous and Quasi-Homogeneous Phantoms

Purpose: To investigate the accuracy in estimating the mean glandular dose (MGD) for homogeneous breast phantoms by converting from the average breast dose using the F-factor in cone beam breast CT. Methods: EGSnrc-based Monte Carlo codes were used to estimate the MGDs. 13-cm in diameter, 10-cm high hemi-ellipsoids were used to simulate pendant-geometry breasts. Two different types of hemi-ellipsoidal models were employed: voxels in quasi-homogeneous phantoms were designed as either adipose or glandular tissue while voxels in homogeneous phantoms were designed as the mixture of adipose and glandular tissues. Breast compositions of 25% and 50% volume glandular fractions (VGFs), defined as the ratio of glandular tissue voxels to entire breast voxels in the quasi-homogeneous phantoms, were studied. These VGFs were converted into glandular fractions by weight and used to construct the corresponding homogeneous phantoms. 80 kVp x-rays with a mean energy of 47 keV was used in the simulation. A total of 109 photons were used to image the phantoms and the energies deposited in the phantom voxels were tallied. Breast doses in homogeneous phantoms were averaged over all voxels and then used to calculate the MGDs using the F-factors evaluated at the mean energy of the x-rays. The MGDs for quasi-homogeneous phantoms were computed directly by averaging the doses over all glandular tissue voxels. The MGDs estimated for the two types of phantoms were normalized to the free-in-air dose at the iso-center and compared. Results: The normalized MGDs were 0.756 and 0.732 mGy/mGy for the 25% and 50% VGF homogeneous breasts and 0.761 and 0.733 mGy/mGy for the corresponding quasi-homogeneous breasts, respectively. The MGDs estimated for the two types of phantoms were similar within 1% in this study. Conclusion: MGDs for homogeneous breast models may be adequately estimated by converting from the average breast dose using the F-factor.

60 APPLIED LIFE SCIENCES↗

Impact to Groundwater All-Pathways Dose Estimates for the Remote-Handled Low-Level Waste Disposal Facility Performance Assessment Using Updated Dose Coefficients from DOE-STD-1196-2022

The Performance Assessment (PA) for the Remote-Handled Low-Level Waste (RHLLW) Disposal Facility at Idaho National Laboratory (INL) was completed in 2018 (DOE-ID 2018) using dose coefficients from U.S. Department of Energy (DOE) Standard DOE-STD-1196-2011 (DOE 2011). Internal and external dosimetry was updated in 2021 and a new technical standard was published in 2022 (DOE-STD-1196-2022) (DOE 2022). This technical memorandum provides a comparison of the ingestion dose coefficients between those published in DOE (2011) and those published in DOE (2022). The dose coefficients in DOE (2022) were then used to calculate the all-pathways dose for the groundwater pathway and the results between the doses published in the 2018 PA and those calculated using the updated dose coefficients in DOE (2022) were compared. Several other issues in the 2018 RHLLW Disposal Facility PA were also addressed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of a real-time BeO ceramic fiber-coupled luminescence dosimetry system for dose verification of high dose rate brachytherapy

Purpose: The authors evaluate the capability of a beryllium oxide (BeO) ceramic fiber-coupled luminescence dosimeter, named radioluminescence/optically stimulated luminescence (RL/OSL) BeO FOD, for dosimetric verification of high dose rate (HDR) treatments. The RL/OSL BeO FOD is capable of RL and OSL measurements. Methods: The RL/OSL BeO FOD is able to be inserted in 6F proguide needles, used in interstitial HDR treatments. Using a custom built Perspex phantom, 6F proguide needles could be submerged in a water tank at 1 cm separations from each other. A second background fiber was required to correct for the stem effect. The stem effect, dose linearity, reproducibility, depth-dose curves, and angular and temperature dependency of the RL/OSL BeO FOD were characterised using an Ir-192 source. The RL/OSL BeO FOD was also applied to the commissioning of a 10 mm horizontal Leipzig applicator. Results: Both the RL and OSL were found to be reproducible and their percentage depth-dose curves to be in good agreement with those predicted via TG-43. A combined uncertainty of 7.9% and 10.1% (k = 1) was estimated for the RL and OSL, respectively. For the 10 mm horizontal Leipzig applicator, measured percentage depth doses were within 5% agreement of the published reference calculations. The output at the 3 mm prescription depth for a 1 Gy delivery was verified to be 0.99 ± 0.08 Gy and 1.01 ± 0.10 Gy by the RL and OSL, respectively. Conclusions: The use of the second background fiber under the current setup means that the two fibers cannot fit into a single 6F needle. Hence, use of the RL is currently not adequate for the purpose of in vivo brachytherapy dosimetry. While not real-time, the OSL is shown to be adequate for in vivo brachytherapy dosimetry.

60 APPLIED LIFE SCIENCES↗

Radiation Dose Prescription for Non-Small-Cell Lung Cancer According to Normal Tissue Dose Constraints: An In Silico Clinical Trial

Purpose: Local tumor recurrence remains a major problem in patients with inoperable non-small-cell lung cancer undergoing radiotherapy. We investigated the theoretical gain in the estimated tumor control probability (TCP) using an individualized maximal tolerable dose (MTD) prescription, for both conventional and accelerated fractionation schemes. Methods and Materials: For 64 non-small-cell lung cancer patients, five treatment plans were compared, dependent on the normal tissue dose constraints for the lung and spinal cord. The first two used a classic fractionation (2 Gy/d, 5 d/wk) to a total dose of 60 Gy (QD{sub classic}) or determined by the individualized MTD (QD{sub MTD}). The third scheme assumed a hypofractionated schedule of 2.75-Gy fractions (QD{sub hypofr}). The fourth and fifth assumed hyperfractionation and acceleration (1.8 Gy twice daily, either BID{sub classic} or BID{sub MTD}). The TCPs for the groups of patients were estimated. Results: The mean biologic equivalent dose in 2-Gy fractions for tumor, corrected for accelerated repopulation was significantly greater for the BID{sub MTD} scheme (62.1 Gy) than for any other scheme (QD{sub classic}, 47.5 Gy; QD{sub MTD}, 52.0 Gy; QD{sub hypofr}, 56.9 Gy; and BID{sub classic}, 56.9 Gy; p < 0.001). Although both dose-escalation (QD{sub MTD}) and hypofractionation (QD{sub hypofr}) resulted in an increase in the mean estimated TCP of 5.6% (p < 0.001) and 14.6% (p < 0.001), respectively, compared with QD{sub classic}, the combination of escalation and acceleration (BID{sub MTD}) improved the mean estimated TCP by 26.4% (p < 0.001). Conclusion: The results of this planning study showed a large gain in the estimated TCP using an MTD scheme with 1.8-Gy fractions BID compared with other fractionation schedules. Clinical studies implementing this concept are ongoing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗